Dell PowerVault MD Series Storage Array Resource DVD version 4.1.0.88 Introduction This readme file contains important information regarding the MD Series Storage Arrays and should be read in its entirety. NOTE: It is critical that all appropriate sections of the documentation are read prior to deployment of the MD Series Storage Arrays. Upgrading the Software and Firmware To upgrade from a previous version of the MD Storage Manager application, uninstall the previous version of the Resource DVD, then install the new version of the Resource DVD. For detailed instructions,refer to the Deployment Guide. Before upgrading the controller firmware back up all data on your storage array and select Gather support Information from the Support tab in MD Storage Manager to save diagnostic and status data to a compressed file. Alternately, you can use the 'save storageArray supportData file="filename"' SMcli command to collect your support data. See the Owner's Manual for detailed firmware upgrade instructions. Viewing the Documentation To obtain the latest documentation, go to support.dell.com/manuals. The View Documentation option link in the Resource DVD installer provides additional instructions on how to access the documentation via your storage array Service Tag or product model. Software Versions on this Resource DVD Modular Disk Storage Manager 10.84.x6.25 10.84.x6.25 1280x1024 video resolution is recommended for the MD Storage Manager. Virtual Disk Service (VDS) Provider: D0.84.G6.02 Volume Shadow-Copy Server (VSS) Provider: S0.84.G6.02 Release Notes - On the Red Hat Enterprise Linux 5 operating system, DVDs are auto-mounted with the -noexec mount option. This option does not allow you to run any executables from the DVD. To fix this problem, you need to unmount the DVD, manually re-mount the DVD, and then run executables. The command to unmount the DVD is # umount The command to manually mount DVD is # mount - Operating System support for autorun varies. If the software does not automatically launch when the DVD is inserted, it must be manually invoked with one of the following commands in the root directory of the DVD: Linux: ./autorun Windows: md_launcher.exe - On the Red Hat Enterprise Linux 6 operating system, before you run the silent install command, make sure to run the following script from the Resource DVD to install prerequisite packages. # md_prereq_install.sh # linux_hostnameupdates.sh - Write cache is now offloaded to non-volatile memory in the event of power loss. Repeated power losses will result in battery depletion forcing write cache to be disabled. - Single path root boot is supported on all Linux OS versions. - Linux based system multipath support has changed from MPP to DM (Device Mapper) for MD32x0, MD32x0i, MD36x0i and MD36x0f. On MD3000/i, MPP is still used. MPP and DM can coexist on the same host. - By default, the RAID controller management ports are configured using a DHCP server. If a DHCP server does not respond within 190 seconds, the RAID controller management ports are configured with the following default IP addresses: 192.168.128.101 for controller 0 and 192.168.128.102 for controller 1. - Under Windows, once you have created and assigned a virtual disk to your system, you need to partition and format it using the Disk Management MMC located in Settings -> Control Panel -> Administrative Tools or Control Panel -> Administrative Tools before you can use the virtual disk. In addition, you can configure the virtual disk by right clicking on My Computer, then selecting Manage->Storage->Disk Management. This method works for both Windows 2003 and Windows 2008. - On Red Hat Enterprise Linux 5, libXP (deprecated in RHEL5) is required for the management application to run. This should be automatically installed as part of the Linux install process. - Autodiscovery with IPv6 does not reliably detect management ports with Windows 2003. To ensure the ports are set up properly in Windows 2003, manually enter the IPv6 addresses. - The Virtual Disk Service (VDS) Provider is not supported on the Core versions of Windows 2008 and Windows 2008 R2. - The Virtual Disk Service (VDS) Provider supports two interface versions for Windows 2008 R2:version 1.1 and 3.0. By default, the installer software installs VDS Interface v1.1. If you need to install VDS Interface version 3.0 on the server, please refer to the windows\providers directory on the Resource DVD. - If VDS version 3.0 is installed on Windows Server 2008 R2 operating systems, supported LUN types are not listed in the Provision Storage wizard (Start > Administrative Tools > Share and Storage Management). As a result, you cannot create a new LUN using this wizard. VDS version 1.1 (installed by default by the MD series Resource DVD) supports display of supported LUN types in the Provision Storage wizard. - On Linux, the multipathd daemon is not automatically stopped or removed as a startup service during software uninstallation of the Resource DVD. This is to prevent issues with any other devices that may currently be making use of the multipathd daemon. If no other devices are using multipathd, you may wish to manually stop it and remove it from system startup using the following command: # chkconfig multipathd off - Windows versions other than Windows 2008 R2 do not query the Dell Device Specific Module (DSM) for supported load balancing policies. As a result, additional unsupported policies are displayed. However only the following three load balancing policies are supported: Round Robin With Subset Least Queue Depth Weighted Paths - If using in-band management, do not change the IP addresses of the iSCSI host (data) ports. - For videos on the entire Dell PowerVault MD product line, go to del.ly/PowerVaultMD - ALUA support is on ESX 4.1 ESXi 5.0, RHEL 6.2 and SLES 11.2. - On the SuSE Linux Enterprise 11 operating system, before you run the silent install command, make sure to run the following script from the Resource DVD to install prerequisite packages. # linux_hostnameupdates.sh Known Issues - Heavy CPU usage on Linux host may result in extended failback time. - The 'multipath' command on a Linux host with heavy CPU usage may take an extended time to complete. - After searching online help pages in MD Storage Manager GUI, the search topic may not be highlighted if the Previous or Next button is used. - When doing Mutual CHAP authentication under the Linux environment, the "username" and "username_in" fields need to be populated with the same value. The "username" value is not validated by the target but it is reflected back to the initiator to validate against the "username_in" field. - For ESX deployment procedure, refer to ESX Deployment Guide for your model at www.dell.com/pvresources. - When managing a MD3000/MD3000i with Modular Disk Storage Manager, some controls may appear stacked. This issue can be resolved by minimizing and maximizing the window. - When managing MD Storage arrays with Modular Disk Storage Manager or Modular Disk Configuration Utility, some buttons may not be visible(off-screen) under a resolution of 1024x768. The issue can be resolved by increasing the screen resolution to a minimum of 1280x1024. - Linux systems using Device Mapper with a large number of LUN mappings may encounter a scenario where the first discovered path is not the path to the Virtual Disk's preferred controller. As a result, the Virtual Disk may be transferred to a non-preferred path and generate an associated warning in the Modular Disk Storage Manager software. Since an actual failover event likely did not occur in this case, automatic failback may not take place. This issue may be resolved by manually rebalancing the Virtual Disks to their preferred controllers via the Modular Disk Storage Manager software once the host system has completed discovery of all LUN mappings. - Modular Disk Storage Manager may not provide a popup to indicate that a dynamic capacity expansion (DCE) operation has failed when the background media scan option is enabled. A Major Event Log entry will be provided (MEL 2266 'Virtual Disk Modification Failed'). Review the Major Event Log after DCE operations to ensure no errors occurred. - When deleting an iSCSI session with Modular Disk Configuration Utility, the operation may fail indicating that the device is busy. Stop the MD Storage Manager Agent, then try the operation again. Restart the agent after the operation is complete. - After uninstalling Dell Storage Software the item may persist in the Add/Remove Programs list. To remove the item from the list, select the application from the list and press the Uninstall/Change button. When an error message appears, select Yes to remove the item from the list. Required Patches The installation process automatically installs several hotfixes / patches that are required for Windows and Linux depending on the chosen install options. For a complete list of the Windows platforms and their applicable patches, refer to the support matrix at support.dell.com/manuals. Additional Features The autorun script in the root of the DVD will automatically detect when a Linux system is running in console mode and launch the installation in console mode. This allows the software to be installed on Linux systems without X-Windows installed. However, some components such as Modular Disk Storage Manager still require a graphical environment to operate. The installation program also supports silent mode. See the Deployment Guide for more information about configuring and using silent mode installations. Best Practices Always "Gather Support Information" and save it before and after any configuration change. This can be done through MD Storage Manager by clicking on the "Support" tab and then selecting "Gather Support Information". Select a file where the information will be saved. This information is required to expedite the resolution of support calls. It is required to transfer the ownership of virtual disks owned by RAID controller module 1 to RAID controller module 0 before taking RAID controller module 1 off-line. (or vice versa) Bug Fixes The start up bug that affected MDSM initialization on RedHat 6.x has been fixed. This was related to the /etc/hosts file not updating itself with hostname and IPAddress Deprecated DM names have been removed from multipath.conf which were earlier causing errors on RHEL 6.x OS Copyright Information in this document is subject to change without notice. (c) 2010-2012 Dell Inc. Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: "Dell", "Dell PowerVault", the DELL logo, "PowerEdge", and "PowerVault" are trademarks of Dell Inc.; "Microsoft", "Windows", "Windows 2003", "Windows XP", "Windows Vista", and "Windows Server 2008" are registered trademarks of Microsoft Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than their own.