Back to Contents Page
Dell OpenManage Array Manager User's Guide Version 3.5
Description of SCSI Subsystem Controllers
SCSI Subsystem Commands
SCSI Subsystem Controller Commands
SCSI Subsystem Channel Commands
SCSI Subsystem Hard Disk Commands
SCSI Subsystem Tape Properties
SCSI Subsystem CDROM Commands
This chapter describes how to configure and manage arrays attached to non-RAID SCSI subsystem controllers. You can display your system's non-RAID SCSI subsystem controllers in the Array Manager tree view by doing the following:
- Expand the Arrays object in the Array Manager tree view hierarchy.
- Expand the SCSI Subsystem object. This action displays the non-RAID SCSI controllers included in your system.
The following controllers are supported by the SCSI subsystem:
- Adaptec Ultra SCSI Controllers (40 MB device speed). These controllers include the 3944UW, 2944UW, AIC-7860, and AIC-7880 controllers. The AIC-7860 and AIC-7880 controllers are an ASIC embedded on the motherboard.
- Adaptec Ultra2 SCSI Controllers (80 MB device speed). These controllers include the 2940U2W and AIC-7890 controllers. The AIC-7890 controllers are an ASIC embedded on the motherboard.
- Adaptec Ultra160 SCSI Controllers (160 MB device speed). These controllers include the 39160, 29160LP, AIC-7899, and AIC-7892 controllers. The AIC-7892 and AIC-7899 controllers are an ASIC embedded on the motherboard.
The SCSI subsystem controllers are non-RAID controllers that support SCSI devices. Because these controllers are non-RAID, they do not support virtual disks. You can manage these non-RAID controllers and their attached SCSI devices with Array Manager.
The Ultra SCSI controllers supported by Array Manager are a high voltage differential (HVD) SCSI drop-in controller that fits in a PCI slot on the server or is embedded in the server. This controller can be used to attach HVD devices such as an HVD tape drive.
The Ultra2 SCSI and Ultra160 SCSI controllers are low voltage differential (LVD) drop-in controllers that fit in a PCI slot on the server or are embedded in the controller. These controllers can be used to attach external enclosures and other LVD SCSI devices.
Array Manager also supports RAID controllers on which you can create virtual disks. For information on these controllers, see the following:
- PERC Subsystem 1 Controllers: PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4/IM, and CERC ATA100/4ch (SCSI controllers)
- PERC Subsystem 2 Controllers: PERC 2, 2/Si, 3/Si, and 3/Di (SCSI controllers)
- The Dell PowerVault 660F Storage System (fiber channel controller)
The SCSI subsystem has the following commands on its pop-up menu:
This command enables you to view a report on the SCSI subsystem. The report indicates the current status of the SCSI controller.
To view a report on the SCSI subsystem:
- Right-click the SCSI Subsystem object in the Array Manager tree view.
- Select View Report from the pop-up menu. This action displays the Report dialog which displays the status of the SCSI subsystem. To save the report to a file, click on the Save button.
This command enables you to save the controller configuration.
To save the controller configuration:
- Right-click the SCSI Subsystem object in the Array Manager tree view.
- Select Save from the pop-up menu.
This command enables you to display the SCSI subsystem properties.
To display the SCSI subsystem properties:
- Right-click the SCSI Subsystem object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the Subsystem Properties dialog which displays the properties of the SCSI subsystem.
SCSI subsystem properties may include:
- Name This field displays the name of the SCSI subsystem object in the Array Manager tree view.
- Vendor This field displays the SCSI subsystem vendor's name.
- Status This field displays the current status of the SCSI subsystem. Possible values are:
- Ready The SCSI subsystem is functioning normally.
- Degraded The SCSI subsystem has suffered a failure of a component and is operating in a degraded state.
- Failed The SCSI subsystem has suffered a failure of one or more components and is no longer functioning.
- Type This field indicates the type of storage component. For SCSI subsystem properties, the value in this field is "Subsystem."
This section describes the following controller commands:
This operation can be used to check whether there are any new disks that were attached after a controller configuration was set.
- Right-click the controller you want to rescan.
- Click Rescan. After the operation is finished, the console is refreshed and the newly attached disks (if there are any) appear under the Array Group object in the tree view.
 |
Note The addition of a hard disk is only reflected in the tree view by performing the
Rescan operation.
|
This command enables you to display the properties for a SCSI subsystem controller.
To display the controller properties:
- Right-click the controller object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the Controller Properties dialog which displays the properties of the controller.
Controller properties may include:
- Name This field displays the name of the controller object in the Array Manager tree view.
- Vendor This field displays the controller vendor's name.
- Status This field displays the current status of the controller. Possible values are:
- Ready The controller is functioning normally.
- Degraded The controller has suffered a failure of a component and is operating in a degraded state.
- Failed The controller has suffered a failure of one or more components and is no longer functioning.
- Type This field indicates the type of storage component. For controller properties, the value in this field is "Controller."
- SCSI ID This field indicates the controller processor's SCSI ID.
This section describes the following channel commands:
This operation can be used to check whether there are any new disks that were attached to the SCSI channel after a configuration was set.
- Right-click the channel you want to rescan.
- Click Rescan. After the operation is finished, the console is refreshed and the newly attached disks (if there are any) appear under the Array Group object in the tree view.
 |
Note The addition of a disk is only reflected in the tree view by performing the Rescan
operation.
|
This command enables you to display the channel properties.
To display the channel properties:
- Right-click the channel object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the Channel Properties dialog which displays the channel properties.
Channel properties may include:
- Name This field displays the name of the channel object in the Array Manager tree view.
- Vendor This field displays the channel vendor's name.
- Status This field displays the current status of the channel. Possible values are:
- Ready The channel is functioning normally.
- Degraded The channel has suffered a failure of a component and is operating in a degraded state.
- Failed The channel has suffered a failure of one or more components and is no longer functioning.
- Type This field indicates the type of storage component. For channel properties, the value in this field is "Channel."
- Channel Termination This field indicates the type of outlet the channel has for attaching other devices.
- SCSI Data Rate This field displays the SCSI speed.
This section describes the following hard disk commands:
The Blink command allows you to locate a particular hard disk by blinking the light-emitting diodes (LEDs) on the disk carrier. This command will automatically cancel after a short duration such as 30 or 60 seconds.
When using an Ultra SCSI, Ultra2 SCSI, or Ultra160 SCSI controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.
To blink a hard disk:
- Right-click the disk object in the tree view.
- Select Blink from the pop-up menu.
The Unblink command allows you to cancel the Blink command before the 30 or 60-second threshold has been reached.
When using an Ultra SCSI, Ultra2 SCSI, or Ultra160 SCSI controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.
To unblink hard disk:
- Right-click the disk object in the tree view.
- Select Unblink from the pop-up menu.
You can display the properties for the hard disks attached to the SCSI subsystem. These hard disks are non-RAID array disks.
To display the hard disk properties:
- Right-click the hard disk object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the Array Disk Properties dialog which displays the hard disk properties.
Hard disk properties may include:
- Disk This field displays the name of the hard disk object in the Array Manager tree view.
- Type This field indicates the type of storage component. For hard disk properties, the value in this field is "Array Disk."
- Status This field displays the current status of the hard disk. Possible values are:
- Ready The hard disk is functioning normally.
- Degraded The hard disk has suffered a failure of a component and is operating in a degraded state.
- Failed The hard disk has suffered a failure of one or more components and is no longer functioning.
- Capacity This field displays the total capacity of the hard (array) disk.
- Unallocated Space This field displays the available space on the hard (array) disk.
- Device Type This field displays the SCSI devices or system ports to which the hard disk is attached.
- Target ID This field displays the SCSI ID of the hard disk.
- Hardware Vendor This field displays the hard disk's hardware vendor.
- Product ID This field displays the hard disk's product ID.
- Revision This field displays the hard disk's revision number.
- Serial Number This field displays the hard disk's serial number.
This section describes the following tape commands:
You can eject media inserted in the tape drive.
To eject a tape from the tape drive:
- Right-click the tape object in the Array Manager tree view.
- Select Eject from the pop-up menu.
 |
Note Tape drives do not always support the Eject command.
|
You can display the properties for tape devices attached to the SCSI subsystem.
To display the tape properties:
- Right-click the tape object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the Tape Properties dialog which displays the tape properties.
Tape properties may include:
- Name This field displays the name of the tape object in the Array Manager tree view. The last digit of the name indicates the tape's SCSI ID.
- Vendor This field displays the tape vendor's name.
- Status This field displays the current status of the tape device. Possible values are:
- Ready The tape device is functioning normally.
- Degraded The tape device has suffered a failure of a component and is operating in a degraded state.
- Failed The tape device has suffered a failure of one or more components and is no longer functioning.
- No Media The tape device does not have available storage tape.
- Type This field indicates the type of storage component. For tape properties, the value in this field is "Tape."
- Hardware Vendor This field displays the tape hardware vendor's name.
- Product ID This field displays the product ID of the tape device.
- Revision This field displays the revision number of the tape device.
- Serial Number This field displays the serial number of the tape device.
This section describes the following CDROM commands:
You can load media inserted in the CDROM drive.
To load media on a CDROM:
- Insert the CDROM in the CDROM drive.
- Right-click the CDROM object in the Array Manager tree view.
- Select Load from the pop-up menu.
You can eject media inserted in the CDROM drive.
To eject a CDROM from the CDROM drive:
- Right-click the CDROM object in the Array Manager tree view.
- Select Eject from the pop-up menu.
You can display the properties for CDROM devices attached to the SCSI subsystem.
To display the CDROM properties:
- Right-click the CDROM object in the Array Manager tree view.
- Select Properties from the pop-up menu. This action displays the CDROM Properties dialog which displays the CDROM properties.
CDROM properties may include:
- Name This field displays the name of the CDROM object in the Array Manager tree view. The last digit of the name indicates the CDROM's SCSI ID.
- Vendor This field displays the CDROM vendor's name.
- Status This field displays the current status of the CDROM device. Possible values are:
- Ready The CDROM device is functioning normally.
- Degraded The CDROM device has suffered a failure of a component and is operating in a degraded state.
- Failed The CDROM device has suffered a failure of one or more components and is no longer functioning.
- No Media The CDROM device does not have a CDROM available.
- Type This field indicates the type of storage component. For CDROM properties, the value in this field is "CDROM."
- Hardware Vendor This field displays the tape hardware vendor's name.
- Product ID This field displays the product ID of the tape device.
- Revision This field displays the revision number of the tape device.
- Capacity This field indicates the available capacity on the CDROM.
Back to Contents Page