Topaz 4.1 Tivoli TEC SNMP adapter
=================================

General
==========
These files enable integration between Topaz alerts and the Tivoli TEC application. 

To view SNMP traps on the Tivoli TEC console, you should update Tivoli with the structure of the MIB and with the specific trap types. This patch updates files on the TEC SNMP adapter. 

To update Tivoli TEC:

1. Stop the TEC SNMP adapter process.
2. Add the contents of the following two files (copy-append) to the TEC SNMP adapter files.
    The original file located at  ...\Tivoli\lcf\bin\{$Platform}\TME\TEC\adapters\etc
	    - topaz.oid into tecad_snmp.oid
	    - topaz.cds into tecad_snmp.cds
3. Import the event class specification, located in the topaz.barroc file, into the desired TEC RuleBase.
	For more information see the help on "wrb" in the Tivoli Enterprise Console Reference Manual and the Tivoli Enterprise Console Adapters Guide.
4. Restart the Event Server.
5. Restart the TEC SNMP adapter.
6. To verify that the update succeeded, send Topaz SNMP traps to the TEC SNMP adapter, and check that they appear on the Tivoli TEC console.

Requirements
===============
Topaz 5.0

Installation Notes
=====================
- N/A