# S020SMPL.cfg: Controls Sampling # $Id: S020SMPL.cfg,v 2.6 2012/01/02 17:25:16 mschenke Exp $ # ARCS: $Header: /home/cvs/cvs/RDA_4/src/scripting/lib/modules/S020SMPL.cfg,v 2.6 2012/01/02 17:25:16 mschenke Exp $ # # Copyright (c) 2002, 2012, Oracle and/or its affiliates. All rights reserved. # # Change history # 20120102 MSC Change the copyright notice. ############################################################################### # Collect sampling setup information ############################################################################### #------------------------------------------------------------------------------ # Module definition #------------------------------------------------------------------------------ dsc="Controls Sampling" req=S000INI var=SMPL_DELTA,SMPL_MODULES,SMPL_SLEEP,SMPL_KEEP,SMPL_LAST,SMPL_RATE,SMPL_SIZE #------------------------------------------------------------------------------ # Sampling control #------------------------------------------------------------------------------ [SMPL_DELTA] typ=N dft=300 dsc="Time between two sample starts (in seconds)" err="The number of seconds must be an integer greater than zero" inp="Specify the time, in seconds, between two sample starts" lvl=1 ref=I]0,[ val=F [SMPL_MODULES] typ=T dft=S800NPRF,S898XSMP dsc="List of modules to collect" [SMPL_SLEEP] typ=N dft=60 dsc="Minimum sleep time between two samples (in seconds)" err="The number of seconds must be an integer greater than zero" inp="Specify the minimum sleep time, in seconds, between two samples" lvl=1 ref=I]0,[ val=F #------------------------------------------------------------------------------ # Archiving control #------------------------------------------------------------------------------ [SMPL_KEEP] typ=N dft=7 dsc="Number of sample archive files to keep" err="The number of files must be a positive integer" hlp="When this value is set to nonzero, SMPL_KEEP indicates the maximum \ number of sample archive files to keep. When this number is exceeded, \ RDA removes extra archives. When this value is set to zero, there is \ no constraint on the number of sample archives files that can be retained." inp="Specify the maximum number of sample archive files to keep" lvl=1 ref=I[0,[ val=F [SMPL_LAST] typ=N dft=0 dsc="Time of last archiving" [SMPL_RATE] typ=N dft=24 dsc="Archiving rate (in hours)" err="The number of hours must be a positive number" inp="Specify the archiving rate, in hours" lvl=1 ref=R[0,[ val=F [SMPL_SIZE] typ=N dft=0 dsc="Maximum total archive size (in MiB)" err="The number of MiB must be a positive number" hlp="When this value is set to nonzero, SMPL_SIZE specified the maximum \ amount of disk space the sample archive files may consume. When this \ value is set to zero, there is no space constraint." inp="Specify, in MiB, the maximum total archive size" lvl=1 ref=R[0,[ val=F