SCSI Subsystem Controllers: Ultra SCSI, Ultra2 SCSI, and Ultra160 SCSI

Dell OpenManage™ Array Manager User's Guide Version 3.5

  Description of SCSI Subsystem Controllers

  SCSI Subsystem Commands

  SCSI Subsystem Controller Commands

  SCSI Subsystem Channel Commands

  SCSI Subsystem Hard Disk Commands

  SCSI Subsystem Tape Properties

  SCSI Subsystem CDROM Commands

This chapter describes how to configure and manage arrays attached to non-RAID SCSI subsystem controllers. You can display your system's non-RAID SCSI subsystem controllers in the Array Manager tree view by doing the following:

  1. Expand the Arrays object in the Array Manager tree view hierarchy.

  2. Expand the SCSI Subsystem object. This action displays the non-RAID SCSI controllers included in your system.

The following controllers are supported by the SCSI subsystem:


Description of SCSI Subsystem Controllers

The SCSI subsystem controllers are non-RAID controllers that support SCSI devices. Because these controllers are non-RAID, they do not support virtual disks. You can manage these non-RAID controllers and their attached SCSI devices with Array Manager.

The Ultra SCSI controllers supported by Array Manager are a high voltage differential (HVD) SCSI drop-in controller that fits in a PCI slot on the server or is embedded in the server. This controller can be used to attach HVD devices such as an HVD tape drive.

The Ultra2 SCSI and Ultra160 SCSI controllers are low voltage differential (LVD) drop-in controllers that fit in a PCI slot on the server or are embedded in the controller. These controllers can be used to attach external enclosures and other LVD SCSI devices.

Array Manager also supports RAID controllers on which you can create virtual disks. For information on these controllers, see the following:


SCSI Subsystem Commands

The SCSI subsystem has the following commands on its pop-up menu:

View Report

This command enables you to view a report on the SCSI subsystem. The report indicates the current status of the SCSI controller.

To view a report on the SCSI subsystem:

  1. Right-click the SCSI Subsystem object in the Array Manager tree view.

  2. Select View Report from the pop-up menu. This action displays the Report dialog which displays the status of the SCSI subsystem. To save the report to a file, click on the Save button.

Save

This command enables you to save the controller configuration.

To save the controller configuration:

  1. Right-click the SCSI Subsystem object in the Array Manager tree view.

  2. Select Save from the pop-up menu.

Properties

This command enables you to display the SCSI subsystem properties.

To display the SCSI subsystem properties:

  1. Right-click the SCSI Subsystem object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Subsystem Properties dialog which displays the properties of the SCSI subsystem.

SCSI subsystem properties may include:


SCSI Subsystem Controller Commands

This section describes the following controller commands:

Rescan

This operation can be used to check whether there are any new disks that were attached after a controller configuration was set.

  1. Right-click the controller you want to rescan.

  2. Click Rescan. After the operation is finished, the console is refreshed and the newly attached disks (if there are any) appear under the Array Group object in the tree view.

Note The addition of a hard disk is only reflected in the tree view by performing the Rescan operation.

Properties

This command enables you to display the properties for a SCSI subsystem controller.

To display the controller properties:

  1. Right-click the controller object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Controller Properties dialog which displays the properties of the controller.

Controller properties may include:


SCSI Subsystem Channel Commands

This section describes the following channel commands:

Rescan

This operation can be used to check whether there are any new disks that were attached to the SCSI channel after a configuration was set.

  1. Right-click the channel you want to rescan.

  2. Click Rescan. After the operation is finished, the console is refreshed and the newly attached disks (if there are any) appear under the Array Group object in the tree view.

Note The addition of a disk is only reflected in the tree view by performing the Rescan operation.

Properties

This command enables you to display the channel properties.

To display the channel properties:

  1. Right-click the channel object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Channel Properties dialog which displays the channel properties.

Channel properties may include:


SCSI Subsystem Hard Disk Commands

This section describes the following hard disk commands:

Blink

The Blink command allows you to locate a particular hard disk by blinking the light-emitting diodes (LEDs) on the disk carrier. This command will automatically cancel after a short duration such as 30 or 60 seconds.

When using an Ultra SCSI, Ultra2 SCSI, or Ultra160 SCSI controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.

To blink a hard disk:

  1. Right-click the disk object in the tree view.

  2. Select Blink from the pop-up menu.

Unblink

The Unblink command allows you to cancel the Blink command before the 30 or 60-second threshold has been reached.

When using an Ultra SCSI, Ultra2 SCSI, or Ultra160 SCSI controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.

To unblink hard disk:

  1. Right-click the disk object in the tree view.

  2. Select Unblink from the pop-up menu.

Properties

You can display the properties for the hard disks attached to the SCSI subsystem. These hard disks are non-RAID array disks.

To display the hard disk properties:

  1. Right-click the hard disk object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Array Disk Properties dialog which displays the hard disk properties.

Hard disk properties may include:


SCSI Subsystem Tape Properties

This section describes the following tape commands:

Eject

You can eject media inserted in the tape drive.

To eject a tape from the tape drive:

  1. Right-click the tape object in the Array Manager tree view.

  2. Select Eject from the pop-up menu.

Note Tape drives do not always support the Eject command.

Properties

You can display the properties for tape devices attached to the SCSI subsystem.

To display the tape properties:

  1. Right-click the tape object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Tape Properties dialog which displays the tape properties.

Tape properties may include:


SCSI Subsystem CDROM Commands

This section describes the following CDROM commands:

Load

You can load media inserted in the CDROM drive.

To load media on a CDROM:

  1. Insert the CDROM in the CDROM drive.

  2. Right-click the CDROM object in the Array Manager tree view.

  3. Select Load from the pop-up menu.

Eject

You can eject media inserted in the CDROM drive.

To eject a CDROM from the CDROM drive:

  1. Right-click the CDROM object in the Array Manager tree view.

  2. Select Eject from the pop-up menu.

Properties

You can display the properties for CDROM devices attached to the SCSI subsystem.

To display the CDROM properties:

  1. Right-click the CDROM object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the CDROM Properties dialog which displays the CDROM properties.

CDROM properties may include:


Back to Contents Page