Home  Administration > Data Collector Administration > SiteScope Administration > External Integrations and Functionality > Integration with Mercury Business Availability Center > Reporting Status per Measurement



Reporting Status per Measurement

By default, SiteScope reports status to Mercury Business Availability Center based on the status of the monitor. When measurements are included in Mercury Business Availability Center reporting, the monitor passes its status to the monitor's individual measurements. The monitor's status is calculated based on worst child. This means that the status for all the measurements in a monitor are calculated based on the monitor's worst child and not the status of the measurement itself. Also, if a measurement does not have its own status, it is reported to have the monitor's status.

You can now configure SiteScope to report the status for each measurement based on the individual measurement's status and not based only on the monitor's status. This enables Mercury Business Availability Center to more accurately report status for the monitor and its measurements.

To configure reporting monitor status per measurement:

  1. Open the master.config file found in the <SiteScope root directory>\groups directory.
  2. Change the value of the _enableQualityPerMetric property to true. (By default, this value is false which means that status is reported per monitor.)



Copyright 2006 Mercury Interactive Corporation