ISILON-TRAP-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, Counter64
        FROM SNMPv2-SMI
    NOTIFICATION-GROUP, OBJECT-GROUP, MODULE-COMPLIANCE
        FROM SNMPv2-CONF
    isilon, nodeName, nodeSerialNumber
        FROM ISILON-MIB
;

isilonTraps MODULE-IDENTITY
    LAST-UPDATED "201806120000Z"    --12 JUN 2018--
    ORGANIZATION "Isilon Systems LLC"
    CONTACT-INFO
        "Isilon Systems LLC
         Support phone: 1-800.782.4362
         Support website: http://support.emc.com
        "
    DESCRIPTION
        "Add new event that detects under-provisioned node pools."
    REVISION "201806120000Z"    --12 JUN 2018--
    DESCRIPTION
        " Added OIDs for Infinity hardware traps.
        "
    REVISION "201805300000Z"    --30 MAY 2018--
    DESCRIPTION
        "Add eventId and eventIdName to variables table"
    REVISION "201801030000Z"    --03 JAN 2018--
    DESCRIPTION
        "Fixed node/trap conformance groups.

        Removed unused trap types:
        nodeExpStatusCrit
        nodeRebootCoalescedInfo
        nodeStatusCoalescingCrit
        nodeStatusCoalescingWarn
        clusterStorageUsageCrit
        clusterStorageUsageWarn
        filesysCoalesceCrit
        filesysCoalesceWarn
        siqEventCrit
        siqEventWarn
        siqPolicyCoalescedCrit
        siqPolicyCoalescedWarn
        siqTargetCoalescedCrit
        siqTargetCoalescedWarn
        nodeCPUWarn
        nodeCPUInfo
        mixedSedNonSedClusterCrit
        suggestedProtectionCrit
        avscanCoalescedInfo
        avscanCoalescedWarn
        avscanCoalescedCrit
        sharePermsUpgradeFailCrit
        winNetworkCoalesceCrit
        winNetworkCoalesceWarn
        winIDmapCoalesceCrit
        winIDmapCoalesceWarn
        winAuthCoalesceCrit
        winAuthCoalesceWarn
        netStatusCoalescingCrit
        netStatusCoalescingWarn
        hardwareCoalescedEmerg
        hardwareCoalescedCrit
        hardwareCoalescedWarn
        diskErrorCoalescedCrit
        diskErrorCoalescedWarn
        hwFanOverInfo
        hwFanUnderInfo
        hwFanWarn
        hwPowerWarn
        sensorCoalescedEmerg
        sensorCoalescedCrit
        sensorCoalescedWarn
        fanCoalescedEmerg
        fanCoalescedCrit
        fanCoalescedWarn
        tempCoalescedEmerg
        tempCoalescedCrit
        tempCoalescedWarn
        voltsCoalescedEmerg
        voltsCoalescedCrit
        voltsCoalescedWarn
        hwCurrentOverEmerg
        hwCurrentOverCrit
        hwCurrentOverWarn
        hwCurrentOverInfo
        hwCurrentUnderEmerg
        hwCurrentUnderCrit
        hwCurrentUnderWarn
        hwCurrentUnderInfo
        storageTransportCoalescedEmerg
        storageCoalescedCrit
        storageCoalescedWarn

        Fixed trap OID numbering scheme where pattern violated:
        ssdUsageCrit, ssdUsageWarn, ssdUsageInfo
        nfsCookieTranslationFailedInfo
        winSmbUpgradeWarn
        sasPhyErrorControllerWarn (this was also moved to storageTransportTraps.2)
        driveStatusInfo
        diskErrorWarn
        sensorMonitorCrit
        sensorMonitorWarn

        Added/changed traps to fit severity mapping of events to traps:
        added: siqErrorCrit, siqErrorInfo
        mixedSedNonSedClusterCrit -> mixedSedNonSedClusterWarn
        suggestedProtectionCrit -> suggestedProtectionWarn
        sasPhyErrorExpanderCrit
        sasPhyErrorControllerCrit

        Removed unused trap varbinds args:
        stringarg on nfsCookieTranslationFailedInfo
        4x stringargs from celogHeartBeatEvent*

        Added default varbinds to trap definitions: eventId, eventIdName,
        nodeIdentifier for trap pertaining to a single node.
        Adding trap varbinds to trap definitions to match CELOG var binds.
        "
    REVISION "201712200000Z"    --20 DEC 2017--
    DESCRIPTION
        "MIB maintenance, move eventKbUrl, licenseActivationIncomplete,
        licenseEntitlementsExceed OIDs to resolve conflicts, remove duplicate
        cloudpoolObjectNotFoundError OID"
    REVISION "201705310000Z"    --31 MAY 2017--
    DESCRIPTION
        "Adding licenseActivationIncomplete and licenseEntitlementsExceeded
         traps"
    REVISION "201609070000Z"    --07 SEP 2016--
    DESCRIPTION
        "Adding event knowledge base URLs."
    REVISION "201603180000Z"    --18 MAR 2016--
    DESCRIPTION
        "Traps for Isilon Systems OneFS operating system."
    REVISION "201504080000Z"    --07 APR 2015--
    DESCRIPTION
        "MIB maintenance, added compliance groups and reorder positions,
        but not OIDs."
    REVISION "201306210000Z"    --21 JUN 2013--
    DESCRIPTION
        "Traps for Isilon Systems CloudPools."
    REVISION "201303210000Z"    --02 APR 2013--
    DESCRIPTION
        "Added trap for missing required bootdisk mirror failures.
         Added: bootdiskMirrorReqMissingCrit"
    REVISION "201209210000Z"    --21 SEP 2012--
    DESCRIPTION
        "Updated some traps that were wrong.
         Removed: sasPhyErrorWarn, sasPhyErrorCrit
         Added: sasPhyErrorExpanderWarn, sasPhyErrorControllerWarn"
    REVISION "201208010000Z"    --01 AUG 2012--
    DESCRIPTION
        "Add instanceIdentifier to object list for all traps."
    REVISION "201205230000Z"    --23 MAY 2012--
    DESCRIPTION
        "Renamed FlexProtectRunning* objects to be lower case
         per SMI/SNMP standards. Added OBJECTS list to traps.
         Minor cleanup and formatting."
    REVISION "201204300000Z"    --30 APRIL 2012--
    DESCRIPTION
        "Added traps for different priority job failures."
    REVISION "201109290000Z"    --29 SEPTEMBER 2011--
    DESCRIPTION
        "Added storage transport traps."
    REVISION "200911120000Z"    --12 NOVEMBER 2009
    DESCRIPTION
        "Reworked to align with the new event management and notification
         system"
    REVISION "200911100000Z"    --10 NOVEMBER 2009--
    DESCRIPTION
        "Initial revision."
    ::= { isilon 250 }

groupStateTraps OBJECT IDENTIFIER ::= { isilonTraps 10 }
filesystemTraps OBJECT IDENTIFIER ::= { isilonTraps 11 }
smartQuotaTraps OBJECT IDENTIFIER ::= { isilonTraps 12 }
snapshotTraps   OBJECT IDENTIFIER ::= { isilonTraps 13 }
syncIQTraps     OBJECT IDENTIFIER ::= { isilonTraps 14 }
softwareTraps   OBJECT IDENTIFIER ::= { isilonTraps 15 }
avscanTraps     OBJECT IDENTIFIER ::= { isilonTraps 16 }
netProtoTraps   OBJECT IDENTIFIER ::= { isilonTraps 17 }
networkingTraps OBJECT IDENTIFIER ::= { isilonTraps 18 }
hardwareTraps   OBJECT IDENTIFIER ::= { isilonTraps 19 }
systemDiskTraps OBJECT IDENTIFIER ::= { isilonTraps 20 }
sensorTraps     OBJECT IDENTIFIER ::= { isilonTraps 21 }
storageTransportTraps   OBJECT IDENTIFIER ::= { isilonTraps 22 }
cloudPoolsTraps OBJECT IDENTIFIER ::= { isilonTraps 23 }
upgradeTraps    OBJECT IDENTIFIER ::= { isilonTraps 24 }
celogTraps    OBJECT IDENTIFIER ::= { isilonTraps 25 }
variables       OBJECT IDENTIFIER ::= { isilonTraps 50 }
trapConformance OBJECT IDENTIFIER ::= { isilonTraps 51 }
trapCompliance  OBJECT IDENTIFIER ::= { isilonTraps 52 }

nodeIdentifier OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The Logical Node Number of the node referenced in the notification.
        "
    ::= { variables 1 }

measuredValue OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The measured value that triggered the event
        "
    ::= { variables 2 }

units OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The units of the measurement
        "
    ::= { variables 3 }

oid OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The OID of the sensor reporting a problem
        "
    ::= { variables 4 }

bay OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Drive bay number
        "
    ::= { variables 5 }

ifName OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Interface name
        "
    ::= { variables 6 }

phy OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "PHY connection
        "
    ::= { variables 7 }

errorMessage OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Error message
        "
    ::= { variables 8 }

errno OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Error number
        "
    ::= { variables 9 }

stringArg OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "A trap-related string argument.
        "
    ::= { variables 10 }

message OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "A trap-related message string.
        "
    ::= { variables 11 }

i64Arg OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Error number
        "
    ::= { variables 12 }

i32Arg OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Integer argument
        "
    ::= { variables 13 }

measuredValueStr OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The measured value that triggered the event represented as string
        "
    ::= { variables 14 }

instanceIdentifier OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Instance ID of event generating the trap
        "
    ::= { variables 15 }

deviceIdentifier OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "The Device Node Number of the node referenced in the notification.
        "
    ::= { variables 16 }

physIfaces OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Names of aggregated interfaces
        "
    ::= { variables 17 }

eventKbUrl OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Knowledge base URLs for events.
         The OID can take multiple values.
         The external and internal URLs for each event will be displayed separately in the trap.
        "
    ::= { variables 18 }

eventId OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Unique ID for this event or eventgroup
        "
    ::= { variables 19 }

eventIdName OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "Unique ID Name for this event or eventgroup
        "
    ::= { variables 20 }

nodeStatus  OBJECT IDENTIFIER ::= { groupStateTraps 1 }

nodeStatusCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A critical node status event has occurred.
        "
    ::= { nodeStatus 3 }

nodeStatusInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node status event has occurred.
        "
    ::= { nodeStatus 7 }

nodeShutdown OBJECT IDENTIFIER ::= { groupStateTraps 3 }

nodeShutdownInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node is being shut down or rebooted.
        "
    ::= { nodeShutdown 7 }

nodeShutdownFail OBJECT IDENTIFIER ::= { groupStateTraps 4 }

nodeShutdownFailCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Shut down or reboot failed for a node.
        "
    ::= { nodeShutdownFail 3 }

partitionUsage OBJECT IDENTIFIER ::= { filesystemTraps 1 }

partitionUsageCrit NOTIFICATION-TYPE
    OBJECTS     { units, nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A partition is over the critical threshold percentage.
        "
    ::= { partitionUsage 3 }

partitionUsageWarn NOTIFICATION-TYPE
    OBJECTS     { units, nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A partition is over the warning threshold percentage.
        "
    ::= { partitionUsage 5 }

partitionUsageInfo NOTIFICATION-TYPE
    OBJECTS     { units, nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A partition is over the info threshold percentage.
        "
    ::= { partitionUsage 7 }

filesysError    OBJECT IDENTIFIER ::= { filesystemTraps 3 }

filesysErrorCrit    NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A critical /ifs filesystem error has occurred
        "
    ::= { filesysError 3 }

filesysErrorWarn    NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A warning-level /ifs filesystem error has occurred
        "
    ::= { filesysError 5 }

filesysErrorInfo    NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An /ifs filesystem error has occurred.
        "
    ::= { filesysError 7 }

diskPoolUsage OBJECT IDENTIFIER ::= { filesystemTraps 4 }

diskPoolUsageCrit NOTIFICATION-TYPE
    OBJECTS     { units, stringArg, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node pool is near capacity.
        "
    ::= { diskPoolUsage 3 }

diskPoolUsageWarn NOTIFICATION-TYPE
    OBJECTS     { units, stringArg, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node pool is near capacity.
        "
    ::= { diskPoolUsage 5 }

diskPoolOldDbVersion OBJECT IDENTIFIER ::= { filesystemTraps 5 }

diskPoolOldDbVersionWarn NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The SmartPools upgrade has not completed.
        "
    ::= { diskPoolOldDbVersion 5 }

ssdUsage OBJECT IDENTIFIER ::= { filesystemTraps 6 }

ssdUsageCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, units, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The SSD drives are at capacity.
        "
    ::= { ssdUsage 3 }

ssdUsageWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, units, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The SSD drives are near capacity.
        "
    ::= { ssdUsage 5 }

ssdUsageInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, units, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The SSD drives are near capacity.
        "
    ::= { ssdUsage 7 }

quotaThreshError OBJECT IDENTIFIER ::= { smartQuotaTraps    1 }

quotaThreshErrorInfo    NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SmartQuotas threshold violation
        "
    ::= { quotaThreshError 7 }

quotaNotifyError OBJECT IDENTIFIER ::= { smartQuotaTraps    2 }

quotaNotifyErrorWarn    NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SmartQuotas threshold notification failed
        "
    ::= { quotaNotifyError 5 }

quotaError OBJECT IDENTIFIER ::= { smartQuotaTraps  3 }

quotaErrorWarn  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SmartQuotas error
        "
    ::= { quotaError 5 }

snapshotError   OBJECT IDENTIFIER ::= { snapshotTraps 1 }

snapshotErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { errorMessage, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Snapshot error
        "
    ::= { snapshotError 5 }

snapshotReserve OBJECT IDENTIFIER ::= { snapshotTraps 2 }

snapshotReserveCrit NOTIFICATION-TYPE
    OBJECTS     { units, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Snapshot reserve space is over its critical limit
        "
    ::= { snapshotReserve 3 }

snapshotReserveWarn NOTIFICATION-TYPE
    OBJECTS     { units, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Snapshot reserve space is over its warning limit
        "
    ::= { snapshotReserve 5 }

siqError OBJECT IDENTIFIER ::= { syncIQTraps 2 }

siqErrorCrit    NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SyncIQ error
        "
    ::= { siqError 3 }

siqErrorWarn    NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SyncIQ error
        "
    ::= { siqError 5 }

siqErrorInfo    NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "SyncIQ error
        "
    ::= { siqError 7 }

jobEngineError  OBJECT IDENTIFIER ::= { softwareTraps 1 }

jobEngineErrorEmerg NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The cluster encountered one or more job failures.
        "
    ::= { jobEngineError 1 }

jobEngineErrorCrit NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The cluster encountered one or more job failures.
        "
    ::= { jobEngineError 3 }

jobEngineErrorWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The cluster encountered one or more job failures.
        "
    ::= { jobEngineError 5 }

jobEngineErrorInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The cluster encountered one or more job failures.
        "
    ::= { jobEngineError 7 }

flexProtectRunning OBJECT IDENTIFIER ::= { softwareTraps 2 }

flexProtectRunningCrit  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster is in need of restripe but FlexProtect is not running
        "
    ::= { flexProtectRunning 3 }

flexProtectRunningWarn  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster is in need of restripe but FlexProtect is not running
        "
    ::= { flexProtectRunning 5 }

flexProtectRunningInfo  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster is in need of restripe but FlexProtect is not running
        "
    ::= { flexProtectRunning 7 }

mcpProcFailed OBJECT IDENTIFIER ::= { softwareTraps 5 }

mcpProcFailedWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "MCP reports a process has failed on a node
        "
    ::= { mcpProcFailed 5 }

mcpProcKilled OBJECT IDENTIFIER ::= { softwareTraps 6 }

mcpProcKilledWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "MCP killed a process on a node
        "
    ::= { mcpProcKilled 5 }

licenseExpiration OBJECT IDENTIFIER ::= { softwareTraps 7 }

licenseExpirationWarn   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "One or more licenses has expired
        "
    ::= { licenseExpiration 5 }

licenseExpirationInfo   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "One or more licenses is about to expire
        "
    ::= { licenseExpiration 7 }

licenseActivationIncomplete OBJECT IDENTIFIER ::= { softwareTraps 28 }

licenseActivationIncompleteWarn   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Licensing activation incomplete
        "
    ::= { licenseActivationIncomplete 5 }

licenseEntitlementsExceeded OBJECT IDENTIFIER ::= { softwareTraps 29 }

licenseEntitlementsExceededWarn   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "License entitlements exceeded
        "
    ::= { licenseEntitlementsExceeded 5 }

firmwareUpdateIncomplete OBJECT IDENTIFIER ::= { softwareTraps 8 }

firmwareUpdateIncompleteWarn    NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A firmware update was not completely applied
        "
    ::= { firmwareUpdateIncomplete 5 }

testEvent OBJECT IDENTIFIER ::= { softwareTraps 9 }

testEventCrit   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Test event
        "
    ::= { testEvent 3 }

mountdClientMountFailed OBJECT IDENTIFIER ::= { softwareTraps 11 }

mountdClientMountFailedInfo NOTIFICATION-TYPE
    OBJECTS     { nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Mountd denied client mount request
        "
    ::= { mountdClientMountFailed 7 }

mountdHostLookupFailed OBJECT IDENTIFIER ::= { softwareTraps 12 }

mountdHostLookupFailedInfo  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Mountd host lookup failed
        "
    ::= { mountdHostLookupFailed 7 }

nfsCookieTranslationFailed OBJECT IDENTIFIER ::= { softwareTraps 15 }

nfsCookieTranslationFailedInfo NOTIFICATION-TYPE
    OBJECTS { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "64bit to 32bit cookie translation failed"
    ::= { nfsCookieTranslationFailed 7 }

mixedSedNonSedCluster OBJECT IDENTIFIER ::= { softwareTraps 13 }

mixedSedNonSedClusterWarn  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster contains a mix of encrypting nodes and non-encrypting nodes
        "
    ::= { mixedSedNonSedCluster 5 }

suggestedProtection OBJECT IDENTIFIER ::= { softwareTraps 14 }

suggestedProtectionWarn  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster is underprotected.
        "
    ::= { suggestedProtection 5 }

unprovisionedNode OBJECT IDENTIFIER ::= { softwareTraps 30 }

unprovisionedNodeWarn  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName,
    nodeIdentifier }
    STATUS      current
    DESCRIPTION
        "A node is unprovisioned.
        "
    ::= { unprovisionedNode 5 }

underprovisionedNodePool OBJECT IDENTIFIER ::= { softwareTraps 31 }

underprovisionedNodePoolWarn  NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Node pool is under-provisioned.
        "
    ::= { underprovisionedNodePool 5 }

testEvent2 OBJECT IDENTIFIER ::= { softwareTraps 26 }

testEvent2Crit   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Critical test event 2
        "
    ::= { testEvent2 3 }

testEvent2Warn   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Warning test event 2
        "
    ::= { testEvent2 5 }

testEvent2Info   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Info test event 2
        "
    ::= { testEvent2 7 }

checkCluster OBJECT IDENTIFIER ::= { softwareTraps 16 }

checkClusterCrit   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "isi_check_cluster
        "
    ::= { checkCluster 3 }

checkClusterWarn   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "isi_check_cluster
        "
    ::= { checkCluster 5 }

checkClusterInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "isi_check_cluster
        "
    ::= { checkCluster 7 }

clusterMonthlyStatus OBJECT IDENTIFIER ::= { softwareTraps 17 }

clusterMonthlyStatusInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster monthly status
        "
    ::= { clusterMonthlyStatus 7 }

clusterMonthlyStatusWarn   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster monthly status
        "
    ::= { clusterMonthlyStatus 5 }

clusterMonthlyStatusCrit   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Cluster monthly status
        "
    ::= { clusterMonthlyStatus 3 }

jobEngineJobState OBJECT IDENTIFIER ::= { softwareTraps 18 }

jobEngineJobStateInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Job engine job state
        "
    ::= { jobEngineJobState 7 }

jobEngineJobPhaseBegin OBJECT IDENTIFIER ::= { softwareTraps 19 }

jobEngineJobPhaseBeginInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Job engine job phase begin
        "
    ::= { jobEngineJobPhaseBegin 7 }

jobEngineJobPhaseEnd OBJECT IDENTIFIER ::= { softwareTraps 20 }

jobEngineJobPhaseEndInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Job engine job phase end
        "
    ::= { jobEngineJobPhaseEnd 7 }


jobEngineJobPolicy OBJECT IDENTIFIER ::= { softwareTraps 21 }

jobEngineJobPolicyInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Job engine job policy
        "
    ::= { jobEngineJobPolicy 7 }


kernVmProcessKilled OBJECT IDENTIFIER ::= { softwareTraps 22 }

kernVmProcessKilledInfo   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Kernel VM process killed
        "
    ::= { kernVmProcessKilled 7 }

kernVmProcessKilledWarn   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Kernel VM process killed
        "
    ::= { kernVmProcessKilled 5 }

kernVmProcessKilledCrit   NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Kernel VM process killed
        "
    ::= { kernVmProcessKilled 3 }

nfsIdentityQueryFailed OBJECT IDENTIFIER ::= { softwareTraps 23 }

nfsIdentityQueryFailedWarn   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "NFS identity query failed
        "
    ::= { nfsIdentityQueryFailed 5 }

nfsIdentityQueryFailedInfo   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "NFS identity query failed
        "
    ::= { nfsIdentityQueryFailed 7 }

nfsIdentityQueryFailedCrit   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "NFS identity query failed
        "
    ::= { nfsIdentityQueryFailed 3 }

auditCeeUnreachable OBJECT IDENTIFIER ::= { softwareTraps 24 }

auditCeeUnreachableWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Audit CEE server is unreachable
        "
    ::= { auditCeeUnreachable 5 }

auditCeeUnreachableCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Audit CEE server is unreachable
        "
    ::= { auditCeeUnreachable 3 }

keyManagerSedsDomainFailed OBJECT IDENTIFIER ::= { softwareTraps 25 }

keyManagerSedsDomainFailedCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Key Manager Init failed for SEDS domain
        "
    ::= { keyManagerSedsDomainFailed 3 }

keyManagerCloudPoolsDomainFailed OBJECT IDENTIFIER ::= { softwareTraps 27 }

keyManagerCloudPoolsDomainFailedCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Key Manager Init failed for cloudpools domain
        "
    ::= { keyManagerCloudPoolsDomainFailed 3 }

avscanNoServersConf OBJECT IDENTIFIER ::= { avscanTraps 1 }

avscanNoServersConfCrit NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "No ICAP servers configured for AVScan
        "
    ::= { avscanNoServersConf 3 }

avscanNoServersConfWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "No ICAP servers configured for AVScan
        "
    ::= { avscanNoServersConf 5 }

avscanNoServersConfInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "No ICAP servers configured for AVScan
        "
    ::= { avscanNoServersConf 7 }

avscanError OBJECT IDENTIFIER ::= { avscanTraps 2 }

avscanErrorCrit NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVscan has encountered an error
        "
    ::= { avscanError 3 }

avscanErrorWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVscan has encountered an error
        "
    ::= { avscanError 5 }

avscanErrorInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVscan has encountered an error
        "
    ::= { avscanError 7 }

avscanInfectedFile OBJECT IDENTIFIER ::= { softwareTraps 3 }

avscanInfectedFileCrit  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVScan found an infected file
        "
    ::= { avscanInfectedFile 3 }

avscanInfectedFileWarn  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVScan found an infected file
        "
    ::= { avscanInfectedFile 5 }

avscanInfectedFileInfo  NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "AVScan found an infected file
        "
    ::= { avscanInfectedFile 7 }

clockSkew   OBJECT IDENTIFIER ::= { netProtoTraps 1 }

clockSkewCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Windows ADS time skew outside limits.
        "
    ::= { clockSkew 3 }

winTimeConnectivityLost OBJECT IDENTIFIER ::= { netProtoTraps 3 }

winTimeConnectivityLostWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Connectivity to the Windows Time server was lost
        "
    ::= { winTimeConnectivityLost 5 }

winNetMapFull   OBJECT IDENTIFIER ::= { netProtoTraps 4 }

winNetMapFullCrit   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Windows ID map range is full.  Authentication may fail.
        "
    ::= { winNetMapFull 3 }

winNetAuth  OBJECT IDENTIFIER ::= { netProtoTraps 5 }

winNetAuthCrit  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Active Directory connectivity failure
        "
    ::= { winNetAuth 3 }

winNetAuthWarn  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Active Directory connectivity issue
        "
    ::= { winNetAuth 5 }

winNetAuthInfo  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Active Directory connectivity failure
        "
    ::= { winNetAuth 7 }

lwioParam       OBJECT IDENTIFIER ::= { netProtoTraps 6 }

lwioParamCrit   NOTIFICATION-TYPE
    OBJECTS     { stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "LWIO Parameter Invalid
        "
    ::= { lwioParam 3 }

winSmbUpgrade   OBJECT IDENTIFIER ::= { netProtoTraps 7 }

winSmbUpgradeWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Windows networking
        "
    ::= { winSmbUpgrade 5 }

winSmbUpgradeCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Windows networking
        "
    ::= { winSmbUpgrade 3 }

winAuthUpgrade OBJECT IDENTIFIER ::= { netProtoTraps 23 }

winAuthUpgradeCrit NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There are problems with upgrading authentication components
        "
    ::= { winAuthUpgrade 3 }

winIDmapRulesParseFail OBJECT IDENTIFIER ::= { netProtoTraps 24 }

winIDmapRulesParseFailCrit NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There are problems with windows ID map rules parsing
        "
    ::= { winIDmapRulesParseFail 3 }

winIDmapRulesParseFailInfo NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There are problems with windows ID map rules parsing
        "
    ::= { winIDmapRulesParseFail 7 }

winIDmapRulesParseFailWarn NOTIFICATION-TYPE
    OBJECTS     { eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There are problems with windows ID map rules parsing
        "
    ::= { winIDmapRulesParseFail 5 }

lwioMemoryThrottling OBJECT IDENTIFIER ::= { netProtoTraps 25 }

lwioMemoryThrottlingCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "LWIO memory throttling
        "
    ::= { lwioMemoryThrottling 3 }

lwioCAThrottling OBJECT IDENTIFIER ::= { netProtoTraps 26 }

lwioCAThrottlingCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "LWIO CA throttling
        "
    ::= { lwioCAThrottling 3 }

netStatus OBJECT IDENTIFIER ::= { networkingTraps 1 }

netStatusCrit NOTIFICATION-TYPE
    OBJECTS     { ifName, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A network interface is down
        "
    ::= { netStatus 3 }

netStatusWarn NOTIFICATION-TYPE
    OBJECTS     { ifName, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A network interface is degraded or down
        "
    ::= { netStatus 5 }

netAggStatus OBJECT IDENTIFIER ::= { networkingTraps 2 }

netAggStatusWarn NOTIFICATION-TYPE
    OBJECTS     { physIfaces, ifName, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A network interface is degraded or down
        "
    ::= { netAggStatus 5 }

netAggStatusCrit NOTIFICATION-TYPE
    OBJECTS     { physIfaces, ifName, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "a network interface is down
        "
    ::= { netAggStatus 3 }

hardwareError OBJECT IDENTIFIER ::= { hardwareTraps 1 }

hardwareErrorMsg OBJECT IDENTIFIER ::= { hardwareError 1 }

hardwareErrorCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A critical hardware error has occurred.
        "
    ::= { hardwareError 3 }

hardwareErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node has a hardware error
        "
    ::= { hardwareError 5 }

hardwareErrorInfo   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A hardware problem is occurring.
        "
    ::= { hardwareError 7 }

hardwareErrorMsgCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There is a message concerning a hardware failure
        "
    ::= { hardwareErrorMsg 3 }

hardwareErrorMsgWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "There is a message concerning a potential hardware failure
        "
    ::= { hardwareErrorMsg 5 }

hwError OBJECT IDENTIFIER ::= { hardwareTraps 2 }

hwErrorCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power Supply AC Failure.
        "
    ::= { hwError 3 }

diskNodeOffline OBJECT IDENTIFIER ::= { hardwareTraps 10 }

diskNodeOfflineCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "The expander is offline
        "
    ::= { diskNodeOffline 3 }

sasPhyErrorExpander OBJECT IDENTIFIER ::= { storageTransportTraps 1 }

sasPhyErrorExpanderCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A SAS PHY error was detected in the expander.
        "
    ::= { sasPhyErrorExpander 3 }

sasPhyErrorExpanderWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A SAS PHY error was detected in the expander.
        "
    ::= { sasPhyErrorExpander 5 }

sasPhyErrorController OBJECT IDENTIFIER ::= { storageTransportTraps 2 }

sasPhyErrorControllerCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A SAS PHY error was detected in the controller.
        "
    ::= { sasPhyErrorController 3 }

sasPhyErrorControllerWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A SAS PHY error was detected in the controller.
        "
    ::= { sasPhyErrorController 5 }

driveStatus OBJECT IDENTIFIER ::= { systemDiskTraps 1 }

driveStatusInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, bay, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node has detected a problem with a drive
        "
    ::= { driveStatus 7 }

driveStatusCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, bay, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node has detected a problem with a drive
        "
    ::= { driveStatus 3 }

driveStatusWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, bay, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node has detected a problem with a drive
        "
    ::= { driveStatus 5 }

bootDiskFail OBJECT IDENTIFIER ::= { systemDiskTraps 2 }

bootDiskFailCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Unhealthy boot disks, mirror is degraded.
        "
    ::= { bootDiskFail 3 }

bootDiskFailWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Unhealthy boot disks, mirror is degraded.
        "
    ::= { bootDiskFail 5 }

diskError OBJECT IDENTIFIER ::= { systemDiskTraps 3 }

diskErrorWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's disks are having problems
        "
    ::= { diskError 5 }

bootDiskMirrorReqMissing OBJECT IDENTIFIER ::= { systemDiskTraps 4 }

bootdiskMirrorReqMissingCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Error creating mirror on bootdisks.
        "
    ::= { bootDiskMirrorReqMissing 3 }

bootDiskNotSup OBJECT IDENTIFIER ::= { systemDiskTraps 21 }

bootDiskNotSupCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A boot disk is not supported
        "
    ::= { bootDiskNotSup 3 }

hwPwrSupply OBJECT IDENTIFIER ::= { sensorTraps 1 }
hwPwrSupplyOver OBJECT IDENTIFIER ::= { hwPwrSupply 1 }

hwPwrSupplyOverCrit NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply current over critical threshold
        "
    ::= { hwPwrSupplyOver 3 }

hwPwrSupplyOverWarn NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply current over warning threshold
        "
    ::= { hwPwrSupplyOver 5 }

hwPwrSupplyUnder OBJECT IDENTIFIER ::= { hwPwrSupply 2 }

hwPwrSupplyUnderCrit    NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply current under critical threshold
        "
    ::= { hwPwrSupplyUnder 3 }

hwPwrSupplyUnderWarn    NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply current under warning threshold
        "
    ::= { hwPwrSupplyUnder 5 }

hwFan OBJECT IDENTIFIER ::= { sensorTraps 2 }
hwFanOver OBJECT IDENTIFIER ::= { hwFan 1 }

hwFanOverCrit   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's fan is over critical threshold
        "
    ::= { hwFanOver 3 }

hwFanOverWarn   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's fan is over warning threshold
        "
    ::= { hwFanOver 5 }

hwFanUnder OBJECT IDENTIFIER ::= { hwFan 2 }

hwFanUnderCrit  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's fan is under critical threshold
        "
    ::= { hwFanUnder 3 }

hwFanUnderWarn  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's fan is under warning threshold
        "
    ::= { hwFanUnder 5 }

hwFanCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's fan failed
        "
    ::= { hwFan 3 }

hwVoltage OBJECT IDENTIFIER ::= { sensorTraps 10 }
hwVoltageOver OBJECT IDENTIFIER ::= { hwVoltage 1 }

hwVoltageOverCrit   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is over critical threshold
        "
    ::= { hwVoltageOver 3 }

hwVoltageOverWarn   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is over warning threshold
        "
    ::= { hwVoltageOver 5 }

hwVoltageOverInfo   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is over a threshold
        "
    ::= { hwVoltageOver 7 }

hwVoltageUnder OBJECT IDENTIFIER ::= { hwVoltage 2 }

hwVoltageUnderCrit  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is under critical threshold
        "
    ::= { hwVoltageUnder 3 }

hwVoltageUnderWarn  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is under warning threshold
        "
    ::= { hwVoltageUnder 5 }

hwVoltageUnderInfo  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's voltage is under a threshold
        "
    ::= { hwVoltageUnder 7 }

hwTemp OBJECT IDENTIFIER ::= { sensorTraps 11 }
hwTempOver OBJECT IDENTIFIER ::= { hwTemp 1 }

hwTempOverEmerg NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is over emergency threshold
        "
    ::= { hwTempOver 1 }

hwTempOverCrit  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is over critical threshold
        "
    ::= { hwTempOver 3 }

hwTempOverWarn  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is over warning threshold
        "
    ::= { hwTempOver 5 }

hwTempOverInfo  NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is over a threshold
        "
    ::= { hwTempOver 7 }

hwTempUnder OBJECT IDENTIFIER ::= { hwTemp 2 }

hwTempUnderEmerg    NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is under emergency threshold
        "
    ::= { hwTempUnder 1 }

hwTempUnderCrit NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is under critical threshold
        "
    ::= { hwTempUnder 3 }

hwTempUnderWarn NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is under warning threshold
        "
    ::= { hwTempUnder 5 }

hwTempUnderInfo NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node's temperature is under a threshold
        "
    ::= { hwTempUnder 7 }

hwPower OBJECT IDENTIFIER ::= { sensorTraps 12 }

hwPowerCrit NOTIFICATION-TYPE
    OBJECTS     { stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node has a power supply problem
        "
    ::= { hwPower 3 }

hwMem OBJECT IDENTIFIER ::= { sensorTraps 13 }

hwMemCrit   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node is low on memory
        "
    ::= { hwMem 3 }

hwCpuThrottle OBJECT IDENTIFIER ::= { sensorTraps 14 }

hwCpuThrottleCrit   NOTIFICATION-TYPE
    OBJECTS     { measuredValueStr, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A node is at 100% CPU utilization
        "
    ::= { hwCpuThrottle 3 }

sensorMonitor OBJECT IDENTIFIER ::= { sensorTraps 15 }

sensorMonitorCrit   NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A sensor failed
        "
    ::= { sensorMonitor 3 }

sensorMonitorWarn   NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A sensor is failing
        "
    ::= { sensorMonitor 5 }

hwIPMI OBJECT IDENTIFIER ::= { sensorTraps 17 }
hwIPMIOther OBJECT IDENTIFIER ::= { hwIPMI 1 }

hwIPMIOtherErrorEmerg  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An IPMI event is over emergency threshold
        "
    ::= { hwIPMIOther 1 }

hwIPMIOtherErrorCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An IPMI event is over critical threshold
        "
    ::= { hwIPMIOther 3 }

hwIPMIOtherErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An IPMI event is over warning threshold
        "
    ::= { hwIPMIOther 5 }

hwIPMIOtherErrorInfo   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An IPMI event is over a threshold
        "
    ::= { hwIPMIOther 7 }

hwIPMIFan OBJECT IDENTIFIER ::= { hwIPMI 2 }

hwIPMIFanErrorEmerg  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A fan is over emergency threshold
        "
    ::= { hwIPMIFan 1 }

hwIPMIFanErrorCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A fan is over critical threshold
        "
    ::= { hwIPMIFan 3 }

hwIPMIFanErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A fan is over warning threshold
        "
    ::= { hwIPMIFan 5 }

hwIPMIFanErrorInfo   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A fan is over a threshold
        "
    ::= { hwIPMIFan 7 }

hwIPMIVoltage OBJECT IDENTIFIER ::= { hwIPMI 3 }

hwIPMIVoltageErrorEmerg  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, stringArg, measuredValueStr, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A voltage is over emergency threshold
        "
    ::= { hwIPMIVoltage 1 }

hwIPMIVoltageErrorCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, stringArg, measuredValueStr, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A voltage is over critical threshold
        "
    ::= { hwIPMIVoltage 3 }

hwIPMIVoltageErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, stringArg, measuredValueStr, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A voltage is over warning threshold
        "
    ::= { hwIPMIVoltage 5 }

hwIPMIVoltageErrorInfo   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, stringArg, measuredValueStr, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A voltage is over a threshold
        "
    ::= { hwIPMIVoltage 7 }

hwIPMITemp OBJECT IDENTIFIER ::= { hwIPMI 4 }

hwIPMITempErrorEmerg  NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Temperature is over emergency threshold
        "
    ::= { hwIPMITemp 1 }

hwIPMITempErrorCrit   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Temperature is over critical threshold
        "
    ::= { hwIPMITemp 3 }

hwIPMITempErrorWarn   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Temperature is over warning threshold
        "
    ::= { hwIPMITemp 5 }

hwIPMITempErrorInfo   NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, measuredValueStr, stringArg, i32Arg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Temperature is over a threshold
        "
    ::= { hwIPMITemp 7 }

hwInfinity OBJECT IDENTIFIER ::= { sensorTraps 19 }

hwInfinityNtbLinkOutage OBJECT IDENTIFIER ::= { hwInfinity 1 }

hwInfinityNtbLinkOutageCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An NTB link outage event is over critical threshold.
        "
    ::= { hwInfinityNtbLinkOutage 3 }

hwInfinityNtbLinkOutageWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An NTB link outage event is over warning threshold.
        "
    ::= { hwInfinityNtbLinkOutage 5 }

hwInfinityNtbLinkOutageInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An NTB link outage event is over a threshold.
        "
    ::= { hwInfinityNtbLinkOutage 7 }

hwInfinityMnviProtoError OBJECT IDENTIFIER ::= { hwInfinity 2 }

hwInfinityMnviProtoErrorWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Mirror Journal can not connect to peer node.
        "
    ::= { hwInfinityMnviProtoError 5 }

hwInfinityComputeFault  OBJECT IDENTIFIER ::= { hwInfinity 3 }

hwInfinityComputeFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A compute node fault detected.
        "
    ::= { hwInfinityComputeFault 5 }

hwInfinityDimmFault OBJECT IDENTIFIER ::= { hwInfinity 4 }

hwInfinityDimmFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "A DIMM fault detected.
        "
    ::= { hwInfinityDimmFault 5 }

hwInfinityAdaptiveCooling OBJECT IDENTIFIER ::= { hwInfinity 5 }

hwInfinityAdaptiveCoolingWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Adaptive cooling event detected.
        "
    ::= { hwInfinityAdaptiveCooling 5 }

hwInfinityFanFault OBJECT IDENTIFIER ::= { hwInfinity 6 }

hwInfinityFanFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Fan fault detected.
        "
    ::= { hwInfinityFanFault 5 }

hwInfinityPowerSupplyFault OBJECT IDENTIFIER ::= { hwInfinity 7 }

hwInfinityPowerSupplyFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply fault detected.
        "
    ::= { hwInfinityPowerSupplyFault 5 }

hwInfinityBatteryBackupFault OBJECT IDENTIFIER ::= { hwInfinity 8 }

hwInfinityBatteryBackupFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Battery Backup Unit fault detected.
        "
    ::= { hwInfinityBatteryBackupFault 5 }

hwInfinityM2DriveFault OBJECT IDENTIFIER ::= { hwInfinity 9 }

hwInfinityM2DriveFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Internal M.2 drive fault detected.
        "
    ::= { hwInfinityM2DriveFault 5 }

hwInfinityIOModuleFault OBJECT IDENTIFIER ::= { hwInfinity 10 }

hwInfinityIOModuleFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "IO module fault detected.
        "
    ::= { hwInfinityIOModuleFault  5 }

hwInfinityInternalfault OBJECT IDENTIFIER ::= { hwInfinity 11 }

hwInfinityInternalfaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Internal fault detected.
        "
    ::= { hwInfinityInternalfault  5 }

hwInfinityExternalFault OBJECT IDENTIFIER ::= { hwInfinity 12 }

hwInfinityExternalFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "External fault detected.
        "
    ::= { hwInfinityExternalFault  5 }

hwInfinityNtbPciFault OBJECT IDENTIFIER ::= { hwInfinity 13 }

hwInfinityNtbPciFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Non-transparent bridge fault detected.
        "
    ::= { hwInfinityNtbPciFault  5 }

hwInfinityI2cFault OBJECT IDENTIFIER ::= { hwInfinity 14 }

hwInfinityI2cFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "I2C fault detected.
        "
    ::= { hwInfinityI2cFault  5 }

hwInfinityDIBFault OBJECT IDENTIFIER ::= { hwInfinity 15 }

hwInfinityDIBFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Drive interface board fault detected.
        "
    ::= { hwInfinityDIBFault  5 }

hwInfinityMidplaneFault OBJECT IDENTIFIER ::= { hwInfinity 16 }

hwInfinityMidplaneFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Drive interface board fault detected.
        "
    ::= { hwInfinityMidplaneFault  5 }

hwInfinityPmpFailure OBJECT IDENTIFIER ::= { hwInfinity 17 }

hwInfinityPmpFailureWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Unable to restore journal after powering up the node.
        "
    ::= { hwInfinityPmpFailure  5 }

hwInfinityPowerRedundancyFault OBJECT IDENTIFIER ::= { hwInfinity 18 }

hwInfinityPowerRedundancyFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Power supply redundancy fault.
        "
    ::= { hwInfinityPowerRedundancyFault  5 }

hwInfinityArmPmpFailure OBJECT IDENTIFIER ::= { hwInfinity 19 }

hwInfinityArmPmpFailureWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Journal protection in the event of a power failure not enabled.
        "
    ::= { hwInfinityArmPmpFailure  5 }

hwInfinityCorrectedHwError OBJECT IDENTIFIER ::= { hwInfinity 20 }

hwInfinityCorrectedHwErrorWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        " A hardware error was corrected.
        "
    ::= { hwInfinityCorrectedHwError  5 }

hwInfinityLocalBmcFault OBJECT IDENTIFIER ::= { hwInfinity 21 }

hwInfinityLocalBmcFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        " Local Baseboard Management Controller unresponsive.
        "
    ::= { hwInfinityLocalBmcFault 5 }

hwInfinityPeerBmcFault OBJECT IDENTIFIER ::= { hwInfinity 22 }

hwInfinityPeerBmcFaultWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        " Peer Baseboard Management Controller unresponsive.
        "
    ::= { hwInfinityPeerBmcFault 5 }

hwInfinityJmStateError OBJECT IDENTIFIER ::= { hwInfinity 23 }

hwInfinityJmStateErrorWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        " Local journal not in protected state.
        "
    ::= { hwInfinityJmStateError 5 }

hwInfinityDelayedReboot OBJECT IDENTIFIER ::= { hwInfinity 24 }

hwInfinityDelayedRebootCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, errorMessage, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        " Delayed reboot event detected.
        "
    ::= { hwInfinityDelayedReboot 3 }

cloudpoolNetworkError OBJECT IDENTIFIER ::= { cloudPoolsTraps 1 }

cloudpoolNetworkErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, deviceIdentifier, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools network issues
        "
    ::= { cloudpoolNetworkError 3 }

cloudpoolAuthenticationError OBJECT IDENTIFIER ::= { cloudPoolsTraps 2 }

cloudpoolAuthenticationErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools authentication issues
        "
    ::= { cloudpoolAuthenticationError 3 }

cloudpoolAuthorizationError OBJECT IDENTIFIER ::= { cloudPoolsTraps 3 }

cloudpoolAuthorizationErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools authorization issues
        "
    ::= { cloudpoolAuthorizationError 3 }

cloudpoolBucketNotFoundError OBJECT IDENTIFIER ::= { cloudPoolsTraps 4 }

cloudpoolBucketNotFoundErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools bucket not found issues
        "
    ::= { cloudpoolBucketNotFoundError 3 }

cloudpoolObjectNotFoundError OBJECT IDENTIFIER ::= { cloudPoolsTraps 5 }

cloudpoolObjectNotFoundErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools Object not found issues
        "
    ::= { cloudpoolObjectNotFoundError 3 }

cloudpoolDataCorruptionIntegrityError OBJECT IDENTIFIER ::= { cloudPoolsTraps 6 }

cloudpoolDataCorruptionIntegrityErrorEmerg  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools data corruption integrity emergency issues
        "
    ::= { cloudpoolDataCorruptionIntegrityError 1 }


cloudpoolNoUsableAccountFoundError OBJECT IDENTIFIER ::= { cloudPoolsTraps 7 }

cloudpoolNoUsableAccountFoundErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools no usable account found for the policy, cloudpool
        "
    ::= { cloudpoolNoUsableAccountFoundError 3 }

cloudpoolCertificateError OBJECT IDENTIFIER ::= { cloudPoolsTraps 8 }

cloudpoolCertificateErrorCrit  NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, errorMessage, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "CloudPools Certificate issues
        "
    ::= { cloudpoolCertificateError 3 }

upgradeStart OBJECT IDENTIFIER ::= { upgradeTraps 1 }

upgradeStartInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An upgrade or rollback has been started."
    ::= { upgradeStart 7 }

upgradeFinish OBJECT IDENTIFIER ::= { upgradeTraps 2 }

upgradeFinishInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "An upgrade or rollback has finished."
    ::= { upgradeFinish 7 }

upgradeClusterEvent OBJECT IDENTIFIER ::= { upgradeTraps 3 }

upgradeClusterEventCrit NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade cluster event."
    ::= { upgradeClusterEvent 3 }

upgradeClusterEventWarn NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade cluster event."
    ::= { upgradeClusterEvent 5 }

upgradeClusterEventInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade cluster event."
    ::= { upgradeClusterEvent 7 }

upgradeNodeEvent OBJECT IDENTIFIER ::= { upgradeTraps 4 }

upgradeNodeEventCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade node event."
    ::= { upgradeNodeEvent 3 }

upgradeNodeEventWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade node event."
    ::= { upgradeNodeEvent 5 }

upgradeNodeEventInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade node event."
    ::= { upgradeNodeEvent 7 }

upgradeRollbackStart OBJECT IDENTIFIER ::= { upgradeTraps 5 }

upgradeRollbackStartInfo NOTIFICATION-TYPE
    OBJECTS     { stringArg, stringArg, stringArg, stringArg, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Upgrade rollback start."
    ::= { upgradeRollbackStart 7 }

celogHeartBeatEvent OBJECT IDENTIFIER ::= { celogTraps 1 }

celogHeartBeatEventCrit NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Critical Heartbeat Event."
    ::= { celogHeartBeatEvent 3 }

celogHeartBeatEventWarn NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Warning Heartbeat Event."
    ::= { celogHeartBeatEvent 5 }

celogHeartBeatEventInfo NOTIFICATION-TYPE
    OBJECTS     { nodeIdentifier, nodeName, nodeSerialNumber, eventKbUrl, instanceIdentifier, eventId, eventIdName }
    STATUS      current
    DESCRIPTION
        "Warning Heartbeat Event."
    ::= { celogHeartBeatEvent 7 }

-- Conformance groups --

groupStateTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        nodeStatusCrit,
        nodeStatusInfo,
        nodeShutdownInfo,
        nodeShutdownFailCrit}
    STATUS current
    DESCRIPTION
        "Collection of traps for group state."
    ::= { trapConformance 1 }

filesystemTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        partitionUsageCrit,
        partitionUsageWarn,
        partitionUsageInfo,
        filesysErrorCrit,
        filesysErrorWarn,
        filesysErrorInfo,
        diskPoolUsageCrit,
        diskPoolUsageWarn,
        diskPoolOldDbVersionWarn,
        ssdUsageCrit,
        ssdUsageWarn,
        ssdUsageInfo}
    STATUS current
    DESCRIPTION
        "Collection of filesystem traps."
    ::= { trapConformance 11 }

smartQuotaTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        quotaThreshErrorInfo,
        quotaNotifyErrorWarn,
        quotaErrorWarn }
    STATUS current
    DESCRIPTION
        "Collection of smartQuota traps."
    ::= { trapConformance 12 }

snapshotTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        snapshotErrorWarn,
        snapshotReserveCrit,
        snapshotReserveWarn }
    STATUS current
    DESCRIPTION
        "Collection of snapshot traps."
    ::= { trapConformance 13 }

syncIQTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        siqErrorCrit,
        siqErrorWarn,
        siqErrorInfo}
    STATUS current
    DESCRIPTION
        "Collection of syncIQ traps."
    ::= { trapConformance 14 }

softwareTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        jobEngineErrorEmerg,
        jobEngineErrorCrit,
        jobEngineErrorWarn,
        jobEngineErrorInfo,
        flexProtectRunningCrit,
        flexProtectRunningWarn,
        flexProtectRunningInfo,
        mcpProcFailedWarn,
        mcpProcKilledWarn,
        licenseExpirationWarn,
        licenseExpirationInfo,
        licenseActivationIncompleteWarn,
        licenseEntitlementsExceededWarn,
        firmwareUpdateIncompleteWarn,
        testEventCrit,
        mountdClientMountFailedInfo,
        mountdHostLookupFailedInfo,
        nfsCookieTranslationFailedInfo,
        mixedSedNonSedClusterWarn,
        suggestedProtectionWarn,
        unprovisionedNodeWarn,
        underprovisionedNodePoolWarn,
        testEvent2Crit,
        testEvent2Warn,
        testEvent2Info,
        checkClusterCrit,
        checkClusterWarn,
        checkClusterInfo,
        clusterMonthlyStatusInfo,
        clusterMonthlyStatusWarn,
        clusterMonthlyStatusCrit,
        jobEngineJobStateInfo,
        jobEngineJobPhaseBeginInfo,
        jobEngineJobPhaseEndInfo,
        jobEngineJobPolicyInfo,
        kernVmProcessKilledInfo,
        kernVmProcessKilledWarn,
        kernVmProcessKilledCrit,
        nfsIdentityQueryFailedWarn,
        nfsIdentityQueryFailedInfo,
        nfsIdentityQueryFailedCrit,
        auditCeeUnreachableWarn,
        auditCeeUnreachableCrit,
        keyManagerSedsDomainFailedCrit,
        keyManagerCloudPoolsDomainFailedCrit}
    STATUS current
    DESCRIPTION
        "Collection of software traps."
    ::= { trapConformance 15 }

avscanTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        avscanNoServersConfCrit,
        avscanNoServersConfWarn,
        avscanNoServersConfInfo,
        avscanErrorCrit,
        avscanErrorWarn,
        avscanErrorInfo,
        avscanInfectedFileCrit,
        avscanInfectedFileWarn,
        avscanInfectedFileInfo}
    STATUS current
    DESCRIPTION
        "Collection of avscan traps."
    ::= { trapConformance 16 }

netProtoTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        clockSkewCrit,
        winTimeConnectivityLostWarn,
        winNetMapFullCrit,
        winNetAuthCrit,
        winNetAuthWarn,
        winNetAuthInfo,
        lwioParamCrit,
        winSmbUpgradeWarn,
        winSmbUpgradeCrit,
        winAuthUpgradeCrit,
        winIDmapRulesParseFailCrit,
        winIDmapRulesParseFailInfo,
        winIDmapRulesParseFailWarn,
        lwioMemoryThrottlingCrit,
        lwioCAThrottlingCrit}
    STATUS current
    DESCRIPTION
        "Collection of net protocol traps."
    ::= { trapConformance 17 }

networkingTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        netStatusCrit,
        netStatusWarn,
        netAggStatusWarn,
        netAggStatusCrit}
    STATUS current
    DESCRIPTION
        "Collection of networking traps."
    ::= { trapConformance 18 }

hardwareTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        hardwareErrorMsgCrit,
        hardwareErrorMsgWarn,
        hardwareErrorCrit,
        hardwareErrorWarn,
        hardwareErrorInfo,
        hwErrorCrit,
        diskNodeOfflineCrit}
    STATUS current
    DESCRIPTION
        "Collection of sensor traps."
    ::= { trapConformance 19 }

systemDiskTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        driveStatusInfo,
        driveStatusCrit,
        driveStatusWarn,
        bootDiskFailCrit,
        bootDiskFailWarn,
        diskErrorWarn,
        bootdiskMirrorReqMissingCrit,
        bootDiskNotSupCrit }
    STATUS current
    DESCRIPTION
        "Collection of system disk traps."
    ::= { trapConformance 20 }

sensorTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        hwPwrSupplyOverCrit,
        hwPwrSupplyOverWarn,
        hwPwrSupplyUnderCrit,
        hwPwrSupplyUnderWarn,
        hwFanOverCrit,
        hwFanOverWarn,
        hwFanUnderCrit,
        hwFanUnderWarn,
        hwVoltageOverCrit,
        hwVoltageOverWarn,
        hwVoltageOverInfo,
        hwVoltageUnderCrit,
        hwVoltageUnderWarn,
        hwVoltageUnderInfo,
        hwTempOverEmerg,
        hwTempOverCrit,
        hwTempOverWarn,
        hwTempOverInfo,
        hwTempUnderEmerg,
        hwTempUnderCrit,
        hwTempUnderWarn,
        hwTempUnderInfo,
        hwPowerCrit,
        hwMemCrit,
        hwFanCrit,
        hwCpuThrottleCrit,
        sensorMonitorCrit,
        sensorMonitorWarn,
        hwIPMIOtherErrorEmerg,
        hwIPMIOtherErrorCrit,
        hwIPMIOtherErrorWarn,
        hwIPMIOtherErrorInfo,
        hwIPMIFanErrorEmerg,
        hwIPMIFanErrorCrit,
        hwIPMIFanErrorWarn,
        hwIPMIFanErrorInfo,
        hwIPMIVoltageErrorEmerg,
        hwIPMIVoltageErrorCrit,
        hwIPMIVoltageErrorWarn,
        hwIPMIVoltageErrorInfo,
        hwIPMITempErrorEmerg,
        hwIPMITempErrorCrit,
        hwIPMITempErrorWarn,
        hwIPMITempErrorInfo,
        hwInfinityNtbLinkOutageCrit,
        hwInfinityNtbLinkOutageWarn,
        hwInfinityNtbLinkOutageInfo,
        hwInfinityMnviProtoErrorWarn,
        hwInfinityComputeFaultWarn,
        hwInfinityDimmFaultWarn,
        hwInfinityAdaptiveCoolingWarn,
        hwInfinityFanFaultWarn,
        hwInfinityPowerSupplyFaultWarn,
        hwInfinityBatteryBackupFaultWarn,
        hwInfinityM2DriveFaultWarn,
        hwInfinityIOModuleFaultWarn,
        hwInfinityInternalfaultWarn,
        hwInfinityExternalFaultWarn,
        hwInfinityNtbPciFaultWarn,
        hwInfinityI2cFaultWarn,
        hwInfinityDIBFaultWarn,
        hwInfinityMidplaneFaultWarn,
        hwInfinityPmpFailureWarn,
        hwInfinityArmPmpFailureWarn,
        hwInfinityCorrectedHwErrorWarn,
        hwInfinityLocalBmcFaultWarn,
        hwInfinityPeerBmcFaultWarn,
        hwInfinityJmStateErrorWarn,
        hwInfinityDelayedRebootCrit}
    STATUS current
    DESCRIPTION
        "Collection of sensor traps."
    ::= { trapConformance 21 }

storageTransportTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        sasPhyErrorExpanderCrit,
        sasPhyErrorExpanderWarn,
        sasPhyErrorControllerCrit,
        sasPhyErrorControllerWarn}
    STATUS current
    DESCRIPTION
        "Collection of storage transport traps."
    ::= { trapConformance 22 }

cloudPoolsTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        cloudpoolNetworkErrorCrit,
        cloudpoolAuthenticationErrorCrit,
        cloudpoolAuthorizationErrorCrit,
        cloudpoolBucketNotFoundErrorCrit,
        cloudpoolObjectNotFoundErrorCrit,
        cloudpoolDataCorruptionIntegrityErrorEmerg,
        cloudpoolNoUsableAccountFoundErrorCrit,
        cloudpoolCertificateErrorCrit }
    STATUS current
    DESCRIPTION
        "Collection of cloud pools traps."
    ::= { trapConformance 23 }

upgradeTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        upgradeStartInfo,
        upgradeFinishInfo,
        upgradeClusterEventCrit,
        upgradeClusterEventWarn,
        upgradeClusterEventInfo,
        upgradeNodeEventCrit,
        upgradeNodeEventWarn,
        upgradeNodeEventInfo,
        upgradeRollbackStartInfo }
    STATUS current
    DESCRIPTION
        "Collection of upgrade traps."
    ::= { trapConformance 24 }

variablesGroup OBJECT-GROUP
    OBJECTS {
        nodeIdentifier,
        measuredValue,
        units,
        oid,
        bay,
        ifName,
        phy,
        errorMessage,
        errno,
        stringArg,
        message,
        i64Arg,
        i32Arg,
        measuredValueStr,
        instanceIdentifier,
        deviceIdentifier,
        physIfaces,
        eventKbUrl,
        eventId,
        eventIdName }
    STATUS current
    DESCRIPTION
        "Collection of variable traps."
    ::= { trapConformance 50 }

celogTrapsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        celogHeartBeatEventCrit,
        celogHeartBeatEventWarn,
        celogHeartBeatEventInfo}
    STATUS current
    DESCRIPTION
        "Collection of CELOG specific traps."
    ::= { trapConformance 25 }

trapGroupCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
        "Compliance statement for the Isilon traps."
    MODULE
        MANDATORY-GROUPS {
            groupStateTrapsGroup,
            filesystemTrapsGroup,
            smartQuotaTrapsGroup,
            snapshotTrapsGroup,
            syncIQTrapsGroup,
            softwareTrapsGroup,
            avscanTrapsGroup,
            netProtoTrapsGroup,
            networkingTrapsGroup,
            hardwareTrapsGroup,
            systemDiskTrapsGroup,
            sensorTrapsGroup,
            storageTransportTrapsGroup,
            cloudPoolsTrapsGroup,
            upgradeTrapsGroup,
            variablesGroup }
    ::= { trapCompliance 1 }

END

-- vim: set filetype=mib tabstop=4 expandtab nospell :miv --