Using Server Update Utility

Dell™ OpenManage™ Server Update Utility User's Guide

  What's New in This Release?

  Terms and Definitions

  Icon Glossary

  Supported Operating Systems

  GUI and CLI

  Using the GUI

  Using the CLI

  Other Documents You Might Need


Dell™ OpenManage™ Server Update Utility (SUU) is an application that identifies and applies updates to your system. You can use SUU to update your Dell system or to view the updates available for any system supported by SUU.

SUU compares the versions of components currently installed on your system with the update components packaged on the Dell Server Updates DVD. SUU then displays a comparison report of the versions and provides the option of updating the components.

NOTE: Only users with administrator (Microsoft® Windows®) or root (Linux) privileges can perform updates with SUU.

What's New in This Release?

The following features are introduced in SUU 1.8:

SUU 1.8 allows you to upgrade components using the -e or -upgradeonly command in the CLI. Earlier releases of SUU allowed you to update components (upgrade and downgrade in the same session) through the CLI. You could not perform only an upgrade. For a list of all the CLI commands, see Using the CLI.

SUU 1.8 allows you to downgrade components using the -n or -downgradeonly command in the CLI. Earlier releases of SUU allowed you to update components (upgrade and downgrade in the same session) through the CLI. You could not perform only a downgrade. For a list of all the CLI commands, see Using the CLI.

For detailed information about the supported Dell systems see the SUU Readme file located at the <%systemdrive%>\suu directory.


Terms and Definitions


Icon Glossary

Table 1-1 lists the icons that indicate the update status for a component in the Comparison Report.

Table 1-1. Icons and Update Status 

Icon

Status

The currently installed hardware component version or the Dell OpenManage component version is identical to the component version in the repository. No upgrade is needed.

The currently installed component version is newer than the component version in the repository. Click the Downgrade button to update the currently installed component version to the version in the repository.

The version of the currently installed component is older than the component version in the repository and it will be upgraded.

The update has been successful. A restart of the system is required for the changes to be effective.

This icon denotes any or all of the following scenarios:

  • The update is not supported on this system. SUU will end the current session and you may need to restart SUU to continue.
  • There is a hardware dependency error.

A package has failed after an update operation.

A hardware or software prerequisite failure.


Supported Operating Systems

SUU is supported on Dell PowerEdge systems running versions of Windows or Linux operating systems listed below.

For detailed information about the various Dell systems and operating systems that SUU is supported on, see the Dell Systems Software Support Matrix. This guide is available on the Dell Support website at support.dell.com or on the Dell Systems Management Tools and Documentation DVD.


GUI and CLI

SUU is both a Graphical User Interface (GUI) and a Command Line Interface (CLI) based application.

You can use the GUI to:

You can use the CLI to:


Using the GUI

To launch the SUU GUI, insert the Dell Server Updates DVD into the DVD drive.

If SUU does not launch automatically, navigate to the Dell Server Updates DVD root directory and launch suulauncher.exe (for Windows systems) or type suu -g (for both Windows and Linux systems) in a command window.

In the GUI, you can start with a comparison of the components in your Dell system and the components in the repository. You can then proceed to upgrade, downgrade, update components, or you can browse the repository for components.

Whenever SUU inventories your system for the list components installed, a progress bar that shows the progress of the inventory collection is displayed. After the progress bar completes 100%, SUU displays the Comparison Report.

NOTE: On the Red Hat Enterprise Linux Server version 5 operating system, DVDs are auto-mounted with the -noexec mount option. This option does not allow you to use the autorun feature or run any executable from the DVD. You need to manually mount the DVD and then run the executables.
NOTE: Ensure that the path from which you run SUU does not exceed 260 characters on the Windows operating system. On Linux systems, ensure that the path from which you run SUU does not exceed 4096 characters.

Prerequisites

When you start SUU, SUU performs a prerequisites check. In the prerequisites check, SUU performs an update and scans your system to determine if a hardware or software update is required. When the scan is complete, SUU displays the list of components whose prerequisite conditions are not met. The list of components may comprise hardware components, the Dell OpenManage component (software component), or hardware and software components.

If the components in your system meet the prerequisite conditions, SUU does not display the prerequisite failure messages. SUU displays the Comparison Report instead.

Software Prerequisite Failure

If the list of components that failed the prerequisite check comprises the Dell OpenManage component (software component), SUU displays a software prerequisite failure message as shown in Figure 1-1.

Figure 1-1. Software Prerequisite Failure Message

If the Dell OpenManage component is of a version earlier than 4.3, the prerequisites check fails. Install the Dell OpenManage component version 4.3 or later before proceeding with the software upgrade.

To install the Dell OpenManage component, see the Dell OpenManage Server Administrator User's Guide on the Dell Support website at support.dell.com or on the Dell Systems Management Tools and Documentation DVD.

You can also click Continue to proceed with the update of hardware components, if applicable. If you click Continue, the row for the Dell OpenManage component is disabled in the Comparison Report as shown in Figure 1-2.

Figure 1-2. Dell OpenManage Component Disabled

Hardware Prerequisites Failure

If the list of components that failed the prerequisite check comprises hardware components, SUU displays a message as shown in Figure 1-3.

Figure 1-3. Hardware Prerequisite Failure Message

Install these prerequisites before proceeding with the upgrade, downgrade, or update. You can also click Continue to proceed with the upgrade of the Dell OpenManage component, if applicable. To install the hardware prerequisites:

  1. Go to the Dell Support website at support.dell.com.

  2. In the Drivers and Downloads section, click Search for Drivers.

  3. In the Drivers and Downloads page, perform either of the following steps:

  4. Enter the service tag of your Dell system in the Enter a service tag field and click Go. Proceed to step 9.

  5. From the Select Your Product Model menu, select Servers, Storage, Networking.

  6. From the Select Your Product Line menu, select PowerEdge Server.

  7. From the Select Your Product Model list, select your PowerEdge system, and click Confirm.

  8. From the Operating System and Driver Language drop-down menus, select the appropriate operating system and language for your system.

  9. From the Category drop-down menu, select Systems Management.

  10. From the table of results displayed, click CD ISO - PowerEdge Updates Prerequisites v1.0 in the File Title(s) column.

  11. Click Download Now to save the PE Updates prereq cd.iso file on your system. Copy this file to a system that has a CD-burning program and create a bootable CD from the provided .iso file.

This creates the Prerequisites CD.

  1. Use the Prerequisites CD to bring your system up to meet prerequisite levels.

NOTE: Set the boot order in your system BIOS such that the CD drive is placed ahead of the system hard drive.
  1. Boot the system that fails to meet the prerequisites with the Prerequisites CD.

NOTE: An additional reboot may be required to complete the prerequisite update. Do not remove the CD until the information on the screen prompts you to do so.
  1. When prompted, replace the Prerequisites CD with the Dell Server Updates DVD and reboot the system.

If you click Continue, all the rows for the hardware components are disabled in the Comparison Report. If the Dell OpenManage component requires an upgrade, the corresponding row is enabled in the Comparison Report as shown in Figure 1-4. You can proceed to upgrade the Dell OpenManage component.

Figure 1-4. Hardware Components Disabled

Software and Hardware Prerequisites Failure

If the list of components for which the prerequisites failed, comprises the Dell OpenManage component (software component) and the hardware components, SUU displays a prerequisite failure message as shown in Figure 1-5.

Figure 1-5. Software and Hardware Prerequisite Failure Message

You cannot proceed with any hardware or software upgrades without installing the Dell OpenManage component or the hardware prerequisites. To install the Dell OpenManage component, see the Dell OpenManage Server Administrator User's Guide on the Dell Support website at support.dell.com or on the Dell Systems Management Tools and Documentation DVD. To install the hardware prerequisites, perform the steps in Hardware Prerequisites Failure.

You can click Continue to view the Comparison Report as shown in Figure 1-6. All the rows in the Comparison Report are disabled as both, the hardware and software components, failed to meet the prerequisite conditions.

Figure 1-6. Hardware and Software Components Disabled

Continuing With the Upgrade, Downgrade, or Update

When you perform an upgrade, downgrade, or update, SUU copies all the update packages into a local directory on the system. The directory is <%systemdrive%>:\dell\suu in Microsoft Windows and /var/log/dell/suu in Linux. You can select the packages you want to upgrade. You can also downgrade newer versions of components on your system to the corresponding component version contained in the Dell Server Updates DVD. For more information about downgrading components, see Downgrading Components.

NOTICE: Do not remove the Dell Server Updates DVD from the DVD drive when you are running SUU.

Comparing System Components With the SUU Repository Components

SUU compares the components installed on your system with the component versions available in the repository and displays the results in a Comparison Report. To view the Comparison Report, click your system's host name displayed in the left window directory tree.

NOTE: If your system's host name does not appear in the tree, either you do not have the correct user privileges, or your system does not support SUU. However, you can still browse the repository.

The Criticality column in the Comparison Report denotes the importance of applying the update. There are four levels of criticality: Urgent, Recommended, Optional, and Inapplicable. These levels are described in Table 1-2.

Table 1-2. Criticality Levels

Criticality Level

Status

Urgent

It is highly recommended to apply this update as soon as possible. The update contains changes to improve the reliability and availability of your Dell system.

Recommended

It is recommended to apply this update during your next scheduled update cycle. The update contains feature enhancements or changes that help keep your system software current and compatible with other system modules (firmware, BIOS, drivers, and software).

Optional

It is recommended that you review the specifics about the update to determine if it applies to your system. The update contains changes that impact only certain configurations, or provides new features that may/may not apply to your environment.

Inapplicable

This update is not applicable on your system. The component version on your system equals the repository version and hence, no update is required.

For every component on your system that is current with the version in the SUU repository, SUU displays a green checkmark icon .

For system components that are newer than the repository version components, SUU enables the Enable Downgrade check box. Select the Enable Downgrade check box and click the Downgrade button to downgrade these system components to the repository versions. For information on downgrading components, see Downgrading Components.

NOTE: The Enable Downgrade check box is enabled only if there is a component on the system that is newer than the repository version component.

SUU displays the Inapplicable icon if the component version on your system equals the repository version. In that case, the update is not applicable on your system.

If the upgrade components are available, SUU enables the Upgrade button on the upper right corner of the Comparison Report (see Figure 1-7). For information on upgrading components, see Upgrading Components.

NOTE: You cannot use SUU to update any firmware or device driver installed on your system that does not match a comparable repository component. You must manually update components installed on your system that do not compare with the repository.

If the Upgrade, Downgrade, or Update button is disabled, one of the following may apply:

NOTE: If the Comparison Report displays the same package name for more than one component in your system, and these components require an Upgrade, it means that a single execution of the package is sufficient to update all the components. Therefore, in the GUI, when you select/deselect one component, all other components that have the same package name are selected/deselected by default.

Figure 1-7. SUU Comparison Report

In this figure, the firmware, driver, and the Dell OpenManage components have been selected for an upgrade as the repository versions are newer than the current versions installed on the system.

One of the firmware components (Dell Remote Access Controller 5 Firmware) is recommended for a downgrade as the currently installed version is newer than the version in the repository.

Upgrading Components

To upgrade components from the repository:

  1. Select the components that you want to upgrade.

  2. Click the Upgrade button to apply the components that you have selected for your system. A Confirm Update dialog box prompts for confirmation to upgrade the listed components as shown in Figure 1-8.

Figure 1-8. Upgrade Confirmation

  1. Click Yes to continue or No to cancel.

While upgrading the components, SUU displays an update report as shown in Figure 1-9.

Figure 1-9. Upgrade Progress

  1. After the upgrade is completed, SUU displays an Update Complete dialog box. Click OK to complete the upgrade.

The status of the upgrade is reflected in the Comparison Report.

Downgrading Components

To downgrade components from the repository:

  1. Select the Enable Downgrade check box.

SUU disables the Enable System Set Update check box and selects only those components that are newer than the repository version components and can be downgraded as shown in Figure 1-10. This is an automatic process and you cannot select/deselect individual packages.

Figure 1-10. Downgrade

  1. Click the Downgrade button to start the downgrade. A Confirm Update dialog box prompts for confirmation to downgrade the listed components.

  2. Click Yes to continue or No to cancel.

While downgrading the components, SUU displays a progress report.

  1. After the downgrade is completed, SUU displays an Update Complete dialog box. Click OK to complete the downgrade.

The status of the downgrade is reflected in the Comparison Report.

Upgrade/Downgrade/Update Messages

When the upgrade/downgrade/update operation completes, you may get a message prompting you to restart the system to complete the upgrade/downgrade/update process. If so, leave the Dell Server Updates DVD in the DVD drive during the restart.

NOTE: When you upgrade/downgrade/update the BIOS, you must restart immediately. SUU does not allow you to continue until you restart the system.
NOTE: When you restart the system, log in using the same user account or user privileges that you used during the previous boot.

After you log into the operating system, open a command window and type suu -g (for both Windows and Linux systems), or suulauncher.exe (for Windows systems) to restart the SUU GUI.

Updating Multiple Systems on the Network

You can run SUU from a network location and update components on multiple systems. This feature is called the network share support feature.

NOTE: You must be connected to the network to use the network share support feature.

To run SUU from a network location:

  1. Access the system on the network on which SUU resides.

  2. Launch the SUU GUI to display the components to be updated in the Comparison Report.

  3. You can choose to update all the components in a single session by selecting the Enable System Set Update check box or you can choose to perform only an upgrade or a downgrade. For more information on the System Set Update feature, see Upgrading and Downgrading Components in a Single Session.

  4. Click the Update, Upgrade, or Downgrade button. A dialog box prompts for confirmation to update, upgrade, or downgrade the listed components.

  5. Click Yes to continue or No to cancel.

If you click Yes, SUU displays the Update dialog box that shows the progress of the update/upgrade/downgrade.

  1. Click OK when the update/upgrade/downgrade is completed.

The updates are reflected in the Comparison Report.

Ensure that the name of your report or the path in which you save the report does not exceed 260 characters if you are running SUU on Windows. On Linux systems, ensure that the name of your report does not exceed 255 characters or the path in which you save the report does not exceed 4096 characters.

Recommended Practices When Running SUU From a Network Location

Upgrading and Downgrading Components in a Single Session

You can upgrade and downgrade components at the same time using the System Set Update feature. This saves you the time and effort of upgrading or downgrading components one at a time.

To upgrade and downgrade components at the same time:

  1. Select the Enable System Set Update check box. When you select this check box, SUU disables the Enable Downgrade check box and the Upgrade button changes to the Update button as shown in Figure 1-11.

Figure 1-11. Enable Downgrade Check Box Disabled

All the components that can be updated are selected in the Comparison Report.

NOTE: You cannot deselect individual components when you select the Enable System Set Update check box.
  1. Click the Update button. SUU displays a Confirm Update dialog box that displays a list of components to be updated.

  2. Click Yes to proceed with the update or No to cancel the update.

If you click Yes, SUU displays the Update dialog box that shows the progress of the update.

  1. Click OK when the update is completed.

The updates are reflected in the Comparison Report.

NOTE: Do not click Update in SUU when the Comparison Report is displayed and an application other than the SUU is updating your system components. In such a scenario, restart SUU and then perform an update through SUU.
NOTE: The update status of some components will be effective only after you restart your system.

Upgrading Dell OpenManage Service Packs

From SUU version 1.5 onwards, you can upgrade Dell OpenManage service packs. The procedure to upgrade Dell OpenManage service packs is the same as that to upgrade the hardware components.

To upgrade Dell OpenManage service packs:

  1. Select the Dell OpenManage component.

  2. Click the Upgrade button. SUU displays a Confirm Update dialog box.

  3. Click Yes to proceed with the upgrade or No to cancel the upgrade.

If you click Yes, SUU displays the Update dialog box that shows the progress of the upgrade as shown in Figure 1-12.

Figure 1-12. Dell OpenManage Upgrade Progress

  1. Click OK in the Update Complete dialog box to complete the upgrade.

  2. Click OK in the Update dialog box.

Dell OpenManage service packs have been upgraded.

Continuing on Update Failures

You can choose whether to continue or stop the update if the package that you have selected for an update encounters an update failure.

To continue or stop updates:

  1. Select the components you want to update.

  2. Select the Stop on Update Failures check box as shown in Figure 1-13.

Figure 1-13. Stop on Update Failures Option Selected

NOTE: The Stop on Update Failures check box is enabled only if you have selected more than one component for an update.
  1. Click Upgrade.

SUU starts the upgrade of the components selected for upgrade. If SUU encounters a failure while updating the first component, SUU does not continue updating the other components. It displays the failure icon ( ) in the Update dialog box indicating that the update has failed. SUU also displays the icon in the Update dialog box denoting that the other components selected for update have not been updated.

After the update process, SUU displays an Update Error dialog box stating an update error as shown in Figure 1-14.

Figure 1-14. Failure of Update

If you do not select the Stop on Update Failures check box, and SUU encounters an update failure, then SUU continues updating the other components as shown in Figure 1-15.

Figure 1-15. Continue on Update Progress

In Figure 1-15, the first component was not updated because of an update failure. However, SUU has updated the second component because the Stop on Update Failures check box was not selected.

SUU then displays an Update dialog box that shows that the first component has not been updated but the second component has been updated. SUU also displays an Update Error dialog box that states an update failure as shown in Figure 1-16.

Figure 1-16. Continue on Update Error

  1. Click OK in the Update Error dialog box.

SUU has updated/stopped the updates of components depending on whether or not you selected the Stop on Update Failures check box.

Exporting the Comparison Report

You can export the Comparison Report and save it on your system as a CSV, HTML, or XML file.

To export the Comparison Report, click Export Report.

Figure 1-17. Export Report

You can save the report in a .csv, .html, or .xml format on your system.

NOTE: Ensure that the name of your report or the path in which you save the report does not exceed 260 characters if you are running SUU on Windows. On Linux systems, ensure that the name of your report does not exceed 255 characters or the path in which you save the report does not exceed 4096 characters.

Viewing Package and Bundle Details

In SUU, you can view the details of the packages or bundles displayed in the repository.

To view the details of a package, select a package in the repository table. The details are displayed in the Package Summary section as shown in Figure 1-18. You can also use the up-arrow and down-arrow keys to view the details of a package.

Figure 1-18. Package Details of a Selected Package

You can also view the details of a bundle.

To view the bundle-level details, select any bundle under the repository tree on the left-hand side pane of the SUU GUI. SUU displays the information for the selected bundle in the System Summary section and the packages specific to this bundle in the repository table as shown in Figure 1-19.

Hardware packages are denoted by the icon and software packages are denoted by the icon.

NOTE: You can use the <Tab> key to navigate through the Comparison Report table or the package/bundle-level details table and the <Ctrl><Tab> keys to navigate from the Comparison Report table or the package/bundle-level details table to the tree on the left-hand side of the SUU GUI.

Figure 1-19. Bundle-Level Details

Sorting Columns

You can sort the columns in the Comparison Report and the repository table by clicking the column names. SUU sorts the columns in the ascending or descending order. The icon indicates that the column has been sorted in the ascending order and the icon indicates that the column has been sorted in the descending order.

Figure 1-20 shows the Package Name column sorted in the ascending order.

Figure 1-20. Package Names Sorted

Browsing the Repository

To browse through the repository:

  1. Double-click the Repository icon on the left side of the application interface.

  2. Select your operating system. The Windows or Linux icon displays depending on your operating system. A list of supported systems is displayed.

  3. Click a system name to view the list of all available updates for that system.

Figure 1-21 shows all available components in the repository.

Figure 1-21. Repository

You can view the repository for all the systems that support Windows and Linux. See the DellSoftwareBundleReport.html in the repository directory for details on the contents of the repository.

Logging Events

SUU creates two event logs: update.log and support.log. The update log shows the status of each component updated. The support log contains trace and debug data and is only used by Dell Support.

The default location for the SUU logs in Microsoft Windows is <%systemdrive%>:\dell\suu. The default location for the Linux logs is /var/log/dell/suu.

NOTE: You can use the suu -d command in the CLI to change the default location of the SUU logs.
NOTE: The directory that you specify for the event logs must exist. SUU does not create the directory.

Using the CLI

To run SUU from the CLI, you must be in the Dell Server Updates DVD root directory. If you are running SUU on a network share, copy the Dell Server Updates DVD contents to a shared directory and run the CLI from the shared directory.

All CLI commands begin with the suu string followed by a space and then the short or long form of the command. If you type suu -? or suu -help or suu -h, the command line interface displays the syntax for SUU CLI commands:

Usage: suu [<command>] [-d | -directory <directory_name>]

Table 1-3 lists the SUU commands. To run a CLI command, open a command window and type the appropriate CLI command syntax at the command prompt.

Table 1-3. Server Update Utility CLI Commands 

CLI Command Syntax

Command Description

-? | -h | -help

Shows this help message.

-g | -gui

Launches the SUU graphical user interface.

NOTE: On Linux, this option can only be used from the X Window system.

-u | -update

Upgrades/downgrades the system component.

NOTE: The –u command performs an upgrade and downgrade of the components in your system. Components in your system that are of a higher version than the components in the repository will be downgraded without prompting you for confirmation. This is not always recommended. To perform explicit upgrades or downgrades, use the -upgradeonly or -downgradeonly commands.

-e | -upgradeonly

Upgrades all components whose repository versions are newer than the current versions installed on the system. You cannot upgrade individual components through the CLI. To do this, use the GUI.

-n | -downgradeonly

Downgrades all the system components newer than repository components to the repository versions. SUU does not allow you to downgrade individual components.

-p | -progress

Shows the progress of the upgrade/downgrade.

-c | -comparison

Compares the current component.

-d | -directory

Directs the event logs to a different directory than the default location.

-installIPMI

Installs/updates the OpenIPMI driver.

NOTE: This syntax is available on Linux systems only.

-s | -stoponfail

Stops the update if a failure during the update of the first component is encountered.

-iprog|-inventoryprogress

Shows the progress (in percentage) of the comparison between the components in your system and the components in the repository.

Changing the Default Location of Logs

The default location for SUU event logs in Windows is <%systemdrive%>:\dell\suu. The default location for the logs in Linux is /var/log/dell/suu.

When you type suu with a command and a directory path, you can change the default location for logs for that session of SUU. To change the directory location for logs for a session of SUU, type:

suu <command> -directory <path>

For example, if you type suu -u -directory c:\tmp, SUU runs an update on the system and redirects logs to c:\tmp instead of c:\dell\suu.

Viewing the Comparison Report

To run the SUU comparison application, type suu -c. A welcome screen is displayed. While the comparison is in progress, the following message accompanied by a spinning bar is displayed:

| finding applicable system update set

When complete, the Comparison Report displays as in the following example:

========Comparison Results========

Component: BIOS

Component type: BIOS

current version: A11 < repository version A12

package name: PE1600SC-BIOS-WIN-Al2.exe

The Comparison Report provides a listing of the installed system components and the comparable SUU repository components. The comparison of the version levels is indicated with the arithmetic symbols > (greater than), < (less than), and = (equal to). The report also lists the available Dell Update Package to update the component.

Updating Components

NOTE: The update command from the CLI can be used for both an upgrade and a downgrade.

To update your system with the selected components, type suu -u. All components that are not up-to-date with the components in the repository are upgraded. System components with versions newer than the repository version are downgraded to the repository level versions.

Installing IPMI

The -installIPMI command installs/updates the OpenIPMI driver on your Linux system. If SUU detects that updates need the OpenIPMI driver to be installed and you run commands such as suu -g, suu -c, suu -u, or suu -p, an error message displays asking you to install the required OpenIPMI driver and SUU exits. Run the suu -g -installIPMI command to launch the GUI and install/upgrade the OpenIPMI driver automatically.

NOTE: The Dell Server Updates DVD contains the OpenIPMI driver for Linux.

If a lower version of the OpenIPMI driver is currently installed on your system, running the -installIPMI command updates the lower version to that of the OpenIPMI driver contained on the Dell Server Updates DVD.

If there is the same or higher version of OpenIPMI driver currently installed on your system, running the -installIPMI command does not affect the currently installed driver.

Viewing the Update Progress

To view the progress for your update, open another command shell and type suu -p.

A progress report similar to the following appears:

======update progress======

Package name : RAC_FRMW_WIN_R104824.EXE

Status : Update Successful

---------------------------------------

Package name: PE1750-BIOS-WIN-A11.exe

Status : Update is in progress

Viewing the Inventory Progress

To view the inventory progress when SUU is collecting information about the components on your system, open another command shell and type suu -iprog.

A progress report similar to the following appears:

====== system inventory progress ======

no progress available

====== system inventory progress ======

54% Complete

Stopping on Update Failure

You can choose to continue or stop further updates if the selected update packages encounter an update failure. To stop updates, type suu -u -s. If an update failure is encountered, SUU stops further package updates.

If you do not specify any parameter during the update, that is, if you type suu -u, SUU continues to update other packages even if it encounters an update failure.


Other Documents You Might Need

Besides this guide, you can find the following guides either on the Dell Support website at support.dell.com or on the Dell Systems Management Tools and Documentation DVD:

Dell OpenManage Server Administrator is a comprehensive, one-to-one systems management solution, designed for system administrators, to manage systems locally and remotely on a network.

The readme files for SUU and Dell Update Packages ship on the Dell Server Updates DVD. These readme files contain the latest information about SUU and Dell Update Packages in addition to information about known issues.

The DellSoftwareBundleReport.html file in the repository directory (<%systemdrive%>:\suu\repository) contains details about the contents of the repository in a readable format. This is an HTML file that you can use as a quick reference for information about supported systems, packages, bundles, and other details.


Back to Contents Page