####################################################################### DELL OPENMANAGE(TM) Array Manager, VERSION 3.7 README ####################################################################### ====================================================================== Criticality ====================================================================== 2 - Recommended ====================================================================== Title and Description ====================================================================== Array Manager is designed for system administrators who implement hardware and software RAID solutions and understand corporate and small business storage environments. Array Manager enables you to configure the storage components attached to your system. These components include RAID and non-RAID controllers and the channels, enclosures, and disks attached to them. Using Array Manager, you can implement controller functions without requiring access to the BIOS. This readme file contains updated information for Array Manager Version 3.7. Always see the Dell support Website at support.dell.com for the most current information. ###################################################################### README TABLE OF CONTENTS ###################################################################### COMPATIBILITY/RECOMMENDED REQUIREMENTS WARNINGS WHAT IS NEW IN THIS RELEASE? WHAT IS FIXED IN THIS RELEASE? INSTALLING ARRAY MANAGER VERSION 3.7 KNOWN LIMITATIONS ###################################################################### COMPATIBILITY/RECOMMENDED REQUIREMENTS ###################################################################### The following subsections provide compatibility and system requirements information: BACKWARD COMPATIBILITY WITH OLDER VERSIONS OF ARRAY MANAGER COMPATIBILITY WITH THE ASPI 4.7.X DRIVER COMPATIBILITY WITH STORAGE MANAGEMENT COMPATIBILITY WITH OTHER RAID MANAGEMENT UTILITIES OTHER COMPATIBILITY ISSUES GENERAL SYSTEM REQUIREMENTS MANAGEMENT CONSOLE REQUIREMENTS (CLIENT) MANAGED SYSTEM FOR WINDOWS REQUIREMENTS (SERVER) MANAGED SYSTEM FOR NETWARE REQUIREMENTS (SERVER) ONLINE HELP REQUIREMENTS REQUIRED DRIVER/FIRMWARE REVISIONS ====================================================================== BACKWARD COMPATIBILITY WITH OLDER VERSIONS OF ARRAY MANAGER ====================================================================== On a Windows system, Array Manager 3.1 or later can be upgraded to version 3.7. If you have a version of Array Manager that is earlier than version 3.1, you should uninstall this version and perform a fresh install of Array Manager 3.7. On a NetWare system, you need to uninstall any version of Array Manager previous to 3.7 before installing Array Manager 3.7. An Array Manager 3.7 console can connect to a version 3.1 or later managed system. However, using a version of the console earlier than 3.7 to connect to a version 3.7 managed system is not supported. Note: Array Manager 3.6 and earlier use a standalone installation process. Starting with Array Manager 3.7, Array Manager is installed using the Dell OpenManage Server Administrator installation process. The Server Administrator installation may have its own requirements regarding backward compatibility. You should review the Server Administrator install readme (readme_ins.txt) to fully understand backward compatibility and install requirements. ====================================================================== COMPATIBILITY WITH THE ASPI 4.7.X DRIVER ====================================================================== Although Array Manager can be installed on a system that has the ASPI 4.7.x driver, the Array Manager runtime dependency check disables non-RAID SCSI disk and enclosure management if the ASPI 4.7.x driver is installed. Refer to the Array Manager online help for more information about runtime dependency checking. If you have the ASPI 4.7.x driver installed on your system, you need to remove this driver and install the ASPI 4.6 driver. You can do this by downloading the ASPI 4.6 package from http://support.dell.com. The ASPI 4.6 package uninstalls the ASPI 4.7.x driver and installs the ASPI 4.6 driver. Refer to the documentation of any other applications installed on the system to see if those applications have known problems with the ASPI 4.6 driver. Note: The Adaptec aspi32.sys driver version 4.6 that is installed by Array Manager has not passed the WHQL certification tests that are recommended by Microsoft. Running Microsoft’s Driver Verifier against this driver will report problems with the driver. It is recommended that Microsoft’s Driver verifier not be run once Array Manager has been installed. ====================================================================== COMPATIBILITY WITH STORAGE MANAGEMENT ====================================================================== The Dell OpenManage Server Administrator installation process provides two RAID management utilities: * Array Manager * Storage Management (Server Administrator enhanced Storage Management Service) Installing Storage Management replaces any previous installation of the Array Manager managed system (server software) that resides on the system. The Array Manager console (client software) is not replaced. ====================================================================== COMPATIBILITY WITH OTHER RAID MANAGEMENT UTILITIES ====================================================================== As a general rule, you should use only one RAID utility to configure and manage storage. Installing Array Manager on a system that has native RAID utilities or RAID utilities provided by Dell or other vendors is an unsupported configuration. The following list is an example of RAID utilities provided by Dell or other vendors. - LinFlash - DellMgr - DellMON - LINLib - MegaMgr - MegaMON The following describes particular compatibility issues associated with the FAST and PERC console utilities. * Compatibility Issues With the Flexible Array Storage Tool (FAST): You cannot use Array Manager on a system that has the FAST RAID management utility installed. The Array Manager runtime dependency check verifies whether FAST is installed or not. See the Array Manager online help for information on the runtime dependency checking and what happens if FAST is detected. When installed, the FAST application name in the Windows Control Panel is Dell PERC2. Note that when you install the Dell OpenManage Server Agent, you may be prompted to also install FAST. FAST should not be installed since this will conflict with the Array Manager runtime. * Compatibility Issues with the PERC console: Both Array Manager and the PERC console can be installed on the same server. However, only one program at a time can be used to configure PERC 2/SC, PERC 3/SC, PERC 2/DC, PERC 3/DC, PERC 3/DCL, PERC 3/QC, PERC 4/SC, PERC 4/DC, 4/Di, 4/IM and CERC ATA100/4ch controllers. To maintain the integrity of the storage device configuration, simultaneous use of Array Manager and the PERC console is not supported. Dell strongly recommends that Array Manager and the PERC console not be used at the same time on the same server. Note that when you install the Dell OpenManage Server Agent, you may be prompted to also install the PERC console. Given the compatibility problems with the PERC console, you should consider not installing it. ====================================================================== OTHER COMPATIBILITY ISSUES ====================================================================== * Applications that query the Array Manager Management Information Base (MIB) may experience unpredictable behavior when querying a system that is managed by both Array Manager and HP OpenView. IT Assistant is an example of an application that may query the Array Manager MIB. If the query is sent to a system that is managed by both Array Manager and HP OpenView, IT Assistant may receive erroneous values (such as null strings). It is possible that rebooting the system will resolve these problems. This compatibility issue with HP OpenView does not affect the receipt of events in the Array Manager event log or SNMP trap forwarding. * Compatibility issues with the NetWare 6 QLCSFTE.CDM and DellSEP.CDM drivers. There is an incompatibility between the QLCSFTE.CDM and DellSEP.CDM drivers in NetWare 6 and the enclosure management provided by Array Manager. In NetWare 6, the hardware discovery logic detects the Qlogic chips within the server and auto installs the QLCSFTE.CDM and DellSEP.CDM drivers. These drivers interfere with the Array Manager enclosure management. To resolve this problem, the Array Manager installation process comments out the lines for loading the QLCSFTE.CDM and DellSEP.CDM drivers in the STARTUP.NCF file. You should not remove the ";(Commented out by install...)" designation within the STARTUP.NCF file or attempt to manually re-install these drivers. If you do restore the QLCSFTE.CDM and DellSEP.CDM drivers, then the enclosure management features of Array Manager will not function on NetWare 6. When you uninstall Array Manager, the QLCSFTE.CDM and DellSEP.CDM drivers are restored. If you make configuration changes on NetWare 6.5 after installing Array Manager, the HDETECT utility may reactivate the QLCSFTE.CDM or the DellSEP.CDM drivers by removing the ";(Commented out by install...)" designation within the STARTUP.NCF file. Once the QLCSFTE.CDM and DellSEP.CDM drivers are reactivated, Array Manager is disabled. The solution to this problem is to reinstall Array Manager. Examples of configuration changes that will cause this problem are installing a new RAID or NIC card or installing NWASPI.CDM. * Disabling the Array Manager Disk Management Service: If you do not want the Array Manager Disk Management service to start automatically each time you boot your machine, you can set the service to manual start only. Use the following steps to change the Array Manager Disk Management service from automatic start to manual start: 1. Select "Start"-->"Settings"-->"Control Panel"--> "Administrative Tools"-->"Services". 2. Select "Services" in the left pane. 3. Double-click "Disk Management Service" in the right pane. 4. Select the "General" tab. 5. Select "Manual" from the "Startup type" pull-down menu. 6. Click "OK." NOTICE: If the Array Manager Disk Management Service is not started, you will not receive any alerts or warnings in the event of a failure. * Compatibility Issues with the Dell OpenManage Server Agent When using Array Manager with the Dell OpenManage Server Agent 1.0 through 1.4.x, you may receive duplicate events regarding the following enclosures: Dell PowerVault 200S Dell PowerVault 201S Dell PowerVault 210S Dell PowerVault 211S For this reason, installation of Array Manager disables the Dell OpenManage Server Agent's enclosure management for versions of the Server Agent 1.0 through 1.4.x. ====================================================================== GENERAL SYSTEM REQUIREMENTS ====================================================================== The following requirements apply to any system running the Array Manager console (client) or the Array Manager managed system (server): * 64 megabytes (MB) of RAM. * Administrator access to the system. * For information on supported operating systems for the Array Manager console and managed system, see the following sections: - Management Console Requirements (Client) - Managed System for Windows Requirements (Server) - Managed System for NetWare Requirements (Server) * Transmission Control Protocol/Internet Protocol (TCP/IP) connection on the console and server when attempting remote system management. * Simple Network Management Protocol (SNMP) services are required for SNMP support. If you do not have SNMP, Array Manager will function as normal but will not provide SNMP support. Note: Dell provides configuration utilities that enable you to perform certain RAID management operations using supported controllers on platforms not currently supported by Array Manager. These utilities are available at support.dell.com. ====================================================================== MANAGEMENT CONSOLE REQUIREMENTS (CLIENT) ====================================================================== The following are minimum requirements for installing the Array Manager console. The console is the client portion of Array Manager. * 64 megabytes (MB) of RAM. * 40 MB of free hard drive space. * One of the following versions of Windows: - Microsoft Small Business Server. - Microsoft Windows(R) 2000 Server with service pack 3 or later. - Microsoft Windows 2000 Advanced Server with service pack 3 or later. - Microsoft Windows 2000 Professional with service pack 3 or later. - Microsoft Windows XP with service pack 1 or later. - Microsoft Windows Server 2003 Enterprise Server. Note: It is highly recommended that you use the most current service pack. * Administrator rights. * Transmission Control Protocol/Internet Protocol (TCP/IP) connection on the console and server when attempting remote system management. * Microsoft Management Console (MMC) Version 1.2 or later for snap-in support on Windows 2000 and Windows Server 2003. * (Optional). Novell Client for Windows version 4.9 or later if you intend to map a drive to a NetWare system and copy the Array Manager install media from the Windows system to the NetWare system. The Novell Client is also required if you wish to use the Array Manager Utilities to modify a NetWare server configuration. * (Optional). Microsoft Internet Explorer Version 4.0 or later for viewing the online help and the browser plug-in. ====================================================================== MANAGED SYSTEM FOR WINDOWS REQUIREMENTS (SERVER) ====================================================================== The following are minimum requirements for installing a managed system for Windows. * A server running one of the following versions of Windows: - Microsoft Small Business Server. - Microsoft Windows 2000 Server with service pack 3 or later - Microsoft Windows 2000 Advanced Server with service pack 3 or later - Microsoft DataCenter - Microsoft Windows Server 2003 Enterprise Server Note: It is highly recommended that you use the most current service pack. * 64 MB of RAM. * 15 MB of free hard disk space on the local drive. * Administrator access to the system. * Hardware and drivers installed for at least one Dell RAID controller. Drivers and firmware for supported controllers can be downloaded from the Dell support site at support.dell.com. * Fibre Channel Host Bus Adapters and associated device drivers are needed to manage the Dell PowerVault 660F Fibre Channel RAID array in either a direct-attach or SAN environment. * (Optional) TCP/IP installation if this system will be managed over a network. * (Optional). Simple Network Management Protocol (SNMP) for SNMP trap forwarding by Array Manager. The SNMP service should be installed prior to installing Array Manager. * (Optional) On NetWare, Array Manager requires that the Dell OpenManage Server Agent (OMSA) 4.0.0 or later be installed on the managed system to provide thermal shutdown (when an enclosure becomes too hot or cold) for the Dell PowerVault 20xS, 21xS, and 22xS SCSI enclosures. If OMSA is not installed, Array Manager can provide other features of enclosure management, but not thermal shutdown without the risk of data loss. Note: The managed system’s RAID controllers must be attached to storage in order to run Array Manager. ====================================================================== MANAGED SYSTEM FOR NETWARE REQUIREMENTS (SERVER) ====================================================================== The following are minimum requirements for installing a managed system for NetWare. * 64 megabytes of RAM. * 15 megabytes of free hard disk space. * Administrator or supervisor access to the system. * One of the following versions of Novell NetWare: - Novell NetWare version 5.1 or later with Support Pack 7 or later. - Novell NetWare version 6.5 or later with Support Pack 2 or later is supported in a SCSI environment. (See the Dell PowerVault Systems Storage Area Network (SAN) documentation for information on SAN support for NetWare.) * Hardware and drivers installed for at least one Dell RAID controller. Drivers and firmware for supported controllers can be downloaded from the Dell support site at support.dell.com. * The pedge.ham and megammio.nlm drivers should be installed in the NWSERVER/drivers or NWSERVER directory before installing Array Manager. * Fibre Channel Host Bus Adapters and associated device drivers are needed to manage the Dell PowerVault 660F Fibre Channel RAID Array in either a direct-attach or SAN environment. See the Dell PowerVault Systems Storage Area Network (SAN) documentation for information on supported NetWare configurations. * Transmission Control Protocol/Internet Protocol (TCP/IP) required for connection to the management console. * Long file name support. * (Optional). Novell Client for Windows version 4.9 or later installed on a remote Windows system if you intend to copy the Array Manager install media from the Windows system to the NetWare system by mapping a drive. * (Optional). Simple Network Management Protocol (SNMP) for SNMP trap forwarding by Array Manager. * (Optional) On NetWare, Array Manager requires that the Dell OpenManage Server Agent (OMSA) 4.0.0 or later be installed on the managed system to provide thermal shutdown (when an enclosure becomes too hot or cold) for the Dell PowerVault 20xS, 21xS, and 22xS SCSI enclosures. If OMSA is not installed, Array Manager can provide other features of enclosure management, but not thermal shutdown without the risk of data loss. Note: The managed system’s RAID controllers must be attached to storage in order to run Array Manager. Note: When installing on NetWare, the Array Manager installation may not recognize the pedge.ham version 2.06 driver on a PERC 2/SC or PERC 2/DC controller. If the Array Manager installation displays an error message regarding the 2.06 driver, update the driver to pedge3.ham version 3.13. ====================================================================== ONLINE HELP REQUIREMENTS ====================================================================== Internet Explorer version 4.0 or later is required for launching and viewing the online help from the Array Manager console. In addition to the online help, the Array Manager installation directory includes documentation in html and PDF format. ====================================================================== REQUIRED DRIVER/FIRMWARE REVISIONS ====================================================================== *** PERC RAID + non-RAID SCSI Controller Cards LSI 1020 and LSI 1030 *** These include PERC 2/SC, 2/DC, 3/SC, 3/DC, 3/DCL, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, LSI 1020, and LSI 1030. The firmware and drivers listed in the following table refer to the minimum supported version. Later versions of the firmware and drivers are also supported. Refer to http://support.dell.com for the most recent driver and firmware requirements. Controller Firmware Windows 2000 Windows NetWare Driver Server Driver 2003 Driver PERC 2/SC 3.13 2.68 6.35.2.32 NW 5.1 (Native) NW 6.5 (Native) Note: NetWare is not supported on PowerEdge x300 systems with a PERC 2/SC. PERC 2/SC on a 3.13 2.68 6.35.2.32 NW 5.1 (Native) PowerEdge 8450 NW 6.5 (Native) PERC 2/DC on a 1.06 2.68 6.35.2.32 NW 5.1 (2.06) PowerEdge x300 NW 6.5 (Not Applicable) PERC 2/DC on a 1.06 2.68 6.35.2.32 NW 5.1 (Native) PowerEdge x400 NW 6.5 (Native) PERC 3/SC 197O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 198Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 3/DC 197O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 198Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 3/DCL 197O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 198Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 3/QC 197O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 198Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4/SC 350O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 351Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4/DC 350O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 351Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4e/DC 513T 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 521Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4e/Si 513O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 521Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4e/Di 513O 5.46 6.41.2.32 NW 5.1 (7.02c) (Required) (Required) (Required) NW 6.5 (7.02c) 521Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4/Di on a 2.50O 5.46 6.41.2.32 NW 5.1 (7.02c) PowerEdge 2600 (Required) (Required) (Required) NW 6.5 (7.02c) 251Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4/Di on a 413O 5.46 6.41.2.32 NW 5.1 (7.02c) PowerEdge 1750 (Required) (Required) (Required) NW 6.5 (7.02c) 421Q 5.48 6.46.2.32 (Recommended) (Recommended) (Recommended) PERC 4/IM on a 1.00.12.00 1.08.06 1.08.18 NW 5.1 (Not Applicable) PowerEdge (1.00.0C.00 Hex) (Required/ NW 6.5 (Not Applicable) 1655MC Native) 1.08.06 (Recommended) CERC 6.62 5.46 6.41.2.32 NW 5.1 (7.01v) ATA 100/4CH NW 6.5 (7.01v) LSI 1020 on a 1.03.04.00 1.08.19 1.08.18 NW 5.1 (Not Applicable) PowerEdge (Required) (Required) (Required/ NW 6.5 (3.03) 1600SC 1.03.23 1.09.11 Native) (Recommended) (Recommended) 1.09.11 (Recommended) LSI 1030 on a 1.01.61.00 1.08.19 1.08.18 NW 5.1 (Not Applicable) PowerEdge (Required) (Required) (Native) NW 6.5 (3.03) 2600 1.03.23 1.09.11 (Recommended) (Recommended) LSI 1030 on a 1.01.61.00 1.08.19 1.08.18 NW 5.1 (Not Applicable) PowerEdge (Required) (Required) (Native) NW 6.5 (3.03) 1750 1.03.23 1.09.11 (Recommended) (Recommended) Note: When installing on NetWare, the Array Manager installation may display an abbreviated name for the required NetWare driver. Only the numerical portion of the driver name may be displayed. The letter portion of the driver name (if any) may not be displayed. For example, if the driver name is "123A", then only the "123" portion of the name may be displayed. Note: When installing on NetWare, the Array Manager installation may not recognize the pedge.ham version 2.06 driver on a PERC 2/SC or PERC 2/DC controller. If the Array Manager installation displays an error message regarding the 2.06 driver, update the driver to pedge3.ham version 3.13. Note: PERC is not supported by Array Manager 3.7 on any operating system. PERC is supported by Array Manager version 2.0 on NetWare. *** PERC 2 RAID Controller Cards + RAID On Motherboard (ROMB) *** These include PERC 2, PERC 2/Si, PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s. The firmware and drivers listed in the following table refer to the minimum supported version. Later versions of the firmware and drivers are also supported. Refer to http://support.dell.com for the most recent driver and firmware requirements. Note: Versions of the PERC 2 controller prior to 2.8 are not supported. The minimum requirement of 2.8 applies to all of the PERC 2, PERC 2/Si, PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers. Note: Array Manager requires that the system be rebooted before Array Manager can properly determine whether the system meets the firmware and driver requirements for the PERC 2, PERC 2/Si, PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers. For this reason, it is possible to complete an initial installation of Array Manager without being notified whether your system meets the firmware and driver requirements. If you install Array Manager and reboot the system, you can view the correct firmware and driver requirements through the Array Manager Utilities. If you reinstall or upgrade Array Manager, the install process will notify you of the firmware and driver requirements. Controller Firmware Windows 2000 Windows NetWare Driver Server Driver 2003 Driver PERC 2 (2/QC) 2.8.0.6089 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) NW 6.5 (6075) PERC 2/Si 2.8.0.6089 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) NW 6.5 (6075) PERC 3/Si 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 1650 NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 2500 NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 2550 NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 2650 NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 4400 NW 6.5 (6075) PERC 3/Di on a 2.8.0.6092 2.8.0.6085* 2.8.0.6085* NW 5.1 (6075) PowerEdge 4600 NW 6.5 (6075) CERC 2.8.0.7403 2.8.0.7010 2.8.0.7010 NW 5.1 (7031) SATA1.5/6ch (Required) (Required) (Required) NW 6.5 (7031) 4.1.0.7406 4.1.0.7010 4.1.0.7010 (Recommended) (Recommended) (Recommended) CERC Not 6.00.050 6.00.050 NW 5.1 (6.00.053)** SATA1.5/2s Applicable NW 6.5 (6.00.053)** Note: * The Array Manager install requires driver version 2.8.0.6076 or higher. The Array Manager Utilities display this driver as 2.8.0.6076. The Device Manager for Windows 2000 and Windows Server 2003, however, displays driver version 2.8.0.6076 as 2.8.0.6085. Note: **The CERC SATA1.5/2s controller requires the aarichd.ham driver on a NetWare system. *** PowerVault 660F *** The firmware and drivers listed in the following table refer to the minimum supported version. Later versions of the firmware and drivers are also supported. Refer to http://support.dell.com for the most recent driver and firmware requirements. SAN 4.06: Controller HBA BIOS Windows NT or 2000 Driver PowerVault 660F QL2100 1.35 QL2100.SYS 7.05.08 PowerVault 660F QL2200 1.45 QL2200.SYS 7.05.08 SAN 5.01: Controller HBA BIOS Windows NT or 2000 Driver PowerVault 660F QL2200 1.76 QL2200.SYS 8.00.09.24 SAN 4.06 and 5.01 support Windows NT and Windows 2000. For the latest information on SAN support for NetWare, see the Dell PowerVault Systems Storage Area Network (SAN) documentation. Note: The background initialization feature on PowerVault 660F controllers is only available when using PowerVault 660F controller firmware 7.7 or later. *** Ultra SCSI Controller Cards *** These include Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, Ultra320 SCSI Support for the Ultra SCSI controller cards is provided in the BIOS. Array Manager Utilities does not display this information. ###################################################################### WARNINGS ###################################################################### * The Windows NT Disk Administrator should never be used while Array Manager is running, particularly if there are tasks running at the same time on the controller. DATA LOSS CAN OCCUR IF BOTH APPLICATIONS ARE RUNNING SIMULTANEOUSLY. * PowerEdge servers earlier than x300 are not supported. * The (clustered) PERC 3/DCs and the PowerVault 660F fibre channel controller are the only clustered controllers supported by this software. * In a clustered environment, it is recommended that all virtual disks use the entire capacity of their member array disks. In a situation where a virtual disk only uses a portion of an array disk, a failed array disk may not rebuild properly. * When importing foreign disks that contain a dynamic volume created previously by Array Manager, YOU MUST IMPORT ALL OF THE DISKS THAT MAKE UP THE VOLUME AT THE SAME TIME. Failure to do so will result in DATA LOSS. * NEVER remove a hard drive from its enclosure while the drive's individual activity light emitting diode (LED) is blinking. This action is likely to cause SEVERE DATA LOSS. * PERCs have a feature called "PowerFail" that uses up to two assigned hot spares during reconfiguration of a virtual disk (Transform Type, Add Member). While this reconstruction is in progress, NEVER remove the hot spare array disks that are part of the reconstruction. * As a general rule, you should be logged on to the local computer system with Administrator access rights when launching the Array Manager console. * You should uninstall Array Manager before upgrading the Windows operating system. After upgrading Windows, reinstall Array Manager using the Array Manager install media or by downloading Array Manager from the Dell Website at support.dell.com. If you notice changes in the drive letters after uninstalling Array Manager and then upgrading Windows, refer to the Dell Knowledge Base item 832097 for information on resolving this situation. ###################################################################### WHAT IS NEW IN THIS RELEASE? ###################################################################### The following features are new in Array Manager Version 3.7: * In this release, Array Manager is installed using the Dell OpenManage Server Administrator installation process. The Server Administrator installation uses features native to the operating system. * In previous releases of Array Manager, the Array Manager installation included dependency checking to verify that the system has a valid configuration before installing Array Manager. Some of these dependency checks are now performed at Array Manager runtime and not during installation. See the Array Manager online help for more information. * After installation, support for the PV660F Storage System is disabled by default. You can enable support for the PV660F Storage System using the Array Manager Utilties after installation. See the "Enabling and Disabling the PV660F Fibre Channel RAID and Enclosure Management" section in the installation chapter of the Array Manager online help for more information. ###################################################################### WHAT IS FIXED IN THIS RELEASE? ###################################################################### The following issues have been fixed in Array Manager 3.7: * Array Manager installation process does not display the status of required firmware for a PERC 3/QC controller on Windows Server 2003 (64 bit). Solution: The installation process displays a warning if the driver and firmware prerequisites are not met. * Array Manager may allow virtual disk reconfigurations when sufficient disk space is not available. Solution: When reconfiguring a virtual disk, Array Manager only enables you to select valid RAID levels and array disks to ensure a successful reconfiguration. * Export Log File command does not work on NetWare with the CERC ATA 100/4ch controller. Solution: Export Log File is no longer supported when using a CERC ATA 100/4ch controller on NetWare. ###################################################################### INSTALLING ARRAY MANAGER VERSION 3.7 ###################################################################### The following subsections describe Array Manager installation: INSTALLING ON WINDOWS INSTALLING ON NETWARE REMOTE INSTALLATION ON WINDOWS SERVER 2003 ====================================================================== INSTALLING ON WINDOWS ====================================================================== The Setup program takes you through the process of installing the Array Manager software. Before proceeding, you should exit all Microsoft Windows programs including the Microsoft Management Console (MMC). You must be logged on with Administrator rights to install Array Manager. Note: The installation cannot be completed unless you are logged on with Administrator rights. If you attempt to install without Administrator rights, the install will fail and display an error message referencing "iKernel.exe". Installing from the Dell PowerEdge Installation and Server Management CD: 1. Insert the CD. Setup should begin automatically. If not, start setup by double-clicking on the Setup icon located in the srvadmin/windows directory. 2. Follow the instructions shown in the Setup wizard. You may need to use Custom Setup to install Array Manager. 3. Reboot the system when finished. NOTE: When installing the managed system component on a Windows 2000 system, the Windows 2000 Plug and Play Manager will activate after the reboot, indicating that it has discovered new hardware. You may be required to perform a second reboot if volumes are present on your system. Otherwise, allow Plug and Play to register the new driver. (This occurs automatically.) Installing from the Dell PowerEdge Management Consoles CD: If you only wish to install the Array Manager console, use the following procedure: 1. Insert the CD. Setup should begin automatically. If not, start setup by double-clicking on the Setup icon located in the windows directory. 2. Follow the instructions shown in the Setup wizard. You may need to use Custom Setup to install Array Manager. 3. Reboot the system when finished. ====================================================================== INSTALLING ON NETWARE ====================================================================== You can install the Array Manager managed system on a NetWare server. You can then connect to the NetWare server from the Array Manager console. Use the following steps to install the Array Manager managed system on the NetWare server using the Dell PowerEdge Installation and Server Management CD: 1) If a version of Array Manager previous to 3.7 is already installed on the NetWare system, then uninstall that version before installing the current version of Array Manager. 2) Insert the installation CD into the NetWare server’s CDROM drive. 3) Mount the installation CD as a NetWare volume. 4) Locate the AMINST.NLM and AMINST.IPS files on the Array Manager installation CD. The AMINST.NLM and AMINST.IPS files are located in the following directory: :\srvadmin\netware\ArrayMgr 5) Start the NetWare configuration utility by entering the following from the NetWare system console: nwconfig 6) Select Product Options and then Install product not listed. 7) Specify the full path to the directory containing the AMINST.NLM and AMINST.IPS files on the Array Manager installation CD. NetWare completes the installation for you. Note: Installing Array Manager disables the NetWare QLCSFTE.CDM and DellSEP.CDM drivers. You should not attempt to manually install these drivers. For more information, see the "OTHER COMPATIBILITY ISSUES" section of this readme file. ====================================================================== REMOTE INSTALLATION ON WINDOWS SERVER 2003 ====================================================================== Array Manager enables you to perform an unattended or silent installation on a remote Windows machine. When performing an unattended installation, you run an install script that contains the steps for the installation. Array Manager provides different install scripts that contain different installation scenarios. The script for installing on Windows Server 2003 is named typw2k3.iss. When installing on Windows Server 2003, the typw2k3.iss script should be used in place of the Typical.iss script described in the Array Manager online help. For more information on unattended installation, refer to the "Unattended (Silent) Installation" section of the "Installation and Upgrades" chapter of the online help. ###################################################################### KNOWN LIMITATIONS ###################################################################### The following sections describe known problems associated with Array Manager or the supported controllers. Dell is in the process of resolving these problems. GENERAL PROBLEMS PROBLEMS ASSOCIATED WITH THE PERC AND CERC CONTROLLERS PROBLEMS ASSOCIATED WITH THE POWERVAULT 660F AND 650F CONTROLLERS ====================================================================== GENERAL PROBLEMS ====================================================================== * Temperature probes may display Unknown state after upgrading the EMM firmware. (146666) Problem: When upgrading the enclosure management module (EMM) firmware on a PowerVault 22xS enclosure, the enclosure temperature probes may display an Unknown state. Solution: Reboot the server and the enclosure to restore the correct values for the temperature probe state. * NetWare system may abend or Array Manager may hang when creating virtual disks in rapid succession. (143358) Problem: When using a PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, or CERC SATA1.5/2s controller on a NetWare system, the NetWare system may abend or Array Manager may hang if you complete the Create Virtual Disk wizard and then immediately attempt to create another virtual disk. Solution: You can avoid this problem by waiting a full minute after creating a virtual disk before creating another virtual disk. If the NetWare system abends, reboot the system. If Array Manager hangs, restart Array Manager. If restarting Array Manager does not resolve the problem, then reboot the system. * After a disk failure, Array Manager may display a replacement disk that is too small. (142810) Problem: Under some conditions, Array Manager may display a disk that is too small to function as part of an array or disk group being used by one or more virtual disks. Even though the disk is too small, Array Manager may display the disk as though it is a functional member of the array or disk group. This situation may occur after a disk failure if the replacement disk is smaller than the failed disk. Solution: When replacing a failed disk, always use a disk that is the same size or larger than the failed disk. * Display of storage information by Server Administrator may appear garbled. (139118) Problem: If you are using Server Administrator with an Array Manager installation, Array Manager sends storage information to Server Administrator. This storage information is displayed on the Server Administrator user interface. In languages that use a multibyte character set, the display of storage information such as volume labels by Server Administrator may be garbled. Server Administrator's inability to display multibyte characters only occurs on a Windows 2000 system with Array Manager and disk and volume management installed. The Array Manager console displays the multibyte characters correctly. Solution: Use the Array Manager console which displays multibyte characters correctly. * Maximum recharge count for batteries is not displayed. (138804) Problem: Some controllers have rechargeable batteries. These batteries have a fixed number of times that they can be recharged (maximum recharge count) before they are subject to a failure. Array Manager displays the number of times that the battery has been recharged (charge count). Array Manager does not, however, display the maximum recharge count for the battery. When the maximum recharge count is reached, Array Manager does not generate an event message warning that the battery is subject to failure. Solution: Although Array Manager does not display the maximum recharge count or generate a warning event, Array Manager does indicate when a controller battery should be replaced. To view this information, right-click the Controller object in the tree view and select Properties from the pop-up menu. If the battery's maximum recharge count has been reached, the Battery Status field displays "Needs Replacement." * Attempts to reconfigure a virtual disk to a size greater than 1024GB display an error message stating the reconfiguration cannot complete. (134898) Problem: All firmware versions for the PERC 2, 2/Si, 3/Si, and 3/Di, controllers have a limitation that prevents virtual disks on these controllers from being reconfigured to a size greater than 1024GB. Array Manager is aware of this firmware limitation. For this reason, Array Manager displays the following message if you attempt to reconfigure a virtual disk to a size greater than 1024GB on these controllers: "Cannot Reconfigure Virtual Disk" Solution: Reconfigure the virtual disk to a size smaller than 1024GB. (If the virtual disk is already 1024GB or larger, it cannot be reconfigured to a smaller size.) Future firmware updates may resolve this limitation. * Drive may continue to receive SMART alerts even after being replaced. Problem: If you replace a drive in slot 8 or greater that is receiving SMART alerts, the new drive may continue to receive SMART alerts and generate events. Solution: Reboot the system. * Detaching the enclosure cable during a rebuild causes the controller to enter an inoperable state. Problem: If the cable to the enclosure becomes detached while a rebuild is in progress, the controller enters an inoperable state and reports the "controller is busy" status. Solution: The best solution to this problem is to avoid detaching the enclosure cable during a rebuild. If the cable does become detached, however, and the controller enters an inoperable state, reboot the system to resolve this problem. * Custom Mode of the Extend Volume wizard displays incorrect disk usage. Problem: When extending a volume using the Custom Mode of the Extend volume wizard, the amount of space to be used on each disk that is displayed by the wizard does not match the actual disk usage once the volume is extended. Solution: Dell is working to resolve this problem. * Enabling the PowerVault 660 provider when the PowerVault 660 controller is not present may abend a NetWare 6.5 system. Problem: If you enable the PowerVault 660 provider on a NetWare 6.5 system when the PowerVault 660 controller is not present and then attempt to uninstall Array Manager, the NetWare 6.5 system abends. In this situation, the system may generate the following error messages: 'Abend on P00:Page Fault Processor Exception (Error code 00000000. Running Process: VXSVC_ _P 6 Process' 'Abend on P00: Invalid object handle passed to routine kSemaphoreFree. Running Process: NLSLRUP Register Process' Solution: Dell is working to resolve this problem. * Remote connection fails on servers with multiple NIC teams. Problem: Certain technologies enable you to group multiple NetWork Interface Cards (NICs) into groups known as "teams." Array Manager may not allow you to connect remotely to a server that has multiple NIC teams. Solution: Dell is working to resolve this problem. ====================================================================== PROBLEMS ASSOCIATED WITH THE PERC AND CERC CONTROLLERS ====================================================================== * Deleting a virtual disk in the BIOS causes incorrect display of virtual disks in the Array Manager tree view. Problem: If you delete a virtual disk in the BIOS on a PERC 3/SC, 3/DCL, 3/DC, 3/QC controller, Array Manager may not properly update the display of virtual disks in the Array Manager tree view. Specifically, the numbering format for virtual disks in the tree view may not correspond to the numbering format used in the BIOS. Solution: Dell is working to resolve this problem. ====================================================================== PROBLEMS ASSOCIATED WITH THE POWERVAULT 660F AND 650F CONTROLLERS ====================================================================== * Event message for Add Virtual Disk on a PV660F is not displayed correctly Problem: When performing an Add Virtual Disk operation, the Array Manager event log displays event messages indicating that an Expand Capacity operation has started and completed instead of an Add Virtual Disk operation. Solution: Be aware that event messages referring to an Expand Capacity operation may in fact indicate an Add Virtual Disk operation. * Cannot detect when connection is lost to a PowerVault 660F array. Problem: When the connection is lost to both PowerVault 660F controllers in an array, Array Manager doesn't give any indication that it cannot communicate with the Array. Solution: To determine if Array Manager lost communication with an array, perform a PV660F Subsystem rescan. If communication is lost, the PowerVault 660F array will be removed from the console. ###################################################################### Information in this document is subject to change without notice. (c) 2005 Dell Inc. (c) 2005 VERITAS Software Corporation. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc. and VERITAS Software Corporation is strictly forbidden. Portions copyright (c) 1998 Chris Maunder. Some cryptographic code in this product is derived from the SSLeay library, copyright (c) 1995-97 by Eric Young (eay@cryptsoft.com). All rights reserved. Trademarks used in this text: "Dell", "Dell OpenManage", the DELL logo, "PowerEdge", and "PowerVault" are trademarks of Dell Inc.; "Microsoft", "Windows", "Windows NT", and "Windows 2000" are registered trademarks of Microsoft Corporation; "Novell" and "NetWare" are registered trademarks of Novell, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. and VERITAS Software Corporation disclaim any proprietary interest in trademarks and trade names other than their own. February, 2005 DELL OPENMANAGE(TM) Array Manager, VERSION 3.7 README