<!--          RIBCL Sample Script for Integrated Lights-Out          -->
<!--   Copyright (c) 2003 Hewlett-Packard Development Company, L.P.  -->

<!-- Description:  This is a sample XML script to configure the      -->
<!--               SNMP and Insight Manager integration settings for -->
<!--               an Integrated Lights-Out management processor.    -->

<!-- NOTE:  You will need to replace the USER_LOGIN and PASSWORD     -->
<!--        and other values inside the quotation marks with values  -->
<!--        that are appropriate for your environment.               -->
<!--        Use CPQLOCFG.EXE ver 2.10 or greater with this script    -->
<!--        This script was written for iLO firmware ver 1.50 or     -->
<!--        higher.                                                  -->
<!--        See the iLO User Guide for more information on scripting -->
<!--        and the syntax of the RIBCL XML.                         -->

<RIBCL VERSION="2.0">
  <LOGIN USER_LOGIN="adminname" PASSWORD="password">
  <RIB_INFO MODE="write">
    <MOD_SNMP_IM_SETTINGS>
      <WEB_AGENT_IP_ADDRESS value="192.168.125.120"/>
      <SNMP_ADDRESS_1 value="192.168.125.121"/>
      <SNMP_ADDRESS_2 value="192.168.125.122"/>
      <SNMP_ADDRESS_3 value="192.168.125.123"/>
      <OS_TRAPS value="Yes"/>
      <SNMP_PASSTHROUGH_STATUS value="Yes"/>
      <RIB_TRAPS value="No"/>
      <CIM_SECURITY_MASK value="3"/>
    </MOD_SNMP_IM_SETTINGS>
  </RIB_INFO>
  </LOGIN>
</RIBCL>