Back to Contents Page

Enclosures

Dell OpenManage™ Array Manager User's Guide Version 3.6

  Enclosure Components in the Tree View

  Thermal Shutdown

  Enclosure Array/Hard Disks

  Enclosure Fans

  Enclosure Power Supplies

  Enclosure Temperature Probes

  Enclosure Management Modules (EMMs)

  Enclosure Menu Commands

  Enclosure Procedures

  Enclosure Properties

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

Array Manager enables management of various enclosures and their components. These enclosures include:

In addition to managing the array disks contained in the enclosure, you can monitor the status of the enclosure's fans, power supply, and temperature probes. You can view these components in the Array Manager tree view.

Array Manager displays the properties of the enclosure's fans, power supply, and temperature probes. Array Manager also notifies you of enclosure status changes through events that are displayed on the Events tab and logged in the Windows event log.

The following sections provide more information on the enclosure components managed by Array Manager:


Enclosure Components in the Tree View

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

When you expand the storage subsystem object in the Array Manager tree view, you see the controllers attached to the storage subsystem. The controller object expands to display the controller's channels. These channel objects are numbered in the Array Manager tree view to match the channel number that appears on the controller hardware. (See the controller's documentation for information on identifying the channels on the controller hardware.) For example, if the controller has two channels numbered 0 and 1, then the channel objects in the Array Manager tree view are named Channel 0 and Channel 1.

If the controller has a channel connected to an enclosure, then this connection is reflected in the channel name displayed in the tree view. For example, if Channel 1 is connected to an enclosure, then the channel object's name in the tree view is Enclosure (Channel 1).

Expanding the enclosure channel object displays the enclosure's fans, power supply, and temperature probes. Each of these objects expands to display the individual fans and so forth provided by the enclosure.

In the following graphic, the enclosure object is expanded to show the EMMs, fans, power supplies, temperature probes, and array disks included in the enclosure. Because the enclosure is connected to channel 2 of the controller, the enclosure's default name is Enclosure (Channel 2).

Enclosure Management Storage Objects

For more information on the enclosure's components, commands, and the array disks included in the enclosure, see the following sections:


Thermal Shutdown

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, and 3/Di controllers.

Enclosure management provides a feature which automatically shuts down the operating system, the server, and the enclosure when the enclosure's temperature reaches dangerous extremes. The temperature when shutdown occurs is determined by the enclosure temperature probe's Minimum Error Threshold and the Maximum Error Threshold. These thresholds are default settings that cannot be changed.

Thermal Shutdown for the PV20xS and PV21xS Enclosures

For the PV20xS and PV21xS enclosures, the operating system shuts down and the server powers off when the enclosure reaches 0 degrees celsius or 50 degrees celsius. After the server powers off, the enclosure also powers off.

On NetWare, Array Manager requires that the Dell OpenManage Server Agent (OMSA) 4.0.0 or later be installed on the managed system to provide thermal shutdown for the PV20xS and PV21xS enclosures. If the Server Agent is not installed, then only the operating system shuts down when the enclosure reaches 0 degrees celsius or 50 degrees celsius.

Thermal Shutdown for the PV220S and PV221S Enclosures

For the PV220S and PV221S enclosures, the operating system and server shut down at 0 degrees celsius or 50 degrees celsius if you have not implemented Channel Redundancy and Thermal Shutdown. If you have implemented channel redundancy (and also selected the Enable Smart Thermal Shutdown option), then only the enclosure shuts down at 0 degrees celsius or 50 degrees celsius. This will not result in data loss because redundant data resides on the enclosure attached to the other channel.

The PV220S and PV221S enclosures automatically shut down when their temperature reaches 55 degrees celsius. This shutdown occurs whether or not you have implemented channel redundancy or have Array Manager installed.

Note On NetWare, the Dell OpenManage Server Agent (OMSA) 4.0.0 or later should be installed on the managed system in order to provide a graceful shutdown of the operating system without the risk of data loss.

For more information on the Enable Smart Thermal Shutdown option, see "Enable Smart Thermal Shutdown."

Channel Redundancy and Thermal Shutdown

It is possible to create a virtual disk that uses array disks that are attached to different controller channels. The array disks may reside in an external enclosure or the backplane (internal enclosure). If the virtual disk is maintaining redundant data on different channels, then the virtual disk is channel redundant. Channel redundancy means that if one of the channels fails, data will not be lost because redundant data resides on another channel.

Channel redundancy might also be used for disks that reside in enclosures subject to thermal shutdown. Should the enclosure attached to one of the channels shut down, redundant data is maintained on the other channel.

Channel redundancy is implemented by selecting array disks on different channels when using the Advanced Mode of the Create Virtual Disk wizard.

Note Channel redundancy only applies to controllers that have more than one channel and that attach to an external disk enclosure.
Considerations for Implementing Channel Redundancy on PERC 3/DCL, 3/DC, 3/QC, 4/DC, 4e/DC, 4/Di, and 4e/Di controllers.
Creating a Channel-redundant Virtual Disk on PERC 2/DC, 3/DCL, 3/DC, 3/QC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, and 3/Di controllers.

The following instructions describe creating a virtual disk that uses channel redundancy.

  1. If the Quick Access window is not already displayed, display this window by selecting the Quick Access Window option from the View pull-down menu.

  2. Click the Create Virtual Disk button on the Quick Access Window.

  3. Click the Advanced Mode button.

  4. Specify the virtual disk properties. These include the name, RAID type, stripe size, and read, write, and cache policy for the virtual disk. See "Virtual Disk Properties" for more information.

For PERC 2/DC, 3/DCL, 3/DC, 3/QC, 4/DC, 4e/DC, 4/Di, and 4e/Di controllers: It is recommended that you only use RAID 10 or RAID 50.

For PERC 2 and 3/Di controllers: It is recommended that you only use RAID 10 or Concatenation of RAID-1.

  1. Click Uncheck All. This action deselects all array disks displayed in the Available Disks portion of the wizard. Deselecting the disks enables you to make your own custom selection.

  2. Depending on the controller type:

For PERC 2/DC, 3/DCL, 3/DC, 3/QC, 4/DC, 4e/DC, 4/Di, and 4e/Di controllers:

Use the tabs in the Available Disks portion of the wizard to select array disks on different channels. There are specific RAID level and configuration requirements for implementing channel redundancy. You must select the same number of array disks on each channel that you use. Refer to the "Number of Array Disks per Virtual Disk" section for information on the number of array disks that can be used for different RAID levels. Refer to the "Supported RAID Levels (PERC Subsystem 1)" section for information on controller-specific implementations of the RAID levels.

RAID 10

  • Select one array disk on each of two channels. (In other words, each of the two channels will have a single disk selected.)
  • Click Add Span.
  • Select an additional disk on each of the two channels and click Add Span. You have now selected the minimum number of disks for a RAID 10.
  • Repeat step c until you have the desired number of disks.
  • Click Finish.

    RAID 50

  • Select one array disk on each of three channels. (In other words, each of the three channels will have a single disk selected.)
  • Click Add Span.
  • Select an additional disk on each of the three channels and click Add Span. You have now selected the minimum number of disks for a RAID 50. Continue selecting a disk on each channel until you have selected the desired number of disks.
  • Repeat step c until you have the desired number of disks.
  • Click Finish.

    For PERC 2 and 3/Di controllers:

    RAID 10 or Concatenation of RAID-1

  • Select one array disk on each of two channels. (In other words, each of the two channels will have a single disk selected.)
  • Click Add Span.
  • Select an additional disk on each of the two channels and click Add Span. You have now selected the minimum number of disks for a RAID 10 or Concatenation of RAID-1.
  • Repeat step c until you have selected the desired number of disks. You must select the same number of array disks on each channel that you use.
  • Click Finish.
    Related Information

    For information related to the enclosure's temperature, see the following:


    Enclosure Array/Hard Disks

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    The enclosure's array disks or hard disks are displayed under the enclosure object in the tree view. Selecting a disk in the tree view displays the disk's status information in the Tabs.

    If you right-click an array disk in the tree view, the Array Disks context menu is displayed.


    Enclosure Fans

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    The fans that are installed in the enclosure are displayed under the Fans object in the tree view. You can select the Fans object to display the individual fans and their status information in the right pane. You can also expand the Fans object to display the individual fans in the left pane.

    If you right-click the Fans object or an individual fan, a context menu is displayed with a Properties option. For more information on fan properties, see "Fan Properties."


    Enclosure Power Supplies

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    The power supplies that are installed in the enclosure are displayed under the Power Supplies object in the tree view. You can select the Power Supplies object to display the individual power supplies and their status information in the right pane. You can also expand the Power Supplies object to display the individual power supplies in the left pane.

    If you right-click the Power Supplies object or an individual power supply, a context menu is displayed with a Properties option. For more information on power supply properties, see "Power Supply Properties."


    Enclosure Temperature Probes

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    The temperature probes that are installed in the enclosure are displayed under the Temperature Probes object in the tree view. You can select the Temperature Probes object to display the individual temperature probes and their status information in the right pane. The status information in the includes the current temperature in celsius and the warning and error thresholds for the temperature probe. The error threshold has a default value that cannot be changed. You can set the warning threshold, however. See "Set Thresholds for Temperature" for information on setting the warning threshold.

    Right-clicking the temperature probes object in the left pane displays a context menu with a Properties option. You can also expand the temperature probe object to display the individual temperature probes in the tree view. Right-clicking an individual temperature probe also displays a context menu with a Properties option. This option enables you to set the minimum and maximum warning threshold for the temperature probe.

    For information related to the enclosure's temperature, see the following:


    Enclosure Management Modules (EMMs)

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    The Enclosure Management Modules (EMMs) that are installed in the enclosure are displayed under the EMMs object in the tree view. You can select the EMMs object to display the individual EMM modules and their status information in the right pane. You can also expand the EMMs object to display the individual EMM modules in the left pane.

    The enclosure may contain one or more EMMs. The EMM modules monitor components of the enclosure. These components include:

    When the enclosure's alarm is enabled, the EMM activates the alarm when certain conditions occur. For more information on enabling the alarm and the conditions that activate the alarm, see "Enable Alarm." For more information on EMMs, see the enclosure hardware documentation.

    If you right-click the EMMs object or an individual enclosure management module, a context menu is displayed with a Properties option. You can view the properties of each individual EMM module to verify that all EMM modules are at the same firmware level. (All EMM modules in the enclosure should have the same version of firmware.) For more information on enclosure management module properties, see "EMM Properties."

    For information on downloading firmware for an EMM module, see "Download Firmware."


    Enclosure Menu Commands

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    This section describes the commands associated with the enclosure and its fans, power supplies, and temperature probes.

    Right-clicking an enclosure object in the tree view displays a context menu with the enclosure commands. Right-clicking the enclosure's fans, power supplies, and temperature probes also displays context menu for these components.

    The commands on the enclosure's context menu can vary depending on the model of the enclosure. Enclosure context menu commands may include:

    The context menu commands for fans, power supplies, and temperature are:

    Rescan

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to rescan the enclosure. The Rescan command identifies any new array disks, fans, temperature probes, and so forth that have been added to the enclosure.

    To rescan the enclosure:

    1. Right-click the enclosure object in the tree view.

    2. Select Rescan from the context menu.

    Note If you downloaded firmware using an application other than Array Manager, rescan the controller to see the updated firmware version in the Array Manager console.

    Enable Alarm

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to enable the alarm. When enabled, the audible alarm sounds whenever the fault LED lights. This may occur to signal events such as:

    To enable the enclosure alarm:

    1. Right-click the enclosure object in the tree view.

    2. Select Enable Alarm from the context menu.

    Disable Alarm

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to disable the enclosure alarm. When disabled, the alarm does not sound when the enclosure exceeds a warning threshold for temperature or experiences other error conditions such as a failed fan, power supply, or controller. If the alarm is already sounding, you can turn it off with this function.

    To disable the alarm:

    1. Right-click the enclosure object in the tree view.

    2. Select Disable Alarm from the context menu.

    Set Tag Data

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to specify the asset tag information and the enclosure's name. When you specify the enclosure's name, the new name is displayed for the enclosure object in the tree view. You can also use this procedure to view the service tag number for the enclosure.

    To specify the asset information or view the enclosure's service tag number:

    1. Right-click the enclosure object in the tree view.

    2. Select Set Tag Data from the context menu. This action displays the Set Tag Data dialog. This dialog has the following fields: two entry boxes which can be modified: Asset Tag and Asset Name.

      • Service Tag — Displays the enclosure's service tag number. This number is required when talking to Dell support. You could also use this number to identify a specific enclosure in your environment by matching this number with the number on the service tag affixed to the enclosure. For example, if you have multiple enclosures in your environment, and one of them experiences a failure, you can use the service tag number to identify which enclosure has failed. You cannot modify this field.

      • Asset Tag — Displays the asset tag information for the enclosure. You can modify this field to display information (such as an inventory number) useful for your environment.

      • Asset Name — Displays the name assigned to the enclosure. You can modify this field. The name specified in the Asset Name field is also the name for the enclosure displayed in the Array Manager tree view.

    3. Specify the new values as required for the Asset Tag and the Asset Name.

    4. Click Apply and then Ok to make the changes. Click Cancel to exit the function without accepting the changes.

    Download Firmware

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to download firmware to the enclosure. When you use this command in a joined bus configuration, the firmware is downloaded to both of the EMM modules in the enclosure. If you are using split bus or cluster configuration, then you need to download the firmware to each channel to ensure that the firmware on both EMM modules is at the same level.

    This command assumes that the firmware is available on your system. If the firmware is not available on your system, it can be downloaded from the Dell support site at support.dell.com.

    If the enclosure is attached to a clustered controller, it is required that you shut down other systems in the cluster before downloading the firmware. See "Downloading Firmware and Cluster Controllers" for more information.

    On the PV220S and PV221S enclosures, you should stop I/O before downloading the firmware.

    Note If you downloaded firmware using an application other than Array Manager, rescan the controller to see the updated firmware version in the Array Manager console.
    Note The Download Firmware function is only available on the PV220S and PV221S enclosures.

    To download firmware to the enclosure:

    1. Right-click the enclosure object in the tree view.

    2. Select Download Firmware from the context menu. This action displays the Firmware Download dialog.

    3. Enter the path to the firmware in the Open field. You can also use the Browse button to locate the firmware.

    4. Click Download Firmware once the correct path to the firmware is displayed in the Open field. Note that if the unit is in split backplane mode and the two sides are connected to different servers, then the error message "EMM in Unknown state" might appear. You should ignore this message. The state of the EMM will return to normal after the firmware download has completed.

    Error Messages Associated with Downloading Firmware

    Downloading firmware on PV220S and PV221S enclosures may generate the following error messages:

    Set Thresholds for Temperature

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    Use this command to set the warning threshold for the enclosure's temperature probes.

    1. Expand the enclosure object in the tree view. This action displays the lower-level objects contained in the enclosure.

    2. Expand the Temperature Probes object in the tree view. This action displays the individual temperature probes.

    3. Right-click the temperature probe for which you are setting the warning threshold and select Properties from the context menu. This action displays the Temperature Probe Properties dialog.

    The Temperature Probe Properties dialog displays the current status of the temperature probe as well as the default values in celsius for the minimum and maximum error thresholds. The default values for the error thresholds indicate that the enclosure has reached a dangerous temperature that may cause damage. These default values cannot be changed.

    1. Enter the desired value in celsius for the minimum and maximum warning thresholds in the Minimum Warning Threshold and the Maximum Warning Threshold fields. The warning thresholds indicate that the enclosure is approaching an unacceptably warm or cool temperature.

    If you wish to apply your changes to all temperature probes in the enclosure, then select the Apply these values to all temperature probes in the enclosure check box.

    1. Click Apply and then Ok to make the changes. Click Cancel to exit the function without accepting the changes.

    For information related to the enclosure's temperature, see the following:


    Enclosure Procedures

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    This section describes procedures commonly used in association with enclosures. For additional information on enclosure commands and properties, see "Enclosure Menu Commands" and "Enclosure Properties."

    The enclosure procedures are as follows:

    The Prepare to Remove command does not apply to the Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    If you have already removed the wrong drive, see "Recovering from Removing the Wrong Drive."

    Identifying an Open Channel for the Enclosure

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    If you have not yet attached the enclosure to an open channel, you may need to identify a channel on the controller that can be used for this purpose. To identify an open channel:

    1. Expand the Array Manager tree view until the controller object is expanded. When the controller object is expanded, the tree view displays the controller's channels. These channels are numbered starting from zero.

    2. Identify a channel that is not attached to storage. When a controller's channel is attached to an enclosure or an array, the channel object can be expanded to display the disks included in the array or the enclosure. A channel object that cannot be expanded in the Array Manager tree view is an open channel not currently attached to storage. Array Manager displays a number for each channel. These numbers correspond to the channel numbers on the controller hardware. You can use these numbers to identify which open channel displayed in the tree view is the open channel on the controller hardware.

    Making a New Hard Drive Visible to Array Manager

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, and 3/Di controllers.

    After adding a new hard drive or array disk, you may find that the hard drive is not visible in the Array Manager tree view. To make the new hard drive visible in the tree view:

    1. Right-click the computer system object in the tree view.

    2. Select Rescan from the context menu.

    Viewing Enclosure Status Information and Event Messages

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    You can view the current status of an enclosure and its components. To view status information, select the object for which you wish to see the status in the tree view. In the right pane, the Status field indicates the current status. The possible values are:

    For information on enclosure events displayed in the Array Manager event log, see "Events Generated by the PERC 2/SC, 3/SC, 2/DC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4/IM, 4e/DC, 4e/Si, 4e/Di, CERC ATA100/4ch and the PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s Controllers."

    Checking the Enclosure's Temperature

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To check the enclosure's temperature, select a temperature probe object in the tree view. The temperature reported by the temperature probe is displayed in celsius in the Current Value field in the right pane.

    For information related to the enclosure's temperature, see the following:

    Verifying the EMM Firmware Version

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.
    Note If you downloaded firmware using an application other than Array Manager, rescan the controller to see the updated firmware version in the Array Manager console.

    The firmware for all Enclosure Management Modules (EMMs) in PV220S and PV221S enclosures should be the same version. To verify which firmware version a particular EMM module in an PV220S and PV221S enclosure has, do the following.

    1. Expand the Array Manager tree view until all EMM modules installed in the enclosure are displayed. This means expanding the EMMs object, since the individual EMM modules are at the level below the EMMs object in the tree view.

    2. Right-click the EMM object for which you wish to verify the firmware version and select Properties. The EMM Properties dialog displays. This dialog indicates the EMM module's firmware version.

    For information on downloading firmware for an EMM module, see "Download Firmware."


    Enclosure Properties

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To display the enclosure properties, do the following:

    1. Expand the controller object in the Array Manager tree view.

    2. Right-click the channel that is attached to the enclosure.

    3. Select Properties from the context menu.

    The enclosure properties can vary depending on the model of the enclosure. Enclosure properties may include:

    For more information on joined, split, and cluster modes, see the enclosure hardware documentation. For information on how to cable the enclosure to accommodate these different modes, see the enclosure's hardware documentation.

    You can also display the properties for the following enclosure components:

    EMM Properties

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To display the EMM properties, right-click the EMM object in the tree view and select Properties from the context menu.

    The EMM properties can vary depending on whether you select the EMMs folder in the tree view or expand the EMMs folder and select an individual EMM. The EMM properties can also vary depending on which enclosure you are using.

    EMM properties may include:

    Fan Properties

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To display the fan properties, right-click the fan object in the tree view and select Properties from the context menu.

    The fan properties can vary depending on whether you select the Fans folder in the tree view or expand the Fans folder and select an individual fan.

    Fan properties may include:

    Power Supply Properties

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To display the power supply properties, right-click the power supply object in the tree view and select Properties from the context menu.

    The power supply properties can vary depending on whether you select the Power Supplies folder in the tree view or expand the Power Supplies folder and select an individual Power Supply. Power Supply properties may include:

    Temperature Properties

    This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Di, PERC 2, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

    To display general properties for all of the temperature probes, right-click the top-level temperature probe object (the level directly under the controller object) and select Properties from the context menu. To set the temperature thresholds, see "Set Thresholds for Temperature."

    The temperature probe properties can vary depending on whether you select the Temperature Probes folder in the tree view or expand the Temperature Probes folder and select an individual temperature probe. Temperature probe properties may include:

    For information related to the enclosure's temperature, see the following:


    Back to Contents Page