Dell(TM) OpenManage(TM) Server Administrator Storage Management
Version 3.0 Readme

######################################################################

This is the readme file for version 3.0 Storage Management. For more
information, see the Dell OpenManage Server Administrator readme file
and the Dell OpenManage Server Administrator User's Guide at the Dell
Support website at "support.dell.com."

Note: The Storage Management is installed using the Dell OpenManage
      Server Administrator installation process.
      See the installation readme (readme_ins.txt) on the "Dell
      Systems Management Tools and Documentation" DVD for the latest
      installation information.

Note: Installing the Storage Management on a system that does
      not have a supported controller or that has a controller that
      is not attached to storage is an unsupported configuration.
      It is recommended to use Dell OpenManage Server Administrator
      Storage Management version 3.0 on controllers that have
      PERC/SAS firmware version 6.1 or later only.

Note: Attempts to install or run Storage Management using an
      unsupported configuration can result in unexpected and
      undesirable system behavior.

Note: Starting with Dell OpenManage version 5.0, Array Manager is no
      longer an installable option. If you have an Array Manager
      installation and need information on how to migrate from Array
      Manager to Storage Management, see the product documentation
      prior to Dell OpenManage Server Administrator Storage
      Management 2.1.


#######################################################################

======================================================================
Criticality
======================================================================

2 - Recommended


Note: Storage Management does not support Novell(R) NetWare(R) or
      fibre channel. Disk and volume management are also not provided
      by the Storage Management Service.

======================================================================
Title and Description
======================================================================

Dell OpenManage Server Administrator Storage Management is a
storage management application for your systems that provides
enhanced features for configuring a system's locally-attached RAID
and non-RAID disk storage. Server Dell OpenManage Administrator
Storage Management enables you to perform controller and enclosure
functions for all supported RAID and non-RAID controllers and
enclosures from a single graphical or command-line interface without
requiring the use of the controller BIOS utilities. The graphical
user interface (GUI) is wizard-driven with features for novice and
advanced users and detailed online help. The command line interface
is fully-featured and scriptable.

Storage Management supports SCSI, SATA, and SAS technologies.

######################################################################
TABLE OF CONTENTS
######################################################################

COMPATIBILITY/RECOMMENDED REQUIREMENTS
WARNINGS
WHAT IS NEW IN THIS RELEASE?
INSTALLING STORAGE MANAGEMENT, VERSION 3.0
KNOWN LIMITATIONS

######################################################################
COMPATIBILITY/RECOMMENDED REQUIREMENTS
######################################################################

The Dell OpenManage Server Administrator Storage Management is
installed using the Dell OpenManage Server Administrator installation
process. For Dell OpenManage Server Administrator installation
requirements, see the following documentation:

* The installation readme (readme_ins.txt) on the
  "Dell Systems Management Tools and Documentation" DVD for the latest
  installation information.

* The "Installing Server Administrator" chapter in the "Dell
  OpenManage Server Administrator User's Guide."

In addition to the Server Administrator installation requirements,
the following requirements apply to the Storage Management.

NOTE: Storage Management may experience instability if these
      requirements are not met.

* Microsoft(R) Windows Server(R) 2003 with Service Pack 1 or later.
  Service Pack 1 is required to support SAS technology.

* Microsoft(R) Windows(R) 2000 32-bit with Service Pack 4 or later.
  Service Pack 4 is required to support SAS technology.

NOTE: Microsoft(R) Windows 2000 64-bit is not supported.

* Red Hat(R) Enterprise Linux(R) 3.x. Update 3 or later is required
  for Storage Management and Update 7 or later is required for
  the Red Hat Network (RHN) service to update your system software
  with the latest update package before deploying your system. Go
  to www.redhat.com to access the RHN service and download updates.

* SUSE(R) Linux Enterprise Server 9 for Intel EM64T with
  Service Pack 3 or later. Service Pack 3 is required to support
  SAS technology.

======================================================================
COMPATIBILITY WITH OTHER RAID STORAGE MANAGEMENT UTILITIES
======================================================================

* PERC Console and FAST Compatibility Issues when Installing Storage
  Management

  Installing Storage Management on a system that has FAST or the
  PERC Console installed is an unsupported configuration. It is
  recommended that you uninstall FAST and the PERC Console before
  installing Storage Management. In particular, you may find that
  Storage Management or the FAST features are disabled at run time
  when using Storage Management on a system that also has FAST
  installed. Storage Management replaces all storage management
  features provided by FAST and the PERC Console. In addition,
  Storage Management has features not provided by FAST and the PERC
  Console.


* Compatibility with Linux Utilities

  Installing Storage Management on a Linux system that has other
  RAID storage management utilities provided by
  vendors is an unsupported configuration. It is recommended that
  you uninstall these utilities before installing Storage
  Management. Storage Management replaces the storage management
  features provided by these utilities. Examples of
  vendor-supplied Linux utilities include:

  - LinFlash
  - DellMgr
  - DellMON
  - LINLib
  - MegaMgr
  - MegaMON

Note: These utilities are only applicable to the following controllers:
      PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM,
      4e/Si, 4e/Di.

      See the WARNINGS section of this readme for additional
      information.

######################################################################
WARNINGS
######################################################################

* As a general rule, you should use only one RAID utility to
  configure and manage storage. Installing the Storage Management
  Service on a system that has native RAID utilities or RAID
  utilities provided by vendors is an unsupported
  configuration.

* Storage Management enables you to perform storage tasks that are
  data-destructive. Storage Management should be used by experienced
  storage administrators who are familiar with their storage
  environment.

######################################################################
WHAT IS NEW IN THIS RELEASE?
######################################################################

This release of Storage Management provides various functional
improvements along with other new features:

* Hot-plug of enclosures on SAS controllers with firmware version 6.1
  or later

* Redundant path view for enclosures in redundant path on supported
  SAS controllers with firmware version 6.1 or later

* Preview of the foreign configuration on supported SAS controllers
  with firmware version 6.1 or later

* Intelligent mirroring on supported SAS controllers with firmware
  version 6.1 or later

* Allow Revertible Hot spare and Replace member on supported SAS
  controllers with firmware version 6.1 or later

* Single option to change multiple controller properties on supported
  SAS controllers with firmware version 6.1 or later

* Availability of command to Discard preserved controller cache on
  supported SAS controllers with firmware version 6.1 or later

* Storage dashboard enhancements

* Improvisation of online help with content search

* Battery learn on supported SAS controllers with firmware version
  6.1 or later

######################################################################
INSTALLING STORAGE MANAGEMENT VERSION 3.0
######################################################################

* See the "Installing Dell OpenManage Server Administrator" chapter
  in the "Dell OpenManage Server Administrator User's Guide."

Note: You cannot reinstall Storage Management on a system that
      already has Storage Management installed. If you need to
      reinstall Storage Management, you must first uninstall
      the existing installation using the  Server Administrator
      uninstallation process.

Note: Installing Storage Management on a system that does not
      have a supported controller or that has a controller that is not
      attached to storage is an unsupported configuration. Attempts
      to install or run Storage Management using an unsupported
      configuration can result in unexpected and undesirable system
      behavior. It is recommended to use Server Administrator Storage
      Management version 3.0 on controllers that have PERC/SAS
      firmware version 6.1 or later only.

######################################################################
KNOWN LIMITATIONS
######################################################################

The following sections describe known problems associated with
Storage Management or the supported controllers.

* When using RAID 10 with Intelligent Mirroring, you will not be
  allowed to proceed if you select physical drives with different
  storage sizes. This feature ensures that storage space is not wasted.

* In some cases, stopping the Data Manager service may display an error
  that the process terminated unexpectedly. However, this will not
  affect the Data Manager service; subsequent sessions of Data Manager
  will work correctly.

* When you click "Back" or select "Return to previous page," you will
  be redirected to the "Storage Dashboard" screen. This happens only
  for multiple levels of navigation.

* Some controller tasks such as, creation of  a Virtual Disk are not
  possible when the controller has the preserved cache. See the
  controller documentation for more details.

* While creating RAID 10 using "Intelligent Mirroring," the selected
  physical disks are grouped under "span0" in the Result table. Note
  that "Span0" is only a representation for grouping the physical
  disks.

* All the virtual disks from the SAS/iR controller will display the
  name "IR Virtual Disk" on the "Preview" Page. On successful import
  of the virtual disk another name will be assigned to these virtual
  disk and not the same name shown on the preview screen.

* Storage Management supports assignment of only one dedicated Hot
  spare for a virtual disk. However, there are some situations where
  more that one Dedicated Hot-Spare may be assigned for a virtual disk.

* Storage Management does not permit connecting the first enclosure in
  redundant path and the attach two other enclosures on the first and
  second connector of the first enclosure respectively All three
  enclosures must be connected in redundant path configuration only.

* An Error message may not display when the "Import Foreign
  Configuration" task is not successful. (158732)

  Issue: The Import Foreign Configuration task can only import
  virtual disks that have consistent data. A virtual disk with
  inconsistent data cannot be imported. However, When importing
  multiple virtual disks in a single operation, the "Import Foreign
  Configuration" task may report successful completion even when
  inconsistent virtual disks are present and have not been imported
  successfully.

  Workaround: If the Import Foreign Configuration task is unable to
  import an inconsistent virtual disk, then the physical disks that
  belong to the virtual disk continue to display a Foreign state
  after the Import Foreign Configuration task completes. In this case,
  repeat the Import Foreign Configuration task until one of the
  following occur:

  -- There are no physical disks in Foreign state after
     the Import Foreign Configuration task completes.

  -- An error stating that the Import Foreign
     Configuration task has not completed successfully is displayed.
     This error indicates that there are no consistent virtual disks
     available to be imported. Therefore, all unimported virtual
     disks are inconsistent and you can either perform a
     Clear Foreign Configuration to remove the virtual disks or
     remove the physical disks from the controller.


* On a SAS 6/iR, using the command line interface (CLI) to clear a
  foreign configuration displays an error message. (154604)

  Issue: When using the following command on a SAS 6/iR controller:

  omconfig storage controller action=clearforeignconfig controller=id

  a "failure" error message may display even though the command has
  completed successfully.

  Workaround: You can verify that the "Clear Foreign Configuration" task
  completed successfully by using the Storage Management graphical
  user interface (GUI):

  1. Expand the SAS 6/iR controller object in the tree view.
  2. Select the Physical Disks object displayed under the SAS 6/iR
     controller object.
  3. View the "Information/Configuration" tab and verify that none of the
     physical disks display a Foreign state.


* Slot ID for a PERC 5/E Adapter may display as "Slot Not Available"
  on the Storage object Information/Configuration tab. (156528)

  Issue: When using a PERC 5/E Adapter on a Windows 2000 system, the
  Slot ID property on the Storage object Information/Configuration
  tab may display as "Slot Not Available".

  Workaround: If "Slot Not Available" is displayed, you may be able to
  identify the slot ID by selecting the
  System-->Main System Chassis -->Slots object in the tree view and
  displaying the Information tab. The Slot ID property on this tab may
  display the correct information.

* Incompatible physical disks attached to a SAS 5/iR controller may
  not display correct physical disk IDs in the Storage Management
  user interface.  (75371)

  Workaround: You may notice that Storage Management reports incorrect
  physical disk IDs after attaching an incompatible physical disk
  to a SAS 5/iR controller. A physical disk is incompatible if it is
  too small for the existing virtual disk configuration or if it is
  using an incompatible technology. For example, if a virtual disk
  is using SAS physical disks, then a SATA physical disk is
  incompatible.

  If the Dell OpenManage Storage Management service is running and you
  insert an incompatible physical disk, Storage Management assumes the
  disk is using SCSI technology and reports the disk ID in a 0:0 format.
  The physical disk ID for SAS and SATA disks is normally in a 0:0:0
  format when the physical disks are connected to the SAS 5/iR
  controller through a backplane.

  If Storage Management is restarted after you insert an incompatible
  physical disk, Storage Management does not display the physical disk
  at all.

  This behavior applies to the Storage Management graphical and
  command line interfaces.

  Workaround: Inserting a physical disk that is incompatible is an
  unsupported configuration. When inserting or replacing a
  physical disk, make sure the new disk meets the size and
  technology requirements.

* Storage Management responds slowly when using Internet Explorer 6.x
  on a system with mixed SAS and SATA physical disks.
  (60696)

  Issue:  When using the Create Virtual Disk wizard from the
  Storage Management graphical user interface (GUI), you may notice
  decreased performance when using Internet Explorer 6.x on a system
  with multiple Dell(TM) PowerVault(TM) MD1000 storage enclosures
  that are heavily populated with mixed SAS and SATA physical disks.

  Workaround: Use a supported browser other than Internet Explorer 6.x
  or use the Storage Management command line interface (CLI) to
  create the virtual disk. See the Dell OpenManage Server
  Administrator readme for information on supported browsers. See
  the Storage Management online help or the "Dell OpenManage Server
  Administrator Command Line Interface User's Guide" for information
  on using the Dell OpenManage Storage Management CLI.

* The system may require an extended period of time to boot when a
  tape device without a driver is attached. (35823)

  Issue:  Dell OpenManage Storage Management performs a discovery
  process for all attached devices when the system boots. The
  discovery process may take an extended period of time if the
  system has a tape device with no driver or an unsupported driver
  attached. When this occurs, the system requires a period of time
  in excess of ten minutes to complete the boot process.

  Workaround: Either detach the tape device from the system or
  install a supported version of the tape driver.

* Dell OpenManage Storage Management may not display controllers
  installed with the Service and Diagnostics utility. (152362)

  Issue: Storage Management may not recognize devices that are
  installed after Storage Management is already running.

  Workaround: If Storage Management does not recognize a newly-added
  device and this problem has not been corrected with a GLobal Rescan,
  then reboot the system.

* Storage Management SNMP traps are not filtered by Server
  Administrator. (120475)

  Issue: Server Administrator allows you to filter SNMP traps that
  you do not want to receive. To implement SNMP trap filtering,
  select the System tree object and then select the Alert Management
  tab and the SNMP Traps sub-tab. The SNMP Traps subtab has options
  for enabling or disabling SNMP traps based on severity or the
  component that generates the trap. Even when the SNMP traps are
  disabled, Storage Management will generate SNMP traps.

  Workaround: No workaround in this release.


======================================================================
Firmware for PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di,
4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 5/E, PERC 5/i Integrated,
PERC 5/i Adapter, SAS 5/iR Integrated, SAS 5/iR Adapter,
SAS 5/i Integrated, SAS 5/E Adapter, PERC 6/E Adapter,
PERC 6/i Integrated, PERC 6/i Adapter, SAS 6/iR Integrated,
SAS 6/iR Adapter, SAS 6/int. Modular, LSI 1020, and LSI 1030
Controllers

------------------------------
| Controller  | Firmware/    |
|             | BIOS         |
|             |              |
|             |              |
------------------------------
| PERC 3/DC   | 199D         |
|             |              |
|             |              |
------------------------------
| PERC 3/QC   | 199D         |
|             |              |
|             |              |
------------------------------
| PERC 3/SC   | 199D         |
|             |              |
|             |              |
------------------------------
| PERC 4/SC   | 352D         |
|             |              |
|             |              |
------------------------------
| PERC 4/DC   | 352D         |
| 32-bit      |              |
|             |              |
------------------------------
| PERC 4/DC   | 352D         |
| 64-bit      |              |
|             |              |
------------------------------
| PERC 4e/DC  | 522D         |
|             |              |
|             |              |
------------------------------
| PERC 4e/Si  | 522D         |
|             |              |
|             |              |
------------------------------
| PERC 4e/Di  | 522D         |
|             |              |
|             |              |
------------------------------
| PERC 4/Di   | 252D         |
| on a        |              |
| 2-Processor |              |
| 5U System-XP|              |
| PERC 4/Di   | 422D         |
------------------------------
| PERC 4/IM   | 1.00.12.00   |
| on an       | 	     |
| ES3005      |              |
|             |              |
------------------------------
| PERC 4/IM   | 1.03.23.90   |
| on a        |              |
| 2 Processor |              |
| 7U Modular  |              |
|  System     |              |
------------------------------
| PERC 5/E    | 5.2.2-0072   |
|             |              |
|             |              |
------------------------------
| PERC 5/i    | 5.2.2-0072   |
| Integrated  |              |
|             |              |
------------------------------
| PERC 5/i    | 5.2.2-0072   |
| Adapter     |              |
|             |              |
------------------------------
| SAS 5/iR    | 00.10.51.00/ |
| Integrated  | 06.12.05.00  |
|             |              |
------------------------------
| SAS 5/iR    | 00.10.51.00/ |
| Adapter     | 06.12.05.00  |
|             |              |
------------------------------
| SAS 5/i     | 00.10.51.00/ |
| Integrated  | 06.12.05.00  |
|             |              |
------------------------------
| SAS 5/E     | 00.10.51.00/ |
| Adapter     | 06.12.05.00  |
|             |              |
------------------------------
| PERC 6/E    | 6.1.1-0037   |
| Adapter     |              |
|             |              |
------------------------------
| PERC 6/i    | 6.1.1-0037   |
| Integrated  |              |
|             |              |
------------------------------
| PERC 6/i    | 6.1.1-0037   |
| Adapter     |              |
|             |              |
------------------------------
| SAS 6/iR    | 00.25.43.00/ |
| Integrated  | 06.22.01.00  |
|             |              |
------------------------------
| SAS 6/iR    | 00.25.43.00/ |
| Adapter     | 06.22.01.00  |
|             |              |
------------------------------
| SAS 6/int.  | 00.25.43.00/ |
| Modular     | 06.22.01.00  |
|             |              |
------------------------------


*** Windows Drivers for PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC,
4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 5/E,
PERC 5/i Integrated, PERC 5/i Adapter, SAS 5/iR Integrated,
SAS 5/iR Adapter, SAS 5/i Integrated, SAS 5/E Adapter,
PERC 6/E Adapter, PERC 6/i Integrated, PERC 6/i Adapter,
SAS 6/iR Integrated, SAS 6/iR Adapter, SAS 6/int. Modular,
LSI 1020, and LSI 1030 Controllers ***

------------------------------------------------------------------------------------------
| Controller  | Windows     | Windows     | Windows      | Windows       | Windows       |
|             | 2000        | Server      | Server       | Server	 | Server        |
|             | 32-bit      | 2003        | 2003         | 2008          | 2008          |
|             | Driver      | 32-bit      | 64-bit       | 32-bit        | 64-bit        |
|             |             | Driver      | Driver       | Driver        | Driver        |
------------------------------------------------------------------------------------------
| PERC 3/SC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Not           | Not           |
|             |             |             |              | Applicable    | Applicable    |
|             |             |             |              |		 |               |
------------------------------------------------------------------------------------------
| PERC 3/DC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Not           | Not           |
|             |             |             |              | Applicable    | Applicable    |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 3/QC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Not           | Not           |
|             |             |             |              | Applicable    | Applicable    |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/SC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Native        |
|             |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/DC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Native        |
| 32-bit      |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/DC   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        |  Native       |
| 64-bit      |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4e/DC  | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        |  Native       |
|             |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4e/Si  | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        |  Native       |
|             |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4e/Di  | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        |  Native       |
|             |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Native        |
| on a        |             |             |              |               | 		 |
| 2-Processor |             |             |              |               |               |
| 5U System-XP|             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Not           |
| on a        |             |             |              |               | Applicable    |
| PowerEdge   |             |             |              |               |               |
| 2600        |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Native        |
| on a        |             |             |              |               |     		 |
| 2-Processor/|             |             |              |               |               |
| 5U System-XP|             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    | Native        | Not           |
| on a        |             |             |              |               | Applicable    |
| PowerEdge   |             |             |              |               |               |
| 1750        |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/IM   | 1.08.06     | Native      | Not          | Not           | Not           |
| on an       |             |             | Applicable   | Supported     | Supported     |
| ES3005      |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
|PERC 4/IM    | 1.08.06     | Native      | Not          | Not           | Not           |
| on a        |             |             | Applicable   | Supported     | Supported     |
| PowerEdge   |             |             |              |               |               |
| 1655MC      |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 4/IM   | 1.09.11     | 1.09.11     | Native (SP1) | Native        | Native        |
| on a        |             |             | 1.09.11.53   |               |               |
| 2 processor/|             |             |              |               |               |
| 7U Modular  |             |             |              |               |               |
| System      |             |             |              |               |               |
------------------------------------------------------------------------------------------
|PERC 4/IM    | 1.09.11     | 1.09.11     | Native (SP1) | Native        | Native        |
| on a        |             |             | 1.09.11.53   |               |               |
| PowerEdge   |             |             |              |               |               |
| 1855        |             |             |              |               |               |
------------------------------------------------------------------------------------------
| CERC        | 5.46        | 6.41.2.32   | 6.41.2.32    | Not           | Not           |
| ATA 100/4CH |             |             |              | Supported     | Supported     |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 5/E    | 2.14.0.32   | 2.14.0.32   | 2.14.0.64    | Native     	 | Native     	 |
|             |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 5/i    | 2.14.0.32   | 2.14.0.32   | 2.14.0.64    | Native     	 | Native     	 |
| Integrated  |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 5/i    | 2.14.0.32   | 2.14.0.32   | 2.14.0.64    | Native     	 | Native   	 |
| Adapter     |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 5/iR    | 1.24.04.40  | 1.24.04.40  | 1.24.04.40   | Native    	 | Native    	 |
| Integrated  |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 5/iR    | 1.24.04.40  | 1.24.04.40  | 1.24.04.40   | Native    	 | Native    	 |
| Adapter     |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 5/i     | 1.24.04.40  | 1.28.02.00  | 1.28.02.00   | 1.28.02.00    | 1.28.02.00    |
| Integrated  |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 5/E     | 1.24.04.40  | 1.28.02.00  | 1.28.02.00   | 1.28.02.00    | 1.28.02.00    |
| Adapter     |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 6/E    | Not         |             |              |               |		 |
|             |	Supported   | 2.22.0.32   | 2.22.0.64    | 2.22.0.32     |2.22.0.64 	 |
| Adapter     |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 6/i    | Not         |             |              |               |		 |
|             |	Supported   | 2.22.0.32   | 2.22.0.64    | 2.22.0.32     |2.22.0.64 	 |
| Integrated  |             |             |              |               |		 |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| PERC 6/i    | Not         |             |              |               |		 |
|             |	Supported   | 2.22.0.32   | 2.22.0.64    | 2.22.0.32     |2.22.0.64 	 |
| Adapter     |             |             |              |               |               |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 6/iR    | Not 	    |		  |		 |		 |		 |
| Integrated  |	Supported   | 1.28.02.00  | 1.28.02.00   | 1.28.02.00 	 | 1.28.02.00  	 |
|             |             |             |              |               |		 |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 6/iR    | Not 	    |		  |		 |		 |		 |
| Adapter     |	Supported   | 1.28.02.00  | 1.28.02.00   | 1.28.02.00  	 | 1.28.02.00  	 |
|             |             |             |              |               |		 |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| SAS 6/iR    | Not 	    |		  |		 |		 |		 |
| Modular     |	Supported   | 1.28.02.00  | 1.28.02.00   | 1.28.02.00  	 | 1.28.02.00  	 |
| 	      |             |             |              |		 |		 |
|             |             |             |              |               |               |
------------------------------------------------------------------------------------------
| LSI 1020 on | 1.09.11     | 1.09.11     | 1.09.11      | Not           | Not           |
| a PowerEdge |             |             |              | Applicable    | Applicable    |
| 1600SC      |             |             |              |               |               |
------------------------------------------------------------------------------------------
| LSI 1030 on | 1.09.11     | 1.09.11     | 1.09.11      | Not           | Not           |
| a PowerEdge |             |             |              | Applicable    | Applicable    |
| 1750        |             |             |              |               |               |
------------------------------------------------------------------------------------------

*** Linux Drivers for PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di,
4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 5/E, PERC 5/i Integrated,
PERC 5/i Adapter, SAS 5/iR Integrated, SAS 5/iR Adapter,
SAS 5/i Integrated, SAS 5/E Adapter, PERC 6/E Adapter,
PERC 6/i Integrated, PERC 6/i Adapter, SAS 6/iR Integrated,
SAS 6/iR Adapter, SAS 6/int. Modular, LSI 1020, and LSI 1030
Controllers ***

--------------------------------------------------------------------
| Controller  | Redhat      | Redhat	|  SUSE       | SUSE        |
|             | Linux       | Linux	|  Linux      | Linux       |
|             | Driver      | Driver	|  9 64-Bit   | 10 64-bit   |
|             | 4.5         | 5.0	|  Driver     | Driver      |
---------------------------------------------------------------------
| PERC 3/SC   | 2.20.4.4    | Native	| Not         | Not         |
|             |             |		| Applicable  | Applicable  |
|             |             |           |	      |             |
---------------------------------------------------------------------
| PERC 3/DC   | 2.20.4.4    | Native	| Not         | Not         |
|             |             |           |Applicable   | Applicable  |
|             |             |           |	      |             |
---------------------------------------------------------------------
| PERC 3/QC   | 2.20.4.4    | Native	| Not         | Not         |
|             |             |		| Applicable  | Applicable  |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/SC   | 2.20.4.4    | Native	| Not         | Not         |
|             |             |		| Applicable  | Applicable  |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/DC   | 2.20.4.4    | Native	| Native      | Native      |
| 32-bit      |             |		| 2.20.4.6    | 2.20.4.7    |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/DC   | 2.20.4.4    | Native    | Native      | Native      |
| 64-bit      |             |		| 2.20.4.6    | 2.20.4.7    |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4e/DC  | 2.20.4.4    | Native    | Native      | Native      |
|             |             |		| 2.20.4.6    | 2.20.4.7    |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4e/Si  | 2.20.4.4    | Native    | Not         | Not         |
|             |             |		| Applicable  | Applicable  |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4e/Di  | 2.20.4.4    | Native	| Not         | Not         |
|             |             |		| Applicable  | Applicable  |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/Di   | 2.20.4.4    | Native	| Not         | Not         |
| on a        |             |		| Applicable  | Applicable  |
| PowerEdge   |             |		|             |             |
| 2600/ on a  |		    |		|	      |  	    |
| 2-processor |		    |		|	      |		    |
| 5U System-XP|		    |		|	      |		    |
|             |		    |           |             |		    |
---------------------------------------------------------------------
| PERC 4/Di   | 2.20.4.4    | Native	| Not         | Not         |
| on a        |             |		| Applicable  | Applicable  |
| PowerEdge   |             |		|             |             |
| 1750        |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/IM   | Not         | Native	| Not         | Not         |
| on a ES3005/| Applicable  |		| Applicable  | Applicable  |
| PowerEdge   |             |		|             |             |
| 1655MC      |             |		|             |             |
---------------------------------------------------------------------
| PERC 4/IM   | Native      | Native	| Not         | Not         |
| on a        | 3.01.16     |		| Applicable  | Applicable  |
| 2 Processor |             |		|             |             |
| 7U Modular  |             |           |             |             |
| System      |             |		|             |             |
---------------------------------------------------------------------
| CERC        | 2.20.4.4    | Native	| Not         | Not         |
| ATA 100/4CH |             |		| Applicable  | Applicable  |
|             |             |		|             |             |
---------------------------------------------------------------------
| PERC 5/E    |03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|
|             |             |		  |             |	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| PERC 5/i    |03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|
| Integrated  |             |		  |             |	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| PERC 5/i    |03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|03.13.00.00-1|
| Adapter     |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 5/iR    |02.06.62.02-2|02.06.62.02-2|02.06.62.02-2|02.06.62.02-2|
| Integrated  |             |		  |             | 	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 5/iR    |02.06.62.02-2|02.06.62.02-2|02.06.62.02-2|02.06.62.02-2|
| Adapter     |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 5/i     | 3.12.29.00-3| 4.00.38.01-1| 3.12.29.00-3| 4.00.38.01-1|
| Integrated  |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 5/E     | 3.12.29.00-3| 4.00.38.01-1| 3.12.29.00-3| 4.00.38.01-1|
| Adapter     |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| PERC 6/E    |00.00.03.20  |00.00.03.20  |00.00.03.20  |00.00.03.20  |
| Adapter     |             |		  |             |	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| PERC 6/i    |00.00.03.20  |00.00.03.20  |00.00.03.20  |00.00.03.20  |
| Integrated  |             |		  |             |	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| PERC 6/i    |00.00.03.20  |00.00.03.20  |00.00.03.20  |00.00.03.20  |
| Adapter     |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 6/iR    |3.12.29.00-3 | 4.00.38.01-1| 3.12.29.00-3| 4.00.38.01-1|
| Integrated  |             |		  |             |             |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 6/iR    |3.12.29.00-3 | 4.00.38.01-1| 3.12.29.00-3| 4.00.38.01-1|
| Adapter     |             |		  |             | 	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| SAS 6/int.  |3.12.29.00-3 | 4.00.38.01-1| 3.12.29.00-3| 4.00.38.01-1|
| Modular     |             |		  |             |    	      |
|             |             |		  |             |             |
-----------------------------------------------------------------------
| LSI 1020 on | Native      | Not	  | Not         | Not         |
| a PowerEdge |             | Applicable  | Applicable  | Applicable  |
| 1600SC      |             |		  |             |             |
-----------------------------------------------------------------------
| LSI 1030 on | Native      | Not	  | Not         | Not         |
| a PowerEdge |             | Applicable  | Applicable  | Applicable  |
| 1750        |             |		  |             |             |
-----------------------------------------------------------------------

Note: Storage Management requires that the system be rebooted before
      Storage Management can properly determine whether the system
      meets the firmware and driver requirements for the PERC 3/Si,
      and PERC 3/Di controllers. For this reason, it is possible to
      complete an initial installation of Storage Management without
      being notified whether your system meets the firmware and
      driver requirements.

======================================================================
FIRMWARE AND DRIVER REQUIREMENTS FOR THE PERC 3/Si, and PERC 3/Di,
CONTROLLERS
======================================================================
*** Firmware for PERC 3/Si and PERC 3/Di Controllers ***

----------------------------
| Controller  | Firmware   |
----------------------------
| PERC 3/Si   | 2.8.1.6098 |
|             |            |
----------------------------
| PERC 3/Di   | 2.8.1.6098 |
|             |            |
----------------------------
| CERC        | 4.1.0.7419 |
----------------------------

----------------------------------------------------------------------------------
| Controller  | Windows     | Windows     | Windows    | Windows    | Windows    |
|             | 2000        | Server      | Server     | Server     | Server     |
|             | Driver      | 2003        | 2003       | 2008       | 2008       |
|             |             | 32-bit      | 64-bit     | 32-bit     | 64-bit     |
|             |             | Driver      | Driver     | Driver     | Driver     |
----------------------------------------------------------------------------------
| PERC 3/Si   | 2.8.0.6085* | 2.8.0.6085* | 2.8.0.6076 | Not        | Not        |
|             |             |             |            | Applicable | Applicable |
----------------------------------------------------------------------------------
| PERC 3/Di   | 2.8.0.6085* | 2.8.0.6085* | 2.8.0.6076 | 2.8.1.7691 | Not        |
|             |             |             |            |            | Applicable |
----------------------------------------------------------------------------------
| CERC        | 4.1.1.7040  | 4.1.1.7040  | 4.1.1.7040 | 4.1.1.7043 | 4.1.1.7043 |
| SATA1.5/6ch |             |             |            |            |            |
----------------------------------------------------------------------------------
| CERC        | 6.0.50.5    | 6.0.50.5    | 6.0.3643.4 | Not	    | Not        |
| SATA1.5/2s  |             |             |            | Applicable | Applicable |
----------------------------------------------------------------------------------

Note: * The 2.8.0.6085 driver install package for the PERC 3/Si,
        and 3/Di controllers contains the 2.8.0.6076 driver.
        For this driver, Storage Management displays 2.8.0.6076
        whereas Windows Device Manager displays 2.8.0.6085.


*** Linux Drivers for PERC 3/Si, PERC 3/Di Controllers and CERC controllers***
--------------------------------------------------------------------------------
| Controller  | Redhat     | Redhat     | Redhat     | SUSE       | SUSE       |
|             | Linux      | Linux      | Linux      | Linux      | Linux      |
|             | Driver     | Driver     | Driver     | 9 64-bit   | 10 64-bit  |
|             | 3.0        | 4.0        | 5.0        | Driver     | Driver     |
--------------------------------------------------------------------------------
| PERC 3/Si   | 1.1.4**    | Not        | Not        | Not        | Not        |
|             |            | Applicable | Applicable | Applicable | Applicable |
--------------------------------------------------------------------------------
| PERC 3/Di   | 1.1.4**    | 1.1.5.2392 | Not        | Not        | Not        |
|             |            |            | Applicable | Applicable | Applicable |
--------------------------------------------------------------------------------
| CERC        | 1.1.5.2372 | 1.1.5.2392 | Not        | Not        | Not        |
| SATA1.5/6ch |            |            | Applicable | Applicable | Applicable |
--------------------------------------------------------------------------------
| CERC        | 1.1.5.2372 |1.1.5.2392  | Not        | Not        | Not        |
| SATA1.5/2s  |            |            | Applicable | Applicable | Applicable |
--------------------------------------------------------------------------------

Note: ** The 1.1.4 Linux driver is included in RPM 2302
         (Release Package Manager 2302).

======================================================================
ADAPTEC NON-RAID ULTRA SCSI CONTROLLER CARDS
======================================================================

The Ultra SCSI controller cards (non-RAID SCSI) include Ultra SCSI,
Ultra2 SCSI, Ultra160 SCSI, Ultra320 SCSI.

Support for the Ultra SCSI controller cards is provided in the BIOS.

======================================================================
PREREQUISITE DRIVERS AND FIRMWARE ON LINUX
======================================================================

On Linux, Storage Management installation cannot detect whether
the drivers and firmware on the system are at the required level for
installing and using Storage Management. When installing on Linux,
you will be able to complete the installation regardless of whether
the driver and firmware versions meet the required level. Even though
you complete the installation, installing on a system that does
not meet the driver and firmware version requirements is an
unsupported configuration. In particular, you may find that
controllers and their features are not displayed by Storage
Management on a system that does not meet the driver and firmware
requirements. At Storage Management runtime, you can determine
whether the system meets the firmware requirements by checking your
application log files for notifications on outdated firmware. On SCSI
controllers, Storage Management displays the firmware version at
runtime. On SAS controllers, Storage Management displays both the
firmware and the driver version at runtime.



######################################################################

Information in this document is subject to change without notice.
(C) 2008 Dell Inc. All rights reserved.

Reproduction in any manner whatsoever without the written
permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: "Dell," "OpenManage," and "PowerVault"
are trademarks of Dell Inc.; "Microsoft," "Windows," and "Windows
Server" are registered trademarks of Microsoft Corporation in the
United States and other countries; "SUSE," "Novell," and "NetWare"
are registered trademarks of Novell, Inc.; "Red Hat" and "Enterprise
Linux" are a registered trademark of Red Hat, Inc.

Other trademarks and trade names may be used in this document to
refer to either the entities claiming the marks and names or their
products. Dell Inc. disclaims any proprietary interest in trademarks
and trade names other than its own.

September 2008
VERSION 3.0 README