Administration > Monitor Administration > SiteScope Data Collector Configuration > Managing SiteScope > SiteScope Preferences > SiteScope General Preferences > Configuring General Preferences Properties
Configuring General Preferences Properties
Use the following steps to configure General Preferences properties.
To configure General Preferences properties:
- Expand the SiteScope container element for which you want to configure the General Preferences properties and click on the Preferences container for that SiteScope. The content panel displays the Preferences container contents.
- Click on the General Preferences link under the applicable container in the right hand panel. If necessary, click on the Properties tab in the upper right hand corner of the right hand panel to display the General Preferences Properties panel.
- Click the Edit button at the bottom of the Properties panel. The Edit General Preferences page is displayed in the content panel.Alternately, you can right-click the General Preferences container in the left menu tree to display the container action menu and select Edit Defaults.
- Complete the items in the Main Settings section as described below.
- When the required settings are defined, click the Ok button to save the General Preferences settings.
Main Settings
You use the Main Settings section of the General Preferences Properties page to enable monitoring, options, and features controlled by the General Preferences settings. Complete the items for the General Preferences Properties as described below.
License Number
Enter your SiteScope license number to register your SiteScope monitors. This number is issued to you when you purchase a set of monitors. You must purchase a license if you intend to use SiteScope beyond the trial period.
License Status
This line displays information about the license as entered in the License Number box above. This includes the total number of monitor points permitted by the license and how many points have been used plus a label for any optional monitor license keys entered below.
Option Licenses
If you have purchased licensing for optional SiteScope monitoring capability, enter the license number in this text box. Normally, this license key will have a syntax similar to the SiteScope license entered above. If you have purchased multiple license keys, enter each key separated with a comma.
Locale-specific Date and Time
You select this option to have SiteScope display dates and times in a format that is applicable to a certain locale, country, or culture. The locale setting for the United States (US) is used by default. In order to use a different locale setting, you must modify the SiteScope configuration file to include the codes for the locale you want to use and select this option in the General Preferences Settings. Use the following steps to over-ride the default locale used by SiteScope:
To set a new locale to be used by SiteScope:
- Edit the master.config file in the <SiteScope install path>/SiteScope/groups directory.
- Find the entry "_localeCountry=", and assign it an uppercase 2-character ISO-3166 country code. You can find a full list of these codes at a number of sites, such as http://www.chemie.fu-berlin.de/diverse/doc/ISO_3166.html. For example: _localeCountry=US
- Find the entry "_localeLanguage=", and assign it a lowercase 2-character ISO-639 language code. You can find a full list of these codes at a number of sites, such as http://www.ics.uci.edu/pub/ietf/http/related/iso639.txt. For example: _localeLanguage=en
- Save the master.config file, and then restart the SiteScope service.
International Version
Check this option to enable international character sets. When this option is checked, SiteScope honors all character encodings. Use this option to instruct SiteScope to simultaneously handle character encodings from multiple sources and operating systems (for example, foreign language web pages). If not checked, only the default character set of the operation system where SiteScope installed is supported. The exceptions are all the URL monitor types, the Log File Monitor, and the File Monitor. These monitor types support multiple character encoding regardless of the International Version option setting.
Number of backups per file
Enter the number of SiteScope configuration file backups that you want to keep. This feature is to help preserve important monitor, alert, and general SiteScope configuration information (for example, the files in the <SiteScope install path>/SiteScope/groups directory). This number represents that number of backups per file that will be maintained. SiteScope will use a naming convention of filename.bak.1, filename.bak.2, ... filename.bak.#, where 1 is the latest backup file.