<!--#include virtual="/NRConfig/CacheConfig/CNCASPPageUI_CacheConfig.inc"-->
<% 
'*****************************************************************************
' Copyright (C) 2001 Microsoft Corporation. All rights reserved.
'
' File:  SCA/CNCASPPageManager_CacheConfig.inc
' Author: Microsoft Corporation
'
' Purpose:
'   Define functions for display and render Cache tab  
'
'Public Methods and Properties Exposed:
'	- Sub InitManager()
'	Property DiskCacheLocation [ReadOnly, String]
'	Property IsMaxCacheSizeLocal [ReadOnly, Boolean]	
'	Property IsNodeCacheSizeLocal [ReadOnly, Boolean]
'	Property MaxCacheSize [ReadOnly, Number]
'   Property NodeCacheSize [ReadOnly, Number]
'	Property ResServerIndex [ReadOnly, Number]
'	Property DriveCollection [ReadOnly, Collection]
'	Property Error [ReadOnly, String]
'	Property ErrorDetail [ReadOnly, String]
'	Property GlobalMaxCacheSize [ReadOnly, Number]
'	Property GlobalNodeCacheSize [ReadOnly, Number]
'	Property IsSupportedBrowser [ReadOnly, Boolean]
'	Property IsDiskCacheLocationRight [ReadOnly, Boolean]
'	Property IsSSLRunning [Readonly, Boolean] 
'	Property IsLocalHost [Readonly, Boolean] 
'	Property SecurityAlertURL [Readonly, String]
'	
'*****************************************************************************

'--Define constants

'Define a class to create CInitManager class
Class CNCASPPageManager_CacheConfig
	
	'Public property
	Public ResServerIndex
	Public DiskCacheLocation
	Public IsMaxCacheSizeLocal	
	Public IsNodeCacheSizeLocal
	Public GlobalMaxCacheSize
	Public GlobalNodeCacheSize
	Public MaxCacheSize
    Public NodeCacheSize
    Public DriveCollection
    Public IsDiskCacheLocationRight
	Public Error
	Public ErrorDetail
	Public IsSupportedBrowser
	Private m_bIsSSLRunning
	Private m_bIsLocalHost
	Private m_strSecurityAlertURL
	
	'Define private variable
	Private m_pSCAPI
	Private pFileSystem
	
	'---- [Private] Standard Class_Initialize
	Private Sub Class_Initialize()
		' -- init all member with default values
		
		ResServerIndex = -1
		DiskCacheLocation = "None"
		IsMaxCacheSizeLocal = False	
		IsNodeCacheSizeLocal = False
		MaxCacheSize = 0
		NodeCacheSize = 0
		GlobalMaxCacheSize = 0
		GlobalNodeCacheSize = 0
    	IsDiskCacheLocationRight = False
		Error = "OK"
		ErrorDetail = ""
		Set DriveCollection = Nothing

		m_bIsLocalHost = False
		m_bIsSSLRunning = False
		
		Call ChkIsLocalHostConnection()
		Call SetupSSLRunningFlag()
		
		m_strSecurityAlertURL = "\NRConfig\SecurityAlert\SecurityAlert.asp?" & "ResServerIndex=" & Request.QueryString("ResServerIndex")
		
		'-- Create an instance of ServerConfiguration API
		SET m_pSCAPI = server.createobject("ServerConfigurationAPI.NRSCAPI")
		
		'-- Inititalize this API
		m_pSCAPI.Initialize ( )
		
	End Sub
	
	'*************************************************
	'Purpose: Response for all init asp page process for Cache tab and Dlg
	'         
	'Input:	  None
	'
	'Output:  Get values from API and set up properties 
   	'************************************************* 
	Public Sub InitManager()

		'--Check browser version and java script enable
		IsSupportedBrowser = VerifyIsSupportedBrowser
	
		
		'--Get Resolution index
		ResServerIndex = Request.QueryString(IDS_QUERYSTRING_RESOLUTION_SERVER_INDEX)
		
		' -- Check ResServerIndex exist or not  
		ResServerIndexExist(ResServerIndex)
		
		'-- No Resolution Entry Point not run this code
		If ResServerIndex > ID_NO_RESOLUTION_ENTEY_POINT Then
		
			' --If can get form elements, then update otherwise get data from API
			If GetFormElements Then 

				'-- Validate disk cache location
				If IsDisKCacheFolderExist Then
					'-- Update data to API after user submit form
					Call UpdateDataToAPI
					
					If Err.number = 0 Then
						'--If no error, Close popup window and back to main ASP Page
						Call CloseWindowAndRedirectToMainASP	
					End If
				Else					
						'-- Create driver collection for validate Max Cache Size			
						Call CreateDrivesCollection()					
				End If
			Else	
				'--Get API data for both tab control renderer and General config UI
				Call GetAPIDataForUI
			End If
		
	 	Else
			Error = IDS_UI_WARNING_NOENTRYPOINTS_ISWRONG	
		End If	
	 End Sub
	   	
	' ---- [Public] Whether or not this is loaded locally
	Property Get IsLocalHost()
		IsLocalHost = m_bIsLocalHost
	End Property 
	
	' ---- [Public] Whether or not this is loaded via SSL
	Property Get IsSSLRunning()
		IsSSLRunning = m_bIsSSLRunning
	End Property 
	
	' ---- [Public] URL to security alert page
	Property Get SecurityAlertURL()
		SecurityAlertURL = m_strSecurityAlertURL
	End Property 
	
	'-- [Private] Validate disk cache location 
	Private Function IsDisKCacheFolderExist() 

		' -- Create an instance from file system object
		Call CreateFileSytemObject

		'-- Set value
		If Not (pFileSystem.FolderExists(DiskCacheLocation)) Then

			IsDiskCacheLocationRight = True
			IsDisKCacheFolderExist = False
			
		Else
			IsDisKCacheFolderExist = True
		End If

		'-- Clear object
		Set pFileSystem = Nothing
			

	End Function
	   	
	'-- [Private] Update Cache data to API 
	Private Sub UpdateDataToAPI

		On Error Resume next

		' -- Set new script time out 
		Dim ScriptTimeOut
   		Server.ScriptTimeOut = 100000
		
		Dim pCache
		Set pCache = m_pSCAPI.LocalSettings(ResServerIndex).Cache	
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_CACHE_OBJECT
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		'-- Set disk cache location
		if StrComp(pCache.CacheFolder.ParentCacheFolder, DiskCacheLocation, 1) <> 0 then 
			pCache.CacheFolder.ParentCacheFolder = DiskCacheLocation  
		end if
				
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_DISK_CACHE_FOLDER_LOCATION
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		Dim pGlobal
		Set pGlobal = pCache.GlobalDefault
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_GLOBAL_DEFAULT_OBJECT 
			ErrorDetail = Err.Description
			Exit Sub
		End If
		'--Error Check
		
		
		Dim pLocal
		Set pLocal = pCache.Local
		
		If Err.Number <> 0 Then
					Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_LOCAL_OBJECT
					ErrorDetail = Err.Description
					Exit Sub
		End If

		'-- Set Max Cache size
		If IsMaxCacheSizeLocal Then
			Call pLocal.SetMaxFileCacheSize(MaxCacheSize)
			
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_MAX_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If
				
		Else
			Call pLocal.RemoveMaxFileCacheSize()
			
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_MAX_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If
			
			Call pGlobal.SetMaxFileCacheSize(MaxCacheSize)				
		
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_MAX_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If
		End If

				
		'-- Set Node Cache Size

		If IsNodeCacheSizeLocal Then
			Call pLocal.SetNodeCacheSize(NodeCacheSize)
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_NODE_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If	
		Else
			Call pLocal.RemoveNodeCacheSize()
			
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_NODE_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If
			Call pGlobal.SetNodeCacheSize(NodeCacheSize)	
			'--Error Check
			If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_UPDATE_NODE_CACHE
				ErrorDetail = Err.Description
				Exit Sub
			End If
			
		End If
		
		'--Back to default for script time and bufer
		Server.ScriptTimeOut = ScriptTimeOut

		'-- Clear object
		Set pCache = Nothing
		Set pLocal = Nothing
		Set pGlobal = Nothing
		Set m_pSCAPI = Nothing
	
	End Sub
	   	
	'-- [Private] Close popup window and redirect to main asp page after update data to API
	Private Sub CloseWindowAndRedirectToMainASP()


		'-- Render a java script to close popup window and redirect to main asp
		call Response.Write ("<script language='JavaScript'  type='text/javascript'>" & vbCrLf)
		Call Response.Write ("window.opener.location = '../" & IDS_MAIN_CONFIGASPPAGE & "?" & _
												 IDS_QUERYSTRING_RESOLUTION_SERVER_INDEX &	_
												"=" & CLng(ResServerIndex) & "&" & _
												IDS_QUERYSTRING_CURRENT_TAB_INDEX & "=" & _
												IDS_CONFIG_CACHE_QUERYSTRING  & _
												"&" & IDS_QUERYSTRING_SKIPSSL_WARNING & "=true" & _
												"&" & IDS_TIME_STAMP & "=" & CDbl(CDate(now)) & "';"  & vbCrLf)
		Call Response.Write ("IsWindowOpenBefore = false;" & vbCrLf)
		Call Response.Write ("window.close();" & vbCrLf)
		call Response.Write ("</script>" & vbCrLf)

	End Sub
	   	
	'-- [Private] Validate form submit or not to decide validate or not
	Private Function GetFormElements()

		'  -- Get form elements
		IsMaxCacheSizeLocal = Request.Form(DIS_FORM_ELEMENTS_CACHE_RADIO_LOCALMAXCACHE)
		If IsMaxCacheSizeLocal Then
			MaxCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXT_LOCALMAXCACHE) )
		Else
			MaxCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXT_GLOBALMAXCACHE) )
		End If
		GlobalMaxCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXT_GLOBALMAXCACHE) )

		IsNodeCacheSizeLocal = CBool( Request.Form(DIS_FORM_ELEMENTS_CACHE_RADIO_LOCALNODECACHE) )
		If IsNodeCacheSizeLocal Then
			NodeCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXTBOX_LOCALNODECACHE ) )
		Else
			NodeCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXTBOX_GLOBALNODECACHE) )
		End If
		GlobalNodeCacheSize = CLng( Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXTBOX_GLOBALNODECACHE) )
				
		DiskCacheLocation = Request.Form(DIS_FORM_ELEMENTS_CACHE_TEXTBIX_DISKCACHELOCATION )

		' -- Return value
		GetFormElements = CBool(Request.Form(DIS_FORM_ELEMENTS_GENERAL_FORMSUBMIT))
		
		
	End Function
		
	'--[Private] Get API data for UI
	Private Sub GetAPIDataForUI()

		On Error Resume next

		'-- Get Parent Cache Folder
		Dim pCache
		Set pCache = m_pSCAPI.LocalSettings(ResServerIndex).Cache
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_CACHE_OBJECT
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		
		DiskCacheLocation = pCache.CacheFolder.ParentCacheFolder


		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_CACHE_FLODER
			ErrorDetail = Err.Description
			Exit Sub
		End If

		
		'--Identify local or global value and get value
		Dim pLocal
		Set pLocal = m_pSCAPI.LocalSettings(ResServerIndex).Cache.Local	
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_LOCAL_OBJECT
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		
		Dim pGlobal
		Set pGlobal = m_pSCAPI.LocalSettings(ResServerIndex).Cache.GlobalDefault
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_GLOBAL_DEFAULT_OBJECT 
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		'-- Get max cache size 
		If pLocal.GetMaxFileCacheSize.IsConfigured Then 
			IsMaxCacheSizeLocal = True
			MaxCacheSize = pLocal.GetMaxFileCacheSize.Value

		Else 
			MaxCacheSize = pGlobal.GetMaxFileCacheSize.Value
		End If
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_MAX_CACHE
			ErrorDetail = Err.Description
			Exit Sub
		End If

		
		
		' -- Get global default value
		GlobalMaxCacheSize = pGlobal.GetMaxFileCacheSize.Value
			
		' -- Error Check
		If Err.Number <> 0 Then
				Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_MAX_CACHE
				ErrorDetail = Err.Description
				Exit Sub
		End If
				
		'-- Get node cache size
		If pLocal.GetNodeCacheSize.IsConfigured Then 
			IsNodeCacheSizeLocal = True
			NodeCacheSize = pLocal.GetNodeCacheSize.Value

		Else 

			NodeCacheSize = pGlobal.GetNodeCacheSize.Value

		End If
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_NODE_CACHE
			ErrorDetail = Err.Description
			Exit Sub
		End If

		

		' -- Get global default value
		GlobalNodeCacheSize = pGlobal.GetNodeCacheSize.Value
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_NODE_CACHE
			ErrorDetail = Err.Description
			Exit Sub
		End If
		
		
		' -- Create drivers collection for validating Max Cache Size
		Call CreateDrivesCollection()
		
		'--Error Check
		If Err.Number <> 0 Then
			Error = IDS_UNEXPEXTED_ERROR & " " & IDS_UI_ERROR_GET_FILE_SYSTEM_OBJECT 
			ErrorDetail = Err.Description
			Exit Sub
		End If
	
		
		'-- clear object

		Set pLocal = Nothing
		Set pGlobal = Nothing
		Set pCache = Nothing
		
		
	End Sub
	
	' -- [Private] Clear up ojbect referece to this class
	Private Sub Class_Finalize
		
		Set m_pSCAPI = Nothing

	End Sub

	' -- [Private] Create an instance of server drive collection for validate max cache size
	Private Sub CreateDrivesCollection()

		'-- Create file system object 
		Call CreateFileSytemObject
		
		Set DriveCollection = pFileSystem.Drives

		'-- Clear object
		Set pFileSystem = Nothing	

	End Sub
    
    ' -- [Private] Create file system object
    Private Sub CreateFileSytemObject()
    	Set pFileSystem = Server.CreateObject("Scripting.fileSystemObject")
    End Sub

	' ---- [Private] Chk if we are using LocalHost
	Private Sub ChkIsLocalHostConnection()

		Dim strRemoteHost
		Dim strLocalHost

		strRemoteHost = CStr(Request.ServerVariables(IDS_ACCESS_REMOTE_ADDR))
		strLocalHost = CStr(Request.ServerVariables(IDS_ACCESS_LOCAL_ADDR))

		If (strLocalHost = IDS_LOCAL_HOST_ID) OR (strRemoteHost = IDS_LOCAL_HOST_ID) OR _
		   (strLocalHost = strRemoteHost) Then
			m_bIsLocalHost = True
		End If
	End Sub



	' ---- [Private] Chk is SSL is running
	Private Sub SetupSSLRunningFlag()

		Dim strSSLStatus 

		strSSLStatus = CStr(Request.ServerVariables(IDS_ACCESS_HTTPS))

		If strSSLStatus = "on" Then
			m_bIsSSLRunning = True
		End If

	End Sub

End Class
%>