Back to Contents Page

Subsystems

Dell OpenManage™ Array Manager User's Guide Version 3.6

  Subsystem Menu Commands

  View Report

  Save

  Enable Smart Thermal Shutdown

  Disable Smart Thermal Shutdown

  Subsystem Properties

This section applies to all subsystems supported by Array Manager.

A subsystem is a controller and all of the storage devices, such as disks and enclosures, that the controller manages. A subsystem may include a single controller, or several related controllers and their attached storage.

To view your storage subsystems in the Array Manager tree view, do the following:

  1. Expand the Arrays object. This action enables you to see your storage subsystems. Array Manager supports the following subsystems:

  2. Select a subsystem object and expand it until all of its lower-level objects are fully expanded. You can now see all of the controllers, disks, enclosures, and so forth included in the subsystem.

Note Because the controllers in each subsystem support different features, the objects in the expanded tree view may vary. For example, if a controller does not support a tape or CDROM device, then the Tape and CDROM objects are not displayed under that controller. For more information on the tree view, see "Tree View."

Subsystem Menu Commands

This section applies to the PERC Subsystem 1, PERC Subsystem 2, and the SCSI Subsystem.

The following sections describe pop-up menu commands for the PERC Subsystem 1, PERC Subsystem 2, and SCSI Subsystems. For information on the PV660F Subsystem, see "The Dell PowerVault 660F Storage System."

Right-click a subsystem in the Array Manager tree view to display its pop-up menu commands. Because the features for each subsystem can vary, your subsystem's pop-up menu may not display all of these commands.

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Subsystem Commands (PV660F)."


View Report

This section applies to the PERC Subsystem 1, PERC Subsystem 2, and the SCSI Subsystem.

This command enables you to view a report on the subsystem. The report indicates your system's controllers that belong to the subsystem and the virtual disks managed by those controllers. The report also provides additional information such as the virtual disk status, size and RAID type, as well as the array disk size, status, serial number and vendor.

To view a report on the subsystem:

  1. Right-click the subsystem object in the Array Manager tree view.

  2. Select View Report from the pop-up menu. This action displays the Report dialog which displays the status of the subsystem. To save the report to a file, click on the Save button.

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Subsystem Commands (PV660F)."


Save

This section applies to the PERC Subsystem 1, PERC Subsystem 2, and the SCSI Subsystem.

This command enables you to save the information provided by the View Report command to a file.

To save information on the subsystem's controllers, virtual disks, and array disks to a file:

  1. Right-click the subsystem object in the Array Manager tree view.

  2. Select Save from the pop-up menu.

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Subsystem Commands (PV660F)."


Enable Smart Thermal Shutdown

This section applies to a PERC Subsystem 1 or PERC subsystem 2 controller attached to an enclosure.

By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degrees celsius. If you have implemented Channel Redundancy on the PV220S and PV221S enclosures, however, you can specify that only the enclosure and not the operating system and server be shut down when the enclosure reaches a critical temperature of 0 or 50 degrees celsius.

Note You must perform this procedure on each of the server's subsystems in the Array Manager tree view in order to implement smart thermal shutdown.

To specify that only the enclosure shut down at critical temperatures:

  1. Right-click the PERC Subsystem 1 object in the Array Manager tree view.

  2. Select Enable Smart Thermal Shutdown from the pop-up menu.

For more information, see:

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Subsystem Commands (PV660F)."


Disable Smart Thermal Shutdown

This section applies to a PERC Subsystem 1 or PERC subsystem 2 controller attached to an enclosure.

If you have previously selected the Enable Smart Thermal Shutdown option, you can deselect this option and return the system to its default setting by selecting the Disable Smart Thermal Shutdown option. The Disable Smart Thermal Shutdown setting indicates that the operating system and the server will shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degrees celsius.

To specify that the operating system and server shut down at critical temperatures:

  1. Right-click the PERC Subsystem 1 object in the Array Manager tree view.

  2. Select Disable Smart Thermal Shutdown from the pop-up menu.

For more information, see:

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Subsystem Commands (PV660F)."


Subsystem Properties

This section applies to the PERC Subsystem 1, PERC Subsystem 2, and the SCSI Subsystem.

This command enables you to display the subsystem properties.

To display the subsystem properties:

  1. Right-click the subsystem object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Subsystem Properties dialog which displays the properties of the subsystem.

Subsystem properties may include:

For information on "The Dell PowerVault 660F Storage System" pop-up menu commands, see "Array Disk Commands (PV660F)."


Back to Contents Page