Administration > Data Collector Administration > SiteScope Administration > External Integrations and Functionality > Mercury Self-Alert Monitor > Working with the Mercury Self-Alert Monitor Group > Managing the Mercury Self-Alert Monitor Group
Managing the Mercury Self-Alert Monitor Group
You can make various modifications and updates to the Mercury Self-Alert Monitor Group once you have set up the group.
Disabling the Mercury Self-Alert Monitor Group
You can disable the Mercury Self-Alert Monitor group, and prevent the group from appearing in the SiteScope Preferences pages.
To disable the Mercury Self-Alert Monitor group:
- Locate the file master.config, in the <SiteScope root directory>\groups folder.
Note: Before making any changes to this file, back up the original file to a safe location.
- Open the master.config file using a plain text editor.
- Find the key _disableTopazWatchdog= and set the value to true.
- Save the changes to the file.
- Stop and restart the SiteScope service.
Updating the Mercury Self-Alert Monitor Path
If the Mercury Business Availability Center you want to monitor is installed on a volume other than volume C of the remote server, you must change the path of the Mercury Business Availability Center folder in the Mercury Self-Alert Monitor configuration file on the SiteScope machine. You use the following steps to update the path to the folder.
To update the Mercury Business Availability Center path:
- Open the watchdog.config file in the <SiteScope root directory>\groups folder.
- Locate the row with the pattern _twdTopazFolder=C$\Mercury Application Management.
- Change the letter C in the value string to the be the volume drive letter on which Mercury Business Availability Center is installed.
- If the Mercury Business Availability Center installation folder is shared, write the name by which it is shared. For example, if the Mercury Business Availability Center installation folder is shared by the name AppManagement, replace C$\MercuryAM with AppManagement.
- Save the changes to the configuration file.
- Stop and restart the SiteScope service.
Reconfiguring a Mercury Self-Alert Monitor Component
You can reconfigure a specific Mercury Self-Alert Monitor component.
To reconfigure a Mercury Self-Alert Monitor component:
- In the SiteScope Classic interface, click Preferences > Mercury BAC to open the Mercury Business Availability Center Server Registration page.
- In the Mercury Business Availability Center Machine View table, clear the check box of the machine whose monitors you want to reconfigure.
- Click Save Settings.
- In the Self-Alert Monitor Configuration Result page, click Edit Mercury Self-Alert Monitor Settings.
- In the Mercury Business Availability Center Machine View table, select the check box of the machine whose components you want to reconfigure.
- Click Save Settings.
Creating a Baseline for the Mercury Self-Alert Monitor Group
Following setup, SiteScope begins monitoring the Mercury Business Availability Center machines registered in the Mercury Business Availability Center Management database. You must now bring the Mercury Self-Alert Monitor group to the state where all monitors have an OK status, that is, the Self-Alert Monitor group icon in the SiteScope main view is green. In this way, you can create a reliable baseline against which you can compare subsequent monitor results.
| Copyright 2006 Mercury Interactive Corporation |