DELL(TM) OPENMANAGE(TM) SERVER ADMINISTRATOR VERSION 5.5 README

######################################################################

Version - 5.5
Release Date - September 2008

NOTE: This readme provides information on Dell(TM) OpenManage(TM)
      Server Administrator version 5.5.

This file contains updated information for your "Dell OpenManage
Server Administrator User's Guide" and any other technical
documentation included with Server Administrator.

NOTE: Dell OpenManage System Management software, including Server
      Administrator, is available only on the "Dell Systems
      Management Tools and Documentation" DVD.

NOTE: See the Dell OpenManage Storage Management readme for
      more information on the Storage Management
      Service.

The Server Administrator documentation includes the "User's Guide,"
"Messages Reference Guide," "CIM Reference Guide," "Command Line
Interface (CLI) User's Guide," "SNMP Reference Guide," and
"Compatibility Guide". You can access the documentation from the
Dell Systems Management Tools and Documentation DVD or from the
Dell support website at "support.dell.com".

This file contains the following sections:

* Criticality

* Minimum Requirements

* Release Highlights

* Installation

* User Notes

* Known Issues

#####################################################################
CRITICALITY
#####################################################################

3 - Optional

Dell recommends that you review specifics about the update to
determine if it applies to your system. The update contains changes
that impact only certain configurations and provides new features
that may or may not apply to your environment.

#####################################################################
MINIMUM REQUIREMENTS
#####################################################################

This section provides information about the minimum requirements for
installing and using Server Administrator.


* See the latest Dell Software Support Matrix contained on the
  media for the latest and complete list of supported operating
  system and platforms.

* See the "ISSUES FOR DRAC 5" section of this document for
  the latest information on all supported web browsers and
  managed server operating system by DRAC 5.


=====================================================================
SUPPORTED WEB BROWSERS
=====================================================================

* Microsoft(R) Internet Explorer 6.0 (SP2) on Microsoft Windows(R)
  Server 2000.

* Microsoft Internet Explorer 6.0 (SP2) and 7.0 on Microsoft Windows
  Server(R) 2003 and Microsoft Windows Server 2008.

* Firefox 1.5 on Red Hat(R) Enterprise Linux (AS, ES, WS) version 4.5
  and version 5 and SUSE(R) Linux Enterprise Server version 9 SP3 and
  version 10.

* FireFox 2.0 on Microsoft Windows Server 2003, Microsoft Windows
  Server 2008, Red Hat Enterprise  Linux (AS, ES, WS) version 4.5 and
  version 5 and SUSE Linux Enterprise Server version 9 SP3 and 10.

  NOTE: See the "ISSUES FOR DRAC 5" section of this document for the
  browsers supported by DRAC 5.

  NOTE: The Server Administrator attempts to use the
  available browser on the system. However, under certain
  circumstances, using an unsupported (version or unsupported type)
  browser may not be reported to you. In such cases you may see
  unexpected or incomplete results.

  NOTE: The operating system media browser install may not be the
  version supported by Server Administrator. See the appropriate Red
  Hat Enterprise Linux operating system documentation to upgrade the
  base browser install version to the supported version.

=====================================================================
SUPPORTED SSL VERSION
=====================================================================

* Server Administrator supports SSL 3.0 exclusively.

=====================================================================
SUPPORTED RAC FIRMWARE
=====================================================================

* iDRAC firmware version 1.0 or greater is required for systems
  installed with iDRAC.

* DRAC 5 firmware version 1.0 or greater is required for systems
  installed with DRAC 5.

* On systems installed with a DRAC 4/I and DRAC 4/P firmware version
  1.0 or greater is required.

* RAC firmware version 3.20 or greater is required for DRAC III,
  DRAC III/XT, ERA, and ERA/O.

#####################################################################
RELEASE HIGHLIGHTS
#####################################################################

* Added installation support for the following operating systems:

   - Microsoft(R) Windows(R) Essential Business
     Server 2008 - Standard and Premium editions.

   - Microsoft(R) Windows(R) Small Business Server 2008 Standard
     and Premium editions.

   - Microsoft Hyper-V(R) and Hyper-V Server.

   - SUSE(R) Linux Enterprise Server version 10 (SP2).

   - RedHat(R) Enterprise Linux(R) WS,ES, and AS (Version 4.7).

   - VMware(R) ESX Version 3.5 (Update 2).

   - Citrix(R) XenServer Dell Edition 5.0 Flash and HDD Image

   NOTE: Microsoft Windows Essential Business Server 2008 will
   become available in the second half of 2008. For latest
   information, see http://www.microsoft.com/windowsserver/essential
   /ebs/default.mspx.

   NOTE: Microsoft Windows Small Business Server 2008 will become
   available in the second half of 2008. For latest information,
   see http://www.microsoft.com/windowsserver/essential/
   sbs/default.mspx.

* Added support for the following Dell PowerEdge(R) systems:
  M805 and M905.

* See the "Dell Systems Software Support Matrix" for a complete list
  of supported Dell systems and operating systems.


#####################################################################
INSTALLATION
#####################################################################

For complete installation instructions, see the "Dell OpenManage
Installation and Security User's Guide".

#####################################################################
USER NOTES
#####################################################################

This section provides information to help enhance your experience with
Server Administrator.

* Server Administrator uses port 1311 as the default port. Port 1311
  is a registered port number of Dell Inc. If another application is
  configured to run on port 1311 before Server Administrator is
  installed, the Dell Systems Management Server Administrator (DSM SA)
  Connection Service will not start after installation. Before you
  install Server Administrator, ensure that port 1311 is not being
  used.

* You need to enable client-side scripting in Internet Explorer
  before starting Server Administrator. To do so, perform the
  following steps:

  1. Navigate to "Tools" in Internet Explorer.

  2. Under Tools, click "Internet Options".

  3. Under "Internet Options", click the "Security" tab.

  4. Select the security zone that the system running Server
     Administrator belongs to.
     NOTE: This option should be set to "Trusted sites".

  5. Click the "Custom Level" button.

  6. For Windows 2000, perform the following steps:

     - Under "Miscellaneous", select the "Allow Meta Refresh" radio
       button.

     - Under "Active Scripting", select the "Enable" radio button.

  7. For Windows 2003, perform the following steps:

     - Under "Miscellaneous", select the "Allow Meta Refresh" radio
       button.

     - Under "Active Scripting", select the "Enable" radio button.

     - Under "Active scripting", select the "Allow scripting of
       Internet Explorer web browser controls" radio button.

     - Click "OK" and restart your browser.

  8. For Windows 2008, perform the following steps:

     - Under "Miscellaneous", select the "Allow Meta Refresh" radio
       button.

     - Under "Active Scripting", select the "Enable" radio button.

     - Under "Active scripting", select the "Allow scripting of
       Internet Explorer web browser controls" radio button.

     - Click "OK" and restart your browser.

* To allow Single Sign-on for Server Administrator, perform the
  following steps:

  1. Navigate to "Tools" in Internet Explorer.

  2. Under "Tools", click "Internet Options"

  3. Under "Internet Options", click the "Security" tab.

  4. Select "Trusted sites".

  5. Click the "Custom Level" button.

  6. Under "User Authentication", select the "Automatic Logon with
     current username and password" radio button. Press OK' to exit
     the "Custom Level" window.

  7. Now select the "Advanced" tab, and under "HTTP 1.1 settings",
     make sure "Use HTTP 1.1" is checked.

  8. Select "Trusted sites". Click "Sites". Add server to the
     website. Click "Close".

  9. Click "OK" and restart your browser.

* If you run a security scanner tool (such as Nessus) against the
  Server Administrator Web server, certain security warnings against
  port 1311 running the Server Administrator Web server may be
  displayed. The following warnings have been investigated by Dell
  engineering and are determined to be "false positives"
  (invalid security warnings) that you can safely ignore:

  * "The Web server on 1311 allows scripts to read sensitive
    configuration and / or XML files." Dell has determined that this
    warning is a false positive.
  * "The Web server on 1311 allows to delete " / " which implies that
    the Web server will allow a remote user to delete the files in
    root on the server." Dell has determined that this warning is a
    false positive.
  * "The Web server on 1311 might be susceptible to a 'WWW Infinite
    Request' attack." Dell has determined that this warning is a
    false positive.
  * "It is possible to make the remote thttpd server execute
    arbitrary code by sending a request like:

    GET If-Modified-Since:AAA[...]AAAA

    Solution: If you are using thttpd, upgrade to version 2.0. If you
    are not, then contact your vendor and ask for a patch, or change
    your Web server. CVE on this one is CAN-2000-0359". Dell has
    determined that this warning is a false positive.

* Enabling Integrated Windows Authentication in Internet Explorer
  is not required to activate the Single Sign-On feature.

* Server Administrator security settings are not applicable for
  Active Directory users. Active Directory users with read-only login
  can access Server Administrator, even after access is blocked in
  the preferences page of Server Administrator.

* Dell SNMP MIB Files for Dell Systems

  Dell SNMP MIB files for Dell systems allow customers to obtain
  and verify information provided by supported software agents.  The
  current MIB files supported by Dell PowerEdge(TM) software agents
  are located at "\support\mib" on the Dell Systems Management Tools
  and Documentation DVD.

  NOTE: A MIB-II-compliant, SNMP-supported network management station
        is required to compile and browse MIB files.

* Dell(TM) OpenManage(TM) support for EFS (Encrypting File System)

  To improve security, Microsoft provides the capability to encrypt
  files using EFS (Encrypting File System). Note that Server
  Administrator will not function if its dependent files are
  encrypted.

* Server Administrator GUI and CLI Response Time

  On Dell PowerEdge x8xx and later systems, the response time
  for some parts of the OMSA GUI and CLI have increased to several
  seconds because some of the BMC/iDRAC data is no longer cached
  by Server Administrator.  The data must be retrieved from the
  BMC or iDRAC when requested by the user.

  You may notice a delayed response on the following Server
  Administrator GUI pages:
  - Server Administrator home page on log in
  - Remote Access -> Users
  - Alert Management -> Platform Events

 You may notice a delayed response on the following Server
 Administrator CLI commands:
  - omreport chassis remoteaccess config=user
  - omreport system platformevents
  - omreport system pedestinations


- The response time varies depending on the system hardware and
  operating system. [188345]


=====================================================================
NOTES FOR THE INSTRUMENTATION SERVICE
=====================================================================

* On certain systems, user-defined thresholds set under Server
  Administrator become the default thresholds after uninstalling
  Server Administrator.

  After you change the threshold value of a probe on certain systems
  running Server Administrator and then uninstall Server Administrator,
  the changed threshold value becomes the default threshold value.

* When modifying the warning threshold settings, the values are stored
  in the firmware as discrete integer values and scaled for display.
  If the modified value is not a discrete integer, it may change when
  saved.

* Fan redundancy can have the following states:

   - Fully Redundant: The sensors display this status, if all the
     fans in the system are present and are in a non-failure state.

     OR

   - Redundancy Lost: The sensors display this status, whenever any
     system fan fails or is removed from the chassis.

* Additionally, on Dell PowerEdge 6800, the sensors will report a fan
  redundancy status of "Redundancy Lost" in the following
  scenarios:

  - A power supply is removed and a power supply fan blank is not
    inserted.
  - A power supply fan blank is present but has failed.[134157]

* If a system with memory redundancy enabled enters a "redundancy
  lost" state, it may not be apparent which memory module is the
  cause. If you cannot determine which DIMM to replace, see the
  "switch to spare memory detected" log entry in the ESM system
  log to find the memory module that failed.

* If you run Server Administrator while the system is in "OS Install
  Mode", memory may be reported incorrectly by Server Administrator.
  To avoid this issue, you must disable "OS Install Mode" before
  running Server Administrator.

* If you have to uninstall and reinstall the operating system SNMP
  service, then reinstall Server Administrator as well, so that the
  Server Administrator SNMP agents are registered with the operating
  system SNMP agent.

* Server Administrator Device Drivers for Linux:

  Server Administrator includes two device drivers for Linux: Dell
  Systems Management Base Driver (dcdbas) and Dell BIOS Update Driver
  (dell_rbu).  Server Administrator uses these drivers to perform its
  systems management functions.  Depending on the system, Server
  Administrator loads one or both of these drivers if required.
  These drivers have been released as open source under the GNU
  General Public License v2.0.  They are available in Linux kernels
  from kernel.org starting with kernel 2.6.14.

  - Red Hat Enterprise Linux:

    Server Administrator provides precompiled dcdbas and dell_rbu
    modules for Red Hat Enterprise Linux version 4.5.  These drivers
    also ship with Red Hat Enterprise Linux version 4.5 and
    version 5.  It is expected that future Red Hat Enterprise Linux
    version 4.5 and 5 Updates will continue to ship these drivers.

  - SUSE Linux Enterprise Server:

    These drivers ship with SUSE Linux Enterprise Server version 9
    SP 3 and version 10.  It is expected that future
    SUSE Linux Enterprise Server version 9 and 10 Service Packs will
    continue to ship these drivers.

  If the drivers are available with the operating system, Server
  Administrator will use those versions of the drivers.  If the
  drivers are not available with the operating system, Server
  Administrator will use its precompiled modules on Red Hat
  Enterprise Linux version 4.  If precompiled drivers are not
  available with the operating system or Server Administrator,
  Server Administrator uses its Dynamic Kernel Support (DKS) feature
  to build the drivers when needed.  See the "Dell OpenManage
  Installation and Security User's Guide" for more information about
  DKS.

=====================================================================
NOTES FOR THE STORAGE MANAGEMENT SERVICE
=====================================================================

* When using the Storage Management Service, Stop the DSM SA Data
  Manager Services before updating the Adaptec(R) Controllers.

* Detailed information on the Storage Management Service is available
  in the Storage Management Service online help. After installing and
  launching Server Administrator, you can access the Storage
  Management Service online help by selecting the Storage or
  lower-level tree object and clicking the Help button on the global
  navigation bar.

=====================================================================
NOTES FOR THE REMOTE ACCESS SERVICE
=====================================================================

* This service is supported on Dell 650, 700, 750, 800, 830, 840, 850,
  860, 1600SC, 1650, 1750, 1800, 1850, 2600, 2650, 2800, 2850, 4600,
  6600, 6650, 6800, 6850, 6950, 2970, R200, M600, M605,R805,
  and R900 systems only. It enables remote access to a  server that
  has lost its network connection or that has become unresponsive. In
  this release of Server Administrator, the Remote Access Service uses
  the following Remote Access Controllers (RACs):
  Integrated Dell Remote Access Controller (iDRAC), DRAC5, DRAC 4/I,
  DRAC 4/P, DRAC III, DRAC III/XT, Embedded Remote Access (ERA), or
  Embedded Remote Access Option (ERA/O).

* RACs also have their own CLI that is accessed through the "racadm"
  command. You can add racadm commands to a batch or script file to
  automate various user tasks. To limit the stress load on the
  managed system and RAC, add "sleep" or "delay" commands of one or
  two seconds between the individual racadm commands.

* Unlike DRAC 3, configuration of DRAC 4 settings is not supported in
   Server Administrator. Additionally, Server Administrator performs
   minimal reporting of DRAC 4 properties. For DRAC 5, a limited
   amount of NIC and User settings are configurable through Server
   Administrator to allow the user to connect via Out-Of-Band to the
   DRAC 5 card. For full configuration and reporting of all DRAC
   attributes, it is recommended to use the "racadm" command.

* After installing Internet Explorer 5.0 or later, you may notice that
  the automatic configuration and proxy setting information for each
  connection is separate from the same information used for the LAN
  connection. If you have a dial-up and a LAN connection at the
  same time, Internet Explorer may block your access to the Internet.

  This blocking occurs because each connection in Internet Explorer
  5.0 uses its own automatic configuration and proxy settings. When
  you try to establish a PPP connection, Internet Explorer attempts
  to use the dial-up connection settings to access the Internet.

  You can find additional information about this issue in article
  Q818060, "Connections No Longer Use Local Area Network Automatic
  Configuration and proxy settings" in the Microsoft  Knowledge Base
  (KB) at "support.microsoft.com".

  To correct this problem, you must apply Microsoft IE HotFix Q818060
  or KB839571 to Internet Explorer 6.0 SP1 on Windows 2000 server or
  Windows 2003 server. HotFix Q818060 and KB839571 are available on
  the "Dell Systems Management Tools and Documentation DVD" in the
  "SYSMGMT\srvadmin\windows\HotFix" directory. See the following
  Microsoft support articles for further instructions on applying
  this HotFix:

    (Windows 2000 Server) "http://support.microsoft.com?kbid=818060"
    (Windows 2003 Server) "http://support.microsoft.com/kb/839571"

  As explained in the Microsoft KB article, use the Registry
  Editor ("regedit.exe") to browse to the following key:

    HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion
    \Internet Settings\

  If "DialupUseLanSettings" key is not present, create a registry item
  for "DialupUseLanSettings" and set a value of "1". Make sure the
  value type is "DWORD".

  Note: HotFix Q818060 may still fail to install on Internet Explorer
  6.0 SP1. If the error "This update requires Internet Explorer 6.0
  SP1 to be installed" occurs, follow these steps:

    1. Unzip "Q818060-Eng-IE6.zip".

    2. From a Windows command shell, enter "Q818060.exe /C" to
       extract the HotFix files to a directory.

    3. In the command shell, switch to the directory and then enter
       "ieupdate.exe Q818060".

    4. Launch Internet Explorer, open the "Help" menu, and select
       "About Internet Explorer". Verify that "Q818060" appears in
        the "Update Versions" field.

#####################################################################
KNOWN ISSUE
#####################################################################

This section provides information on open issues with this release of
Server Administrator.

=====================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL SUPPORTED OPERATING
SYSTEMS
=====================================================================

* On Dell PowerEdge 1950, 2950 and Dell PowerVault NX 1950 systems
  with internal USB, BIOS setting configuration for Internal USB Port
  is possible only if UA (User Accessible or external) USB ports are
  set to All Ports On. If UA USB ports are not set to 'All Ports On'
  and user tries to configure BIOS setting for Internal USB Port
  using Server Administrator GUI or CLI, the configuration will
  appear to be successful but the changes will not take effect on
  next reboot. If UA USB ports settings are changed from All Ports
  On to All Ports Off or Only Back Ports On, it will automatically
  set the Internal USB Port to Off on next reboot.

* Due to resource non-availability, inventory collection may
  terminate unexpectedly and restart.  If this occurs, the folder
  "C:\Temp\invcol" may be left as an artifact.  The presence of this
  folder does not affect functionality of the inventory collection.
  The folder can be deleted if required. [138549]

* After installing Server Administrator from the command prompt,
  do not run the commands "omreport" or "omconfig" from the same
  prompt as this might cause an error. Open a new command prompt and
  run the commands from the new window.

* If the command log page in the Server Administrator GUI displays
  an error message indicating that the XML is malformed, you must
  clear the command log from the CLI using the "omconfig system
  cmdlog action=clear" command.

* After a "Reset to Defaults" operation of the BMC Management
  controller, the first user configuration operation will fail if it
  is a single user configuration item (such as enabling or disabling
  a user or changing user name). Always change a combination of two
  user configuration items (such as enabling or disabling a user and
  changing user name) concurrently during your first configuration
  operation.[136599]

* On Dell PowerEdge 750 systems, if you disable the Power button in
  Server Administrator, the system does not power cycle or power down
  in the event of system instability or blue screens. In such
  cases, remove the power cord from the system to power down the
  unit. As the startup and recovery options in the operating system
  override those of Server Administrator, you need to configure them
  in the operating system to restart the system after a crash.

  NOTE: The above situation is applicable only when the "reboot"
  option in the startup and recovery options is disabled. If the
  "reboot" option is enabled, the system will automatically reboot
  and you will not be forced to shut down by removing the power cord.
  [126837]

* While browsing through IT Assistant, if the SNMP protocol is
  disabled and the CIM protocol is enabled, the redundancy status is
  shown as lost even though the system has full redundancy. To
  confirm the correct state of the system, use the Server
  Administrator user interface.

* If you have a RAID 1 virtual disk on a CERC SATA 1.5/6ch
  controller, performing a Format or Split Mirror operation
  may fail. Dell is working to resolve this problem.

* When issuing the Server Administrator command line "omreport
  system version -outc <filename>", make sure you specify an absolute
  path name for the output file, for example, "c:\out.txt";
  otherwise, the output file will be empty.

* Issuing the "omreport system esmlog/alertlog/cmdlog -fmt tbl"
  command on the CLI can result in XML parsing errors if the size
  of the log is very large. Use the GUI or the "omreport system
  esmlog/alertlog/cmdlog" CLI command to view the contents of
  the log.[12499]

* For complex "omconfig" CLI commands that contain multiple commands
  in one command line, the CLI may report a success status for the
  command even if part of the command failed. To avoid this issue,
  run only one command per command line. The current settings can be
  confirmed by performing the corresponding "omreport" command.

* Some complex "omconfig" CLI commands that contain multiple set
  operations have been modified to avoid the above problem. If, while
  executing a CLI command you receive the message "Error! Illegal
  combination of parameters", modify your command into several
  simpler commands. Each command should change only one setting.

* When running Server Administrator on a system with a Traditional
  Chinese operating system, the Server Administrator pages are
  displayed in Simplified Chinese. To view Server Administrator in
  English, go to your browser language preference page and change
  the language to English.

* Log files saved from Server Administrator are saved in zip
  format. For best results, it is recommended to open this zip file
  using WinZip. Using the Windows Server 2003 or Windows XP embedded
  "Compressed (zipped) Folder" utility is not recommended.

* After configuring BIOS settings on certain systems, a second
  reboot may be required for updated BIOS settings to be properly
  displayed by Server Administrator.

* If you import an invalid root certificate into Server Administrator
  using "Preferences-> General Settings-> Web Server-> X.509
  Certificate" and try to log in to Server Administrator after
  restarting the Web server, you will see a blank page.

  To correct this issue, restore your original "keystore.db" file
  before importing a valid root certificate. To restore the
  "keystore.db" file, use both the basic operating system commands
  and the Server Administrator CLI. Perform the following steps
  from your operating system command line:

  1. Type:

     omconfig system webserver action=stop

  2. Locate the "keystore.db.bak" file. The default path is
     "C:\program files\dell\SysMgt\iws\config".

  3. Copy "keystore.db.bak" to "keystore.db".

  4. Type:

     omconfig system webserver action=start

* A temperature that drops below a minimum failure threshold does not
  cause a system reset even if this alert action is set.

* A reporting error, for the amount of memory enabled, may exist for
  the Level 2 (L2) cache memory when you view "Processor interface"
  for Dell PowerEdge 6600 and 6650 systems. It may be incorrectly
  displayed as 256 K.

  If you purchased more than 256 K of L2 cache with your system, all
  of the L2 cache you have installed is fully enabled. The reporting
  error will be corrected in a future BIOS release for Dell PowerEdge
  6600 and 6650 systems.

* Clicking the browser "Back" and "Refresh" buttons may not display
  the correct page with respect to the Server Administrator component
  tree, tabs, tab menus, or help as Server Administrator has been
  designed with limited functionality to reduce overhead. Full
  feature capabilities of the web browser such as "Back", "Refresh",
  and "Open in New Window" may not be supported.

  Example:

  1. Click "Main System Chassis" under "System Component Tree".

  2. Click "Fans" under "Main System Chassis".

  3. Click "Alert Actions" on the tab menu bar.

  4. Click the "Back" button on the browser.

  This will take you to the "Fan Probes" page, leaving the tab menu
  bar unchanged. The "Fan Probes" page under "Alert Actions" on the
  tab menu bar instead of "Fan Probes".

* Selecting the boot sequence under the BIOS "Setup" tab does not
  re-enable boot devices that have been previously disabled in
  the System Setup Program.

* The links on the Server Administrator home page may lock up after
  repeated random clicking. To resolve this situation, refresh the
  browser by pressing <F5> or click the browser "Refresh" button.

* All unsecured HTTP requests to Server Administrator receive an
  invalid response. Server Administrator runs only one instance of
  the Web server, which is secure. Make all connections through
  https://<ip address> : <port number>. Any "http://<ip address>:
  <port number>" request for connection with the server receives an
  invalid response.

* If the browser used with Server Administrator indicates that it
  cannot display a page or perform an action, ensure that the browser
  is in online mode. To go online, perform the following:

  -  If you are using Internet Explorer, click "File" on the
     menu bar and deselect the "Work Offline" option. When "Work
     Offline" is selected, a check displays to the left of the option
     on the "File" menu.

* If Internet Explorer prompts you to "Work Offline", "Connect", or
  "Try Again", always select "Connect" or "Try Again". Do not select
  "Work Offline".

* When setting dates in the "Asset Information" section of the Server
  Administrator home page, the current time is appended to the date.
  When setting dates with the CLI, the appended time is noon.

* If Network Adapter Teaming is installed and enabled on your system,
  Server Administrator does not display the IP address or other
  connection-related data for the individual network adapters. The
  connection status and IP address belong to the virtual adapter
  created by the teaming software.

* On some systems, temperature probe values and settings are only
  supported for whole degrees, not tenths of a degree. On these
  systems, setting a fractional value for the minimum warning
  temperature threshold results in the set value being rounded down
  to the next whole number value. This behavior may cause the minimum
  warning threshold to have the same value as the minimum failure
  threshold.

* Mozilla-based browsers (including Firefox) share states, including
  cookies and browser session information, across multiple instances
  under the same login session. If a user (or root user) has logged
  in to multiple Mozilla/Firefox browser instances, then the session
  management shows only one session (the last log-in session) for
  that user. If a user (or root user) tries to log in to multiple
  Mozilla/Firefox browser instances, then only the last session is
  active and the other older sessions display access forbidden upon
  the next access.

* If a user closes the browser using browser close button or logs off
  from the OS, the Server Administrator session does not get
  terminated. This session will be listed in the Session Management
  page until the session time out occurs or DSM SA connection service
  is restarted or the OS is rebooted. The maximum number of Server
  Administrator sessions at a time is configured by "connections"
  entry in "<OpenManageInstallPath>\iws\config\iws.ini" file.

* If a user changes the operating system timezone to a new timezone,
  Server Administrator session management will not display the time
  in the new time zone specified. Server Administrator needs to be
  restarted so that the correct time zone time is displayed in the
  Session Management page.

* Server Administrator Auto Recovery feature may execute configured
  action when system is under heavy stress.

  The Auto Recovery feature can be set to execute an action (e.g.
  reboot system) to recover a hung system.  Since the Auto Recovery
  timer is now an application level timer instead of a kernel level
  timer, heavy resource stress on the system makes it more likely
  that a short keep alive interval (less than 120 seconds) will not
  be measured accurately, and the configured action may be triggered.
  The issue will be more prevalent in systems which has only one CPU,
  Hyper-Threading is not supported or is disabled, and the system is
  subjected to persistent stressful conditions such as resource
  depletion and CPU running at 100% usage with significantly more
  threads than normal usage.

  The Auto Recovery feature is not enabled by default.  If the Auto
  Recovery feature has been enabled, increase the System Reset Timer
  value to at least 120 seconds. [78425]

* Using Internet Explorer browser, if you install Server Administrator
  on a system that includes an underscore in its hostname, you must
  use the target system's ip address in the browser's URL to launch
  Server Administrator as Hostnames with underscores are not supported.
  For example (assuming Server Administrator is listening on
  port 1311):
  https://192.168.2.3:1311.
  For more information, see the following article on the Microsoft
  website:
  http://support.microsoft.com/kb/312461

* If the Alert Log contains large number of entries and if you try
  to navigate to another page, the Server Administrator GUI may
  become unresponsive for approximately 30 seconds. [152755]

* If the CPU throttles, the following message in the hardware System
  Event Log (SEL) will be displayed with an unknown severity:
  System Board Power Optimized: Performance status sensor for System
  Board,unknown event.
  [175331]

* On certain systems that do not support power monitoring, Server
  Administrator reports the two platform event filters related to
  power monitoring as "System Power Probe Warning" and "System Power
  Probe Failure". These two filters are not supported on these
  systems. That is, you can view and configure these filters;
  however no action will be taken. [172125]

* On Server Administrator, Under
  Asset Information->System Information->Primary User Telephone
  Number configuration allows only alphanumerics. [185770]

* While installing Windows Server 2008 or post installation,if you
  set the Time and Currency formats to any of the newly added
  languages (in comparison with Windows Server 2003), then DSM SA
  Connection service and DSM SA Shared Service of Dell OpenManage
  Server Administrator may fail to start and Command Line Interface
  options may fail to execute. [171026]


======================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL MICROSOFT WINDOWS
OPERATING SYSTEMS
======================================================================

* Execute all Server Administrator CLI commands from a 32-bit Windows
  command prompt. Acceptable ways to access the 32-bit command prompt
  are by clicking "Start-> Programs-> Accessories-> Command Prompt"
  or by clicking "Start-> Run" and then typing "cmd.exe". Attempts to
  run the CLI commands from the DOS command "command.com" may generate
  unpredictable results.

* The DSM SA Connection Service might hang on system startup if both
  Oracle and VERITAS(R) Backup Exec(TM) are installed on the system.
  To manually start the DSM SA Connection Service on a system running
  Windows, click "Start-> Programs-> Administrative Tools-> Service",
  right-click "DSM SA Connections Services" and select "Start".

* The Server Administrator might show a blank page after a refresh
  browser by pressing <F5> or by clicking the browser "Refresh" in
  Internet Explorer Version 7.0. This is a known issue and there is
  an article and fix  provided from Microsoft. The Knowledge Base
  article number is KB933006 and  a fix has been provided as security
  update 933566 (MS07-033):Cumulative Security Update for Internet
  Explorer. [165588]

* Users may not get appropriate privileges in Server Administrator
  GUI if
  A) The user is part of an Active Directory group which is in turn
     part of another group and
  B) The user launches Server Administrator using desktop icon and
     Single Sign-on is enabled.
  [167801].


=====================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL LINUX OPERATING
SYSTEMS
=====================================================================
* In case the user belongs to many groups/domains, the login to
  Server Administrator might fail for that user if the installed
  glibc version is not greater than glibc version 2.3.2. [162473]

====================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON MICROSOFT WINDOWS 2003
OPERATING SYSTEMS
====================================================================

* Warning messages ("A provider, omprov, has been registered in the
  WMI namespace, Root\CIMV2\Dell, to use the LocalSystem account.
  This account is privileged and the provider may cause a security
  violation if it does not correctly impersonate user requests")
  may be displayed after installing Server Administrator. These
  messages can be ignored as the Managed Object Format file used to
  register the provider ("omprov") states that the provider only
  reads the inventory data; it does not perform any functions on the
  server that require user impersonation. [139526]

* When running Server Administrator on Windows 2003 Small Business
  Server Edition, the "Export" function will display the export file
  in the browser window, instead of prompting the user to "open" or
  "save" the export file.

* An error message ("The compressed (zipped) folder is invalid or
  corrupted") will be displayed when you perform the following
  actions in Server Administrator on Windows 2003 for x64 systems
  with Internet Explorer 6 SP 1:

  1. Go to System -> Logs

  2. Select "Command," "Alert," or "Hardware."

  3. Click "Save As"

  4. Click "Open" in "File Download" message box.

  Additionally, the "Export" function in the Server Administrator
  GUI may not work. The root cause of both problems is the same.
  To resolve the issue, uncheck "Do not save encrypted pages to
  disk" under Tools-> Internet Options-> Advanced tab. For more
  information, see the following article on the Microsoft website:
  "http://support.microsoft.com/default.aspx?scid=kb;en-us;812935",
  "http://support.microsoft.com/default.aspx?scid=kb;en-us;141582"
  and
  "http://support.microsoft.com/default.aspx?scid=kb;en-us;144876".

* When running Server Administrator, crypt32.dll errors may be
  written to the OS Application Event log. This issue occurs due to
  the "Update Root Certificates" component, which is installed by
  default as part of Windows Server 2003 installation. For more
  information on this component and reasons for errors, see the
  following articles on the Microsoft website:

  "http://www.microsoft.com/technet/prodtechnol/windowsserver2003/
   technologies/security/ws03mngd/04_s3cer.mspx"

  "http://support.microsoft.com/default.aspx?scid=kb;en-us;317541"

  There are two options to avoid these errors from being written to
  the Event log:

  - Uninstall the "Update Root certificates" component as described
    in the first knowledge base article mentioned above.

    Note: This procedure may affect other programs as discussed in
          the article.

  - Install the Server Administrator certificate as a trusted
    certificate.

    Note: This procedure may still prompt you to accept the
          certificate when you log on to Server Administrator, but
          will prevent the crypt32 errors from being logged to the
          Event log.

====================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON MICROSOFT WINDOWS 2008
OPERATING SYSTEMS
====================================================================

* If the Server Administrator is launched using the desktop icon,
  Single Sign-on may not work with Internet Explorer. This occurs
  if the "User Authentication Logon" option is set to "Prompt for user
  name and password" under "Tools" ->
  "Internet Options" -> "Security" -> "Custom Level".[94201]

* Microsoft Windows Server 2008 - Alert Action - Execute Application

  For security reasons, Microsoft Windows Server 2008 is configured
  to not allow interactive services.  When a service is installed
  as an interactive service on Microsoft Windows Server 2008, the
  operating system logs an error message to the Windows System log
  about the service being marked as an interactive service.

  When you use Server Administrator to configure Alert Actions for an
  event, you can specify the action to "execute an application".  In
  order for interactive applications to execute properly for an Alert
  Action, the DSM SA Data Manager service must be configured as an
  interactive service.  Examples of interactive applications are
  applications with a Graphical User Interface (GUI) or that prompt
  the user for input in some way such as the "pause" command in a
  batch file.

  When Server Administrator is installed on Microsoft Windows Server
  2008, the DSM SA Data Manager service is installed as a
  non-interactive service, which means that it is configured to not be
  allowed to interact with the desktop by default.  This means that
  interactive applications will not execute properly when executed
  for an Alert Action.  If an interactive application is executed for
  an Alert Action in this situation, the application will be suspended
  waiting for input from the user, but the application interface/prompt
  will not be visible to the user.  The application interface/prompt
  will not be visible even after the Interactive Services Detection
  service is started.  For each execution of the interactive
  application, there will be an entry for the application process
  in the Processes tab in Task Manager.

  If you need to execute an interactive application for an Alert Action
  on Microsoft Windows Server 2008, you must configure the DSM SA Data
  Manager service to be allowed to interact with the desktop.  To allow
  interaction with the desktop, right-click on the DSM SA Data Manager
  service in the Services control panel and select Properties.  In the
  Log On tab, enable "Allow service to interact with desktop" and
  click OK.  Restart the DSM SA Data Manager service for the change to
  take effect.  When the DSM SA Data Manager service is restarted with
  this change, the Service Control Manager logs the following message
  to the System log: "The DSM SA Data Manager service is marked as an
  interactive service.  However, the system is configured to not allow
  interactive services.  This service may not function properly."
  This change allows the DSM SA Data Manager service to execute
  interactive applications properly for an Alert Action.  Also make
  sure the Interactive Services Detection service is running in order
  to see the interface/prompt displayed by the interactive application.
  Once these changes are made, the "Interactive services dialog
  detection" dialog box will be displayed by the operating system to
  provide access to the interactive application interface/prompt.
  [103661]

  After upgrading Window Server 2003 x64 to Windows Server 2008 x64 with
  OMSA 5.5 installed, the OMSA display does not show all of
  the expected instrumentation pages. The OMSA 5.5 installation must be
  repaired.

  Go to Start>>Settings>>Control panel>>Add Remove Programs
  >>Select "Change"
  on the Dell OpenManage Server Administrator installation and select
  the "Repair" option to correct the issue.

  Note: OMSA 5.3x and earlier must be removed from the operating system
  prior to any upgrades to Windows Server 2008. Only OM 5.4 or later is
  supported for Windows Server 2008. This problem only affects the
  x64 version of the operating system.



=====================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON RED HAT ENTERPRISE LINUX
OPERATING SYSTEMS
=====================================================================

* When starting Server Administrator from the Red Hat Enterprise Linux
  console, kernel log messages may display. To avoid these messages,
  perform the following steps:

  1. Edit the "/etc/sysconfig/syslog" file and modify KLOGD_OPTIONS to
     KLOGD_OPTIONS="-c 4".

  2. Restart "syslog" by executing "/etc/init.d/syslog restart".

* When using the Mozilla browser on Red Hat Enterprise Linux operating
  systems, the font and type size on the Server Administrator global
  navigation bar appear different from the default font and type size
  that Server Administrator uses.

* On systems running Red Hat Enterprise Linux 4 Gold (Intel x86 and
  Intel Extended 64 bit architectures) with DRAC 4 installed, the CD
  device will be listed under a Tertiary Channel instead of the
  Primary Channel. This issue has been resolved in Red Hat Enterprise
  Linux 4 Update 2.

* In the initial release of Red Hat Enterprise Linux 4, the SNMP
  daemon will time-out when walking the network configuration section
  of the MIB II tree on systems running the Intel EM64T operating
  system. This results in missing data while trying to manage this
  server using Dell IT Assistant. This issue can be fixed by updating
  net-snmp-libs-5.1.2-11.EL4.6 found in Red Hat Enterprise Linux 4
  Update 3.

* For systems running a supported Red Hat Enterprise Linux operating
  system, kernel driver messages such as "AAC_ChardevOpen" are
  sometimes displayed in the console at the login prompt. These
  messages, displayed in the console when the driver initialization
  is delayed by the installation of Server Administrator services and
  can be safely ignored.

======================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON SUSE LINUX ENTERPRISE
SERVER OPERATING SYSTEMS
======================================================================

* On systems running SUSE Linux Enterprise Server 9 SP3, an incorrect
  IP address for the system may be displayed in SNMP applications.
  There is a bug in net-snmp 5.1.3.1-0.6 RPM and earlier versions
  where the SNMP daemon provides an incorrect SNMP response to a
  request for a network interface address.
  For example, if a network interface has an IP address of
  192.168.1.1, the SNMP daemon will provide an IP address of
  192.168.1.1.0.0.0.0.
  This may have adverse affects when trying to manage the system and
  may affect Dell IT Assistant operations.

  To avoid this issue, update the net-snmp RPM to version
  5.1.3.1-0.13 or later via YaST Online Update.

* On systems running SUSE Linux Enterprise Server 9 SP3, Server
  Administrator Web interface may freeze when clicking on components
  in the tree view (left pane of the interface).

  To correct this issue, restart the connection service by running

      "srvadmin-services.sh restart" or
      "omconfig system webserver action=restart"

  from the command line. Refresh the web interface and log back into
  Server Administrator to continue.

* On systems running SUSE Linux Enterprise Server 9 SP4 with KDE
  desktop, running Server Administrator storage commands to create
  and delete Virtual Disk continuously might cause KDE Suseplugger
  hang and JRE crash while accessing Server Administrator web interface.

  To recover from this issue, logout and login back to the KDE desktop.
  [242652]
=====================================================================
ISSUES FOR STORAGE MANAGEMENT SERVICE
=====================================================================

The following are open issues regarding the Storage Management
Service.

---------------------------------------------------------------------
STORAGE MANAGEMENT SERVICE ISSUES FOR ALL SUPPORTED OPERATING SYSTEMS
---------------------------------------------------------------------

* When issuing certain "omconfig storage" CLI commands with "Power
  User" privileges, the "Error! User has insufficient privileges to
  run command: omconfig" message may be displayed. You must be logged
  in as an Administrator to perform these actions.

* On a Windows Server 2003 system, it is strongly recommended that
  you update to SP 1 or later.  SP 1 is required
  to fully support SAS technology.

* On a Windows 2000 system, it is strongly recommended that you
  update to SP 4 or later.  SP 4 is required to
  fully support SAS technology.

* On a Red Hat Enterprise Linux 3.x system, Update 3 or later is
  required for Storage Management and Update 7 or later is required
  to fully support SAS technology. It is strongly recommended that
  you use the Red Hat Network (RHN) service to update your system
  software with the latest update package before deploying your
  system. Go to www.redhat.com to access the RHN service and
  download updates.

* Invalid "Format and Check Consistency" options are displayed
  for a regenerating virtual disk. When a physical disk in a virtual
  disk is rebuilding, the virtual disk changes to a "Regenerating"
  state. The Format and Check Consistency operations should not
  be performed on a virtual disk that is in a Regenerating state.
  However, the task drop-down menu for a Regenerating
  RAID 1-concatenated virtual disk may display the "Format and
  Check Consistency" options. Dell is working to resolve this
  problem.

* If a physical disk in a RAID 1-concatenated virtual disk fails, the
  virtual disk is in a "Degraded" state. Rebooting the system may
  cause the virtual disk to change to a "Failed" state yet the
  virtual disk is still fully operational and can be restored to
  "OK" status once a functional physical disk is added back to the
  RAID-1 set. Dell is working to resolve this problem.

* Using the Storage Management Service "Advanced Create VDisk Wizard"
  may occasionally result in a vertical scrollbar of less than
  normal width. If this occurs, resizing the Server Administrator
  window causes the vertical scrollbar to be redrawn correctly.

* Using the GUI, if a virtual disk is renamed to a name containing
  multiple blank and consecutive spaces, the name is truncated to a
  single space after you click "Apply".

* When the "Open in a New Window" option is selected in the Storage
  Management Service Advanced Create VDisk Wizard, the current page
  is opened in a new window, rather than launching the selected
  option.

-----------------------------------------------------------------
STORAGE MANAGEMENT SERVICE ISSUES FOR RED HAT ENTERPRISE LINUX
OPERATING SYSTEMS
-----------------------------------------------------------------

* If a physical disk in a RAID 1-concatenated virtual disk fails,
  the virtual disk is in a Degraded state. The Check Consistency
  operation should not be performed on a virtual disk while it
  is in a degraded state. However, the task drop-down menu
  for a degraded RAID 1-concatenated virtual disk may display the
  "Check Consistency" option. Do not perform a consistency
  check until appropriate actions are performed to restore the
  virtual disk. Dell is working to resolve this problem.

* With Chinese or Japanese language browser settings, using the
  Storage Management Service Advanced Create VDisk Wizard may
  occasionally result in text overflowing to the bottom of the
  side-by-side blue text boxes.

====================================================================
ISSUES FOR REMOTE ACCESS
====================================================================

NOTE: The Remote Access Service is supported on Dell PowerEdge 650,
      700, 750, 800, 830, 840, 850, 860, 1600SC, 1650, 1750, 1800,
      1850, 2600, 2650, 2800, 2850, 4600, 6600, 6650, 6800, 6850,
      6950, 2970, R200, M600, M605, R805, and R900 systems only.

The following subsections list the currently known issues regarding
implementation and operation of your RAC and the Remote Access
Service in Server Administrator.

--------------------------------------------------------------------
ISSUES FOR DRAC 5
--------------------------------------------------------------------
Download the DRAC 5 readme from the Dell support site at
support.dell.com for the latest information on all known issues,
supported web browsers and managed server operating systems.

* DRAC 5 support on SUSE Linux Enterprise Server (version 10) is
  limited to the Manage Node and to the CLI only. DRAC 5 does not
  support the Out of Band GUI on the Management station.

* DRAC 5 GUI supports Mozilla Firefox 1.0.7 only (32-bit)

* DRAC 5 GUI supports only 32-bit browser editions.

--------------------------------------------------------------------
ISSUES FOR DRAC 4
--------------------------------------------------------------------
Download the DRAC 4 readme from support.dell.com for the latest
information on all known issues.

* Perform the following steps if you do not see the "Remote Access
  Controller" properties tab in the Server Administrator user
  interface, after installing it on a system with DRAC 4:

  1. Make sure that the "Remote Access" service is running.

  2. Refresh the Server Administrator user interface.

    If the "Remote Access Controller" properties tab still
    does not appear:

    - Close the Server Administrator  user interface.

    - Restart the "DSM SA Data Manager" service.

    - Restart the "Secure Port Server" service.

    - Open the Server Administrator user interface and log in.

* When connecting to a remote DRAC 4 using a Mozilla Web browser from
  a Linux client, the Virtual Media feature may not be available. The
  browser displays the error: "Virtual Media Plug-in is not installed
  or running". This issue is caused by the new Java applet security
  features of Mozilla 1.7.3 or later. Perform the following steps to
  manually install the plug-in for that specific browser:

  1. Log in to DRAC 4 and navigate to the "Properties" page.

  2. Change the Web address in the browser window from
     "https://<DRAC4-IP-address>/cgi/main" to
     "https://<DRAC4-IP-address>/rac4vm.xpi", and press Enter.

     Mozilla prompts you with an "Opening rac4vm.xpi" dialog,
     allowing you to save the file to your local file system.

  3. Click "OK" and save the file to a temporary location (should
     be your home directory, by default).

  4. Close the browser after saving the file.

  5. Restart the browser, and specify the Web address of the
     "rac4vm.xpi" file (for example:  file:///root/rac4vm.xpi).

  6. Mozilla presents you with the "Software Installation" dialog:
     Click the "Install" button to continue.

  7. After installation completes, close and restart the browser.

  8. Log in to DRAC 4, and navigate to the Virtual Media link.
     The plug-in is installed and ready to use.

  9. At this point, delete the "~/rac4vm.xpi" file.

* The cfgDNSServer1 and cfgDNSServer2 properties of group
  cfgLanNetworking may be set to identical values while swapping
  addresses. Some performance may be lost temporarily during the
  swapping. The cfgLanNetworking group is configured using the
  "racadm config" command.[132894]

--------------------------------------------------------------------
ISSUES FOR DRAC III, DRAC III/XT, ERA, AND ERA/O
--------------------------------------------------------------------
Download the readme for your RAC type from support.dell.com for
the latest information on all known issues.

* Remote Access Dial-Up Settings: If you change a DRAC III modem
  "Dial Mode" setting to "Tone" or "Pulse" using Server Administrator,
  IT Assistant displays the opposite setting.

---------------------------------------------------------------------
ISSUES FOR ALL OPERATING SYSTEMS
---------------------------------------------------------------------

* Server Administrator user interface and commands related to "local
  authentication enable" are not applicable for RAC firmware 3.20.
  The Active Directory authentication feature replaces the "local
  operating system authentication" feature in this version of
  firmware. Due to this change, the following commands will return
  errors:

  "racadm localauthenable"
  "omconfig rac authentication"

* Due to fluctuations in the watchdog timer, the "Last Crash
  Screen" may not be captured when the Automatic System Recovery is
  set to a value of less than 30 seconds. To ensure correct
  functioning of the Last Crash Screen feature, set the System Reset
  Timer to at least 30 seconds.

* The cfgDNSServer1 and cfgDNSServer2 properties of group
  cfgLanNetworking may be set to identical values while swapping
  addresses. Some performance may be lost temporarily during the
  swapping. The cfgLanNetworking group is configured using the
  "racadm config" command.[132894]

* The remote access controller uses FTP protocol to perform some of
  the Dell OpenManage commands. If a firewall is installed in the
  system, it may cause these commands to fail.

  The following Server Administrator CLI commands use FTP protocol
  to communicate with the RAC:

  "omconfig rac uploadcert"
  "omconfig rac generatecert"

  The following racadm commands use FTP protocol to communicate
  with the RAC:

  "racadm sslcertupload"
  "racadm sslcsrgen"
  "racadm fwupdate"

* If the RAC configuration is reset to factory defaults using the
  "racadm racresetcfg" command, the RAC configuration tab in Server
  Administrator does not reflect the reset configuration settings
  until the system reboots. Also, the RAC configuration page in
  Server Administrator cannot be used to make any configuration
  changes until the system reboots.

* The RAC does not support local RAC user IDs with special
  characters. When adding a local RAC user, use only alphanumeric
  characters for the user name.

* While the RAC is being reset, the Instrumentation Service cannot
  read sensor data for certain systems. As a result, the voltage,
  temperature, and other probes may not be visible on the Server
  Administrator home page until the RAC has completed resetting.

* The RAC may not send traps when your system is locked up. To enable
  traps to be sent when the system is locked, configure the watchdog
  timer using the Server Administrator GUI. In the Server
  Administrator GUI, click the "Properties" tab and ensure that
  "Auto Recovery" is selected. The default value of the "Action On
  Hung Operating System Detection" setting is "None". "None"
  indicates that detection will not be performed.

* RAC firmware 2.0 and higher does not support passwords with special
  characters (non-alphanumeric) only for RAC user IDs logging in
  using the Web-based interface (with Local RAC Authentication). If
  you created RAC user IDs using previous versions of the firmware
  or if you created user IDs using Server Administrator that is
  running version 2.0 firmware on the managed system, you cannot log
  in to the RAC.

  Use one of these methods to correct this issue:

  - Change your passwords before updating the firmware.

  OR

  - Use the following CLI command to change the password:

    "omconfig rac users username=xx userpassword=yy"

    where "xx" is the original userid and "yy" is the new password.

  OR

  - Change the password through Server Administrator using the "User"
    tab. Ensure that the check box to change the password is checked.
    Enter a new password, and then enter it again to validate the
    change.

  OR

  - Use the racadm utility to change the password:

    "racadm config -g cfgUserAdmin -o cfgUserAdminPassword
    -i <usr_index> <new_pwd>"

    where <usr_index> is the index of the user database entry to be
    modified and <new_pwd> is the new password.

* Depending on your network and proxy configurations and whether you
  are using Mozilla browser, you may need to
  enter the exact IP address of the RAC controller you are trying to
  access in the "No Proxy for" field of your browser.

  Perform the following steps:

  1. Open your Mozilla browser.

  2. Click "Edit".

  3. Click "Preferences ...".

  4. Click "Advanced" in the left sidebar.

  5. Click "Proxies" in the left sidebar.

  6. Enter the RAC IP address in the "No Proxy for:" field.

  7. Click "OK" and then close the browser.

* If the out-of-band RAC user interface was spawned off from the
  Server Administrator home page with a Mozilla browser, strings with
  extended ASCII characters may not display correctly in certain
  languages. This issue occurs because the browser is set to the
  UTF-8 character set by Server Administrator. To correct this issue,
  change the browser character coding to ISO-8859-1. For Japanese
  and Chinese, UTF-8 is the correct encoding for RAC pages.

* To view the RAC Web-based interface when using Mozilla 1.6, you
  must configure your cookie settings to "Enable all cookies".

  To enable all cookies, go to the menu options and click
  "Edit -> Preferences -> Privacy & Security -> Cookies", and then
  select "Enable all cookies". If you do not perform these steps,
  you will not be able to log in to the Web interface and you will
  receive a message that your username and password are incorrect.

---------------------------------------------------------------------
DRAC III ISSUES FOR WINDOWS OPERATING SYSTEMS
---------------------------------------------------------------------

* A dial-up network connection to the remote access controller is
  established by the RAC managed system software installer. The RAC
  software will not work if this dial-up connection is deleted or if
  a proxy is set up in the Internet settings. An InstallPPP utility
  is provided with the RAC software to restore the RAC PPP
  connection. This utility can also correct Internet connection
  problems with proxy server settings, when using the Windows 2003
  operating system. You can run the utility from the Windows command
  prompt with the argument "CreateRACConnection" as shown below:

  c:\>installPPP CreateRACConnection

* Applications that use InstallShield 3.x to install software may
  take longer to install if RAC Services are running. To reduce the
  software installation time, stop RAC Services before performing the
  installation. Restart RAC Services after the installation is
  complete.

* Due to functional details that are specific to Windows Dynamic DNS
  servers, the RAC internal PPP IP address is broadcast to the
  Dynamic DNS service on servers running Windows. The Dynamic DNS
  service stores that particular IP address in its DNS look-up table
  and associates it with the name of the system that hosts the RAC.
  This action causes problems with Active Directory under Windows.
  The default value for a RAC's internal PPP IP address is
  192.168.234.235, but the address can be changed by the user. This
  issue is a known problem, and there is an article and a hot fix
  available from Microsoft. The Knowledge Base article number is
  Q292822. Downloading the hot fix and implementing the steps in the
  article will solve the problem.

* If you have used the "Systems Management Consoles" CD version 3.1,
  or earlier, to install RAC management station software on any
  system running a Windows operating system, you must remove any
  previous versions of the RAC management station software before
  installing a later version of the RAC management station software.

  To remove the RAC management station software on Windows, perform
  the following steps:

  1. Insert the "Dell Systems Management Tools and Documentation" DVD
     into the DVD drive.

  2. When the installation application starts, click "Exit".

  3. Open a command shell window:

     a. Click the "Start" button, and then click "Run".

     b. In the "Run" dialog box, type the following command and then
        press <Enter>:

        cmd

  4. Start the Install Shield uninstallation program to remove
     software:

     a. In the command shell window, type the following line
        (replacing x: with the actual drive letter of your DVD drive,
        such as d:):

        x:\rac20\mtpkg\setup.exe

     b. Select "Remove", and then click "Next".

     c. Click "OK".

     d. Click "Finish".

  5. Close the command shell window.

* On systems running Windows, the RAC installation process requires a
  virtual modem connection named RACPORT to communicate between the
  operating system and the RAC. When any modem is added to the system,
  the operating system automatically creates a virtual fax
  device icon in the printers folder. The fax icon is not used by the
  RAC and can be deleted or ignored.

* The mouse movement on a local Windows system may appear jerky
  and erratic during DRAC III console redirection. This behavior
  is evident especially when using menus or opening windows.

* Resizing the Windows desktop to a resolution of 640 x 480 causes
  some information to not be visible in the browser window when using
  the RAC Web-based interface. This issue occurs in Internet Explorer.
  To view a screen in its entirety when using a resolution
  of 640 x 480, you must enlarge the browser window.

* While installing applications such as SQL Server 2000,if the RAC
  device (PCI Function 0, PCI Function 2 and RAC Virtual
  UART Port) is disabled and the RAC service is running, you may
  experience problems such as an application hang. To successfully
  install these applications you can either re-enable the driver or
  you can stop the service.[129915]

---------------------------------------------------------------------
DRAC III ISSUES FOR RED HAT ENTERPRISE LINUX OPERATING SYSTEMS
---------------------------------------------------------------------

* While installing the Dell OpenManage systems management applications
  through the Nautilus File Manager, you must use the "Run" button
  and not the "Run In Terminal" button after choosing the "start.sh"
  script from the File Manager's file list. Use the "Run In Terminal"
  button for applications that do not open a window of their own (the
  "start.sh" script opens its own window). If you choose "Run In
  Terminal", you must restart the racvnc service after installing
  Dell OpenManage systems management applications by typing the
  following command:

  "service racvnc restart"

* When using Console Redirection on a managed system running Red Hat
  Enterprise Linux, the focus (cursor moved back over an object)
  follows the cursor. Occasionally, the text window in Console
  Redirection lose focus. Before attempting to type in a text window
  in a Console Redirection window, click the mouse in the text
  window's spacebar or top menu bar to ensure that your target text
  window has the focus on the correct window or application that you
  are attempting to use.


####################################################################

Information in this document is subject to change without notice.
(C) 2008 Dell Inc. All rights reserved.

Reproduction in any manner whatsoever without the written permission
of Dell Inc. is strictly forbidden.

Trademarks used in this text: "Dell", "PowerEdge", "PowerVault", and
"Dell OpenManage" are trademarks of Dell Inc.; "Intel" is a
registered trademark of Intel Corporation; "Microsoft",
"Windows Server", and "Windows NT" are registered trademarks of
Microsoft Corporation and/or other countries; "Red Hat" is a
registered trademark of Red Hat, Inc.; "SUSE" is a registered
trademark of Novell Inc.; "EMC" and "Navisphere" are registered
trademarks of EMC Corporation; "VERITAS" is a registered trademark
and "Backup Exec" is a trademark of VERITAS Software Corporation;
Adaptec is a registered trademark of Adaptec, Inc. VMware is a
trademark and ESX Server is a trademark of VMware Inc.; Citrix is
either a registered trademark or trademark of Citrix Systems, Inc.
in the United States and/or other countries.;Firefox is a registered
trademark of Mozilla.;Hyper-V is either a trademark or registered
trademark of Microsoft Corporation in the United States and/or other
countries.

Server Administrator uses the OverLIB JavaScript library. This
library can be obtained from "http://www.bosrup.com/web/overlib/".

Other trademarks and trade names may be used in this document to
refer to either the entities claiming the marks and names or their
products. Dell Inc. disclaims any proprietary interest in
trademarks and trade names other than its own.

August 2008