DELL(TM) OPENMANAGE(TM) Server Administrator Storage Management,
VERSION 2.2 README

This is the readme file for the Dell OpenManage Server Administrator
Storage Management Service. For additional information, see the
ServerAdministrator readme file and the Server Administrator User's
Guide.

Note: The Storage Management service is installed using the
      Server Administrator installation process. See the Dell
      OpenManage Install readme (readme_ins.txt) on the "Systems
      Management" CD for the latest installation information.

Note: Installing the Storage Management on a system that does
      not have a supported controller or that has a controller that
      is not attached to storage is an unsupported configuration.
      Attempts to install or run Storage Management using an
      unsupported configuration can result in unexpected and
      undesirable system behavior.

Note: Starting with Dell OpenManage 5.0, Array Manager is no longer
      an installable option. If you have an Array Manager installation
      and need information on how to migrate from Array Manager to
      Storage Management, refer to the product documentation prior to
      Storage Management 2.1 or Dell OpenManage 5.1.

Always see the Dell support Website at support.dell.com for the most
current information.

#######################################################################

======================================================================
Criticality
======================================================================

2 - Recommended


Note: The Storage Management service does not support Novell(R)
      NetWare(R) or fibre channel. Disk and volume management are
      also not provided by the Storage Management service.

======================================================================
Title and Description
======================================================================

Dell OpenManage Server Administrator Storage Management is a storage
management application for PowerEdge(TM) servers that provides
enhanced features for configuring a system's locally-attached RAID
and non-RAID disk storage. Dell OpenManage Server Administrator
Storage Management enables you to perform controller and enclosure
functions for all supported RAID and non-RAID controllers and
enclosures from a single graphical or command-line interface without
requiring the use of the controller BIOS utilities. The graphical
user interface (GUI) is wizard-driven with features for novice and
advanced users and detailed online help. The command line interface
is fully-featured and scriptable.

The Storage Management service supports SCSI, SATA, ATA and SAS
technologies.

######################################################################
README TABLE OF CONTENTS
######################################################################

COMPATIBILITY/RECOMMENDED REQUIREMENTS
WARNINGS
WHAT IS NEW IN THIS RELEASE?
INSTALLING STORAGE MANAGEMENT, VERSION 2.2
KNOWN LIMITATIONS

######################################################################
COMPATIBILITY/RECOMMENDED REQUIREMENTS
######################################################################

The Storage Management service is installed using the Server
Administrator install process. For Server Administrator installation
requirements, see the following documentation:

* The Dell OpenManage Install readme (readme_ins.txt) on the
  "Installation and Server Management" CD for the latest
  installation information.

* The "Installing Server Administrator" chapter in the Server
  Administrator User's Guide.


In addition to the Server Administrator installation requirements,
the following requirements apply to Storage Management. Storage
Management may experience instability if these requirements are
not met.

* Windows Server(R) 2003 with Service Pack 1 or later.
  Service Pack 1 is required to support SAS technology.

* Windows(R) 2000 32-bit with Service Pack 4 or later.
  Service Pack 4 is required to support SAS technology. Windows
  2000 64-bit is not supported.

* Red Hat(R) Enterprise Linux 3.x. Update 3 or later is required
  for Storage Management and Update 7 or later is required to
  support SAS technology.  Dell strongly recommends that you use
  the Red Hat Network (RHN) service to update your system software
  with the latest update package before deploying your system. Go
  to www.redhat.com to access the RHN service and download updates.

* SUSE Linux Enterprise Server 9 for Intel EM64T with
  Service Pack 3 or later. Service Pack 3 is required to support
  SAS technology.

======================================================================
COMPATIBILITY WITH OTHER RAID STORAGE MANAGEMENT UTILITIES
======================================================================

* PERC Console and FAST Compatibility Issues when Installing Storage
  Management

  Installing Storage Management on a system that has FAST or the
  PERC Console installed is an unsupported configuration. It is
  recommended that you uninstall FAST and the PERC Console before
  installing Storage Management. In particular, you may find that
  Storage Management or the FAST features are disabled at run time
  when using Storage Management on a system that also has FAST
  installed. Storage Management replaces all storage management
  features provided by FAST and the PERC Console. In addition,
  Storage Management has features not provided by FAST and the PERC
  Console.


* Compatibility with Linux Utilities

  Installing Storage Management on a Linux system that has other
  RAID storage management utilities provided by Dell or other
  vendors is an unsupported configuration. It is recommended that
  you uninstall these utilities before installing Storage
  Management. Storage Management replaces the storage management
  features provided by these utilities. Examples of the Dell or
  vendor-supplied Linux utilities include:

  - LinFlash
  - DellMgr
  - DellMON
  - LINLib
  - MegaMgr
  - MegaMON


Note: These utilites are only applicable to the following controllers:
      PERC 3/SC, 3/DC, 3/DCL, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM,
      4e/Si, 4e/Di.

      See the WARNINGS section of this readme for additional
      information.


======================================================================
FIRMWARE AND DRIVER REQUIREMENTS FOR THE PERC 3/SC, 3/DC, 3/DCL, 3/QC,
4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch,
PERC 5/E, PERC 5/i Integrated, PERC 5/i Adapter, SAS 5/iR Integrated,
SAS 5/iR Adapter, SAS 5/i Integrated, SAS 5/E Adapter, LSI 1020,
and LSI 1030 CONTROLLERS
======================================================================

The firmware and drivers listed in the following table refer to the
minimum supported version. Later versions of the firmware and drivers
are also supported. Refer to http://support.dell.com for the most
recent driver and firmware requirements.


*** Firmware  for PERC 3/SC, 3/DC, 3/DCL, 3/QC, 4/SC, 4/DC, 4e/DC,
4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch, PERC 5/E, PERC 5/i
Integrated, PERC 5/i Adapter, SAS 5/iR Integrated, SAS 5/iR
Adapter, SAS 5/i Integrated, SAS 5/E Adapter, LSI 1020,
and LSI 1030 Controllers ***

------------------------------
| Controller  | Firmware/    |
|             | BIOS         |
|             |              |
|             |              |
------------------------------
| PERC 3/SC   | 1.99A        |
|             |              |
|             |              |
------------------------------
| PERC 3/DC   | 1.99A        |
|             |              |
|             |              |
------------------------------
| PERC 3/DCL  | 1.99A        |
|             |              |
|             |              |
------------------------------
| PERC 3/QC   | 1.99A        |
|             |              |
|             |              |
------------------------------
| PERC 4/SC   | 3.52B        |
|             |              |
|             |              |
------------------------------
| PERC 4/DC   | 3.52B        |
|             |              |
|             |              |
------------------------------
| PERC 4e/DC  | 5.22A        |
|             |              |
|             |              |
------------------------------
| PERC 4e/Si  | 5.22A        |
|             |              |
|             |              |
------------------------------
| PERC 4e/Di  | 5.22A        |
|             |              |
|             |              |
------------------------------
| PERC 4/Di   | 2.52A        |
| on a        |              |
| PowerEdge   |              |
| 2600        |              |
------------------------------
| PERC 4/Di   | 4.22A        |
| on a        |              |
| PowerEdge   |              |
| 1750        |              |
------------------------------
| PERC 4/IM   | 1.00.12.00   |
| on a        | (1.00.0C.00  |
| PowerEdge   |  Hex)        |
| 1655MC      |              |
------------------------------
| PERC 4/IM   | 1.03.23.90   |
| on a        |              |
| PowerEdge   |              |
| 1855        |              |
------------------------------
| CERC        | 6.62         |
| ATA 100/4CH |              |
|             |              |
------------------------------
| PERC 5/E    | 5.1.1-0033   |
|             |              |
|             |              |
------------------------------
| PERC 5/i    | 5.1.1-0033   |
| Integrated  |              |
|             |              |
------------------------------
| PERC 5/i    | 5.1.1-0033   |
| Adapter     |              |
|             |              |
------------------------------
| SAS 5/iR    | 00.10.49.00/ |
| Integrated  | 06.12.02.00  |
|             |              |
------------------------------
| SAS 5/iR    | 00.10.49.00/ |
| Adapter     | 06.12.02.00  |
|             |              |
------------------------------
| SAS 5/i     | 00.10.49.00/ |
| Integrated  | 06.12.02.00  |
|             |              |
------------------------------
| SAS 5/E     | 00.10.49.00/ |
| Adapter     | 06.12.02.00  |
|             |              |
------------------------------
| LSI 1020 on | 1.03.23      |
| a PowerEdge |              |
| 1600SC      |              |
------------------------------
| LSI 1030 on | 1.03.23      |
| a PowerEdge |              |
| 1750        |              |
------------------------------



*** Windows Drivers for PERC 3/SC, 3/DC, 3/DCL, 3/QC,
4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch,
PERC 5/E, PERC 5/i Integrated, PERC 5/i Adapter, SAS 5/iR
Integrated, SAS 5/iR Adapter, SAS 5/i Integrated, SAS 5/E
Adapter, LSI 1020, and LSI 1030 Controllers ***

----------------------------------------------------------
| Controller  | Windows     | Windows     | Windows      |
|             | 2000        | Server      | Server       |
|             | 32-bit      | 2003        | 2003         |
|             | Driver      | 32-bit      | 64-bit       |
|             |             | Driver      | Driver       |
----------------------------------------------------------
| PERC 3/SC   | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 3/DC   | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 3/DCL  | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 3/QC   | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4/SC   | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4/DC   | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4e/DC  | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4e/Si  | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4e/Di  | 5.48        | 6.46.2.32   | 6.46.3.64    |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    |
| on a        |             |             |              |
| PowerEdge   |             |             |              |
| 2600        |             |             |              |
----------------------------------------------------------
| PERC 4/Di   | 5.48        | 6.46.2.32   | 6.46.3.64    |
| on a        |             |             |              |
| PowerEdge   |             |             |              |
| 1750        |             |             |              |
----------------------------------------------------------
| PERC 4/IM   | 1.08.06     | Native      | Not          |
| on a        |             |             | Applicable   |
| PowerEdge   |             |             |              |
| 1655MC      |             |             |              |
----------------------------------------------------------
| PERC 4/IM   | 1.09.11     | 1.09.11     | Native (SP1) |
| on a        |             |             | 1.09.11.53   |
| PowerEdge   |             |             |              |
| 1855        |             |             |              |
----------------------------------------------------------
| CERC        | 5.46        | 6.41.2.32   | Not          |
| ATA 100/4CH |             |             | Applicable   |
|             |             |             |              |
----------------------------------------------------------
| PERC 5/E    | 2.08.00.32  | 2.08.00.32  | 2.08.00.64   |
|             |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 5/i    | 2.08.00.32  | 2.08.00.32  | 2.08.00.64   |
| Integrated  |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| PERC 5/i    | 2.08.00.32  | 2.08.00.32  | 2.08.00.64   |
| Adapter     |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| SAS 5/iR    | 1.24.03.00  | 1.24.03.00  | 1.24.03.00   |
| Integrated  |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| SAS 5/iR    | 1.24.03.00  | 1.24.03.00  | 1.24.03.00   |
| Adapter     |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| SAS 5/i     | 1.24.03.00  | 1.24.03.00  | 1.24.03.00   |
| Integrated  |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| SAS 5/E     | 1.24.03.00  | 1.24.03.00  | 1.24.03.00   |
| Adapter     |             |             |              |
|             |             |             |              |
----------------------------------------------------------
| LSI 1020 on | 1.09.11.00  | 1.09.11.00  | Not          |
| a PowerEdge |             |             | Applicable   |
| 1600SC      |             |             |              |
----------------------------------------------------------
| LSI 1030 on | 1.09.11.00  | 1.09.11.00  | Not          |
| a PowerEdge |             |             | Applicable   |
| 1750        |             |             |              |
----------------------------------------------------------



*** Linux Drivers for PERC 3/SC, 3/DC, 3/DCL, 3/QC,
4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, CERC ATA100/4ch,
PERC 5/E, PERC 5/i Integrated, PERC 5/i Adapter, SAS 5/iR
Integrated, SAS 5/iR Adapter, SAS 5/i Integrated, SAS 5/E
Adapter, LSI 1020, and LSI 1030 Controllers ***

-------------------------------------------------------------------------------------
| Controller  | Redhat      | Redhat      | SUSE        | SUSE        | Redhat      |
|             | Linux       | Linux       | Linux       | Linux       | Linux       |
|             | Driver      | Driver      | 9 64-Bit    | 10 64-bit   | Driver      |
|             | 3.0         | 4.0         | Driver      | Driver      | 5.0         |
-------------------------------------------------------------------------------------
| PERC 3/SC   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 3/DC   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 3/DCL  | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 3/QC   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/SC   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/DC   | 2.10.10.1   | 2.20.4.4    | Native      | Native      | Native      |
|             |             |             | 2.20.4.6    | 2.20.4.7    | 2.20.5.1    |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4e/DC  | 2.10.10.1   | 2.20.4.4    | Native      | Native      | Native      |
|             |             |             | 2.20.4.6    | 2.20.4.7    | 2.20.5.1    |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4e/Si  | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4e/Di  | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
|             |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/Di   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
| on a        |             |             | Applicable  | Applicable  | Applicable  |
| PowerEdge   |             |             |             |             |             |
| 2800        |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/Di   | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
| on a        |             |             | Applicable  | Applicable  | Applicable  |
| PowerEdge   |             |             |             |             |             |
| 1750        |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/IM   | Not         | Not         | Not         | Not         | Not         |
| on a        | Applicable  | Applicable  | Applicable  | Applicable  | Applicable  |
| PowerEdge   |             |             |             |             |             |
| 1655MC      |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 4/IM   | 2.05.16     | Native      | Not         | Not         | Not         |
| on a        |             | 3.01.16     | Applicable  | Applicable  | Applicable  |
| PowerEdge   |             |             |             |             |             |
| 1855        |             |             |             |             |             |
-------------------------------------------------------------------------------------
| CERC        | 2.10.10.1   | 2.20.4.4    | Not         | Not         | Not         |
| ATA 100/4CH |             |             | Applicable  | Applicable  | Applicable  |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 5/E    | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 |
|             |             |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 5/i    | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 |
| Integrated  |             |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| PERC 5/i    | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 | 00.00.03.06 |
| Adapter     |             |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| SAS 5/iR    | 2.06.48.02  | 3.02.83.12  | 3.02.83.12  | 4.00.00.00  | 4.00.00.00  |
| Integrated  | (64-bit)    |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| SAS 5/iR    | 2.06.48.02  | 3.02.83.12  | 3.02.83.12  | 4.00.00.00  | 4.00.00.00  |
| Adapter     | (64-bit)    |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| SAS 5/i     | 2.06.48.02  | 3.02.83.12  | 3.02.83.12  | 4.00.00.00  | 4.00.00.00  |
| Integrated  | (64-bit)    |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| SAS 5/E     | 2.06.48.02  | 3.02.83.12  | 3.02.83.12  | 4.00.00.00  | 4.00.00.00  |
| Adapter     | (64-bit)    |             |             |             |             |
|             |             |             |             |             |             |
-------------------------------------------------------------------------------------
| LSI 1020 on | 2.05.11.03  | Native      | Not         | Not         | Not         |
| a PowerEdge |             |             | Applicable  | Applicable  | Applicable  |
| 1600SC      |             |             |             |             |             |
-------------------------------------------------------------------------------------
| LSI 1030 on | 2.05.11.03  | Native      | Not         | Not         | Not         |
| a PowerEdge |             |             | Applicable  | Applicable  | Applicable  |
| 1750        |             |             |             |             |             |
-------------------------------------------------------------------------------------



======================================================================
FIRMWARE AND DRIVER REQUIREMENTS FOR THE PERC 3/Si, PERC 3/Di,
CERC SATA1.5/6ch, and CERC SATA1.5/2s CONTROLLERS
======================================================================

The firmware and drivers listed in the following table refer to the
minimum supported version. Later versions of the firmware and drivers
are also supported. Refer to http://support.dell.com for the most
recent driver and firmware requirements.

Note: Versions of these controllers (PERC 3/Si, PERC 3/Di,
      CERC SATA1.5/6ch, and CERC SATA1.5/2s) prior to 2.8
      are not supported.


Note: Storage Management requires that the system be rebooted before
      Storage Management can properly determine whether the system
      meets the firmware and driver requirements for the PERC 3/Si,
      and PERC 3/Di controllers. For this reason, it is possible to
      complete an initial installation of Storage Management without
      being notified whether your system meets the firmware and
      driver requirements. Refer to this readme and
      http://support.dell.com for the most recent driver and
      firmware requirements.



*** Firmware for PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and
CERC SATA1.5/2s Controllers ***

----------------------------
| Controller  | Firmware   |
----------------------------
| PERC 3/Si   | 2.8.1.6098 |
|             |            |
----------------------------
| PERC 3/Di   | 2.8.1.6098 |
|             |            |
----------------------------
| CERC        | 4.1.0.7417 |
| SATA1.5/6ch |            |
----------------------------
| CERC        | Not        |
| SATA1.5/2s  | Applicable |
----------------------------

*** Windows Drivers for PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and
CERC SATA1.5/2s Controllers ***

--------------------------------------------------------
| Controller  | Windows     | Windows     | Windows    |
|             | 2000        | Server      | Server     |
|             | Driver      | 2003        | 2003       |
|             |             | 32-bit      | 64-bit     |
|             |             | Driver      | Driver     |
--------------------------------------------------------
| PERC 3/Si   | 2.8.0.6085* | 2.8.0.6085* | Not        |
|             |             |             | Applicable |
--------------------------------------------------------
| PERC 3/Di   | 2.8.0.6085* | 2.8.0.6085* | Not        |
|             |             |             | Applicable |
--------------------------------------------------------
| CERC        | 4.1.0.7010  | 4.1.0.7010  | 4.1.1.7038 |
| SATA1.5/6ch |             |             |            |
--------------------------------------------------------
| CERC        | 6.0.0.50    | 6.0.0.50    | 6.0.3643.4 |
| SATA1.5/2s  |             |             |            |
--------------------------------------------------------

Note: * The 2.8.0.6085 driver install package for the PERC 3/Si,
        and 3/Di controllers contains the 2.8.0.6076 driver.
        For this driver, Storage Management displays 2.8.0.6076
        whereas Windows Device Manager displays 2.8.0.6085.



*** Linux Drivers for PERC 3/Si, PERC 3/Di, CERC SATA1.5/6ch, and
CERC SATA1.5/2s Controllers ***

---------------------------------------------------------------------------------------
| Controller  | Redhat     | Redhat       |  SUSE      | SUSE       | Redhat          |
|             | Linux      | Linux        |  Linux     | Linux      | Linux           |
|             | Driver     | Driver       |  9 64-Bit  | 10 64-bit  | Driver          |
|             | 3.0        | 4.0          |  Driver    | Driver     | 5.0             |
---------------------------------------------------------------------------------------
| PERC 3/Si   | 1.1.4**    | Not          | Not        | Not        | Not             |
|             |            | Applicable   | Applicable | Applicable | Applicable      |
---------------------------------------------------------------------------------------
| PERC 3/Di   | 1.1.4*     | 1.1.5.2392   | Not        | Not        | Not             |
|             |            |              | Applicable | Applicable | Applicable      |
---------------------------------------------------------------------------------------
| CERC        | 1.1.5.2372 | 1.1.5.2392   | Not        | Not        | Native          |
| SATA1.5/6ch |            |              | Applicable | Applicable | 1.1-5[2409]-mh2 |
---------------------------------------------------------------------------------------
| CERC        | 1.1.5.2372 | 1.1.5.2392   | Not        | Not        | Not             |
| SATA1.5/2s  |            |              | Applicable | Applicable | Applicable      |
---------------------------------------------------------------------------------------

Note:** The 1.1.4 Linux driver is included in RPM 2302
	(Release Package Manager 2302)

======================================================================
ADAPTEC NON-RAID ULTRA SCSI CONTROLLER CARDS
======================================================================

The Ultra SCSI controller cards (non-RAID SCSI) include Ultra SCSI,
Ultra2 SCSI, Ultra160 SCSI, Ultra320 SCSI.

Support for the Ultra SCSI controller cards is provided in the BIOS.


======================================================================
PREREQUISITE DRIVERS AND FIRMWARE ON LINUX
======================================================================

On Linux, Storage Management installation is unable to detect whether
the drivers and firmware on the system are at the required level for
installing and using Storage Management. When installing on Linux,
you will be able to complete the installation regardless of whether
the driver and firmware version meets the required level. Even though
you have completed the installation, installing on a system that does
not meet the driver and firmware version requirements is an
unsupported configuration. In particular, you may find that
controllers and their features are not displayed by Storage
Management on a system that does not meet the driver and firmware
requirements. At Storage Management runtime, you can determine
whether the system meets the firmware requirements by checking your
application log files for notifications on outdated firmware. On SCSI
controllers, Storage Management displays the firmware version at
runtime. On SAS controllers, Storage Management displays both the
firmware and the driver version at runtime.

######################################################################
WARNINGS
######################################################################

* As a general rule, you should use only one RAID utility to
  configure and manage storage. Installing the Storage Management
  service on a system that has native RAID utilities or RAID
  utilities provided by Dell or other vendors is an unsupported
  configuration.

* The Storage Management service enables you to perform storage
  tasks that are data-destructive. The Storage Management service
  should be used by experienced storage administrators who are
  familiar with their storage environment.

######################################################################
WHAT IS NEW IN THIS RELEASE?
######################################################################

This release of Storage Management provides various functional
improvements. You may want to be aware of the following changes:

* This release of Storage Management provides an Import/Recover Foreign
  Configuration task. The Import/Recover Foreign Configuration task
  imports foreign virtual disks and attempts to recover virtual disks
  that are in a failed or degraded state.  Either the Import/Recover
  Foreign Configuration option or the Import Foreign Configuration
  option will appear as specificed by the information provided by the
  Firmware API.

* When creating a virtual disk with the Create Virtual Disk Express
  or Advanced wizards, it is now possible to assign a hot spare to
  the virtual disk using the Express or Advanced wizard.

* The Storage Management graphical user interface (GUI) and command
  line interface (CLI) display the enable/disable status for the
  Patrol Read task.

* This release of Storage Management contains enhancements that avoid
  numerous redundant or inappropriate alerts posted to the Alert Log
  after an unexpected system shutdown.

* RAID 1-concatenated creation is no longer supported on the PERC 3/Si,
  3/Di, and CERC SATA1.5/6ch controllers.

* The "Execute" link that was avaliable next to avaliable tasks is now
  an "Execute" button.

* Added support for Red Hat(R) Enterprise Linux (version 5)on Intel x86
  and Intel Extended Memory 64 Technology (EM64T) systems.

######################################################################
INSTALLING STORAGE MANAGEMENT, VERSION 2.2
######################################################################

The Storage Management service is installed using the Server
Administrator install process. For Server Administrator installation
requirements, see the following documentation:

* The Dell OpenManage Install readme (readme_ins.txt) on the
  "Systems Management" CD for the latest installation information.

* The "Installing Server Administrator" chapter in the Server
  Administrator User's Guide.


Note: You cannot reinstall Storage Management on a system that
      already has Storage Management installed. If you need to
      reinstall Storage Management, you must first uninstall the
      existing installation using the Server Administrator uninstall
      process.


Note: Installing Storage Management on a system that does not have a
      supported controller or that has a controller that is not
      attached to storage is an unsupported configuration. Attempts
      to install or run Storage Management using an unsupported
      configuration can result in unexpected and undesirable system
      behavior.


######################################################################
KNOWN LIMITATIONS
######################################################################

The following sections describe known problems associated with
Storage Management or the supported controllers. Dell is in the
process of resolving these problems.


* Incompatible physical disks attached to a SAS 5/iR controller may
  not display correct physical disk IDs in the Storage Management
  user interface.  (75371)

  Problem: You may notice that Storage Management reports incorrect
  physical disk IDs after attaching an incompatible physical disk
  to a SAS 5/iR controller. A physical disk is incompatible if it is
  too small for the existing virtual disk configuration or if it is
  using an incompatible technology. For example, if a virtual disk
  is using SAS physical disks, then a SATA physical disk is
  incompatible.

  If the Storage Management service is running and you insert an
  incompatible physical disk, Storage Management assumes the disk
  is using SCSI technology and reports the disk ID in a 0:0 format.
  The physical disk ID for SAS and SATA disks is normally in a 0:0:0
  format when the physical disks are connected to the SAS 5/iR
  controller through a backplane.

  If the Storage Management service is restarted after you insert
  an incompatible physical disk, then Storage Management does not
  display the physical disk at all.

  This behavior applies to the Storage Management graphical and
  command line interfaces.

  Solution: Inserting a physical disk that is incompatible is an
  unsupported configuration. When inserting or replacing a
  physical disk, make sure the new disk meets the size and
  technology requirements.

* Storage Management responds slowly when using Internet
  Explorer 6.x on a system with mixed SAS and SATA physical disks.
  (60696)

  Problem:  When using the Create Virtual Disk wizard from the
  Storage Management graphical user interface (GUI), you may notice
  decreased performance when using Internet Explorer 6.x on a system
  with multiple Dell PowerVault MD1000 storage enclosures that are
  heavily populated with mixed SAS and SATA physical disks.

  Solution: Use a supported browser other than Internet Explorer 6.x
  or use the Storage Management command line interface (CLI) to
  create the virtual disk. See the Dell OpenManage Server
  Administrator readme for information on supported browsers. See
  the Storage Management online help or the "Dell OpenManage Server
  Administrator Command Line Interface User's Guide" for information
  on using the Storage Management CLI.

* The system may require an extended period of time to boot when a
  tape device without a driver is attached. (35823)

  Problem:  Storage Management performs a discovery process for
  all attached devices when the system boots. The discovery process
  may take an extended period of time if the system has a tape
  device with no driver or an unsupported driver attached. When this
  occurs, the system requires a period of time in excess of ten
  minutes to complete the boot process.

  Solution: Either detach the tape device from the system or
  install a supported version of the tape driver.

* Storage Management may not display controllers installed with
  the Dell OpenManage Service and Diagnostics utility. (152362)

  Problem: Storage Management may not recognize devices that are
  installed after Storage Management is already running.

  Solution: If Storage Management does not recognize a newly
  added device and this problem has not been corrected with a
  Global Rescan, then reboot the system.

* Storage Management SNMP traps are not filtered by Server
  Administrator. (120475)

  Problem: Server Administrator allows you to filter SNMP traps that
  you do not wish to receive. To implement SNMP trap filtering,
  select the System tree object and then select the Alert Management
  tab and the SNMP Traps subtab. The SNMP Traps subtab has options
  for enabling or disabling SNMP traps based on severity or the
  component that generates the trap. Even when the SNMP traps are
  disabled, Storage Management will generate SNMP traps.

  Solution: SNMP trap filtering will be provided in a future release
  of Storage Management.


######################################################################

Information in this document is subject to change without notice.
(C) 2007 Dell Inc. All rights reserved.

Reproduction in any manner whatsoever without the written
permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: "Dell", "PowerEdge", "PowerVault",
and "Dell OpenManage" are trademarks of Dell Inc.; "Microsoft",
"Windows", and "Windows Server" are registered trademarks of
Microsoft Corporation; "SUSE", "Novell", and "NetWare" are registered
trademarks of Novell, Inc.; "Red Hat" is a registered trademark of
Red Hat, Inc.

Other trademarks and trade names may be used in this document to
refer to either the entities claiming the marks and names or their
products. Dell Inc. disclaims any proprietary interest in trademarks
and trade names other than its own.

February 2007

DELL OPENMANAGE(TM) Server Administrator Storage Management,
VERSION 2.2 README