Serial Over LAN Configuration Advanced Settings       

Use this page to configure advanced settings for serial over LAN help.

Serial Over LAN Configuration

NOTE: The value of the character accumulate interval must be in the range of 1 to 255. The value of the character send threshold must also be in the range of 1 to 255. Any values entered out of this range will result in a pop-up menu prompting for a valid value.
Character Accumulate Interval This 1-based parameter specifies the character accumulate interval in 5 millisecond (ms) increments. The interval sets the typical amount of time that the baseboard management controller (BMC) waits before sending a partial serial over LAN (SOL) data packet. A  partial data packet is a packet that has fewer characters to send than the number of characters specified by the Character Send Threshold.
Character Send Threshold This parameter is 1-based. The BMC automatically sends an SOL data packet that contains this number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC.

[Back to Top]

Other Window Controls

Go Back To Serial Over LAN Configuration Page Click to return to the Serial Over LAN Configuration Page.
Apply Changes Saves a record of the values that have been entered or selected for each field.