| System Tree Selection | Tab | Subtab | User Privileges | |
| View | Manage | |||
| Main System Chassis | ||||
| Fans | Properties | Fan Probes | U, P, A | P, A |
| Fan Control | U, P, A | P, A | ||
| Alert Management | Alert Actions | U, P, A | P, A | |
| SNMP Traps | U, P, A | P, A | ||
U=User; P=Power User; A=Administrator; NA=Not Applicable. For more details on user privilege levels, see "Privilege Levels in the Server Administrator GUI."
The operation of various system components generates heat. Maintaining an appropriate operating temperature inside the system chassis is therefore critical. Fans are one component that help with temperature control.
Some fan probes monitor fan status by measuring fan RPMs. Other fan probes report an ON or OFF status for a particular fan. Fan probes report the RPMs or ON/OFF status to the Server Administrator instrumentation service. When you select Fans from the device tree, details appear in the data area on the right-hand side of the Server Administrator window.
Critical components have an event type associated with them at all times. Status is a shorthand term for the component's event type. Status can be given for a component's operational state as well as for its redundancy state, if applicable. See "Event Type Definitions and Component Health" for more information on status and related concepts.
Some fan probes monitor fan status by measuring fan RPMs. Other fan probes report an ON or OFF status for a particular fan. When you select Fans from the device tree, details appear in the data area in the right-hand side of the Server Administrator window. Fan status is one of the following three states:
| Normal | |
| Warning | |
| Failure |
| Status | Displays whether the event type for the probe is Normal, Warning, or Failure. |
| Probe Name | The alphanumeric text that uniquely identifies a fan probe; for example, CPU Fan. |
| Reading | Snapshot of RPMs actually measured by the probe at a given time. |
| Minimum Warning Threshold | The lowest acceptable fan RPM that is recommended for system operation. Values that fall below this RPM level result in warning events. |
| Maximum Warning Threshold | The highest acceptable fan RPM that is recommended for system operation. Values that exceed this fan RPM result in warning events. |
| Minimum Failure Threshold | The lowest acceptable fan RPM that is required for system operation. Values that fall below this fan RPM result in failure events. |
| Maximum Failure Threshold | The highest acceptable fan RPM that is required for system operation. Values that exceed this fan RPM result in failure events. |
For information on how to set warning thresholds for fan probes, see "Edit Fan Probes."
For information on how to set alert actions for fan probes, see "Set Alert Actions."