Push Install Instructions for Windows Server 2003 - Introduction - Setting up an Install Directory on the File Server - Deployment Methods - Microsoft Documentation for Unattended Installations of Windows Server 2003 - Sample unattend.txt File for Windows Server 2003 - Directory Structure for Unattended Installation Files ---------------------------------------------------------------------------- Introduction A "Push", or unattended installation of Windows Server 2003 provides a means for network administrators to easily install Windows Server 2003 on similarly equipped systems. The network administrator can create a bootable diskette that will automatically log into a central server and install the operating system from an image of the Windows Server 2003 installation directory stored on that server. This document provides instructions for a basic unattended installation of Windows Server 2003 (32-bit version) that includes the installation of drivers for the Intel(R) PRO/100 and Intel PRO/1000 adapters. The elements necessary for the Windows Server 2003 unattended installation are: - A Windows Server 2003 system with a shared image of the Windows Server 2003 Installation CD. - An unattended installation configuration file that provides Windows Server 2003 setup with information it needs to complete the installation. The name of this file is UNATTEND.TXT. - A DOS boot diskette that contains Microsoft Network Client software for connecting to the Windows Server 2003 system and AutoExec commands to automatically start the Windows Server 2003 installation. -------------------------------------------------------------------------------- Setting up an Install Directory on the File Server The server must be setup with a distribution folder that holds the required Windows Server 2003 files and which clients can reach when connecting via TCP/IP or IPX. For illustration purposes, the examples in this readme use the network share D:\PUSHWS03. To create this share: 1) Create a directory on the server, (EX: D:\PUSHWS03). 2) Use the My Computer applet in Windows Server 2003 to locate the D:\PUSHws03 folder. 3) Right-click the folder and select Sharing. 4) Select Share this folder, then give it a share name (EX: PUSHWS03). This share name will be used to connect to this directory from the remote target systems. By default, the permissions for this share is for Everyone to have Full Control. 5) Adjust permissions as necessary and click OK. To prepare the distribution folder: 1) Copy the entire contents of the Windows Server 2003 CD to D:\PUSHWS03. 2) Use Windows Explorer or XCOPY to maintain the same directory structure as on the Windows Server 2003 CD. When the copy is complete, the Windows Server 2003 installation files should be in the D:\PUSHWS03 directory and the I386 and other installation directories should be subdirectories of the D:\PUSHWS03 directory. 3) Copy Unattend.txt from the Intel CD (found in APPS\SETUP\PUSH\WS03XP32) into the shared directory D:\PUSHWS03\I386. 4) Edit the Unattend.txt file with Notepad or another text-editor to include your customizations. At a minimum you should change the items in the [UserData] section of the file. For Server Installations the [LicenseFilePrintData] section should be edited to specify the License type, and the number of users if the license type is PerServer. 5) Create the driver install directory structure and copy the driver files to it. NOTE: The PUSHCOPY.BAT file provided with the drivers in the \APPS\SETUP\PUSH directory copies the appropriate files for the installation. PUSHCOPY also copies the components needed to perform the automated installations contained in the [GuiRunOnce] section of the sample UNATTEND.TXT file. These include an unattended installation of the Intel PROSet configuration and diagnostic utility. Example: From a Windows Server 2003 command prompt where e: is the drive letter of your CD-ROM drive: e: cd \APPS\SETUP\PUSH (you must be in the \APPS\SETUP\PUSH directory to run PUSHCOPY) pushcopy D:\PUSHWS03\I386 WS03 The above command creates the $OEM$ directory structure and copies all the necessary files to install the driver and Intel PROSet. However, Intel PROSet is not installed unless the line: ; Command0="c:\drivers\net\Intel\Proset.msi /qn" is uncommented from unattend.txt. See the "Directory Structure for Unattended Installation Files" section of this document for more information about the directory structure and file layout of the $OEM$ directory. ---------------------------------------------------------------------------- Deployment Methods Make sure that you have a copy of a network bootable MS-DOS* floppy that connects to the Z:\PUSHWS03 directory. Use it to boot the destination system (the one you want to push install to) and connect to this shared network directory. Run this command at the \\Server\PUSHWS03\i386) prompt: winnt /u:Z:\I386\unattend.txt /s:Z:\I386 /t:c where Z: equals mapped drive NOTE: In the above procedure, setup runs the installation in unattended mode and also detects the plug and play network adapters. All driver files are copied from the shared directory to the target system directories and installation of the OS and Network Adapters continues without user intervention. ---------------------------------------------------------------------------- Microsoft Documentation for Unattended Installations of Windows Server 2003 For a complete description of the parameters supported in Unattend.txt see the DEPLOY.CHM document in the DEPLOY.CAB cabinet file on the Windows Server 2003 CD. To obtain the document, use Internet Explorer 5.0 or greater to open DEPLOY.CAB in the \SUPPORT\TOOLS directory on the CD. Other documents and utilities in the DEPLOY.CAB file provide details and tools for setting up a variety of unattended installation methods. -------------------------------------------------------------------------------- Sample Unattend.txt file for Windows Server 2003 [Unattended] UnattendMode=FullUnattended OemSkipEula=Yes OemPreinstall=Yes OemPnPDriversPath=\drivers\net\INTEL TargetPath= * DriverSigningPolicy=Ignore Filesystem=LeaveAlone OverwriteOemFilesOnUpgrade=No ; This switch prevents the user setup dialog from running when ; Windows Server 2003 starts for the first time. UnattendSwitch=Yes [GuiUnattended] AdminPassword=* AutoLogon=Yes AutoLogonCount=1 OEMSkipRegional=1 TimeZone=4 OemSkipWelcome=1 [UserData] FullName=Name OrgName=Organization ComputerName=Computer1 ; PRODUCT ID is required for most installations. ProductID="xxxxx-xxxxx-xxxxx-xxxxx-xxxxx" [GuiRunOnce] ; *** command to install PROSet - uncomment to install PROSet after push ; install ; Command0="c:\drivers\net\INTEL\Proset.msi /qn" [Identification] JoinWorkgroup=WORKGROUP ; *Use the following for a domain installation ; JoinDomain=MYDOMAIN ; CreateComputerAccountInDomain=Yes ; DomainAdmin=Installer ; DomainAdminPassword=install [Networking] InstallDefaultComponents=Yes ---------------------------------------------------------------------------- Directory Structure For Unattended Installation Files The following directory structure is created by PUSHCOPY.BAT to place the files necessary for the installation of the driver and Intel PROSet. The directory D:\PUSHWS03 refers to the location of the files from the Windows Server 2003 installation CD. D:\PUSHWS03\I386\$OEM$\$1\DRIVERS\NET\INTEL (From the PRO100\WS03 directory of the Intel CD) E100B325.INF E100B325.DIN E100B325.SYS E100B325.CAT E100BMSG.DLL INTELNIC.DLL PROUNSTL.EXE (From the PRO1000\WS03 directory of the Intel CD) E1000325.INF E1000325.DIN E1000325.SYS E1000325.CAT E1000MSG.DLL (From the \APPS\PROSET\W2KWS03 directory on the Intel CD) ANSMXP.INF ANSPXP.INF IANSMSG.DLL IANSWXP.SYS IANSWXP.CAT PROSET.EXE PROSET.MSI S8023DEV.REG *.CAB (From the \APPS\SETUP\PUSH\WS03 directory on the Intel CD) UNATTEND.TXT PUSHWS3.TXT ; To activate the Intel PROSet installation once the above directories have ; been created and populated, uncomment the line: ; Command0="c:\drivers\net\INTEL\Proset.msi /qn" ; in the [GuiRunOnce] section of Unattend.txt