Dell OpenManage Array Manager User's Guide Version 3.6
Installation Considerations for a SAN
Installing Array Manager on Windows
Understanding Array Manager on NetWare Installation
Unattended (Silent) Installation
Upgrading the Windows Operating System
This chapter explains how to install Dell OpenManage Array Manager, including hardware and software requirements, upgrade information, and installation types and components. There will also be a section about uninstall.
Before installing, you should:
![]() |
Note Array Manager can be installed from more than one source, including the Dell OpenManage Applications CD, the Array Manager CD, and from the Dell support site. Throughout this online help, these installation sources may be referred to as the Array Manager CD or the Array Manager installation media. |
This overview section contains the following topics:
Array Manager has the following installation components:
You can install these components using the following installation options:
When using Express Install on a Windows 2000 server, Array Manager replaces the native Windows 2000 Disk Management, the built-in disk and volume manager that comes with Windows 2000. Array Manager extends the functionality of Disk Management by providing both hardware and software RAID management, while maintaining the disk and volume functions originally found in the Windows 2000 Disk Management.
If you do not wish to replace the Windows 2000 Disk Management during installation, then use the Custom Install.
After replacing the Windows 2000 Disk Management, if you uninstall Array Manager, the Disk Management program will be restored to its original state.
![]() |
Note Disk Management is not disabled on a system that has a console-only installation of Array Manager. |
For information on Array Manager and Windows Disk Management, see "Array Manager and Windows Disk Management."
In order to provide non-RAID SCSI disk and enclosure management, Array Manager requires the Advanced SCSI Programming Interface (ASPI) driver. The 4.6 version of this driver is installed with the Array Manager management console.
![]() |
Note The Adaptec aspi32.sys driver version 4.6 that is installed by Array Manager has not passed the WHQL certification tests that are recommended by Microsoft. Running Microsoft's Driver Verifier against this driver will report problems with the driver. It is recommended that Microsoft's Driver verifier not be run once Array Manager has been installed. |
Array Manager installs the ASPI 4.6 driver as part of the management console installation. The ASPI 4.6 driver provides a programming interface to SCSI devices.
The ASPI driver is a legacy driver and does not adhere to Microsoft's standards for security access. For this reason, the presence of the ASPI driver on a system can be considered a security risk. It is not recommended that the ASPI driver be installed on a server that is not secure or that has public access.
If you choose to uninstall the ASPI driver, Array Manager will no longer provide non-RAID SCSI disk and enclosure management. See "Uninstalling the ASPI 4.6 Driver" for more information.
Array Manager cannot be installed on a system that has the ASPI 4.7.x driver installed.
If you have the ASPI 4.7.x driver installed on your system, you need to remove this driver and install the ASPI 4.6 driver. You can do this by downloading the ASPI 4.6 package from http://support.dell.com. The ASPI 4.6 package uninstalls the ASPI 4.7.x driver and installs the ASPI 4.6 driver. Refer to the documentation of any other applications installed on the system to see if those applications have known problems with the ASPI 4.6 driver.
You can remove the ASPI 4.6 driver that has been installed by Array Manager. To do so, download the ASPI 4.6 package from http://support.dell.com. This package is designed to uninstall existing versions of the ASPI 4.7.x driver and install the ASPI 4.6 driver in its place. This package also contains the remvaspi.bat script which uninstalls the ASPI 4.6 driver.
After downloading the ASPI 4.6 package, do the following to remove the ASPI 4.6 driver from your system:
The following sections describe the Array Manager installation requirements:
Please see the Readme file for the latest information.
The following requirements apply to any system running the Array Manager console (client) or the Array Manager managed system (server):
The Array Manager console and managed system have additional system requirements. For information on these requirements as well as the supported operating systems, see the following:
![]() |
Note After Array Manager is installed, the Windows Add/Remove Programs utility may incorrectly report the Array Manager installation to be smaller than it is. For the correct disk space requirements, refer to the "Management Console Requirements (Client)" and the "Managed System for Windows Requirements (Server)" sections. |
![]() |
Note If you intend to web serve Array Manager, Internet Information Services (including the World Wide Web Server component) must be installed on the Web server prior to installing Array Manager. Use the Windows server installation media to install Internet Information Services. If you install Internet Information Services after installing Array Manager, you will need to Add/Modify (reinstall) Array Manager before web serving an Array Manager installation. |
![]() |
Note Dell provides configuration utilities that enable you to perform certain RAID management operations using the PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, and PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers on platforms not currently supported by Array Manager. These utilities are available at http://support.dell.com. |
The following are minimum requirements for installing the Array Manager console. The console is the client portion of Array Manager. For the latest information, see the Readme file.
![]() |
Note It is highly recommended that you use the most current service pack. |
The following are minimum requirements for installing a managed system for Windows. For the latest information, see the Readme file.
![]() |
Note It is highly recommended that you use the most current service pack. |
![]() |
Note The managed system's RAID controllers must be attached to storage in order to run Array Manager. |
The following are minimum requirements for installing a managed system for NetWare. For the latest information, see the Readme file.
![]() |
Note The managed system's RAID controllers must be attached to storage in order to run Array Manager. |
![]() |
Note Dell does not offer NetWare in Japan. |
Internet Explorer version 4.0 or later is required for launching and viewing the online help from the Array Manager console. In addition to the online help, the Array Manager installation directory includes documentation in HTML and PDF format. The total space requirement for the online help and documentation is 15 MB.
Array Manager uses the host operating system's native security policies. These govern access rights to the Array Manager managed system. You need Administrator level access rights to install and use Array Manager.
When installing an Array Manager managed system onto a Windows server connected to a Storage Area Network (SAN), you must take the following into consideration:
During installation on a Windows server connected to a SAN or a PowerVault 660F, you will be asked whether this managed system will manage a PowerVault 660F storage system. Answer "Yes" for only one Windows server on each PowerVault 660F storage system. The only exception to this is if the server is part of an MSCS cluster. You can set up the Array Manager managed system on both servers of the MSCS cluster to manage the PowerVault 660F storage system, but only one server should be used to manage the RAID array at a time.
![]() |
Note Each PowerVault 660F in a storage area network (SAN) should only be managed by one Array Manager managed system. If you configure more than one Array Manager managed system to manage a PowerVault 660F storage system, then each managed system may not be able to view all events generated by the fibre channel RAID controllers in the PowerVault 660F storage system. |
If you answer "Yes" to manage a PowerVault 660F storage system, you may be asked whether you want to manage it in a Direct Attach configuration. Answer "Yes" only if the following is true:
The Setup program takes you through the process of installing the Array Manager software. Before proceeding, you should exit all Microsoft Windows programs and log on with Administrator rights.
This section includes the following subtopics:
For other information on installation considerations, see the following:
Use the following procedure to install Array Manager using the Dell OpenManage Systems Management CD:
Use the following procedure to install Array Manager using the Dell OpenManage Array Manager CD:
![]() |
Note When installing the managed system (server) on a Windows 2000 or Windows Server 2003 system, the Plug and Play Manager will activate after the reboot, indicating that it has discovered new hardware. You may be required to perform a second reboot if dynamic disks are present on your system. Otherwise, allow Plug and Play to register the new driver. (This occurs automatically.) |
You can install the Array Manager managed system (server) on a NetWare server and then connect to the NetWare server from the Array Manager console.
Installing Array Manager on NetWare involves the following activities:
![]() |
Note Dell does not offer NetWare in Japan. |
Array Manager requires that the NWASPI.CDM driver be installed on NetWare in order to provide non-RAID SCSI support. The NWASPI.CDM driver can be optionally installed when installing the NetWare operating system. If you did not install the NWASPI.CDM driver when you installed NetWare, then you need to install it now. If you do not install the NWASPI.CDM driver, then Array Manager will still function on NetWare, but support for non-RAID SCSI controllers will not be available.
It is preferable to install the NWASPI.CDM driver before installing Array Manager on NetWare.
Depending on which version of NetWare you have, use one of the following procedures:
![]() |
Note Dell does not offer NetWare in Japan. |
Use the NetWare configuration utility to install the NWASPI.CDM driver on NetWare 5.x.
Use the NetWare hdetect utility to install the NWASPI.CDM driver on NetWare 6.5.
The hdetect utility displays a list of device types and drivers.
The Storage devices option is displayed under Device types. If Storage devices is not already displayed, select Continue until the Storage devices option is displayed.
Use this procedure if the Array Manager install media is located on a Windows system. This would be the case, for example, if you have downloaded the Array Manager installation media from the Dell support site to a Windows system.
Installing the Array Manager managed system (server) on a NetWare server requires the AMINST.NLM and AMINST.IPS files. If these files are located on a Windows system, you can map a drive to the NetWare server and then copy the AMINST.NLM and AMINST.IPS files from the Windows system to the NetWare server. You would then go to the NetWare server and complete the installation.
Installing Array Manager using this method requires that the Novell client be installed on the Windows system from which you are mapping a drive to the NetWare server.
For more information on NetWare installation considerations, see the following:
Use the following steps to install the Array Manager managed system on the NetWare server from a mapped drive.
Unzip the Array Manager installation package.
\AM<n>\NetWare
where <n> represents an Array Manager version number. For example, <n> might be specified as 35, 36, 37, 38 and so on.
The Array Manager installation displays messages indicating if you do not have the required drivers installed on the NetWare system. You may wish to observe the installation so as to take note of any required drives that need to be loaded. If your system has the required drivers, the installation completes with the following message:
If your system does not have the required drivers, the installation completes with the following message:
Install successful (Restart required)
In this case, you must load the required drivers and restart the NetWare server. To restart the NetWare server, enter restart server at the NetWare system console command prompt
After installing the Array Manager managed system on a NetWare server, you can connect to the NetWare server from the Array Manager console. For more information on connecting to a managed system from the console, see "Connecting to a Remote System from the Console."
For information on starting the Array Manager service on NetWare, see "Starting the Array Manager Service for the First Time."
For information on enabling NetWare support for the PowerVault 660F, see "NetWare Support for the PowerVault 660F."
![]() |
Note Dell does not offer NetWare in Japan. |
If you have an installation CD, you install the Array Manager managed system directly on the NetWare server.
![]() |
Note If a version of Array Manager is already installed on the NetWare system, then uninstall that version before continuing with the install of a new version of Array Manager. See "Uninstalling Array Manager on NetWare" for information on uninstallation. |
For more information on NetWare installation considerations, see the following:
![]() |
Note Dell does not offer NetWare in Japan. |
Use the following steps to install the Array Manager managed system (server) on the NetWare server using an installation CD.
<VolumeName>:\AM<n>\NetWare
where <n> represents an Array Manager version number. For example, <n> might be specified as 35, 36, 37, 38 and so on.
The Array Manager installation displays messages indicating if you do not have the required drivers installed on the NetWare system. You may wish to observe the installation so as to take note of any required drives that need to be loaded. If your system has the required drivers, the installation completes with the following message:
If your system does not have the required drivers, the installation completes with the following message:
Install successful (Restart required)
In this case, you must load the required drivers and restart the NetWare server. To restart the NetWare server, enter restart server at the NetWare system console command prompt
After installing the Array Manager managed system on a NetWare server, you can connect to the NetWare server from the Array Manager console. For more information on connecting to a managed system from the console, see "Connecting to a Remote System from the Console."
For information on starting the Array Manager service on NetWare, see "Starting the Array Manager Service for the First Time."
For information on enabling NetWare support for the PowerVault 660F, see "NetWare Support for the PowerVault 660F."
You can install Array Manager on a Windows remote machine without requiring user input on the remote machine. You can use this procedure, for example, to install Array Manager on several different machines from a single location.
When performing the unattended installation, you run an install script that contains the steps required to complete the installation on the remote machine. There are two possibilities for using the install script:
If you are using a prerecorded script, you will perform the Performing an Unattended Installation procedure to complete the installation on a remote machine.
<Setup.exe> is the full directory path to the setup.exe script.
Use this procedure to perform an unattended installation. This procedure assumes that you either have access to the Array Manager install media, or that you have created your own install script.
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\
Uninstall\{4536C827-30C2-11D4-A22F-00A0C9EA31FB}\UninstallString
where <IP address> is the IP address of the remote server.
<Setup.exe> -s -f1"<InstallScript.iss>"
<Setup.exe> and <InstallScript.iss> are the full directory paths to the setup.exe and install script at the location you identified in step 1 of this procedure. The <InstallScript.iss> should be enclosed in quotation marks. There is no space between -f1 and "<InstallScript.iss>".
After you have installed Array Manager, you can modify, repair, or remove components of the installation through the Windows Control Panel. This section covers changes to all installed components except uninstalling Array Manager from the NetWare system, which is covered in the next section.
![]() |
Note To make changes in the installation, you must be logged on with Administrator rights and you must exit the Array Manager application. |
![]() |
Note If you uninstall Array Manager or modify, repair, or remove installation components, you may notice that events generated before the uninstall, modify, repair, or remove no longer display an event description. This situation occurs when the component that generated the event is no longer installed on the system. If you wish to preserve the events and their descriptions, you should back up or export the event log before you uninstall Array Manager, or modify, repair, or remove installation components. |
To change the Array Manager installed components:
This option allows you to change the components that are installed on your system. Checked components will be installed. Unchecked components will not be installed and will be removed if they are currently installed.
|
Caution If you do not select a component that you currently have installed, this component will be removed. |
This option automatically detects which components you currently have installed on your system and reinstalls those components.
This option completely removes Array Manager from your Windows system. For uninstalling Array Manager from a NetWare system, see "Uninstalling Array Manager on NetWare" for more information.
![]() |
Note Files that were in use during the uninstall will not be deleted until you reboot the server. |
You may wish to upgrade an Array Manager installation to a newer version of Array Manager. When doing so, it is recommended that you uninstall the old version of Array Manager before installing the new one. See "Uninstalling Array Manager" for more information.
It is also recommended that you uninstall Array Manager before upgrading the Windows operating system. See "Upgrading the Windows Operating System" for more information.
![]() |
Note If you uninstall Array Manager or modify, repair, or remove installation components, you may notice that events generated before the uninstall, modify, repair, or remove no longer display an event description. This situation occurs when the component that generated the event is no longer installed on the system. You can clear the event log to remove these events. See "Clearing Events". If you wish to preserve the events and their descriptions, you should back up or export the event log before you uninstall Array Manager, or modify, repair, or remove installation components. See "Backing Up and Restoring Events" and "Exporting Events to a Text File". |
The Array Manager installation process installs files and makes registry entries on the server that are specific to the operating system. For this reason, changing the operating system can disable Array Manager. To avoid this problem, you should uninstall Array Manager before upgrading the Windows operating system. See "Uninstalling Array Manager" for more information.
After the upgrade, reinstall Array Manager using the Array Manager install media or by downloading Array Manager from the Dell support site at http://support.dell.com.
If you have already upgraded without uninstalling Array Manager and are now experiencing problems, see "Resolving Windows Upgrade Problems."
This section discusses uninstalling Array Manager.
![]() |
Note If you uninstall Array Manager or modify, repair, or remove installation components, you may notice that events generated before the uninstall, modify, repair, or remove no longer display an event description. This situation occurs when the component that generated the event is no longer installed on the system. You can clear the event log to remove these events. See "Clearing Events". If you wish to preserve the events and their descriptions, you should back up or export the event log before you uninstall Array Manager, or modify, repair, or remove installation components. See "Backing Up and Restoring Events" and "Exporting Events to a Text File". |
There are two methods for uninstalling Array Manager on Windows.
![]() |
Note Array Manager appears in the Add/Remove Programs list, whether it was installed using Array Manager or Server Administrator. |
Use the following procedure to uninstall Array Manager from a NetWare system.
![]() |
Note Dell does not offer NetWare in Japan. |
If you need to uninstall Array Manager from more than one machine, you can do so using an unattended or "silent" uninstall. Unattended uninstall enables you to uninstall Array Manager from several remote machines at the same time without requiring user input.
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\
Uninstall\{4536C827-30C2-11D4-A22F-00A0C9EA31FB}\UninstallString
where <IP address> is the IP address of the remote machine.
<setup.exe> -s /u -f1"<uninstall.iss>"
<setup.exe> and <uninstall.iss> are the full directory paths to the setup.exe and uninstall.iss scripts at the location you identified in step 1 of this procedure. The <uninstall.iss> should be enclosed in quotation marks. There is no space between the -f1 and "<uninstall.iss>".
The <uninstall.iss> script uninstalls Array Manager from the remote machine.