Go to Table of Contents for Storage Management Online Help

Enclosures and Backplanes

Dell OpenManage™ Storage Management User's Guide

  Backplanes

  Enclosures

  Thermal Shutdown for Enclosures

  Changing the Mode on PV220S and PV221S Enclosures

  Enclosure Management

  Enclosure and Backplane Health

  Enclosure and Backplane Properties and Tasks

  Set Asset Data

  Set Temperature Probe Values

  EMM Properties

  Fan Properties

  Power Supply Properties

  Temperature Probe Properties

Array disks can be contained in an enclosure or attached to the system's backplane. An enclosure is attached to the system externally while the backplane and its array disks are internal.

Backplanes

You can view the Backplane object by expanding the Controller and Channel object in the Storage Management tree view. Storage Management displays the status of the backplane and attached array disks. Although a backplane is similar to an enclosure in that it is attached to a controller channel and has array disks, it does not have the management features (temperature probes, alarms, and so on) associated with external enclosures.

Enclosures

Storage Management enables management of various enclosures and their components. In addition to managing the array disks contained in the enclosure, you can monitor the status of the enclosure's fans, power supply, and temperature probes. You can view these components by expanding the Controller, Channel, and Enclosure objects in the Storage Management tree view.

Storage Management displays the properties of the enclosure's fans, power supply, and temperature probes. Storage Management also notifies you of enclosure status changes through alerts that are displayed in the Alert Log.

The following sections provide more information on the enclosure components and management features provided by Storage Management:

Enclosure Array/Hard Disks

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

The enclosure's array disks are displayed under the enclosure object in the tree view. Selecting a disk in the tree view displays the disk's status information.

Enclosure Fans

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

The fans are a component of the enclosure's cooling module. The fans are displayed by expanding the enclosure object in the tree view. You can select the Fans object to display their status information.

Enclosure Power Supplies

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

The enclosure's power supplies are displayed under the Power Supplies object in the tree view. You can select the Power Supplies object to display their status information.

Enclosure Temperature Probes

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

The enclosure's temperature probes are displayed under the Temperature Probes object. You can select the Temperature Probes object to display their status information. The status information includes the current temperature in celsius and the Warning and Failure thresholds for the temperature probe. The Failure threshold has a default value that cannot be changed. You can set the Warning threshold, however. See Set Temperature Probe Values for information on setting the warning threshold.

For information related to the enclosure's temperature, see the following:

Enclosure Management Modules (EMMs)

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

The Enclosure Management Modules (EMMs) that are installed in the enclosure are displayed under the EMMs object in the tree view. You can select the EMMs object to display the individual EMM modules and their status information.

The enclosure may contain one or more EMMs. The EMM modules monitor components of the enclosure. These components include:

When the enclosure's alarm is enabled, the EMM activates the alarm when certain conditions occur. For more information on enabling the alarm and the conditions that activate the alarm, see "Enable Alarm (Enclosure)." For more information on EMMs, see the enclosure hardware documentation.

All EMM modules in the enclosure should have the same version of firmware. You can view the properties of each individual EMM module to verify the firmware version.

Thermal Shutdown for Enclosures

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, and 3/Di controllers

Enclosure management provides a feature which automatically shuts down the operating system, the server, and the enclosure when the enclosure's temperature reaches dangerous extremes. The temperature when shutdown occurs is determined by the enclosure temperature probe's Minimum Failure Threshold and the Maximum Failure Threshold. These thresholds are default settings that cannot be changed.

Note: Thermal shutdown does not apply to the Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers.

Thermal Shutdown for the PV20xS and PV21xS Enclosures

For the PV20xS and PV21xS enclosures, the operating system shuts down and the server powers off when the enclosure reaches 0 degrees celsius or 50 degrees celsius. After the server powers off, the enclosure also powers off.

Thermal Shutdown for the PV220S and PV221S Enclosures

For the PV220S and PV221S, the operating system and server shut down at 0 degrees celsius or 50 degrees celsius if you have not implemented Channel Redundancy and Thermal Shutdown. If you have implemented channel redundancy enabled smart thermal shutdown using the command line interface (CLI), then only the enclosure shuts down at 0 degrees celsius or 50 degrees celsius. This will not result in data loss because redundant data resides on the enclosure attached to the other channel.

The PV220S and PV221S enclosures automatically shut down when their temperature reaches 55 degrees celsius. This shutdown occurs whether or not you have implemented channel redundancy or have Storage Management installed.

You can enable smart thermal shutdown using the command line interface. See omconfig Enable Smart Thermal Shutdown for more information.

Changing the Mode on PV220S and PV221S Enclosures

When toggling the bus configuration switch on a PV220S or PV221S enclosure, the enclosure should be powered on. The bus configuration switch is used to change the enclosure to split bus, joined bus, or clustered mode. If you change the PV220S or PV221S enclosure mode with the enclosure powered off, the enclosure may no longer be displayed by Storage Management and you may notice other erratic behaviors. In addition, the bus configuration switch on these enclosures is not rated for frequent toggling.

Enclosure Management

In addition to the drop-down menu Enclosure Tasks, the following activities may be required for enclosure management.

The Prepare to Remove task does not apply to the PERC 4/IM, CERC ATA100/4ch, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers.

If you have already removed the wrong drive, see Recovering from Removing the Wrong Drive.

Enclosure and Backplane Health

This screen displays the status of the enclosure or backplane and the components attached to the enclosure or backplane.

Enclosure and Backplane Status

Component status is indicated by the severity. A component with a Warning or Critical/Failure status requires immediate attention to avoid data loss if possible. It may be useful to review the Alert Log for events indicating why a component has a Warning or Critical status. For additional troubleshooting information, see Alert Messages and Troubleshooting.

The component status displayed on this screen reflects the status at a given point in time. If you believe the status has changed and wish to update this screen, select the controller's Information/Configuration tab and execute the Rescan task.

Severity

Component Status

Normal/OK. The component is working as expected.

Warning/Non-critical. A probe or other monitoring device has detected a reading for the component that is above or below the acceptable level. The component may still be functioning, but it could fail. The component may also be functioning in an impaired state. Data loss is possible.

Critical/Failure/Error. The component has either failed or failure is imminent. The component requires immediate attention and may need to be replaced. Data loss may have occurred.

Enclosure and Backplane Information

For information on enclosures and backplanes, see the following topics:

Enclosure and Backplane Components

For information on attached components, see the following topics:

Enclosure and Backplane Properties and Tasks

Use this window to view information about the enclosure or backplane and execute enclosure tasks.

Enclosure and Backplane Properties

The enclosure or backplane properties can vary depending on the model of the controller. Enclosure or backplane properties may include:

Property

Definition

These icons represent the severity or health of the storage component. See Storage Component Severity for more information.

Name

This property displays the name of the enclosure or backplane.

State

This property displays the current status of the enclosure or backplane. Possible values are:

    • Ready — The enclosure or backplane is functioning normally.

    • Degraded — The enclosure or backplane has suffered a failure of a component and is operating in a degraded state.

    • Failed — The enclosure or backplane has suffered a failure of one or more components and is no longer functioning. Storage Management may also be unable to communicate with the enclosure or using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage Management for any reason. For example, disconnecting the SCSI cable would cause this state to be displayed.

Channel

This property displays the number of the channel to which the enclosure or backplane is attached. This number matches the channel number on the controller hardware.

Target ID

This property displays the SCSI ID of the backplane (internal to the server) or the enclosure to which the controller channel is attached. The value is usually 6.

Configuration

This property displays the mode in which the enclosure is operating. Possible values are:

  • Joined Bus — Indicates that the enclosure is operating in joined-bus mode. A joined bus is indicated by a symbol depicting two unattached triangles on the back of the enclosure.

  • Split Bus — Indicates that the enclosure is operating in split-bus mode. A split bus is indicated by a single triangle symbol on the back of the enclosure.

  • Clustered — Indicates that the enclosure is operating in cluster mode. Clustered mode is only available on cluster-enabled RAID controllers. See Cluster-enabled RAID Controllers for more information.

For more information on joined, split, and cluster modes, see the enclosure hardware documentation. For information on how to cable the enclosure to accommodate these different modes, see the enclosure hardware documentation.

Note: When toggling the bus configuration switch on a PV220S or PV221S enclosure, the enclosure should be powered on. See Changing the Mode on PV220S and PV221S Enclosures for more information.

Kernel Version

This property displays the version of the non-upgradable firmware.

Service Tag

This property displays the enclosure's service tag number. This number is required when talking to Dell support. You can use this number to identify a specific enclosure in your environment by matching this number with the number on the service tag affixed to the enclosure. For example, if you have multiple enclosures and one of them experiences a failure, you can use the service tag number to identify which enclosure has failed.

Asset Tag

This property displays the asset tag information for the enclosure. You can change this property using the Set Asset Data task.

Asset Name

This property displays the name assigned to the enclosure. You can change this property using the Set Asset Data task.

Application Version

This property displays the version of the upgradable firmware.

Backplane Part Number

This property displays the part number of the enclosure's backplane.

Split Bus Part Number

This property displays the part number of the enclosure's split bus module. A split bus is indicated by a single triangle symbol on the back of the enclosure.

SCSI Rate

This property displays the SCSI speed.

Enclosure Alarm

This property displays whether the enclosure's alarm is enabled or disabled.

Enclosure Tasks

Do the following to execute a drop-down menu enclosure task:

  1. Expand the Storage tree object to display the controller objects.

  2. Expand a controller object.

  3. Expand a channel object.

  4. Select the enclosure object.

  5. Select the Information/Configuration subtab.

  6. Select a task from the Available Tasks drop-down menu.

  7. Click Execute.

Drop-down Menu Enclosure Tasks:

Enable Alarm (Enclosure)

Use the Enable Alarm task to enable the enclosure alarm. When enabled, the audible alarm sounds whenever the fault LED lights. This may occur to signal events such as:

Disable Alarm (Enclosure)

Use the Disable Alarm task to disable the enclosure alarm. When disabled, the alarm does not sound when the enclosure exceeds a warning threshold for temperature or experiences other error conditions such as a failed fan, power supply, or controller. If the alarm is already sounding, you can turn it off with this task.

Set Asset Data

Use the Set Asset Data task to specify the enclosure's asset tag and asset name. See Set Asset Data for more information.

Set Temperature Probe Value

Use the Set Temperature Probe Values task to specify the Warning and Failure thresholds for the enclosure's temperature probes. See Set Temperature Probe Values for more information.

Identifying an Open Channel for the Enclosure

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020 and LSI 1030 controllers

If you have not yet attached the enclosure to an open channel, you may need to identify a channel on the controller that can be used for this purpose. To identify an open channel:

  1. Expand the Storage Management tree view until the controller object is expanded. When the controller object is expanded, the tree view displays the controller's channels. These channels are numbered starting from zero.

  2. Identify a channel that is not attached to storage. If the channel is already attached to storage, then the channel object can be expanded to display an enclosure or backplane and the attached array disks. A channel object that cannot be expanded in the tree view is an open channel not currently attached to storage. Storage Management displays a number for each channel. These numbers correspond to the channel numbers on the controller hardware. You can use these numbers to identify which open channel displayed in the tree view is the open channel on the controller hardware.

Checking the Enclosure's Temperature

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers

To check the enclosure's temperature:

  1. Expand the tree view until the Temperature Probes object is displayed.

  2. Select the Temperature Probes object. The temperature reported by the temperature probe is displayed in celsius in the Reading column in the right pane.

For information related to the enclosure's temperature, see the following:

Verifying the Enclosure's EMM Firmware Version

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers

The firmware for the Enclosure Management Modules (EMMs) must be at the same level. To verify the EMM firmware version:

  1. Expand the tree view until the EMMs object is displayed.

  2. Select the EMMs object. The firmware version for each EMM is displayed in the Firmware Version column in the right pane.

For information related to the enclosure's EMMs, see Enclosure Management Modules (EMMs).

Enclosure Components

For information on attached components, see the following topics:

Set Asset Data

You can change the enclosure's asset tag and asset name. The new asset tag and asset name that you specify are displayed on the enclosure's Information/Configuration subtab.

To change the enclosure's asset tag and asset name:
  1. Type the new asset tag name in the New asset tag text box. You can specify an inventory number or other useful information for your environment. The asset tag typically refers to the enclosure hardware.

  2. Type the new asset name in the New asset name text box. You can specify a name useful to you for organizing your storage environment. For example, the asset name could refer to the type of data stored on the enclosure or to the enclosure's location.

  3. Click Apply Changes. If you wish to exit and cancel your changes, click Go Back To Enclosure Information Page.

To locate this task in Storage Management:
  1. Expand the Storage tree object to display the controller objects.

  2. Expand a controller object.

  3. Expand a channel object.

  4. Select the enclosure object.

  5. Select the Information/Configuration subtab.

  6. Select Set Asset Data from the Available Tasks drop-down menu.

  7. Click Execute.

Set Temperature Probe Values

The temperature probes monitor the enclosure's temperature. Each temperature probe has a Warning and a Failure threshold. The Warning threshold indicates that the enclosure is approaching an unacceptably warm or cool temperature. You can modify the Warning threshold.

The Failure threshold indicates that the enclosure has reached a dangerous temperature that may cause damage and data loss. You cannot change the default values for the Failure threshold.

To change the temperature probe's Warning threshold:
  1. The enclosure's temperature probes are listed in the Temperature Probes section of the screen. Select the probe that you want to change.

  2. Select Set new values in the Set New Temperature Probe Values section of the screen.

  3. Type the lowest acceptable temperature in celsius for the enclosure in the Minimum Warning Threshold text box. The text box label indicates the range that you can specify.

  4. Type the highest acceptable temperature in celsius for the enclosure in the Maximum Warning Threshold text box. The text box label indicates the range that you can specify.

  5. Click Apply Changes.

If you wish to return the temperature probe's Warning threshold to the default values, select the Reset to default values button and click Apply Changes.

To locate this task in Storage Management:
  1. Expand the Storage tree object to display the controller objects.

  2. Expand a controller object.

  3. Expand a channel object.

  4. Select the enclosure object.

  5. Select the Information/Configuration subtab.

  6. Select Set Temperature Probe Values from the Available Tasks drop-down menu.

  7. Click Execute.

EMM Properties

Use this window to view information about the Enclosure Management Modules (EMMs).

EMM Properties

Property

Definition

Status

These icons represent the severity or health of the storage component. See Storage Component Severity for more information.

Name

This property displays the name of the EMM.

State

This property displays the current status of the EMMs.

  • Ready — The EMM is functioning normally.

  • Degraded — The EMM has suffered a failure and is operating in a degraded state.

  • Failed — The EMM has suffered a failure and is no longer functioning. Storage Management may also be unable to communicate with the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage Management for any reason. For example, disconnecting the SCSI cable would cause this state to be displayed.

Part Number

This property displays the part number of the EMM module.

Firmware Version

This property indicates the version of the firmware loaded on the EMM. All EMM modules in the enclosure should have the same level of firmware.

SCSI Rate

This property displays the maximum SCSI speed that the EMM supports.

Fan Properties

Use this window to view information about the enclosure's fans.

Fan Properties

The fans are a component of the enclosure's cooling module. The following table describes the fan properties.

Property

Definition

Status

These icons represent the severity or health of the storage component. See Storage Component Severity for more information.

Name

This property displays the name of the fan.

State

This property displays the current status of the fan.

  • Ready — The fan is functioning normally.

  • Degraded — The fan has suffered a failure and is operating in a degraded state.

  • Failed — The fan has suffered a failure and is no longer functioning. Storage Management may also be unable to communicate with the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage Management for any reason. For example, disconnecting the SCSI cable would cause this state to be displayed.

Part Number

This property displays the part number of the fan.

Note: This property is not displayed for the PV22xS enclosures that have E.17 firmware or later.

Speed

This property indicates the fan speed. Possible values are Fast, Medium, Slow, and Stopped.

Power Supply Properties

Use this window to view information about the enclosure's power supplies.

Power Supply Properties

Property

Definition

Status

These icons represent the severity or health of the storage component. See Storage Component Severity for more information.

Name

This property displays the name of the power supply.

State

This property displays the current status of the power supply.

  • Ready — The power supply is functioning normally.

  • Degraded — The power supply has suffered a failure and is operating in a degraded state.

  • Failed — The power supply has suffered a failure and is no longer functioning. Storage Management may also be unable to communicate with the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage Management for any reason. For example, disconnecting the SCSI cable would cause this state to be displayed.

Part Number

This property displays the part number of the power supply.

Note: This property is not displayed for the PV22xS enclosures that have E.17 firmware or later.

Temperature Probe Properties

Use this window to view information about the enclosure's temperature probes.

Temperature Probe Properties

Property

Definition

Status

These icons represent the severity or health of the storage component. See Storage Component Severity for more information.

Name

This property displays the name of the temperature probe.

State

This property displays the current status of the temperature probe.

  • Ready — The temperature probe is functioning normally.

  • Degraded — The temperature probe has suffered a failure and is operating in a degraded state.

  • Failed — The temperature probe has suffered a failure and is no longer functioning. Storage Management may also be unable to communicate with the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage Management for any reason. For example, disconnecting the SCSI cable would cause this state to be displayed.

  • Minimum Warning Threshold Exceeded — The enclosure's temperature has dropped below the minimum warning threshold. See Set Temperature Probe Values for more information.

  • Maximum Warning Threshold Exceeded — The enclosure's temperature has risen above the maximum warning threshold. See Set Temperature Probe Values for more information.

Reading

This property displays the current temperature of the enclosure as reported by the temperature probe.

Warning Threshold

The Minimum and Maximum properties indicate the temperatures currently set for the Warning threshold. See Set Temperature Probe Values for more information.

Failure Threshold

The Minimum and Maximum properties indicate the temperatures currently set for the Failure threshold. See Set Temperature Probe Values for more information.

Set Temperature Probe Properties

Click the Set Temperature Probe button to launch the wizard for changing the temperature probe's Warning threshold. You can change the Warning threshold for each of the temperature probes included in the enclosure. See Set Temperature Probe Values for more information.

Do the following to launch the Set Temperature Probe wizard:

  1. Expand the Storage tree object to display the controller objects.

  2. Expand a controller object.

  3. Expand a channel object.

  4. Expand the enclosure object.

  5. Select the Temperatures object.

  6. Click Set Temperature Probe.


Go to Table of Contents for Storage Management Online Help