Dell OpenManage Array Manager 3.3
This tutorial chapter illustrates how two components of the Array Manager application, hardware RAID and software RAID, function together. You should read this chapter and follow all the steps if you are a new user or if you are getting reacquainted with the application.
In this chapter, you will learn how to do the following:
![]() |
Note For this tutorial, you should have four unused array disks under Array Group 0 (connected through a controller card) and Array Manager software installed on your system. It is recommended that your disks all be the same size. |
To complete this tutorial, it is assumed that you are familiar with array disks and RAID concepts. Refer to the following sections or chapters for detailed information:
Hardware RAID Functional Block Diagram
RAID functions can be implemented with either hardware RAID (through a RAID controller) or software RAID (RAID programming without specific hardware).
In this tutorial, you will use hardware RAID to create two RAID-0 virtual disks. Each virtual disk will contain two array disks. Once the virtual disks are created, they are displayed as disks in the Windows NT® or Windows® 2000 operating system.
Software RAID can be configured on top of the hardware RAID volumes and provide a powerful variety of features. In this tutorial, you will upgrade the two virtual disks, which are classified as basic disks, to dynamic disks. Then you will use Array Manager's software RAID functions to create a dynamic mirrored volume, as shown in the illustration above. The mirrored volume provides redundancy to your configuration.
Disk 0 in the above illustration refers to the computer's boot disk.
This tutorial may take from 10 to 20 minutes to complete. It has five sections:
To get started with the tutorial, do the following:
![]() |
Note The screens for this tutorial represent a server that has a storage subsystem with a PERC controller. If you have a different controller, the arrangement of storage objects in the GUI may vary slightly. |
Locating the Array Group in the Left and Right Panes
The Select Creation Mode Wizard
The Select Virtual Disk Type window appears.
The Select Virtual Disk Type Window
You are asked for the following information:
The Default Disk Selection Window
If you chose Custom Mode, follow the instructions on the wizard to continue.
When initialization is complete, "Ready" appears under the Status column.
The new virtual disk appears in the General tab view similar to the example screen that follows. In the screen, Virtual Disk 0 is the boot disk and was already created. Virtual Disk 1 is the newly created disk.
Viewing the New Virtual Disk in the General Tab View
If your configuration is similar to the one shown in the screen above, Virtual Disk 1 appears under Array Group 0 in the tree view in the left pane of the console window. If you click the plus sign (+), you will see Array Disk 0:1 and Array Disk 0:2, indicating that the virtual disk was created from these two array disks, as shown in the sample screen that follows.
Viewing the New Virtual Disk in the Tree View
Repeat steps 1 - 10 described in the preceding section to create a second striped virtual disk. Give it the default name of "Virtual Disk," select RAID-0, and make the disk the same size as the first virtual disk.
If the newly created virtual disks do not appear under the Disks object, then perform a rescan by selecting Rescan from the View pull-down menu. Rescan forces the Array Manager software to locate and query all the objects in the system. This can take several minutes if there are numerous disks in the system.
In the left pane, you will see the two new virtual disks under the Array Group 0 object. Under the Disks object, you will see two new disks. In the sample screen that follows, each disk displays an error symbol because it does not yet have a disk signature on it. Most controllers require that the disk signature be added manually. The PERC 2, PERC 2/Si, PERC 3/Si, and PERC 3/Di controllers on Windows NT are the exceptions.
In the sample screen that follows, notice that the top-level computer system also displays the error symbol. Whenever there is an error on a subordinate storage object, the top-level object in the tree view displays an error symbol. Because the tree view can be collapsed down to display only the top-level system, it is important that this object display the error condition so that you can be aware that an error exists even when the tree is fully collapsed.
When you have a virtual disk that requires a disk signature, you will see that fact noted in the disk listing of the General tab of the Array Manager console, as shown in the sample screen that follows.
New Virtual Disk Without Signature
Displaying the Virtual Disk Type
This section explains how to upgrade a newly created virtual disk to a dynamic disk.
![]() |
Note On Windows NT, the disk must not contain partitions or volumes. It should be an empty disk. On Windows 2000, the disk can contain partitions and/or basic volumes. |
The Upgrade Disk Wizard, Continued
In the left pane, you will see the two virtual disks under Array Group 0. Under the Disks object, you will see two disks, which have been upgraded to dynamic disks.
This is the final step in the process of creating a mirrored volume on the striped virtual disk. You will use the Create Volume wizard in this process.
Right-click the icon of one of the upgraded disks and select Create Volume.
The Select Partition or Volume Window
Concatenated will be chosen by default. Since you are creating a mirrored volume, click the Mirrored check box to request a mirrored volume. Click Next.
![]() |
Note The sample screen shown below was taken on a Windows NT system, and thus it does not show the Query Max Size button that is available on Windows 2000 systems. For more information on this button, see Creating a Dynamic Volume in the Volume Management chapter. |
![]() |
Note The sample screen above was taken on a Windows NT system, and thus it does not show the additional option of mounting a drive at an empty NTFS folder that is available on Windows 2000 systems. |
![]() |
Note It is strongly recommended that you leave the allocation unit size as Default. Selecting any other value requires an advanced knowledge of Windows file systems. You should thoroughly review the Microsoft Windows documentation before selecting any value other than Default. |
Enabling File and Folder Compression
You now have a striped (hardware RAID) and a mirrored (software RAID) volume that you created from your hardware array disks. Click Volume 1 in the left pane, and the statistics appear in the right pane.