Back to Contents Page

Disks

Dell OpenManage™ Array Manager User's Guide Version 3.6

  Windows Operating System Disks: Basic and Dynamic

  Working with Basic Disks

  Working with Dynamic Disks

  Dynamic Disk Limitations

  General Disk Functions

  Array and Hard Disk Menu Commands

This chapter describes conceptual and procedural information about how Array Manager implements basic and dynamic disks. It also includes general disk functions.

Note There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Windows Operating System Disks: Basic and Dynamic

On a Windows system, you can expand the Disks object in the Array Manager tree view to display the operating system disks recognized by Windows Disk Management. These operating system disks can be either basic or dynamic. In conceptual terms, a basic disk is similar to a hard disk in that it does not support RAID functions. A dynamic disk is similar to an array disk in that it can support RAID functions. You can convert a basic disk to dynamic in order to apply RAID functions to the disk.

When you install the Windows operating system, your disks are automatically initialized as basic. You can upgrade them to dynamic after the Array Manager installation is complete. See "Upgrading a Basic Disk to Dynamic" for more information.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Basic Disk Definition

A basic disk adheres to the partition-oriented scheme of a Windows operating system. A basic disk can have up to either four primary partitions or three primary partitions plus an extended partition. This extended partition can be subdivided into a number of logical drives.

You can create only primary and extended partitions on basic disks. You should create partitions on basic disks if you want computers running Microsoft Windows 98 or earlier, or MS-DOS to access these partitions.

Dynamic Disk Definition

Dynamic disks are created by upgrading basic disks using Array Manager. A dynamic disk is a physical disk that can contain dynamic volumes created with Array Manager. A dynamic volume organizes space on one or more physical disks by using a specific type of volume layout. The five types of dynamic volumes are simple, spanned, mirrored, striped, and RAID-5.

On a dynamic disk, space is organized through volumes rather than partitions. Because a dynamic disk does not have the partitioning scheme used by Windows 95/98 and MS-DOS, you cannot access dynamic disks through those operating systems.

For more information on the dynamic volume types, see the "Dynamic Volume Types" in the "Volumes" chapter.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.


Working with Basic Disks

This section's topics are:

Basic Disk Functions

Array Manager allows you to do the following on basic disks:

Basic Disk Limitations

You cannot perform the following tasks on a basic disk:

Create Primary and Extended Partitions

Use the Create Volume wizard to create primary partitions and extended partitions on a basic disk.

  1. From the Task menu, select Create Volume. You can also select a basic disk, right-click to display the context menu, and select Create Volume. Both methods display the Create Volume wizard window.

  2. The Create Volume wizard's first page displays information about volumes. Read the information and then click Next to continue.

  3. You are asked to select whether to create a partition or a volume. If you have started with a basic disk, the Partition radio button is already selected. The group that the partition will be created in is displayed. Click Next to continue.

Select Partition Type
  1. The Create Volume wizard asks you to select a partition type (primary or extended) and the size of the partition. Click Next to continue.

Note If the disk already has either four primary partitions or three primary partitions and one extended partition, Array Manager displays a message that you have exceeded the number of partitions and will not let you create any more. Click OK and return to the Array Manager console.
Select Disks and Region
  1. Select a disk and free space on which to create the partition. The dialog box shows a list of available disks and free spaces. Check the box for the disk and free space you want to use, and click to Next continue.

  2. If there is no free space on the selected disk, the free space selection is shaded. A message appears on the wizard that indicates a lack of available disk space. Click Next to continue.

Assign a Drive Letter or Drive Path
  1. Assign a drive letter to this volume if you want to format the partition. (Or you can assign a drive letter afterward.) If you are using a Windows 2000 machine, you can also mount the partition at an empty NTFS folder. Click Next to continue.

Format
  1. Select the Format this volume check box if you want to format the partition. Array Manager allows you to format using either FAT or NTFS. In addition, for Windows 2000 only, you can use FAT32.

  2. To name the partition, type a name in Volume Label. If you do not enter a name, your partition will be named "New Volume" by default.

  3. Select an allocation unit size, if you choose to use a size other than the default. Default settings are strongly recommended for general use.

  4. If desired, select a formatting option:

  5. Click Next to continue, then Finish.

Create Logical Drives in an Extended Partition

An extended partition can be subdivided into as many as 32 logical drives. You can use all or part of the free space in an extended partition when creating logical drives. An extended partition or a logical drive cannot span multiple disks.

  1. Select an extended partition from the left panel tree view.

  2. Click Create Logical Drive to display the Create Volume wizard. Click Next to move through the wizard's Select Partition or Volume window. (Partition is selected by default.)

Select Partition Type
  1. At the Select Partition Type window, the Logical Drive button is automatically selected, and displays the largest logical drive size that can be created on that drive.

  2. Type the size of the logical drive that you want to create, and then click OK.

Select Disks and Region
  1. Select the disk and free space for the partition.

Assign Drive Letter
  1. Choose a drive letter if you want to name and format the logical drive. If you do not choose a drive letter, the logical drive cannot be formatted. (A drive letter can be assigned later.)

  2. Click Next to continue, then Finish.

The Status column in list view displays Formatting and displays the percentage of completion of the format process. The logical drive status changes to Healthy when formatting is complete, and the logical drive becomes available for use.

Dealing with Removable Media

In the graphical view, removable-media devices are labeled Removable. They are considered basic disks.

You can create only one primary partition on removable-media devices. You cannot create extended partitions, logical drives, or dynamic volumes on removable-media devices. You cannot upgrade removable-media devices to dynamic volumes. Removable-media devices can contain only one primary partition and can be formatted with FAT or NTFS. You cannot mark a primary partition on a removable-media device as active.

Upgrading a Basic Disk to Dynamic

On Windows Server 2003 you need to use the native Disk Management utility (not Array Manager) to upgrade a basic disk to dynamic. For information on accessing the native Disk Management on Windows Server 2003, see "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux."

On Windows 2000, Array Manager can upgrade a basic disk that contains partitions, logical drives, or Disk Administrator volumes. Array Manager converts the partitions and logical drives to simple dynamic volumes and the Disk Administrator volumes to dynamic volumes of the appropriate corresponding RAID type. This capability is called encapsulation and is described in more detail in "Upgrade Disks with Legacy Volumes to Dynamic on Windows 2000" in the next chapter, "Volumes."

When Array Manager creates a partition on a basic disk, Array Manager checks whether the partition is the last one on the disk, and then reserves 1MB at the end of the disk for future upgrade needs. When you upgrade from basic to dynamic, the partition needs to align with the cylinder boundary, which may result in a cylinder size (usually 7.8MB) that is left on the disk. This cylinder size is displayed as unallocated disk space.

Warning! After you upgrade a basic disk to a dynamic disk, you will not be able to revert back to a basic disk until you first delete all the dynamic volumes on the disk. Then you can use the Revert to Basic Disk command to revert the disk back to a basic disk. Make sure to back up your data in this scenario before deleting any volumes, or your data will be lost!

Note There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.
To Upgrade a Basic Disk to a Dynamic Disk
  1. Right-click the disk you wish to upgrade and select Upgrade Dynamic Disk from the context menu that appears.

  2. The Upgrade Disk wizard explains information about upgrading. Click Next to continue.

  3. You are asked to select disks to upgrade. Add the basic disks you want to upgrade to the list of dynamic disks and click Next to continue, then Finish.


Working with Dynamic Disks

This section's topics are:

Dynamic Disk Advantages

When you upgrade a dynamic disk, Array Manager writes a small database onto the upgraded disk to store volume management information about the disk and all other dynamic disks present on your system. This database is what gives a dynamic disk many advantages:

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.


Dynamic Disk Limitations

Although Windows 2000 can access dynamic disks created with Array Manager, the dynamic volumes on these dynamic disks cannot be changed without Array Manager.

Virtual disks of Fibre Channel storage in a Storage Area Network (SAN) can be converted to dynamic disks, but this should be done with the following considerations:

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Creating Volumes on a Dynamic Disk

You can create dynamic volumes on dynamic disks only. To create and delete simple, spanned, striped, mirrored, and RAID-5 volumes, see "Creating a Dynamic Volume" in the "Volumes" chapter.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Extending a Simple or Spanned Volume on a Dynamic Disk

You can extend simple and spanned volumes without having to locate unallocated contiguous space on the disk. See "Extending a Dynamic Simple or Spanned Volume" in the "Volumes" chapter.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Reactivating Dynamic Disks

A dynamic disk may appear as a missing disk when it is corrupted, powered down, or disconnected. You can reactivate a dynamic disk to bring it back online.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

To Reactivate a Missing or Offline Disk
  1. Right-click the disk marked Missing or Offline dynamic disk.

  2. Select Reactivate Disk from the context menu. The disk should be marked Online after the disk is reactivated.

Merging a Foreign Disk

Dynamic disks with a Foreign status are disks that have been moved from another computer. You cannot reactivate a foreign disk. To change a foreign disk's status and enable it to be seen as a part of the current computer system, you will need to use the command Merge Foreign Disk. For details on how this command is done, see the next topic "Moving a Dynamic Disk to Another Computer."

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.

Moving a Dynamic Disk to Another Computer

Before you disconnect the disks, make sure the status of the volumes on the disks is Healthy. If the status is not Healthy, you should repair the volumes before you move the disks. You need to prepare disks for removal in some cases. See "Prepare to Remove." It is also recommended that you back up all data on your volumes before you move disks to another computer.

Note The ability to move dynamic disks to another computer is not supported with SAN storage. Only basic disks can be moved between servers on a SAN. Refer to the Dell OpenManage™ Storage Consolidation software documentation for more information. In addition, dynamic disks and dynamic volumes are only supported on the Windows 2000 operating system.
To Move a Dynamic Disk to Another Computer
  1. Turn the computer off, remove the physical disks, and then install the physical disks on the other computer. Restart the computer.

  2. Open Array Manager.

  3. In most cases, the disks are merged automatically. However, if the disks appear in the disk list and graphical views as Foreign, right-click a new disk, click Merge Foreign Disks, and then follow the instructions on your screen.

Notes

Reverting a Dynamic Disk to Basic

You can revert a dynamic disk to basic if there are no volumes on the disk. If volumes exist, you must delete them before you can revert the disk. Disks shown in Array Manager to be unreadable or to be Foreign disks can be reverted, but doing so causes you to lose all existing data on the reverted disk.

There are particular considerations regarding dynamic disks and volumes on NetWare, Windows Server 2003, and Linux. See "Dynamic Disk and Volume Support on NetWare, Windows Server 2003, and Linux" for more information.


General Disk Functions

This section on general disk functions has the following topics:

Note For disk troubleshooting information, see "Disk Troubleshooting Procedures."

Add a New Disk to Your System

Use this procedure to add a new disk to your system and make the disk visible to Array Manager.

Note If the disk you are adding already contains data, you must format the disk using the controller BIOS before the disk can be used by Array Manager. Until you format the disk using the controller BIOS, the disk will have an Offline or Foreign status and may generate other errors.
  1. Install or attach the new physical disk (or disks).

  2. Click View, and then click Rescan, or select Rescan from the toolbar.

Array Manager should detect the new disk after you click Rescan. However, if Array Manager does not detect the new disk, you may need to restart your computer.

New disks are added to the computer as basic disks. On Windows 2000, you can update basic disks that contain data to dynamic. See the section "Upgrade Disks with Legacy Volumes to Dynamic on Windows 2000" in the "Volumes" chapter.

Related Information

Replacing a Disk Receiving SMART Alerts

SMART alerts are event messages predicting that a disk may fail in the near future. If an array disk is receiving SMART alerts, you should replace the disk. Use the following procedures to replace a disk receiving SMART alerts.

If the disk is part of a redundant virtual disk:

  1. Right-click the disk that is receiving SMART alerts and select Offline from the pop-up menu in the Array Manager tree view. See "Offline Array Disk" for more information on the Offline command.

  2. Manually remove the disk.

  3. Insert a new disk. Make sure that the new disk is the same size or larger as the disk you are replacing. (On some controllers, you may not be able to use the additional disk space if you insert a larger disk. See "Virtual Disk Considerations for PERC Subsystem 1 Controllers" for more information.) After you complete this procedure, a rebuild is automatically initiated because the virtual disk is redundant.

If the disk is not part of a redundant virtual disk:

  1. Back up data from the virtual disk.

  2. Delete the virtual disk.

  3. Replace the disk that is receiving SMART alerts.

  4. Create a new virtual disk. Make sure that the new virtual disk is the same size or larger than the original virtual disk. For controller-specific information on creating virtual disks, see "Virtual Disk Considerations for PERC Subsystem 1 Controllers" and "Virtual Disk Considerations for PERC Subsystem 2 Controllers."

  5. Restore the backed up data from the original virtual disk onto the newly created virtual disk.

Update Disk Information Using Rescan

When Array Manager rescans disks, it scans all attached disks for disk configuration changes. It also updates information on removable media, CD-ROM drives, basic volumes, file systems, and drive letters.

Every time you remove or add disks to a computer, you must click Rescan and then verify that the disk information is correct.

To Rescan Disks

From the View pull-down menu, select Rescan, or select the Rescan icon from the toolbar.

A rescan can take several minutes, depending on the number of devices installed.

Refresh the Array Manager Console Display

Use this option to refresh drive letter, file system, volume, and removable-media information. Refresh also checks to see whether unreadable volumes are now readable. However, it does not scan hardware. To update hardware information, use Rescan instead.

  1. From the View pull-down menu, select Refresh, or select Refresh from the toolbar. The General tab view displays a percentage status line under the Progress column in the right pane.

  2. After the operation is finished, the Array Manager console displays current information.

Write a Disk Signature

Windows requires that a disk have a signature on it before it can be used. Most controllers require that the write signature be added manually.

When you create a virtual disk and then do a rescan, the newly created virtual disk appears under the Disks storage object. If the disk needs a signature to be written manually, its icon will display an error symbol. Also, its type will be listed as "No Disk Signature" in the disks displayed in the right pane of the console. If left unsigned, the disk cannot be used.

Use the following steps to write a disk signature. This procedure assumes that you have already created the virtual disk.

  1. Expand the Disks object in the Array Manager tree view.

  2. Right-click a virtual disk that needs a write signature to display the Write Disk Signature dialog. This dialog displays all virtual disks that require a disk signature.

  3. Select the virtual disks for which you wish to do a write signature. You can do a write signature on more than one virtual disk at the same time.

  4. Click Ok.

Once a signature is written on a disk, the disk is displayed as a basic disk. You can create partitions on the basic disk, or you can upgrade the disk to dynamic to create volumes on it.

Monitoring Disk Reliability

Array Manager supports Self Monitoring Analysis and Reporting Technology (S.M.A.R.T.) on array disks that are S.M.A.R.T. enabled.

S.M.A.R.T. performs predictive failure analysis on each disk and sends alerts if a disk failure is predicted. The RAID controllers check array disks for failure predictions and, if found, pass this information to the Array Manager console. Array Manager immediately displays an alert icon on the disk. Array Manager also raises an alert under the Events tab and in the Windows Event Log.

Note When a controller's I/O is paused, you will not receive S.M.A.R.T. events.

Array and Hard Disk Menu Commands

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, 4/IM, PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, CERC SATA1.5/2s, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

This section describes the following commands for working with array disks:

Initialize Array Disks

This section applies to PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers.

The Initialize command prepares an array disk for use as a member of a virtual disk. For details, see the "Initialize Array Disks."

Caution This is a data-destructive command. Any virtual disks residing on this array disk will be removed.

Rebuild

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers.

The Rebuild function is enabled only when a disk has failed. You can rebuild failed disks only in redundant arrays.

To Rebuild a Failed Disk
  1. Right-click the failed disk that you want to rebuild.

  2. Click Rebuild. In the right pane, the status of the disk is Rebuilding and a progress bar shows the percentage of completion.

Note For information on performing a rebuild on the CERC SATA1.5/2s controller, see Rebuild (CERC SATA1.5/2s Controller).

Assign Global Hot Spare

This section applies to 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 2, 2/Si, 3/Si, 3/Di, and CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers

A global hot spare is an unused backup disk that is part of the array group. Hot spares remain in standby mode. When an array disk that is used in a virtual disk fails, the assigned hot spare is activated to replace the failed array disk without interrupting the system or requiring your intervention. When a hot spare is activated, it rebuilds the data for all redundant virtual disks that were using the failed array disk.

You can change the hot spare disk assignment by unassigning a disk and choosing another disk to assign, as needed.

For more information on hot spares, see "Understanding Hot Spares."

Note Global hot spares must be assigned and unassigned manually. They are not assigned to specific virtual disks. On PERC Subsystem 1 controllers, there are size requirements for the hot spare. See "Considerations for Hot Spares (PERC Subsystem 1)" for more information. If you want to assign a hot spare to a virtual disk (it will replace any array disk that fails in the virtual disk) then use the "Configure Dedicated Hot Spare" command. For more information on hot spares, see "Understanding Hot Spares."
To Assign a Global Hot Spare
  1. Right-click the array disk that you wish to use as a hot spare.

  2. Click Assign Global Hot Spare.

  3. To confirm the successful completion of the operation, check the properties displayed in the right pane. The status of the array disk must be Ready and type must be Spare Array Disk.

Unassign Global Hot Spare

This section applies to 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 2, 2/Si, 3/Si, 3/Di, and CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers

Use this operation to unassign the global hot spare disk.

To Unassign a Global Hot Spare
  1. Right-click the disk that is assigned as a hot spare.

  2. Click Unassign Global Hot Spare.

  3. To confirm the successful completion of the operation, check the properties displayed in the right pane. The status of the array disk must be Ready and type must be Array Disk.

Online Array Disk

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers.

You can set to Online only an array disk that is part of a redundant virtual disk that has been set to Offline.

To Online an Array Disk
  1. Right-click the disk that you want to set to Online.

  2. Click Online. In the right pane, the status of the disk is changed from Offline to Online.

Offline Array Disk

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers.

You can set to Offline only an array disk that is part of a redundant virtual disk that has been set to Online.

To Offline an Array Disk
  1. Right-click the disk that you want to set to Offline.

  2. Click Offline. A confirmation dialog box appears.

  3. Click OK to continue. In the right pane, the status of the disk will be changed from Online to Failed.

Prepare to Remove

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers.

Before you remove any physical disk from an enclosure, it is recommended that you perform this operation to prevent data loss.

Note This procedure is not supported on the CERC ATA100/4ch, CERC SATA1.5/6ch, or CERC SATA1.5/2s controllers. In addition, this procedure is only supported for hotswap array disks (disks that reside in a carrier).
To Prepare to Remove an Array Disk
  1. Right-click the disk that you want to remove.

  2. Click Prepare to Remove, then click Yes to continue.

  3. You can remove the disk under either of the following conditions:

Note On PERC 2, 2/Si, 3/Si, and 3/Di controllers, this procedure is only supported for hotswap array disks (disks that reside in a carrier). In addition, you may need to perform a rescan for the new disk to be displayed in the Array Manager tree view.

Blink

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

The Blink command allows you to find an array disk within an enclosure by blinking one of the light-emitting diodes (LEDs) on the disk. The LEDs could blink from 30 seconds to indefinitely. You may want to use this command to locate an array disk that has failed.

To blink an array or hard disk:

  1. Right-click the disk object in the tree view.

  2. Select Blink from the pop-up menu.

Note This procedure is not supported on the CERC ATA100/4ch, CERC SATA1.5/6ch, or CERC SATA1.5/2s controllers. In addition, this procedure is only supported for hotswap array disks (disks that reside in a carrier).
Note When using an Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, or LSI 1030 controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.

Unblink

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 2, 2/Si, 3/Si, 3/Di, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

The Unblink command allows you to cancel the Blink command.

To unblink an array or hard disk:

  1. Right-click the disk object in the tree view.

  2. Select Unblink from the pop-up menu.

Note This procedure is not supported on the CERC ATA100/4ch, CERC SATA1.5/6ch, or CERC SATA1.5/2s controllers. In addition, this procedure is only supported for hotswap array disks (disks that reside in a carrier).
Note When using an Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, or LSI 1030 controller, the Blink and Unblink commands apply to hard disks contained in carriers that can be inserted into a server or an enclosure. If the hard disk is not contained in a carrier but is instead designed to be connected with a SCSI cable (typically a ribbon cable), then the Blink and Unblink commands are disabled.

Remove Orphan/Dead Disk Segments

This section applies to PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers.

This command removes the disk space occupied by an orphan or dead disk segment.

A segment may be designated as dead if it is logically bad, is physically damaged, or resides on a disk that has been disconnected from and then reconnected to the controller.

Array and Hard Disk Properties

This section applies to PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, CERC ATA100/4ch, 4/IM, PERC 2, 2/Si, 3/Si, 3/Di, CERC SATA1.5/6ch, CERC SATA1.5/2s, Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020, and LSI 1030 controllers.

Use this command to display the array or hard disk properties. Array disks are attached to RAID controllers (PERC Subsystem 1 and 2) and hard disks are attached to non-RAID SCSI controllers (SCSI Subsystem). The PERC 3/Di and PERC 4/Di controllers, however, can run in RAID/SCSI mode; these controllers handle one channel in RAID mode and the other channel in non-RAID SCSI mode.

To display the disk properties:

  1. Right-click the disk object in the Array Manager tree view.

  2. Select Properties from the pop-up menu. This action displays the Array Disk Properties dialog which displays the disk properties.

Disk properties may include:

Note If you have PERC Subsystem 1 and PERC Subsystem 2 RAID controllers, the Unallocated Space field displays the available space. If you have SCSI (non-RAID) controllers, the field displays "N/A" (Not Applicable). If a controller is running in RAID/SCSI mode, the disks attached to the SCSI channel are displayed as "Hard Disk 0:1" instead of "Array Disk 0:1". Because the disks attached to the SCSI channel are not used to build virtual disks, they will also display "N/A" in the Unallocated Space field, just like the disks on non-RAID controllers.
Note Negotiated and capable speeds are not displayed for PERC 2/SC, PERC 2/DC, CERC ATA100/4ch, CERC SATA1.5/6ch, CERC SATA1.5/2s, Ultra SCSI, or Ultra2 SCSI. New SCSI drives manufactured since the introduction of the Ultra 320 SCSI drives will display this negotiated and capable speed information from Array Manager if your controller supports reporting them. If the drive was manufactured before that time, the negotiated and capable speed fields might display "not available".
Note Array disks for the PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers display Ready status if they are not part of a virtual disk and Online status if they are part of a virtual disk.
Note Array disks for the PERC 2, PERC 2/Si, PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers display Ready status regardless of whether they are a part of a virtual disk or not. Ready status for these controllers means the disk is operational.


Back to Contents Page