Home  Administration > Data Collector Administration > SiteScope Administration > Installing SiteScope > Copying SiteScope Configurations



Copying SiteScope Configurations

If you have earlier versions of SiteScope running in your environment which you want to upgrade to the current SiteScope version, you use the Copy Monitor Configuration utility to transfer existing monitor configurations. This utility provides a convenient tool for moving configuration data from one SiteScope installation to another.

The Copy Monitor Configuration utility is accessed through the SiteScope classic interface after the installation procedure is complete. It is not accessible through the new interface. For more information on how to access this utility, see Copying Configuration Data.

Note: Not all SiteScope configuration data is copied by the copy utility. For information on data that is not copied by this utility, see Limitations.

Usage

Use this utility if you are upgrading from an earlier version of SiteScope. The copy operation should be used to copy configuration data to a new SiteScope 8.0 or 8.1 installation only before any other configurations are made to the new installation. You can use this utility to copy existing SiteScope 8.0 or 8.1 configurations from one installation to another.

Note: You can manually copy configuration data files from an existing SiteScope installation to a new SiteScope 8.0 or 8.1 installation. The SiteScope installation into which you are copying configurations must not be running at the time that you paste the files into their respective directories on the new installation. This is to avoid possible configuration conflicts with the new configuration mechanism in SiteScope 8.0 or 8.1.

Requirements

The following are requirements for successfully copying SiteScope configuration data to a SiteScope 8.0 or 8.1 installation.

Limitations

The following are some important limitations in using the Copy Monitor Configurations utility:

Copying Configuration Data

You use the following steps to copy SiteScope monitor configurations from one SiteScope to another.

To copy SiteScope configurations:

  1. Access the SiteScope setup page of the current version in the SiteScope Classic interface. Normally, this page will be presented when you open SiteScope using the Classic interface port number for the first time after installation and before any groups or monitors have been created. On Windows platforms, you can click on the Open SiteScope Classic link on the Open SiteScope page. On all platforms, you can open the setup page URL using the following syntax:
  2. http://<sitescope_host>:8888/SiteScope/cgi/go.exe/SiteScope?page=setup

  3. On the setup page, click the Copy button at the bottom portion of the page. The Copy Monitor Configurations dialogue page opens.
  4. Enter the host name or address of the server where the previous version of SiteScope is running in the Remote SiteScope Server Address and Port field. Include the port number that the source SiteScope is listening on. By default, SiteScope listens on port 8888.
  5. Enter the administrator user name for the previous version of SiteScope in the SiteScope Administrator User Name field and the corresponding administrator password in the SiteScope Administrator Password field. Note that these are the user name and password configured in the User Preferences on the remote SiteScope and not the user name and password to login to the remote server through the file system. If no administrator user is defined for the source SiteScope, leave these fields blank.
  6. If you want to use the HTTPS secure protocol for the data transfer, click the check box for the Use HTTPS item.
  7. If you must use a proxy server to communicate with the source SiteScope, enter the applicable connection information in the Proxy Server, Proxy Server User Name, and Proxy Server Password fields.
  8. If the International Version option is enabled in the source SiteScope (see the General Preferences page), click the International Version check box on the Copy Monitor Configuration screen.
  9. Click the Copy button to continue. A copy confirmation screen opens.
  10. Click the Copy button to start the copy operation. A progress display screen opens.

Note: If successful, the copy operation automatically restarts the new SiteScope installation and processes the copied configurations. You will need to make a new Web browser request for the SiteScope interface after SiteScope has restarted by entering the appropriate address and port number. For example, the new SiteScope 8.0 interface is available at http://<sitescope_host>:8080/SiteScope/. The SiteScope Classic interface is available at http://<sitescope_host>:8888/SiteScope.




Copyright 2006 Mercury Interactive Corporation