﻿Emulex® Drivers for VMware ESXi Release Notes

Release
	ESXi 6.5 	12.2.212.10

Purpose and Contact Information

These release notes describe the new features, resolved issues, known issues, and technical tips associated with these Emulex® drivers for VMware releases. 

For the latest product documentation, go to www.broadcom.com. If you have questions or require additional information, contact an authorized Broadcom® Technical Support representative at ecd-tech.support@broadcom.com.

New Features

1. Discontinues support for the VMware ESXi 6.0 operating system. 

2. Adds support for LPe35000 and LPe35002 adapters. 

3. Adds duration support for the Link Cable Beacon command. 

This avoids situations in which the blinking of an HBA LED might be initiated, but no command is sent to stop the blinking. 

4. Adds support for multiple dumps in the flash memory of an adapter. 

If there are multiple dumps in the flash memory of an adapter, the dump command will generate multiple .txt and .bin files. 

5. Adds driver and management applications support for Reliability – Availability – Serviceability (RAS) (also called firmware log collection) for LPe31000-series, LPe32000-series, and LPe35000-series adapters. 

6. Adds support for remote-switched HBA link diagnostics tests on Cisco switches. 

7. Adds support for Fibre Channel Security Protocol (FC-SP) DHCHAP authentication between an adapter and a switch. 

Resolved Issues

1. Revision B of the FOIT AFCT-57F3TMZ-ELX (16GFC longwave optic transceiver) supports D_Port (also called ClearLink®) for MDS Diagnostic for Cisco switches. 

2. Short FCP response for the targets sending 16 bytes of FCP_RSP is fixed. 

3. Node list memory double free no longer occurs during driver unload. 

Known Issues

All Versions, Known Issues

1. Known issues related to software migration.

Beginning with software release 11.2, FC HBAs and OneConnect® adapters have independent software kits. Before 
updating earlier drivers and applications to the software in release 12.2.1, refer to the Emulex Software Kit Migration User 
Guide for special instructions and considerations for using the 11.2 and later software kits for FC HBAs and OneConnect 
adapters.

2. The adapter model name and description do not match the vendor brand name field. 

The VMware vSphere client only shows adapter family model names with a single port. 

For example:

LPe32002 adapter is shown as the Emulex LightPulse LPe32000 PCIe Fibre Channel Adapter.

LPe35002 adapter is shown as the Emulex LightPulse LPe36000 Fibre Channel Adapter.

This issue occurs with the native tool lspci as well. The vSphere client gets the adapter model name and description from the XML package files installed with the operating system or with an out-of-box kit, rather than from the adapter vital product data (VPD). Other native tools work in a similar manner.

Workaround

To show all available Key Value (KV) instances, use the following command:

/usr/lib/vmware/vmkmgmt_keyval/vmkmgmt_keyval -d

For storage adapters, look for vmhbaX/Emulex.

3. Certain inbox drivers do not support LPe35000-series adapters, as described in the following table.

Table 1:  Operating System and Support for LPe35000-Series Adapters

Operating System	Support for LPe35000-Series Adapters

ESXi 6.5		No; use the latest I/O Vendor Partner (IOVP) certified driver.

Workaround

Follow the guidelines in Table 1.

4. When the Virtual Machine Identifier (VMID) feature is used in an ESXi environment with ESXi mobility (vMotion), the VMID strings might not be available from the operating system on the backup server (the server to which vMotion moved) for 10–20 minutes. During this time, the VMID strings are not available for registration on the fabric switch. 

Workaround

After the vMotion action, wait until the operating system settles and the VMID strings are available.

5. With VMID enabled, warning messages are generated even if no issue is present. 

Workaround

No workaround is available for the currently released ESXi versions. However, VMware is planning the following new operating system releases, which might address this issue. (Check with VMware to be sure this issue was addressed before upgrading the operating system.)

– ESXi 6.5 U1 (and Emulex RT 11.4 driver)

6. Revision A of the FOIT AFCT-57F3TMZ-ELX (16GFC longwave optic transceiver) does not support D_Port for MDS Diagnostic for Cisco switches. 

Workaround

None.

7. Neither Revision A nor Revision B of the FOIT AFCT-57F3TMZ-ELX (16GFC longwave optic transceiver) supports D_Port for Brocade® switches. 

Workaround

None.

8. Boot from SAN is not supported if FC-SP-2 authentication (DH-CHAP) is enabled. 

9. On LPe35002 adapters, an unrecoverable operating system fault might occur if either the driver is run in INTx mode or if the driver parameter lpfc_use_msi is set to 0. 

10. Brocade switches using Fabric Operating System (FOS) version 8.2.1B and earlier might encounter the following issues with DHCHAP authentication:

– You might not be able to configure the secret pair between the switch and the HBA. When authentication is enabled on the switch, and authentication is disabled on the HBA, the switch disables the port, but it does not issue the expected status messages. 

– The Brocade switch authenticates the HBA port when authentication is disabled on the switch, or when a frame is dropped. 

11. An unrecoverable operating system fault might occur if there are lots of RSCN/ELS commands processing and the driver unloads in parallel. 

Workaround

None.

ESXi 6.5 Known Issues

There are no known issues.


Technical Tips

1. ESXi servers can appear to have the same VMID Application ID. The VMID is the combination of the Application ID appended to the end of the N_Port ID, which provides uniqueness within the fabric.

2. To see VMID information on all VMs in a multipathing configuration, set the path policy to Round Robin.

3. The server must be in ESXi maintenance mode to safely change the firmware in flash memory.

For operations such as firmware download, bring the server into ESXi maintenance mode prior to flashing the firmware.

4. Install an offline bundle locally on an ESXi server using the esxcli command.

Install an offline bundle on a VMware ESXi server locally using the esxcli command. 

[root@testmachine ~]# esxcli software vib install --maintenance-mode -d <offline-bundle.zip>

Where <offline-bundle.zip> is the file name of the offline bundle to be installed.

In the esxcli elxmgmt management setdriverparam command, you can set the ras-fwlog-buffsize driver parameter for multiple ports of the adapter. The ras-fwlog-buffsize driver parameter when set to a nonzero value, allows enabling firmware logs on an adapter, on reboot. You must set only one port of the adapter to have a nonzero value. If you set multiple ports of the adapter to a nonzero value, on reboot, you can only capture the logs on the port which was last set.

5. If D_Port is enabled on an adapter, the target connection is not supported in a direct-connect point-to-point environment. 

Workaround

Disable dynamic D_Port on an adapter using the management application.

6. DH-CHAP and Dynamic D_Port are mutually exclusive. If both features are enabled simultaneously, warning messages will result. You must either disable DH-CHAP via the lpfc_enable_auth parameter, or disable Dynamic D_Port via the OneCommand® Manager application.

7. D_Port and FA-PWWN cannot be enabled simultaneously. 

Workaround

If D_Port is enabled and you want to enable FA-PWWN, you must first disable D_Port. If FA-PWWN is enabled and you want to enable D_Port, you must first disable FA-PWWN.