Use the Elements window to view information about your system's installed power supplies. Use the Alert Actions window to configure alert actions for Power Supply and Power Redundancy Alerts.
| System Tree Selection | Tab | Subtab | User Privileges | |
| View | Manage | |||
| Main System Chassis | ||||
| Power Supplies | Properties | Elements | U, P, A | NA |
U=User; P=Power User; A=Administrator; NA=Not Applicable. For more details on user privilege levels, see "Privilege Levels in the Server Administrator GUI."
The power supply is an electrical system that converts AC current from the wall outlet into the DC currents required by the system components.
| Redundancy Status | Status can be Full, Degraded, or Lost. Full redundancy requires that the number of power supplies required for operation be working +1. Degraded redundancy means that one or more of the extra power supplies is not working in the normal range. Lost redundancy means that there are no backup power supplies available to take over for the minimum number required. |
| Number of power supplies required for full redundancy | Your system has a number of power supplies defined for full redundancy. If the number of power supplies required for Full redundancy is two, redundancy is lost when only one power supply is working. |
| Status | Name of the port, such as serial or parallel, USB, mouse, keyboard, and so on. |
| Location | Place in the system where the power supply is installed. |
| Type | Whether the power that is supplied to the system is AC or DC. |
| Max Wattage | Maximum wattage that the power supply can deliver. |
| Online Status | Whether the power supply is currently delivering power to the system (online) or whether the power supply is not supplying power (offline). |
Use this window to configure the alerts that you want to take effect in case of a power supply warning, failure, or loss of redundancy event.
| System Tree Selection | Tab | Subtab | User Privileges | |
| View | Manage | |||
| Main System Chassis | ||||
| Power Supplies | Alert Management | Alert Actions | U, P, A | P, A |
U=User; P=Power User; A=Administrator; NA=Not Applicable. For more details on user privilege levels, see "Privilege Levels in the Server Administrator GUI."
| Event | Description |
| Power Supply Critical | Power supply is operating outside of wattage limits. Take power supply offline. |
| Power System Redundancy Degraded | The number of operational supplies has fallen below the number required for Full redundancy. |
| Power System Redundancy Lost | The number of operational power supplies has fallen below the number required for partial redundancy (redundancy Degraded). Only the minimum number of power supplies required by the system is operational. In the event that the nonredundant power supplies fail, there will be no power delivered to the system. |
To configure alert actions for power supplies, see "Power Supply Alert Actions."