*.conf Files in /etc

     /etc/autofs_ldap_auth.conf File
/etc/conman.conf File
/etc/dhcp6c.conf File
/etc/dnsmasq.conf File
/etc/esd.conf File
/etc/gpm-root.conf File
/etc/grub.conf File
/etc/gssapi_mech.conf File
/etc/host.conf File
/etc/idmapd.conf File
/etc/initlog.conf File
/etc/jwhois.conf File
/etc/krb5.conf File
/etc/ld.so.conf File
/etc/ldap.conf File
     /etc/lftp.conf File
/etc/libaudit.conf File
/etc/libuser.conf File
/etc/logrotate.conf File
/etc/mcelog.conf File
/etc/mke2fs.conf File
/etc/modprobe.conf File
/etc/mtools.conf File
/etc/multipath.conf File
/etc/nscd.conf File
/etc/nsswitch.conf File
/etc/ntp.conf File
/etc/oddjobd.conf File
/etc/pam_smb.conf File
/etc/prelink.conf File
     /etc/reader.conf File
/etc/resolv.conf File
/etc/sensors.conf File
/etc/sestatus.conf File
/etc/smartd.conf File
/etc/smi.conf File
/etc/sysctl.conf File
/etc/syslog.conf File
/etc/updatedb.conf File
/etc/warnquota.conf File
/etc/yp.conf File
/etc/yum.conf File
/etc/security/limits.conf File
/etc/sysconfig/rawdevices File
/etc/sysconfig/selinux File

/etc/autofs_ldap_auth.conf File

 -rw------- 1 root root 3578  Feb 10 21:18 2011  Nov  2 02:30 2010  autofs_ldap_auth.conf

Back to top

/etc/conman.conf File

 -rw-r--r-- 1 root root 6308  Feb 10 21:11 2011  Jun 28 15:51 2007  conman.conf
##
# ConMan daemon configuration file
##
# $Id: conman.conf 500 2005-02-10 02:19:46Z dun $
##
# - Whitespace is ignored.
# - Comments are ignored (from the pound char to the newline).
# - Directives are terminated by a newline.
# - Directives may span multiple lines by escaping the newline
#     (ie, immediately preceding it with a backslash char).
# - Integers may begin with either a plus or minus, and contain only digits.
# - Strings may be single-quoted or double-quoted.
# - Strings cannot contain newlines.
# - Unquoted strings are sequences of letters, digits, and underscores;
#     they may not begin with a digit (just like a C identifier).
# - Tokens are unquoted case-insensitive strings.
##

##
# The daemon's KEEPALIVE keyword specifies whether the daemon will use
#   TCP keep-alives for detecting dead connections.  The default is ON.
##
# SERVER keepalive=(on|off)
##

##
# The daemon's LOGDIR keyword specifies a directory prefix for log files
#   that are not defined via an absolute pathname.
##
# SERVER logdir="<dir>"
##

##
# The daemon's LOGFILE keyword specifies the file to which log messages
#   are appended.  This string undergoes conversion specifier expansion.
#   If an absolute pathname is not specified, the file's location is relative
#   to LOGDIR (assuming it has been previously defined).  This file will be
#   created if it does not already exist.
# The filename may optionally be followed by a comma and a minimum priority
#   at which messages will be logged.  Refer to the syslog.conf(5) man page
#   for a list of priorities.  The default priority is 'info'.
# If this keyword is used in conjunction with the SYSLOG keyword,
#   messages will be sent to both locations.
##
# SERVER logfile="<file>[,<priority>]"
##

##
# The daemon's LOOPBACK keyword specifies whether the daemon will bind its
#   socket to the loopback address, thereby only accepting local client
#   connections directed to that address (127.0.0.1).  The default is OFF.
##
# SERVER loopback=(on|off)
##

##
# The daemon's PIDFILE keyword specifies the file to which the daemon's PID
#   is written.  The use of a pidfile is recommended if you want to use the
#   daemon's '-k' or '-r' options.
##
# SERVER pidfile="<file>"
##

##
# The daemon's PORT keyword specifies the port on which the daemon will
#   listen for client connections.
##
# SERVER port=<int>
##

##
# The daemon's RESETCMD keyword specifies a command string to be invoked by
#   a subshell upon receipt of the client's "reset" escape.  Multiple commands
#   within a string may be separated with semicolons.  This string undergoes
#   conversion specifier expansion and will be invoked multiple times if the
#   client is connected to multiple consoles.
##
# SERVER resetcmd="<str>"
##

##
# The daemon's SYSLOG keyword specifies that log messages are to be sent
#   to the system logger (syslogd) at the given facility.  Refer to the
#   syslog.conf(5) man page for a list of facilities.
# If this keyword is used in conjunction with the LOGFILE keyword,
#   messages will be sent to both locations.
##
# SERVER syslog="<facility>"
##

##
# The daemon's TCPWRAPPERS keyword specifies whether the daemon will
#   use Wietse Venema's TCP-Wrappers when accepting client connections.
#   Support for this feature must be enabled at compile-time
#   (via configure's "--with-tcp-wrappers" option).  Refer to the
#   hosts_access(5) and hosts_options(5) man pages for more details.
#   The default is OFF.
##
# SERVER tcpwrappers=(on|off)
##

##
# The daemon's TIMESTAMP keyword specifies the interval between timestamps
#   written to all console log files.  The interval is an integer that may
#   be followed by a single-char modifier; 'm' for minutes (the default),
#   'h' for hours, or 'd' for days.  The default is 0 (ie, no timestamps).
##
# SERVER timestamp=<int>(m|h|d)
##

##
# The global LOG keyword specifies the default log file to use for each
#   CONSOLE directive.  This string undergoes conversion specifier expansion
#   and must contain either '%N' or '%D'.  If an absolute pathname is not
#   given, the file's location is relative to LOGDIR (assuming it has been
#   previously defined).
##
# GLOBAL log="<file>"
##

##
#  The global LOGOPTS keyword specifies options for console log files.
#    These options can be overridden on an per-console basis by specifying
#    the CONSOLE LOGOPTS keyword.  Note that options affecting the output
#    of the console's logfile also affect the output of the console's
#    log-replay escape.
#  The valid logoptions include the following:
#    - "sanitize" or "nosanitize" - sanitized logs convert non-printable
#      characters into 7-bit printable characters.
#    - "timestamp" or "notimestamp" - timestamped logs prepend each line
#      of console output with a timestamp in "YYYY-MM-DD HH:MM:SS" format.
#      This timestamp is generated when the first character following the
#      line break is output.
#  The default is "nosanitize,notimestamp".
##
# GLOBAL logopts="nosanitize,notimestamp"
##

##
# The global SEROPTS keyword specifies options for local serial devices;
#    These options can be overridden on an per-console basis by specifying
#    the CONSOLE SEROPTS keyword.
# The default is "9600,8n1" for 9600 bps, 8 data bits, no parity, 1 stop bit.
##
# GLOBAL seropts="9600,8n1"
##

##
# The CONSOLE directive defines a console being managed by the daemon.
# The NAME keyword specifies the name used by clients to refer to the console.
# The DEV keyword specifies the location of the device.  A local serial-port
#   connection is specified with the pathname of the tty device.  A remote
#   terminal-server connection is specified with the "host:port" format
#   (where host is either a hostname or IP address).
# The optional LOG keyword specifies the file where console output is logged.
#   This string undergoes conversion specifier expansion.  If an absolute
#   pathname is not given, the file's location is relative to LOGDIR
#   (assuming it has been previously defined).  An empty log string
#   (ie, log="") disables logging, overriding the global log name.
# The optional LOGOPTS and SEROPTS keywords override the global settings.
##
# CONSOLE name="<str>" dev="<str>" \
#   [log="<file>"] [logopts="<str>"] [seropts="<str>"]
##

Back to top

/etc/dhcp6c.conf File

 -rw-r--r-- 1 root root 178  Feb 10 21:18 2011  Oct 25 10:58 2010  dhcp6c.conf
#
# See dhcp6c.conf(5) man page for details.
#

#interface eth0 {
#    #information-only;
#    send rapid-commit;
#    request prefix-delegation;
#    #request temp-address;
#};

Back to top

/etc/dnsmasq.conf File

 -rw-r--r-- 1 root root 18484  Feb 10 21:11 2011  Aug 25 13:49 2009  dnsmasq.conf
# Configuration file for dnsmasq.
#
# Format is one option per line, legal options are the same
# as the long options legal on the command line. See
# "/usr/sbin/dnsmasq --help" or "man 8 dnsmasq" for details.

# The following two options make you a better netizen, since they
# tell dnsmasq to filter out queries which the public DNS cannot
# answer, and which load the servers (especially the root servers)
# uneccessarily. If you have a dial-on-demand link they also stop
# these requests from bringing up the link uneccessarily.

# Never forward plain names (without a dot or domain part)
#domain-needed
# Never forward addresses in the non-routed address spaces.
#bogus-priv


# Uncomment this to filter useless windows-originated DNS requests
# which can trigger dial-on-demand links needlessly.
# Note that (amongst other things) this blocks all SRV requests,
# so don't use it if you use eg Kerberos, SIP, XMMP or Google-talk.
# This option only affects forwarding, SRV records originating for
# dnsmasq (via srv-host= lines) are not suppressed by it.
#filterwin2k

# Change this line if you want dns to get its upstream servers from
# somewhere other that /etc/resolv.conf
#resolv-file=

# By  default,  dnsmasq  will  send queries to any of the upstream
# servers it knows about and tries to favour servers to are  known
# to  be  up.  Uncommenting this forces dnsmasq to try each query
# with  each  server  strictly  in  the  order  they   appear   in
# /etc/resolv.conf
#strict-order

# If you don't want dnsmasq to read /etc/resolv.conf or any other
# file, getting its servers from this file instead (see below), then
# uncomment this.
#no-resolv

# If you don't want dnsmasq to poll /etc/resolv.conf or other resolv
# files for changes and re-read them then uncomment this.
#no-poll

# Add other name servers here, with domain specs if they are for
# non-public domains.
#server=/localnet/192.168.0.1

# Example of routing PTR queries to nameservers: this will send all
# address->name queries for 192.168.3/24 to nameserver 10.1.2.3
#server=/3.168.192.in-addr.arpa/10.1.2.3

# Add local-only domains here, queries in these domains are answered
# from /etc/hosts or DHCP only.
#local=/localnet/

# Add domains which you want to force to an IP address here.
# The example below send any host in doubleclick.net to a local
# webserver.
#address=/doubleclick.net/127.0.0.1

# --address (and --server) work with IPv6 addresses too.
#address=/www.thekelleys.org.uk/fe80::20d:60ff:fe36:f83

# You can control how dnsmasq talks to a server: this forces
# queries to 10.1.2.3 to be routed via eth1
# --server=10.1.2.3@eth1

# and this sets the source (ie local) address used to talk to
# 10.1.2.3 to 192.168.1.1 port 55 (there must be a interface with that
# IP on the machine, obviously).
# --server=10.1.2.3@192.168.1.1#55

# If you want dnsmasq to change uid and gid to something other
# than the default, edit the following lines.
#user=
#group=

# If you want dnsmasq to listen for DHCP and DNS requests only on
# specified interfaces (and the loopback) give the name of the
# interface (eg eth0) here.
# Repeat the line for more than one interface.
#interface=
# Or you can specify which interface _not_ to listen on
#except-interface=
# Or which to listen on by address (remember to include 127.0.0.1 if
# you use this.)
#listen-address=
# If you want dnsmasq to provide only DNS service on an interface,
# configure it as shown above, and then use the following line to
# disable DHCP on it.
#no-dhcp-interface=

# On systems which support it, dnsmasq binds the wildcard address,
# even when it is listening on only some interfaces. It then discards
# requests that it shouldn't reply to. This has the advantage of
# working even when interfaces come and go and change address. If you
# want dnsmasq to really bind only the interfaces it is listening on,
# uncomment this option. About the only time you may need this is when
# running another nameserver on the same machine.
#bind-interfaces

# If you don't want dnsmasq to read /etc/hosts, uncomment the
# following line.
#no-hosts
# or if you want it to read another file, as well as /etc/hosts, use
# this.
#addn-hosts=/etc/banner_add_hosts

# Set this (and domain: see below) if you want to have a domain
# automatically added to simple names in a hosts-file.
#expand-hosts

# Set the domain for dnsmasq. this is optional, but if it is set, it
# does the following things.
# 1) Allows DHCP hosts to have fully qualified domain names, as long
#     as the domain part matches this setting.
# 2) Sets the "domain" DHCP option thereby potentially setting the
#    domain of all systems configured by DHCP
# 3) Provides the domain part for "expand-hosts"
#domain=thekelleys.org.uk

# Uncomment this to enable the integrated DHCP server, you need
# to supply the range of addresses available for lease and optionally
# a lease time. If you have more than one network, you will need to
# repeat this for each network on which you want to supply DHCP
# service.
#dhcp-range=192.168.0.50,192.168.0.150,12h

# This is an example of a DHCP range where the netmask is given. This
# is needed for networks we reach the dnsmasq DHCP server via a relay
# agent. If you don't know what a DHCP relay agent is, you probably
# don't need to worry about this.
#dhcp-range=192.168.0.50,192.168.0.150,255.255.255.0,12h

# This is an example of a DHCP range with a network-id, so that
# some DHCP options may be set only for this network.
#dhcp-range=red,192.168.0.50,192.168.0.150

# Supply parameters for specified hosts using DHCP. There are lots
# of valid alternatives, so we will give examples of each. Note that
# IP addresses DO NOT have to be in the range given above, they just
# need to be on the same network. The order of the parameters in these
# do not matter, it's permissble to give name,adddress and MAC in any order

# Always allocate the host with ethernet address 11:22:33:44:55:66
# The IP address 192.168.0.60
#dhcp-host=11:22:33:44:55:66,192.168.0.60

# Always set the name of the host with hardware address
# 11:22:33:44:55:66 to be "fred"
#dhcp-host=11:22:33:44:55:66,fred

# Always give the host with ethernet address 11:22:33:44:55:66
# the name fred and IP address 192.168.0.60 and lease time 45 minutes
#dhcp-host=11:22:33:44:55:66,fred,192.168.0.60,45m

# Give the machine which says its name is "bert" IP address
# 192.168.0.70 and an infinite lease
#dhcp-host=bert,192.168.0.70,infinite

# Always give the host with client identifier 01:02:02:04
# the IP address 192.168.0.60
#dhcp-host=id:01:02:02:04,192.168.0.60

# Always give the host with client identifier "marjorie"
# the IP address 192.168.0.60
#dhcp-host=id:marjorie,192.168.0.60

# Enable the address given for "judge" in /etc/hosts
# to be given to a machine presenting the name "judge" when
# it asks for a DHCP lease.
#dhcp-host=judge

# Never offer DHCP service to a machine whose ethernet
# address is 11:22:33:44:55:66
#dhcp-host=11:22:33:44:55:66,ignore

# Ignore any client-id presented by the machine with ethernet
# address 11:22:33:44:55:66. This is useful to prevent a machine
# being treated differently when running under different OS's or
# between PXE boot and OS boot.
#dhcp-host=11:22:33:44:55:66,id:*

# Send extra options which are tagged as "red" to
# the machine with ethernet address 11:22:33:44:55:66
#dhcp-host=11:22:33:44:55:66,net:red

# Send extra options which are tagged as "red" to
# any machine with ethernet address starting 11:22:33:
#dhcp-host=11:22:33:*:*:*,net:red

# Ignore any clients which are specified in dhcp-host lines
# or /etc/ethers. Equivalent to ISC "deny unkown-clients".
# This relies on the special "known" tag which is set when
# a host is matched.
#dhcp-ignore=#known

# Send extra options which are tagged as "red" to any machine whose
# DHCP vendorclass string includes the substring "Linux"
#dhcp-vendorclass=red,Linux

# Send extra options which are tagged as "red" to any machine one
# of whose DHCP userclass strings includes the substring "accounts"
#dhcp-userclass=red,accounts

# Send extra options which are tagged as "red" to any machine whose
# MAC address matches the pattern.
#dhcp-mac=red,00:60:8C:*:*:*

# If this line is uncommented, dnsmasq will read /etc/ethers and act
# on the ethernet-address/IP pairs found there just as if they had
# been given as --dhcp-host options. Useful if you keep
# MAC-address/host mappings there for other purposes.
#read-ethers

# Send options to hosts which ask for a DHCP lease.
# See RFC 2132 for details of available options.
# Common options can be given to dnsmasq by name:
# run "dnsmasq --help dhcp" to get a list.
# Note that all the common settings, such as netmask and
# broadcast address, DNS server and default route, are given
# sane defaults by dnsmasq. You very likely will not need
# any dhcp-options. If you use Windows clients and Samba, there
# are some options which are recommended, they are detailed at the
# end of this section.

# Override the default route supplied by dnsmasq, which assumes the
# router is the same machine as the one running dnsmasq.
#dhcp-option=3,1.2.3.4

# Do the same thing, but using the option name
#dhcp-option=option:router,1.2.3.4

# Override the default route supplied by dnsmasq and send no default
# route at all. Note that this only works for the options sent by
# default (1, 3, 6, 12, 28) the same line will send a zero-length option
# for all other option numbers.
#dhcp-option=3

# Set the NTP time server addresses to 192.168.0.4 and 10.10.0.5
#dhcp-option=option:ntp-server,192.168.0.4,10.10.0.5

# Set the NTP time server address to be the same machine as
# is running dnsmasq
#dhcp-option=42,0.0.0.0

# Set the NIS domain name to "welly"
#dhcp-option=40,welly

# Set the default time-to-live to 50
#dhcp-option=23,50

# Set the "all subnets are local" flag
#dhcp-option=27,1

# Send the etherboot magic flag and then etherboot options (a string).
#dhcp-option=128,e4:45:74:68:00:00
#dhcp-option=129,NIC=eepro100

# Specify an option which will only be sent to the "red" network
# (see dhcp-range for the declaration of the "red" network)
# Note that the net: part must precede the option: part.
#dhcp-option = net:red, option:ntp-server, 192.168.1.1

# The following DHCP options set up dnsmasq in the same way as is specified
# for the ISC dhcpcd in
# http://www.samba.org/samba/ftp/docs/textdocs/DHCP-Server-Configuration.txt
# adapted for a typical dnsmasq installation where the host running
# dnsmasq is also the host running samba.
# you may want to uncomment them if you use Windows clients and Samba.
#dhcp-option=19,0           # option ip-forwarding off
#dhcp-option=44,0.0.0.0     # set netbios-over-TCP/IP nameserver(s) aka WINS server(s)
#dhcp-option=45,0.0.0.0     # netbios datagram distribution server
#dhcp-option=46,8           # netbios node type
#dhcp-option=47             # empty netbios scope.

# Send RFC-3397 DNS domain search DHCP option. WARNING: Your DHCP client
# probably doesn't support this......
#dhcp-option=option:domain-search,eng.apple.com,marketing.apple.com

# Send RFC-3442 classless static routes (note the netmask encoding)
#dhcp-option=121,192.168.1.0/24,1.2.3.4,10.0.0.0/8,5.6.7.8

# Send vendor-class specific options encapsulated in DHCP option 43.
# The meaning of the options is defined by the vendor-class so
# options are sent only when the client supplied vendor class
# matches the class given here. (A substring match is OK, so "MSFT"
# matches "MSFT" and "MSFT 5.0"). This example sets the
# mtftp address to 0.0.0.0 for PXEClients.
#dhcp-option=vendor:PXEClient,1,0.0.0.0

# Send microsoft-specific option to tell windows to release the DHCP lease
# when it shuts down. Note the "i" flag, to tell dnsmasq to send the
# value as a four-byte integer - that's what microsoft wants. See
# http://technet2.microsoft.com/WindowsServer/en/library/a70f1bb7-d2d4-49f0-96d6-4b7414ecfaae1033.mspx?mfr=true
#dhcp-option=vendor:MSFT,2,1i

# Send the Encapsulated-vendor-class ID needed by some configurations of
# Etherboot to allow is to recognise the DHCP server.
#dhcp-option=vendor:Etherboot,60,"Etherboot"

# Send options to PXELinux. Note that we need to send the options even
# though they don't appear in the parameter request list, so we need
# to use dhcp-option-force here.
# See http://syslinux.zytor.com/pxe.php#special for details.
# Magic number - needed before anything else is recognised
#dhcp-option-force=208,f1:00:74:7e
# Configuration file name
#dhcp-option-force=209,configs/common
# Path prefix
#dhcp-option-force=210,/tftpboot/pxelinux/files/
# Reboot time. (Note 'i' to send 32-bit value)
#dhcp-option-force=211,30i

# Set the boot filename for BOOTP. You will only need
# this is you want to boot machines over the network and you will need
# a TFTP server; either dnsmasq's built in TFTP server or an
# external one. (See below for how to enable the TFTP server.)
#dhcp-boot=pxelinux.0

# Boot for Etherboot gPXE. The idea is to send two different
# filenames, the first loads gPXE, and the second tells gPXE what to
# load. The dhcp-match sets the gpxe tag for requests from gPXE.
#dhcp-match=gpxe,175 # gPXE sends a 175 option.
#dhcp-boot=net:#gpxe,undionly.kpxe
#dhcp-boot=mybootimage

# Enable dnsmasq's built-in TFTP server
#enable-tftp

# Set the root directory for files availble via FTP.
#tftp-root=/var/ftpd

# Make the TFTP server more secure: with this set, only files owned by
# the user dnsmasq is running as will be send over the net.
#tftp-secure

# Set the boot file name only when the "red" tag is set.
#dhcp-boot=net:red,pxelinux.red-net

# An example of dhcp-boot with an external server: the name and IP
# address of the server are given after the filename.
#dhcp-boot=/var/ftpd/pxelinux.0,boothost,192.168.0.3

# Set the limit on DHCP leases, the default is 150
#dhcp-lease-max=150

# The DHCP server needs somewhere on disk to keep its lease database.
# This defaults to a sane location, but if you want to change it, use
# the line below.
#dhcp-leasefile=/var/lib/misc/dnsmasq.leases

# Set the DHCP server to authoritative mode. In this mode it will barge in
# and take over the lease for any client which broadcasts on the network,
# whether it has a record of the lease or not. This avoids long timeouts
# when a machine wakes up on a new network. DO NOT enable this if there's
# the slighest chance that you might end up accidentally configuring a DHCP
# server for your campus/company accidentally. The ISC server uses
# the same option, and this URL provides more information:
# http://www.isc.org/index.pl?/sw/dhcp/authoritative.php
#dhcp-authoritative

# Run an executable when a DHCP lease is created or destroyed.
# The arguments sent to the script are "add" or "del",
# then the MAC address, the IP address and finally the hostname
# if there is one.
#dhcp-script=/bin/echo

# Set the cachesize here.
#cache-size=150

# If you want to disable negative caching, uncomment this.
#no-negcache

# Normally responses which come form /etc/hosts and the DHCP lease
# file have Time-To-Live set as zero, which conventionally means
# do not cache further. If you are happy to trade lower load on the
# server for potentially stale date, you can set a time-to-live (in
# seconds) here.
#local-ttl=

# If you want dnsmasq to detect attempts by Verisign to send queries
# to unregistered .com and .net hosts to its sitefinder service and
# have dnsmasq instead return the correct NXDOMAIN response, uncomment
# this line. You can add similar lines to do the same for other
# registries which have implemented wildcard A records.
#bogus-nxdomain=64.94.110.11

# If you want to fix up DNS results from upstream servers, use the
# alias option. This only works for IPv4.
# This alias makes a result of 1.2.3.4 appear as 5.6.7.8
#alias=1.2.3.4,5.6.7.8
# and this maps 1.2.3.x to 5.6.7.x
#alias=1.2.3.0,5.6.7.0,255.255.255.0


# Change these lines if you want dnsmasq to serve MX records.

# Return an MX record named "maildomain.com" with target
# servermachine.com and preference 50
#mx-host=maildomain.com,servermachine.com,50

# Set the default target for MX records created using the localmx option.
#mx-target=servermachine.com

# Return an MX record pointing to the mx-target for all local
# machines.
#localmx

# Return an MX record pointing to itself for all local machines.
#selfmx

# Change the following lines if you want dnsmasq to serve SRV
# records.  These are useful if you want to serve ldap requests for
# Active Directory and other windows-originated DNS requests.
# See RFC 2782.
# You may add multiple srv-host lines.
# The fields are <name>,<target>,<port>,<priority>,<weight>
# If the domain part if missing from the name (so that is just has the
# service and protocol sections) then the domain given by the domain=
# config option is used. (Note that expand-hosts does not need to be
# set for this to work.)

# A SRV record sending LDAP for the example.com domain to
# ldapserver.example.com port 289
#srv-host=_ldap._tcp.example.com,ldapserver.example.com,389

# A SRV record sending LDAP for the example.com domain to
# ldapserver.example.com port 289 (using domain=)
#domain=example.com
#srv-host=_ldap._tcp,ldapserver.example.com,389

# Two SRV records for LDAP, each with different priorities
#srv-host=_ldap._tcp.example.com,ldapserver.example.com,389,1
#srv-host=_ldap._tcp.example.com,ldapserver.example.com,389,2

# A SRV record indicating that there is no LDAP server for the domain
# example.com
#srv-host=_ldap._tcp.example.com

# The following line shows how to make dnsmasq serve an arbitrary PTR
# record. This is useful for DNS-SD. (Note that the
# domain-name expansion done for SRV records _does_not
# occur for PTR records.)
#ptr-record=_http._tcp.dns-sd-services,"New Employee Page._http._tcp.dns-sd-services"

# Change the following lines to enable dnsmasq to serve TXT records.
# These are used for things like SPF and zeroconf. (Note that the
# domain-name expansion done for SRV records _does_not
# occur for TXT records.)

#Example SPF.
#txt-record=example.com,"v=spf1 a -all"

#Example zeroconf
#txt-record=_http._tcp.example.com,name=value,paper=A4


# For debugging purposes, log each DNS query as it passes through
# dnsmasq.
#log-queries

# Log lots of extra information about DHCP transactions.
#log-dhcp

# Include a another lot of configuration options.
#conf-file=/etc/dnsmasq.more.conf
conf-dir=/etc/dnsmasq.d

Back to top

/etc/esd.conf File

 -rw-r--r-- 1 root root 153  Feb 17 21:03 2011  Jul 27 22:35 2006  esd.conf
[esd]
auto_spawn=1
spawn_options=-terminate -nobeeps -as 2
spawn_wait_ms=100
# default options are used in spawned and non-spawned mode
default_options=

Back to top

/etc/gpm-root.conf File

 -rw-r--r-- 1 root root 1756  Feb 10 21:11 2011  Jul 12 13:33 2006  gpm-root.conf
# sample configuration file for gpm-root
# edit it to please your taste....

button 1 {
  name "ttys"

  ""        f.nop
  "login on a new tty" f.mktty
  ""        f.nop
  "tty  1"  f.jptty  "1"
  "tty  2"  f.jptty  "2"
  "tty  3"  f.jptty  "3"
  "tty  4"  f.jptty  "4"
  ""         f.nop
  "tty  5"  f.jptty   "5"
  "tty  6"  f.jptty   "6"
  "tty  7"  f.jptty   "7"
  "tty  8"  f.jptty   "8"
  ""        f.nop
  "more of them..." {

    "tty  9"  f.jptty  "9"
    "tty 10"  f.jptty  "10"
    "tty 11"  f.jptty  "11"
    "tty 12"  f.jptty  "12"
    ""         f.nop
    "tty 13"  f.jptty   "13"
    "tty 14"  f.jptty   "14"
    "tty 15"  f.jptty   "15"
    "tty 16"  f.jptty   "16"
    ""        f.nop
    "more of them..." {
	  "tty 17" f.jptty  "17"
      }
  }

}

button 2 {
  name "system status"
  foreground red
  background black
  border yellow
  head bright yellow

  ""          f.nop
  "%b %d %Y"  f.time
  "%H:%M"     f.time
  ""          f.nop
  "load: "    f.load
  "free:"     f.free
  "" f.nop
  "report disk usage to ~/du" f.bgcmd  "du ~ | sort -rn > ~/du"
  "print mail headers to tty" f.bgcmd
	 "grep '^From ' /var/spool/mail/$USER | tail"
}

button 3 {
  name "far ttys"

  foreground black
  background red
  border bright yellow
  head bright yellow

  "tty  9"  f.jptty   "9"
  "tty 10"  f.jptty  "10"
  "tty 11"  f.jptty  "11"
  "tty 12"  f.jptty "12"
  ""         f.nop

  "tty 13" f.jptty "13"
  "tty 14" f.jptty "14"
  "tty 15" f.jptty "15"
  "tty 16" f.jptty "16"
  ""         f.nop

# I use this to halt and reboot the system, but it isn't wise to put it
# in widely accessible boxes.
#
#  "----"     f.nop
#  ""         f.nop
#  "halt"   f.bgcmd "/sbin/shutdown -h now"
#  "reboot" f.bgcmd "/sbin/shutdown -r now"
}

Back to top

/etc/grub.conf File

 lrwxrwxrwx 1 root root 22  Feb 10 21:12 2011  Feb 10 21:12 2011  grub.conf -> ../boot/grub/grub.conf

Back to top

/etc/gssapi_mech.conf File

 -rw-r--r-- 1 root root 833  Feb 10 21:11 2011  Jan 17 01:20 2007  gssapi_mech.conf
# Example /etc/gssapi_mech.conf file
#
# GSSAPI Mechanism Definitions
#
# This configuration file determines which GSS-API mechanisms
# the gssd code should use
#
# NOTE:
# The initiaiization function "mechglue_internal_krb5_init"
# is used for the MIT krb5 gssapi mechanism.  This special
# function name indicates that an internal function should
# be used to determine the entry points for the MIT gssapi
# mechanism funtions.
#
# library                               initialization function
# ================================	==========================
# The MIT K5 gssapi library, use special function for initialization.
libgssapi_krb5.so.2		mechglue_internal_krb5_init
#
# The SPKM3 gssapi library function.  Use the function spkm3_gss_initialize.
# /usr/local/gss_mechs/spkm/spkm3/libgssapi_spkm3.so    spkm3_gss_initialize

Back to top

/etc/host.conf File

 -rw-r--r-- 1 root root 17  Feb 10 21:10 2011  Jul 23 15:06 2000  host.conf
order hosts,bind

Back to top

/etc/idmapd.conf File

 -rw-r--r-- 1 root root 177  Feb 10 21:18 2011  Nov 18 19:01 2010  idmapd.conf
[General]

Verbosity = 0
Pipefs-Directory = /var/lib/nfs/rpc_pipefs
Domain = localdomain

[Mapping]

Nobody-User = nobody
Nobody-Group = nobody

[Translation]
Method = nsswitch

Back to top

/etc/initlog.conf File

 -rw-r--r-- 1 root root 658  Feb 10 21:18 2011  Oct 13 13:42 2010  initlog.conf
# /etc/initlog.conf
#
# initlog configuration file
#
# lines preceded by a '#' are comments
#
# anything not recognized is ignored. :)

# This sets the default logging facility. (can override with command line arguments)
facility local7

# This sets the default logging priority. (can override with command line arguments)
priority notice

# ignore foo
# means to discard any output lines that match the regular expression foo

# This regexp is useful if you use fsck's -C option.
ignore [^:]+: \|[=]+
# This regexp is useful for fsck's feature of setting file types
ignore [^:]+: Setting filetype
# This regexp is useful for quotacheck
ignore ^[-\\\|\/]$

Back to top

/etc/jwhois.conf File

 -rw-r--r-- 1 root root 31971  Feb 10 21:17 2011  Oct  4 11:21 2010  jwhois.conf
# This is jwhois.conf - an example configuration file for jwhois
#
# Due to the ever-changing nature of the Internet, the configuration file
# released with Jwhois quickly gets outdated. You can find the latest version
# in the Jwhois CVS repository, which is accessible via the web from
# http://savannah.gnu.org/cgi-bin/viewcvs/jwhois/jwhois/example/jwhois.conf

#
# Local domain registries and pointers to cidr-blocks and handles.
# This is where jwhois begins the search for a Whois server to query
#
whois-servers {
	#
	# The type can be either cidr or regex, the former matches using CIDR
	# blocks and the later using regular expressions.
	#
	type = regex;

	#
	# You can use the special value `struct' to redirect the query
	# to another block which optionally can use another type of matching.
	# Here we use it to have IPv4 numbers matched using CIDR blocks instead
	# of regular expressions.  See below for the definition of cidr-blocks.
	#
	"\\([0-9]+\\.\\)+[0-9]+" = "struct cidr-blocks";
	"^CORE-[0-9]+$" = "struct handles";
	"^CO[CH]O-[0-9]+$" = "struct handles";
	".*-[A-Z]+$" = "struct handles";

	#
	# Catch AS numbers
	#
	"^[0-9]+$" = "whois.arin.net";
	"^ASN-.+" = "whois.arin.net";
	"^AS[0-9]+$" = "whois.radb.net";

	#
	# Catch ARIN nameserver records
	#
	"^NS[0-9]+-HST$" = "whois.arin.net";

	#
	# Catch ARIN netblock records
	#
	"^!?NET\\(BLK\\)?\\(-[A-Z0-9]+\\)+$" = "whois.arin.net";

	#
	# Catch Verio netblock records
	#
	"^!?NET\\(BLK\\)?-VRIO\\(-[A-Z0-9]+\\)+$" = "rwhois.verio.net";

	#
	# Catch Registro .BR ownerid records
	#
	"^[0-9]+\\.[0-9]+\\.[0-9]+/[0-9]+-[0-9]+$" = "whois.nic.br";

	#
	# Japanese NIC handles
	#
	"^[A-Z]+[0-9]+JP$" = "whois.nic.ad.jp";

	#
	# Sub-TLA Assignments
	# see http://www.iana.org/assignments/ipv6-tla-assignments
	#
	"^2001:0?[01][A-F0-9][A-F0-9]:.+" = "whois.iana.org";
	"^2001:0?[23][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	"^2001:0?[45][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	"^2001:0?[67][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:0?[89][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:0?[AB][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:0?[CD][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	"^2001:0?[EF][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	"^2001:1[23][A-F0-9][A-F0-9]:.+" = "whois.lacnic.net";
	"^2001:1[45][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:1[67][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:1[89][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	"^2001:1[AB][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:1[CD][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:1[EF][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:2[A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:3[A-B0-9][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:4[01][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:4[23][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	"^2001:4[45][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	"^2001:4[67][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:4[89][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	"^2001:4[AB][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	"^2001:4[CD][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	# ...
	"^2001:5[A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	# ...
	"^2001:[89AB][A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	# 2003:0000::/18
	"^2003:[0123][A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	# 2400:0000::/19
	"^2400:[01][A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	# 2400:2000::/19
	"^2400:[23][A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	# 2400:4000::/21
	"^2400:4[0-7][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	# 2404:0000::/23
	"^2404:0?[01][A-F0-9][A-F0-9]:.+" = "whois.apnic.net";
	# 2600:0000::/22
	"^2600:0?[0-3][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	# 2604:0000::/22
	"^2604:0?[0-3][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	# 2608:0000::/22
	"^2608:0?[0-3][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	# 260C:0000::/22
	"^260C:0?[0-3][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	# 2610:0000::/23
	"^2610:0?[0-1][A-F0-9][A-F0-9]:.+" = "whois.arin.net";
	# 2800:0000::/23
	"^2800:0?[0-1][A-F0-9][A-F0-9]:.+" = "whois.lacnic.net";
	# 2A00:0000::/21
	"^2A00:0?[0-7][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";
	# 2A01:0000::/16
	"^2A01:[A-F0-9][A-F0-9][A-F0-9][A-F0-9]:.+" = "whois.ripe.net";

	#
	# Experimental IPv6 network 6bone (RFC2471)
	# Phaseout at Jun, 6 2006 (RFC3701)
	#
	"^3FFE:.+" = "whois.6bone.net";

	#
	# If your host and network supports it, you can also specify IPv6
	# addresses in the server field.
	#
	# ".*:.*" = "::1"
	#

	#
	# This is a special construct designed with the whois-servers.net
	# service in mind. If you use this, jwhois will query whois-servers.net
	# for which whois server to use for each domain query.
	#
	# default = "whois-servers";

	#
	# Pseudo-ccTLDs must be listed above gTLDs
	#
 	"\\.ae\\.org$" = "whois.centralnic.net";
	"\\.br\\.com$" = "whois.centralnic.net";
	"\\.cn\\.com$" = "whois.centralnic.net";
	"\\.de\\.com$" = "whois.centralnic.net";
	"\\.eu\\.com$" = "whois.centralnic.net";
	"\\.eu\\.org$" = "whois.eu.org";
	"\\.gb\\.com$" = "whois.centralnic.net";
	"\\.gb\\.net$" = "whois.centralnic.net";
	"\\.hu\\.com$" = "whois.centralnic.net";
	"\\.jpn\\.com$" = "whois.centralnic.net";
	"\\.kr\\.com$" = "whois.centralnic.net";
	"\\.no\\.com$" = "whois.centralnic.net";
	"\\.qc\\.com$" = "whois.centralnic.net";
	"\\.ru\\.com$" = "whois.centralnic.net";
	"\\.sa\\.com$" = "whois.centralnic.net";
	"\\.se\\.com$" = "whois.centralnic.net";
	"\\.se\\.net$" = "whois.centralnic.net";
	"\\.uk\\.com$" = "whois.centralnic.net";
	"\\.uk\\.net$" = "whois.centralnic.net";
	"\\.us\\.com$" = "whois.centralnic.net";
	"\\.uy\\.com$" = "whois.centralnic.net";
	"\\.web\\.com$" = "whois.centralnic.net";
	"\\.za\\.com$" = "whois.centralnic.net";

	"\\.ac$" = "whois.nic.ac";
	"\\.ae$" = "whois.aeda.net.ae";
	"\\.co\\.ae$" = "whois.aeda.net.ae";
	"\\.net\\.ae$" = "whois.aeda.net.ae";
	"\\.org\\.ae$" = "whois.aeda.net.ae";
	"\\.sch\\.ae$" = "whois.aeda.net.ae";
	"\\.ac\\.ae$" = "whois.aeda.net.ae";
	"\\.mil\\.ae$" = "whois.aeda.net.ae";
	"\\.gov\\.ae$" = "whois.aeda.net.ae";
	"\\.1\\.7\\.9\\.e164\\.arpa$" = "whois.aeda.net.ae";
	"\\.aero$" = "whois.aero";
	"\\.af$" = "whois.nic.af";
	"\\.ag$" = "whois.nic.ag";
	"\\.ai$" = "whois.offshore.ai";
	"\\.al$" = "whois.ripe.net";
	"\\.am$" = "whois.amnic.net";
	"\\.ar$" = "www.nic.ar";
	"\\.as$" = "whois.nic.as";
	"\\.at$" = "whois.nic.at";
	"\\.asn\\.au$" = "whois.ausregistry.net.au";
	"\\.com\\.au$" = "whois.ausregistry.net.au";
	"\\.id\\.au$" = "whois.ausregistry.net.au";
	"\\.net\\.au$" = "whois.ausregistry.net.au";
	"\\.org\\.au$" = "whois.ausregistry.net.au";
	"\\.au$" = "whois.aunic.net";
	"\\.az$" = "whois.ripe.net";
	"\\.ba$" = "whois.ripe.net";
	"\\.be$" = "whois.dns.be";
	"\\.bg$" = "whois.register.bg";
	"\\.bi$" = "www.nic.bi";
	"\\.biz$" = "whois.neulevel.biz";
	"\\.bj$" = "whois.nic.bj";
	"\\.bm$" = "rwhois.ibl.bm 4321";
	"\\.br$" = "whois.nic.br";
	"\\.bv$" = "whois.ripe.net";
	"\\.by$" = "whois.ripe.net";
	"\\.bz$" = "whois.belizenic.bz";
	"\\.ca$" = "whois.cira.ca";
	"\\.cat$" = "whois.cat";
	"\\.cc$" = "whois.nic.cc";
	"\\.cd$" = "whois.nic.cd";
	"\\.cg$" = "www.nic.cg";
	"\\.ch$" = "whois.nic.ch";
	"\\.ci$" = "whois.nic.ci";
	"\\.ck$" = "whois.nic.ck";
	"\\.cl$" = "whois.nic.cl";
	"\\.edu\\.cn$" = "whois.edu.cn";
	"\\.cn$" = "whois.cnnic.net.cn";
	"\\.com$" {
		whois-server = "whois.verisign-grs.com";
		query-format = "domain $*";
	}
	"\\.coop$" = "whois.nic.coop";
	"\\.cx$" = "whois.nic.cx";
	"\\.cy$" = "whois.ripe.net";
	"\\.cz$" = "whois.nic.cz";
	"\\.de$" {
		whois-server = "whois.denic.de";
		query-format = "-C UTF-8 -T dn,ace $*";
	}
	"\\.dk$" = "whois.dk-hostmaster.dk";
	"\\.dm$" = "whois.nic.dm";
	"\\.do$" = "whois.nic.do";
	"\\.dz$" = "whois.ripe.net";
	"\\.ec$" = "www.nic.ec";
	"\\.edu$" = "whois.educause.net";
	"\\.ee$" = "whois.eenet.ee";
	"\\.eg$" = "whois.ripe.net";
	"\\.es$" = "www.nic.es";
	"\\.eu$" = "whois.eu";
	"\\.fi$" = "whois.ficora.fi";
	"\\.fj$" = "whois.usp.ac.fj";
	"\\.fm$" = "www.dot.fm";
	"\\.fo$" = "whois.ripe.net";
	"\\.fr$" = "whois.nic.fr";
	"\\.gi$" = "whois2.afilias-grs.net";
	"\\.gov$" = "whois.nic.gov";
	"\\.gg$" = "whois.isles.net";
	"\\.gm$" = "whois.ripe.net";
	"\\.gp$" = "whois.nic.gp";
	"\\.gr$" = "whois.ripe.net";
	"\\.gs$" = "whois.nic.gs";
	"\\.gt$" = "www.gt";
	"\\.hk$" = "whois.hkdnr.net.hk";
	"\\.hm$" = "whois.registry.hm";
	"\\.hr$" = "www.dns.hr";
	"\\.hu$" = "whois.nic.hu";
	"\\.id$" = "whois.idnic.net.id";
	"\\.ie$" = "whois.domainregistry.ie";
	"\\.il$" = "whois.isoc.org.il";
	"\\.in$" = "whois.inregistry.in";
	"\\.info$" = "whois.afilias.info";
	"\\.int$" = "whois.iana.org";
	"\\.io$" = "www.io.io";
	"\\.ir$" = "whois.nic.ir";
	"\\.im$" = "whois.nic.im";
	"\\.is$" = "whois.isnic.is";
	"\\.it$" = "whois.nic.it";
	"\\.je$" = "whois.isles.net";
	"\\.jp$" {
		whois-server = "whois.jprs.jp";
		query-format = "$* /e";
	}
	"\\.kg$" = "whois.domain.kg";
	"\\.ki$" = "whois.nic.ki";
	"\\.kr$" = "whois.krnic.net";
	"\\.kz$" = "whois.nic.kz";
	"\\.la$" = "whois.nic.la";
	"\\.lb$" = "cgi.aub.edu.lb";
	"\\.li$" = "whois.nic.li";
	"\\.lk$" = "whois.nic.lk";
	"\\.lt$" = "whois.domreg.lt";
	"\\.lu$" = "whois.dns.lu";
	"\\.lv$" = "whois.nic.lv";
	"\\.ly$" = "whois.nic.ly";
	"\\.ma$" = "whois.ripe.net";
	"\\.mil$" = "whois.nic.mil";
	"\\.mk$" = "whois.ripe.net";
	"\\.mm$" = "whois.nic.mm";
	"\\.mobi$" = "whois.dotmobiregistry.net";
	"\\.ms$" = "whois.adamsnames.tc";
	"\\.mt$" = "www.um.edu.mt";
	"\\.mu$" = "whois.nic.mu";
	"\\.museum$" = "whois.museum";
	"\\.mw$" = "www.tarsus.net";
	"\\.mx$" = "whois.nic.mx";
	"\\.my$" = "whois.mynic.net.my";
	"\\.na$" = "whois.na-nic.com.na";
	"\\.name$" = "whois.nic.name";
	"\\.net$" {
		whois-server = "whois.verisign-grs.com";
		query-format = "domain $*";
	}
	"\\.ng$" = "whois.rg.net";
	"\\.nl$" = "whois.domain-registry.nl";
	"\\.no$" = "whois.norid.no";
	"\\.nu$" = "whois.nic.nu";
	"\\.nz$" = "whois.srs.net.nz";
	"\\.org$" = "whois.publicinterestregistry.net";
	"\\.pe$" = "whois.nic.pe";
	"\\.pk$" = "pknic.net.pk";
	"\\.pl$" = "whois.dns.pl";
	"\\.pm$" = "whois.nic.pm";
	"\\.pro$" = "whois.registrypro.pro";
	"\\.pt$" = "whois.dns.pt";
	"\\.pw$" = "whois.nic.pw";
	"\\.re$" = "whois.nic.re";
	"\\.ro$" = "whois.rotld.ro";
	"\\.ru$" = "whois.ripn.net";
	"\\.rw$" = "www.nic.rw";
	"\\.sa$" = "saudinic.net.sa";
	"\\.se$" = "whois.iis.se";
	"\\.sg$" = "whois.nic.net.sg";
	"\\.sh$" = "whois.nic.sh";
	"\\.si$" = "whois.arnes.si";
	"\\.sj$" = "whois.ripe.net";
	"\\.sk$" = "whois.ripe.net";
	"\\.sm$" = "whois.ripe.net";
	"\\.sr$" = "whois.register.sr";
	"\\.st$" = "whois.nic.st";
	"\\.su$" = "whois.ripn.net";
	"\\.tc$" = "whois.adamsnames.tc";
	"\\.tf$" = "whois.afnic.fr";
	"\\.tg$" = "www.nic.tg";
	"\\.th$" = "whois.thnic.net";
	"\\.tj$" = "whois.nic.tj";
	"\\.tk$" = "whois.dot.tk";
	"\\.tl$" = "whois.nic.tl";
	"\\.tm$" = "whois.nic.tm";
	"\\.tn$" = "whois.ripe.net";
	"\\.to$" = "whois.tonic.to";
	"\\.tr$" = "whois.nic.tr";
	"\\.tt$" = "www.nic.tt";
	"\\.tv$" = "whois.nic.tv";
	"\\.tw$" = "whois.twnic.net";
	"\\.ua$" = "whois.com.ua";
	"\\.ug$" = "whois.co.ug";
	"\\.ac\\.uk$" = "whois.ja.net";
	"\\.gov\\.uk$" = "whois.ja.net";
	"\\.uk$" = "whois.nic.uk";
	"\\.fed\\.us$" = "whois.nic.gov";
	"\\.us$" = "whois.nic.us";
	"\\.com\\.uy$" = "dns.antel.net.uy";
	"\\.uy$" = "www.rau.edu.uy"; # is a whois server
	"\\.uz$" = "www.noc.uz";
	"\\.va$" = "whois.ripe.net";
	"\\.ve$" = "whois.nic.ve";
	"\\.vi$" = "www.nic.vi";
	"\\.vg$" = "whois.adamsnames.tc";
	"\\.vn$" = "www.vnnic.net.vn";
	"\\.vu$" = "www.vunic.vu";
	"\\.wf$" = "whois.nic.wf";
	"\\.ws$" = "whois.worldsite.ws";
	"\\.yt$" = "whois.nic.yt";
	"\\.yu$" = "whois.ripe.net";
	"\\.ac\\.za$" = "whois.ac.za";
	"\\.org\\.za$" = "rwhois.org.za 4321";
	"\\.co\\.za$" = "whois.co.za";
	# "\\.za$" = "whois.frd.ac.za";

	#
	# Specify different port numbers to connect to by postfixing the IP
	# number or host with a space and the designated port. Default is to
	# use the whois port from /etc/services.
	#
	# ".*" = "whois.internic.net 666";

	default {
		whois-server = "whois.internic.net";
		# Make sure we only match on domain names
		query-format = "domain $*";
	}
}

#
# cidr-blocks contains a list of all known CIDR blocks assigned to
# RIPE or APNIC. Default all queries to ARIN which has most other blocks.
#
# see http://www.iana.org/assignments/ipv4-address-space
#
cidr-blocks {
	type = cidr;

# Note: JPNIC doesn't appear to publish lists of netblocks on their
#       website - this data was derived by searching for "Japan Network
#       Information Center" in the ARIN and APNIC databases.  It may
#       not be complete.

	"61.112.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"61.192.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"61.208.0.0/13" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"133.0.0.0/8" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANB-INET
	"150.100.0.0/16" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.1.0.0/16" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.16.0.0/12" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.2.0.0/15" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.32.0.0/11" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.4.0.0/14" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.64.0.0/11" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.8.0.0/13" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"150.96.0.0/14" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN2
	"158.198.0.0/15" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET-1
	"158.200.0.0/13" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET-1
	"158.208.0.0/13" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET-1
	"158.216.0.0/15" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET-1
	"163.130.0.0/15" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET
	"163.132.0.0/14" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET
	"163.136.0.0/13" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET
	"163.144.0.0/14" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET
	"163.148.0.0/15" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-NET
	"192.218.0.0/16" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANC-INET-BLOCK1
	"192.244.0.0/16" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPAN-INET-C
	"192.41.192.0/24" = "whois.nic.ad.jp";	# ARIN NET-UTOKYO-CON1
	"192.47.0.0/17" = "whois.nic.ad.jp";	# ARIN NETBLK-KIT-BLOCK
	"192.47.128.0/18" = "whois.nic.ad.jp";	# ARIN NETBLK-KIT-BLOCK
	"192.47.142.0/24" = "whois.nic.ad.jp";	# ARIN ITC-JP2
	"192.47.192.0/19" = "whois.nic.ad.jp";	# ARIN NETBLK-KIT-BLOCK
	"192.47.224.0/20" = "whois.nic.ad.jp";	# ARIN NETBLK-KIT-BLOCK
	"192.47.240.0/23" = "whois.nic.ad.jp";	# ARIN NETBLK-KIT-BLOCK
	"192.51.128.0/17" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANC-INET4
	"192.51.16.0/20" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANC-INET4
	"192.51.32.0/19" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANC-INET4
	"192.51.64.0/18" = "whois.nic.ad.jp";	# ARIN NETBLK-JAPANC-INET4
	"202.11.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.13.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.15.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.16.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.23.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.24.0.0/15" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.26.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.32.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.48.0.0/16" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.208.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"202.224.0.0/11" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"203.136.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"203.140.0.0/15" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"203.178.0.0/15" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"203.180.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.128.0.0/11" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.136.0.0/13" = "whois.nic.ad.jp";
	"210.160.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.188.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.196.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.224.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"210.248.0.0/13" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"211.0.0.0/12" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"211.16.0.0/14" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"211.52.0.0/14" = "whois.nic.or.kr";
	"211.56.0.0/13" = "whois.nic.or.kr";
	"211.104.0.0/13" = "whois.nic.or.kr";
	"211.112.0.0/13" = "whois.nic.or.kr";
	"211.120.0.0/13" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"211.128.0.0/13" = "whois.nic.ad.jp";	# APNIC JPNIC-NET-JP
	"211.172.0.0/14" = "whois.nic.or.kr";
	"211.176.0.0/12" = "whois.nic.or.kr";
	"211.192.0.0/13" = "whois.nic.or.kr";
	"219.96.0.0/11" = "whois.nic.ad.jp";
	"220.104.0.0/13" = "whois.nic.ad.jp";
	"220.208.0.0/12" = "whois.nic.ad.jp";
	"221.112.0.0/13" = "whois.nic.ad.jp";

	"24.132.0.0/16" = "whois.ripe.net";
	"24.232.0.0/16" = "whois.lacnic.net";
	"41.0.0.0/8" = "whois.afrinic.net";
	"43.0.0.0/8" = "whois.v6nic.net";
	"58.0.0.0/8" = "whois.apnic.net";
	"59.0.0.0/8" = "whois.apnic.net";
	"60.0.0.0/8" = "whois.apnic.net";
	"61.0.0.0/8" = "whois.apnic.net";
	"62.135.36.0/17" = "whois.afrinic.net";
	"62.0.0.0/8" = "whois.ripe.net";
	"80.87.64.0/19" = "whois.afrinic.net";
	"80.0.0.0/8" = "whois.ripe.net";
	"81.91.224.0/20" = "whois.afrinic.net";
	"81.192.0.0/16" = "whois.afrinic.net";
	"81.0.0.0/8" = "whois.ripe.net";
	"82.101.128.0/18" = "whois.afrinic.net";
	"82.201.128.0/17" = "whois.afrinic.net";
	"82.201.160.0/19" = "whois.afrinic.net";
	"82.201.224.0/19" = "whois.afrinic.net";
	"82.0.0.0/8" = "whois.ripe.net";
	"83.0.0.0/8" = "whois.ripe.net";
	"84.36.0.0/17" = "whois.afrinic.net";
	"84.0.0.0/8" = "whois.ripe.net";
	"85.0.0.0/8" = "whois.ripe.net";
	"86.0.0.0/8" = "whois.ripe.net";
	"87.0.0.0/8" = "whois.ripe.net";
	"88.0.0.0/8" = "whois.ripe.net";
	"89.0.0.0/8" = "whois.ripe.net";
	"90.0.0.0/8" = "whois.ripe.net";
	"91.0.0.0/8" = "whois.ripe.net";
	"121.0.0.0/8" = "whois.apnic.net";
	"122.0.0.0/8" = "whois.apnic.net";
	"123.0.0.0/8" = "whois.apnic.net";
	"124.0.0.0/8" = "whois.apnic.net";
	"125.0.0.0/8" = "whois.apnic.net";
	"126.0.0.0/8" = "whois.apnic.net";
	"129.132.0.0/16" = "whois.ripe.net";
	"129.177.0.0/16" = "whois.ripe.net";
	"129.187.0.0/16" = "whois.ripe.net";
	"130.225.0.0/16" = "whois.ripe.net";
	"130.226.0.0/15" = "whois.ripe.net";
	"130.227.0.0/16" = "whois.ripe.net";
	"130.228.0.0/14" = "whois.ripe.net";
	"130.232.0.0/13" = "whois.ripe.net";
	"130.240.0.0/14" = "whois.ripe.net";
	"130.244.0.0/16" = "whois.ripe.net";
	"130.244.0.0/16" = "whois.ripe.net";
	"132.64.0.0/13" = "whois.ripe.net";
	"132.72.0.0/14" = "whois.ripe.net";
	"132.76.0.0/15" = "whois.ripe.net";
	"132.78.0.0/16" = "whois.ripe.net";
	"137.138.0.0/16" = "whois.ripe.net";
	"138.130.0.0/16" = "whois.apnic.net";
	"140.109.0.0/16" = "whois.apnic.net";
	"140.110.0.0/15" = "whois.apnic.net";
	"140.112.0.0/12" = "whois.apnic.net";
	"140.116.0.0/14" = "whois.apnic.net";
	"140.120.0.0/13" = "whois.apnic.net";
	"140.128.0.0/13" = "whois.apnic.net";
	"140.136.0.0/15" = "whois.apnic.net";
	"140.138.0.0/16" = "whois.apnic.net";
	"141.223.0.0/16" = "whois.apnic.net";
	"143.89.0.0/16" = "whois.apnic.net";
	"143.90.0.0/16" = "whois.apnic.net";
	"144.130.0.0/15" = "whois.apnic.net";
	"144.132.0.0/14" = "whois.apnic.net";
	"144.136.0.0/14" = "whois.apnic.net";
	"144.140.0.0/16" = "whois.apnic.net";
	"145.0.0.0/8" = "whois.ripe.net";
	"147.46.0.0/15" = "whois.apnic.net";
	"150.1.0.0/16" = "whois.apnic.net";
	"150.2.0.0/15" = "whois.apnic.net";
	"150.4.0.0/14" = "whois.apnic.net";
	"150.8.0.0/13" = "whois.apnic.net";
	"150.16.0.0/12" = "whois.apnic.net";
	"150.32.0.0/11" = "whois.apnic.net";
	"150.64.0.0/11" = "whois.apnic.net";
	"150.96.0.0/14" = "whois.apnic.net";
	"150.100.0.0/15" = "whois.apnic.net";
	"150.217.0.0/16" = "whois.ripe.net";
	"151.3.0.0/16" = "whois.ripe.net";
	"151.4.0.0/15" = "whois.ripe.net";
	"151.10.0.0/15" = "whois.ripe.net";
	"151.12.0.0/14" = "whois.ripe.net";
	"151.16.0.0/12" = "whois.ripe.net";
	"151.32.0.0/11" = "whois.ripe.net";
	"151.64.0.0/11" = "whois.ripe.net";
	"151.96.0.0/14" = "whois.ripe.net";
	"151.100.0.0/16" = "whois.ripe.net";
	"155.230.0.0/16" = "whois.apnic.net";
	"158.190.0.0/15" = "whois.ripe.net";
	"158.192.0.0/14" = "whois.ripe.net";
	"158.196.0.0/15" = "whois.ripe.net";
	"159.147.0.0/16" = "whois.ripe.net";
	"159.148.0.0/15" = "whois.ripe.net";
	"160.216.0.0/14" = "whois.ripe.net";
	"160.220.0.0/16" = "whois.ripe.net";
	"161.110.0.0/15" = "whois.ripe.net";
	"161.112.0.0/16" = "whois.ripe.net";
	"163.13.0.0/16" = "whois.apnic.net";
	"163.14.0.0/15" = "whois.apnic.net";
	"163.16.0.0/12" = "whois.apnic.net";
	"163.32.0.0/16" = "whois.apnic.net";
	"163.156.0.0/14" = "whois.ripe.net";
	"163.160.0.0/12" = "whois.ripe.net";
	"164.0.0.0/11" = "whois.ripe.net";
	"164.32.0.0/13" = "whois.ripe.net";
	"164.40.0.0/16" = "whois.ripe.net";
	"164.100.0.0/16" = "whois.apnic.net";
	"164.128.0.0/12" = "whois.ripe.net";
	"164.160.0.0/14" = "whois.apnic.net";
	"164.164.0.0/16" = "whois.apnic.net";
	"165.21.0.0/16" = "whois.apnic.net";
	"165.76.0.0/16" = "whois.apnic.net";
	"165.165.0.0/16" = "whois.afrinic.net";
	"165.228.0.0/15" = "whois.apnic.net";
	"168.95.0.0/16" = "whois.apnic.net";
	"168.126.0.0/16" = "whois.apnic.net";
	"168.187.0.0/16" = "whois.ripe.net";
	"169.208.0.0/16" = "whois.apnic.net";
	"171.16.0.0/12" = "whois.ripe.net";
	"171.32.0.0/15" = "whois.ripe.net";
	"189.0.0.0/8" = "whois.lacnic.net";
	"190.0.0.0/8" = "whois.lacnic.net";
	"196.0.0.0/8" = "whois.afrinic.net";
	"192.16.192.0/24" = "whois.ripe.net";
	"192.114.0.0/15" = "whois.ripe.net";
	"192.116.0.0/15" = "whois.ripe.net";
	"192.118.0.0/16" = "whois.ripe.net";
	"192.140.1.0/24" = "whois.ripe.net";
	"192.140.2.0/23" = "whois.ripe.net";
	"192.140.4.0/22" = "whois.ripe.net";
	"192.140.8.0/21" = "whois.ripe.net";
	"192.140.16.0/20" = "whois.ripe.net";
	"192.140.32.0/19" = "whois.ripe.net";
	"192.140.64.0/18" = "whois.ripe.net";
	"192.140.128.0/17" = "whois.ripe.net";
	"192.141.0.0/16" = "whois.ripe.net";
	"192.142.0.0/15" = "whois.ripe.net";
	"192.144.0.0/16" = "whois.ripe.net";
	"192.145.0.0/17" = "whois.ripe.net";
	"192.145.128.0/18" = "whois.ripe.net";
	"192.145.192.0/19" = "whois.ripe.net";
	"192.145.224.0/22" = "whois.ripe.net";
	"192.145.228.0/23" = "whois.ripe.net";
	"192.145.230.0/24" = "whois.ripe.net";
	"192.164.0.0/16" = "whois.ripe.net";
	"193.0.0.0/8" = "whois.ripe.net";
	"194.0.0.0/8" = "whois.ripe.net";
	"195.166.224.0/19" = "whois.afrinic.net";
	"195.0.0.0/8" = "whois.ripe.net";
	"196.2.96.0/19" = "whois.afrinic.net";
	"196.2.128.0/17" = "whois.afrinic.net";
	"196.200.0.0/13" = "whois.afrinic.net";
	"200.17.0.0/16" = "whois.nic.br";
	"200.128.0.0/9" = "whois.nic.br";
	"200.0.0.0/8" = "whois.lacnic.net";
	"201.0.0.0/8" = "whois.lacnic.net";
	"202.0.0.0/8" = "whois.apnic.net";
	"203.0.0.0/8" = "whois.apnic.net";
	"210.0.0.0/8" = "whois.apnic.net";
	"211.0.0.0/8" = "whois.apnic.net";
	"212.22.160.0/19" = "whois.afrinic.net";
	"212.0.0.0/8" = "whois.ripe.net";
	"213.136.96.0/19" = "whois.afrinic.net";
	"213.154.64.0/19" = "whois.afrinic.net";
	"213.0.0.0/8" = "whois.ripe.net";
	"217.0.0.0/8" = "whois.ripe.net";
	"218.0.0.0/8" = "whois.apnic.net";
	"219.0.0.0/8" = "whois.apnic.net";
	"220.0.0.0/8" = "whois.apnic.net";
	"221.0.0.0/8" = "whois.apnic.net";
	"222.0.0.0/8" = "whois.apnic.net";

	default = "whois.arin.net";
}

#
# Handles for the various registries.
#
handles {
	type = regex;

	"^!?NET\\(BLK\\)?\\(-[A-Z0-9]+\\)+$" = "whois.arin.net";

	"^COCO-[0-9]+$" = "whois.corenic.net";
	"^CORE-[0-9]+$" = "whois.corenic.net";
	"^COHO-[0-9]+$" = "whois.corenic.net";

	".*-RIPE$" = "whois.ripe.net";
	".*-MNT$" = "whois.ripe.net";
	".*-ARIN$" = "whois.arin.net";
	".*-AP$" = "whois.apnic.net";
	".*-ORG$" = "whois.internic.net";
	".*-DOM$" = "whois.internic.net";
	".*-NORID$" = "whois.norid.no";
	".*-GANDI$" = "whois.gandi.net";
	".*-AU$" = "whois.aunic.net";
	".*-CKNIC" = "whois.nic.ck";
	".*-IDNIC$" = "whois.idnic.net.id";
	".*-KG$" = "whois.domain.kg";
	".*-NICAT$" = "whois.nic.at";
	".*-CZ$" = "whois.nic.cz";
	".*-NICIR$" = "whois.nic.ir";
	".*-UYNIC$" = "www.rau.edu.uy";
	".*-ITNIC$" = "whois.nic.it";
	".*-FRNIC$" = "whois.nic.fr";
	".*-LACNIC$" = "whois.lacnic.net";
	".*-DK$" = "whois.dk-hostmaster.dk";
	".*-SA$" {
		whois-server = "saudinic.net.sa";
		query-format = "PERSON $*";
	}
}

#
# The server-options block defines a number of options specific for
# each host.
#
server-options {
	"rwhois\\.nic\\.ve" {
		rwhois = true;
		rwhois-display = "dump";
		rwhois-limit = 10;
	}
	"rwhois\\.exodus\\.net" {
		rwhois = true;
	}
	"whois\\.publicinterestregistry\\.net" {
		whois-redirect = ".*Whois Server:\\(.*\\)";
	}
	".*\\.internic\\.net" {
		#
		# This will match output from whois.internic.net. The
		# parenteses must be escaped and should enclose the hostname
		# to which to redirect the search.
		#
		whois-redirect = ".*Whois Server: \\(.*\\)";
	}

	"whois\\.crsnic\\.net" {
		whois-redirect = ".*Whois Server: \\(.*\\)";
	}

	"whois\\.apnic\\.net" {
		whois-redirect = ".*http://\\(whois\\.nic\\.or\\.kr\\)/";
		whois-redirect = ".*at \\([Ww][Hh][Oo][Ii][Ss]\\.[A-Za-z]*\\.[Nn][Ee][Tt]\\)";
	}

	"whois\\.arin\\.net" {
		#
		# Content redirection for whois.arin.net - allows redirection
		# of European and Asia-Pacific addresses to the appropriate
		# servers.
		#
		whois-redirect = ".*at \\([Ww][Hh][Oo][Ii][Ss]\\.[A-Za-z]*\\.[Nn][Ee][Tt]\\)";
		whois-redirect = ".* \\([Rr]+[Ww][Hh][Oo][Ii][Ss]\\.[A-Za-z]*\\.[Nn][Ee][Tt]\\) \\([0-9]*\\)";
		whois-redirect = ".* r?whois://\\([^:]*\\):?\\([0-9]*\\)?/?";
	}

	"whois\\.ncst\\.ernet\\.in" {
		# query-format defines how to format a whois query.
		# The special variable $* will be replaced by
		# the query as specified by the user.
		query-format = "domain $*";
	}

	".*\\.connect\\.com\\.au" {
		#
		# Referals from the net.au whois server.
		#
		whois-redirect =  ".*referto: whois -h \\([^ ]*\\) -p \\([0-9]*\\)";
	}

	"whois\\.co\\.za" {
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/whois.sh";
		form-element = "Domain";			# <input> element
	}

	"www\\.nic\\.es" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/consulta.whois";
		form-element = "key";
		form-extra = "list=Dominios&tipo=procesar";	# Other <input> elements
	}

	"www\\.nic\\.tt" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/search.pl";
		form-element = "name";
	}

	"www\\.um\\.edu\\.mt" {
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/nic/whois";
		form-element = "domain";
	}

	"www\\.gt" {
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/whois.cgi";
		form-element = "domain";
	}

	# This uses an advanced query using the query-format syntax.
	# query-format cannot be combined with form-element or form-extra.
	"www\\.dns\\.hr" {
		http = "true";
		http-method = "POST";
		http-action = "/asp/trazidomenu.asp";
		query-format = "Upit=${+2}"; # All but last domain segment
	}

	"whois\\.offshore\\.ai" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/whois.pl";
		form-element = "domain-name";
	}

	"www\\.io\\.io" {
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/whois";
		form-element = "query";
	}

	"www\\.nic\\.ec" {
		http = "true";
		http-method = "GET";
		http-action = "/consulta/whois.asp";
		form-element = "dominio";
	}

	"www\\.nic\\.gi" {
		http = "true";  # At least, I can't connect on port 43
		http-method = "POST";
		http-action = "/whois/";
		form-element = "lookup";
	}

	"www\\.nic\\.kz" {
		# whois.nic.kz exists but wasn't checkable
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/whois";
		form-element = "query";
	}

	"www\\.nic\\.bi" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/whoisbi.pl"; # Formatting problems in Lynx
		form-element = "DOMAINWHOIS";
	}

	"www\\.nic\\.cg" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/whoiscg.pl"; # Formatting problems in Lynx
		form-element = "DOMAINWHOIS";
	}

	"www\\.nic\\.rw" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/whoisrw.pl"; # Formatting problems in Lynx
		form-element = "DOMAINWHOIS";
	}

	"www\\.tarsus\\.net" {
		http = "true";
		http-method = "POST";
		http-action = "/whois/NameSearch.asp";
		form-element = "searchfor";
	}

	"pknic\\.net\\.pk" {
		http = "true";
		http-method = "POST";
		http-action = "/cgi-bin/pknic-db/display.html";
		form-element = "name";
	}

	"www\\.noc\\.uz" {
		http = "true";
		http-method = "POST";
		http-action = "/whois.php4";
		form-element = "dname";
	}

	"www\\.nic\\.vi" {
		http = "true";
		http-method = "POST";
		http-action = "/whois.asp";
		form-element = "text1";
	}

	"www\\.vnnic\\.net\\.vn" {
		http = "true";
		http-method = "GET";
		http-action = "/dk_tenmien/jsp/whois/whoisdomain_detail.jsp";
		form-element = "type";
	}

	"dns\\.antel\\.net\\.uy" {
		http = "true";
		http-method = "POST";
		http-action = "/public-servlets/buscarDominio";
		form-element = "nomReg";
	}

	"www\\.nic\\.tg" {
		http = "true";
		http-method = "GET";
		http-action = "/moteur/info_dom.php";
		form-element = "domaine";
	}

	"cgi\\.aub\\.edu\\.lb" {
		http = "true";
		http-method = "GET";
		http-action = "/cgi-bin/lbdr.pl";
		form-element = "cn";
	}

	"www\\.vunic\\.vu" {
		http = "true";
		http-method = "POST";
		http-action = "/whois";
		form-element = "whois";
	}

	"whois\\.lacnic\\.net" {
		whois-redirect = ".*\\(whois.nic.br\\)";
		whois-redirect = ".*\\(whois.registro.br\\)";
		whois-redirect = ".* \\([Rr]+[Ww][Hh][Oo][Ii][Ss]\\.[A-Za-z]*\\.[Nn][Ee][Tt]\\) port \\([0-9]*\\)";
	}

	"www\\.nic\\.ar" {
		http = "true";
		http-method = "POST";
		http-action = "/consultas/consdom.html";
		form-element = "nombre";
	}

	"www\\.denic\\.de" {
		http = "true";
		http-method = "POST";
		http-action = "/en/whois/data.jsp";
		form-element = "domainname";
		form-extra = "service=WhoisData&lang=en&submit=Accept";
	}

	"whois\\.denic\\.de" {
		whois-server = "whois.denic.de";
		query-format = "-C UTF-8 -T dn,ace $*";
		answer-charset = "UTF-8";
	}

	"whois\\.enum\\.denic\\.de" {
		whois-server = "whois.enum.denic.de";
		query-format = "-C UTF-8 -T dn $*";
		answer-charset = "UTF-8";
	}

	"whois\\.nic\\.ad\\.jp" {
		query-format = "$*/e";
	}

	"whois\\.nic\\.ch" {
		answer-charset = "UTF-8";
	}

	"whois\\.nic\\.li" {
		answer-charset = "UTF-8";
	}

	"whois\\.centralnic\\.*" {
		whois-redirect = ".*Whois Server: \\(.*\\)";
	}

	".*\\.verisign-grs\\.com" {
		whois-redirect = ".*Whois Server: \\(.*\\)";
	}
}

#
# The cache feature is used to provide a local cache with Whois information.
# By default, the location of the database is /usr/local/var/jwhois.db and the
# default expire time is 7 days, but you can change those below.
#
#cachefile = "/var/lib/jwhois.db";

#
# This is the time after which an entry expires from the cache in hours.
#
#cacheexpire = 168;

#
# If you're using the whois-servers support, you can specify this option
# to override the compiled in domain for that service.
#
#whois-servers-domain = "whois-servers.net";

#
# Path to the browser to use for HTTP servers.
#
browser-pathname = "/usr/bin/lynx";

#
# Command line argument to browser to get output on stdout.
#
browser-stdarg = "-dump";

#
# Command line argument to browser to perform a POST operation.
# Jwhois currently supports the format used by Lynx and W3M.
#
browser-postarg = "-post_data";

#
# Select the method for which Jwhois sends POST data to the browser.
# If post-as-file is false, Jwhois will send the data on stdin
# terminated with three dashes on an empty line, i.e the format that
# Lynx expects.
# If post-as-file is true, Jwhois will create a temporary file with
# the post data and send the file name after the browser-postarg
# parameter, i.e the format that W3M expects.
#
post-as-file = "false";

#
# To use w3m instead of Lynx, use this configuration:
#
# browser-pathname = "/usr/bin/w3m";
# browser-stdarg = "-dump";
# browser-postarg = "-post";
# post-as-file = "true";
#

Back to top

/etc/krb5.conf File

 -rw-r--r-- 1 root root 608  Feb 10 21:18 2011  Jun 25 05:59 2007  krb5.conf
[logging]
 default = FILE:/var/log/krb5libs.log
 kdc = FILE:/var/log/krb5kdc.log
 admin_server = FILE:/var/log/kadmind.log

[libdefaults]
 default_realm = EXAMPLE.COM
 dns_lookup_realm = false
 dns_lookup_kdc = false
 ticket_lifetime = 24h
 forwardable = yes

[realms]
 EXAMPLE.COM = {
  kdc = kerberos.example.com:88
  admin_server = kerberos.example.com:749
  default_domain = example.com
 }

[domain_realm]
 .example.com = EXAMPLE.COM
 example.com = EXAMPLE.COM

[appdefaults]
 pam = {
   debug = false
   ticket_lifetime = 36000
   renew_lifetime = 36000
   forwardable = true
   krb4_convert = false
 }

Back to top

/etc/ld.so.conf File

 -rw-r--r-- 1 root root 28  Apr 29 06:48 2011  Oct  8 13:04 2006  ld.so.conf
include ld.so.conf.d/*.conf

Back to top

/etc/ldap.conf File

 -rw-r--r-- 1 root root 9111  Feb 10 21:12 2011  Feb 10 21:12 2011  ldap.conf
# @(#)$Id: ldap.conf,v 1.38 2006/05/15 08:13:31 lukeh Exp $
#
# This is the configuration file for the LDAP nameservice
# switch library and the LDAP PAM module.
#
# The man pages for this file are nss_ldap(5) and pam_ldap(5)
#
# PADL Software
# http://www.padl.com
#

# Your LDAP server. Must be resolvable without using LDAP.
# Multiple hosts may be specified, each separated by a
# space. How long nss_ldap takes to failover depends on
# whether your LDAP client library supports configurable
# network or connect timeouts (see bind_timelimit).
#host 127.0.0.1

# The distinguished name of the search base.
base dc=example,dc=com

# Another way to specify your LDAP server is to provide an
# uri with the server name. This allows to use
# Unix Domain Sockets to connect to a local LDAP Server.
#uri ldap://127.0.0.1/
#uri ldaps://127.0.0.1/
#uri ldapi://%2fvar%2frun%2fldapi_sock/
# Note: %2f encodes the '/' used as directory separator

# The LDAP version to use (defaults to 3
# if supported by client library)
#ldap_version 3

# The distinguished name to bind to the server with.
# Optional: default is to bind anonymously.
#binddn cn=proxyuser,dc=example,dc=com

# The credentials to bind with.
# Optional: default is no credential.
#bindpw secret

# The distinguished name to bind to the server with
# if the effective user ID is root. Password is
# stored in /etc/ldap.secret (mode 600)
#rootbinddn cn=manager,dc=example,dc=com

# The port.
# Optional: default is 389.
#port 389

# The search scope.
#scope sub
#scope one
#scope base

# Search timelimit
#timelimit 30
timelimit 120

# Bind/connect timelimit
#bind_timelimit 30
bind_timelimit 120

# Reconnect policy: hard (default) will retry connecting to
# the software with exponential backoff, soft will fail
# immediately.
#bind_policy hard

# Idle timelimit; client will close connections
# (nss_ldap only) if the server has not been contacted
# for the number of seconds specified below.
#idle_timelimit 3600
idle_timelimit 3600

# Filter to AND with uid=%s
#pam_filter objectclass=account

# The user ID attribute (defaults to uid)
#pam_login_attribute uid

# Search the root DSE for the password policy (works
# with Netscape Directory Server)
#pam_lookup_policy yes

# Check the 'host' attribute for access control
# Default is no; if set to yes, and user has no
# value for the host attribute, and pam_ldap is
# configured for account management (authorization)
# then the user will not be allowed to login.
#pam_check_host_attr yes

# Check the 'authorizedService' attribute for access
# control
# Default is no; if set to yes, and the user has no
# value for the authorizedService attribute, and
# pam_ldap is configured for account management
# (authorization) then the user will not be allowed
# to login.
#pam_check_service_attr yes

# Group to enforce membership of
#pam_groupdn cn=PAM,ou=Groups,dc=example,dc=com

# Group member attribute
#pam_member_attribute uniquemember

# Specify a minium or maximum UID number allowed
#pam_min_uid 0
#pam_max_uid 0

# Template login attribute, default template user
# (can be overriden by value of former attribute
# in user's entry)
#pam_login_attribute userPrincipalName
#pam_template_login_attribute uid
#pam_template_login nobody

# HEADS UP: the pam_crypt, pam_nds_passwd,
# and pam_ad_passwd options are no
# longer supported.
#
# Do not hash the password at all; presume
# the directory server will do it, if
# necessary. This is the default.
#pam_password clear

# Hash password locally; required for University of
# Michigan LDAP server, and works with Netscape
# Directory Server if you're using the UNIX-Crypt
# hash mechanism and not using the NT Synchronization
# service.
#pam_password crypt

# Remove old password first, then update in
# cleartext. Necessary for use with Novell
# Directory Services (NDS)
#pam_password clear_remove_old
#pam_password nds

# RACF is an alias for the above. For use with
# IBM RACF
#pam_password racf

# Update Active Directory password, by
# creating Unicode password and updating
# unicodePwd attribute.
#pam_password ad

# Use the OpenLDAP password change
# extended operation to update the password.
#pam_password exop

# Redirect users to a URL or somesuch on password
# changes.
#pam_password_prohibit_message Please visit http://internal to change your password.

# RFC2307bis naming contexts
# Syntax:
# nss_base_XXX		base?scope?filter
# where scope is {base,one,sub}
# and filter is a filter to be &'d with the
# default filter.
# You can omit the suffix eg:
# nss_base_passwd	ou=People,
# to append the default base DN but this
# may incur a small performance impact.
#nss_base_passwd	ou=People,dc=example,dc=com?one
#nss_base_shadow	ou=People,dc=example,dc=com?one
#nss_base_group		ou=Group,dc=example,dc=com?one
#nss_base_hosts		ou=Hosts,dc=example,dc=com?one
#nss_base_services	ou=Services,dc=example,dc=com?one
#nss_base_networks	ou=Networks,dc=example,dc=com?one
#nss_base_protocols	ou=Protocols,dc=example,dc=com?one
#nss_base_rpc		ou=Rpc,dc=example,dc=com?one
#nss_base_ethers	ou=Ethers,dc=example,dc=com?one
#nss_base_netmasks	ou=Networks,dc=example,dc=com?ne
#nss_base_bootparams	ou=Ethers,dc=example,dc=com?one
#nss_base_aliases	ou=Aliases,dc=example,dc=com?one
#nss_base_netgroup	ou=Netgroup,dc=example,dc=com?one

# Just assume that there are no supplemental groups for these named users
nss_initgroups_ignoreusers root,ldap,named,avahi,haldaemon,dbus,radvd,tomcat,radiusd,news,mailman,nscd,gdm

# attribute/objectclass mapping
# Syntax:
#nss_map_attribute	rfc2307attribute	mapped_attribute
#nss_map_objectclass	rfc2307objectclass	mapped_objectclass

# configure --enable-nds is no longer supported.
# NDS mappings
#nss_map_attribute uniqueMember member

# Services for UNIX 3.5 mappings
#nss_map_objectclass posixAccount User
#nss_map_objectclass shadowAccount User
#nss_map_attribute uid msSFU30Name
#nss_map_attribute uniqueMember msSFU30PosixMember
#nss_map_attribute userPassword msSFU30Password
#nss_map_attribute homeDirectory msSFU30HomeDirectory
#nss_map_attribute homeDirectory msSFUHomeDirectory
#nss_map_objectclass posixGroup Group
#pam_login_attribute msSFU30Name
#pam_filter objectclass=User
#pam_password ad

# configure --enable-mssfu-schema is no longer supported.
# Services for UNIX 2.0 mappings
#nss_map_objectclass posixAccount User
#nss_map_objectclass shadowAccount user
#nss_map_attribute uid msSFUName
#nss_map_attribute uniqueMember posixMember
#nss_map_attribute userPassword msSFUPassword
#nss_map_attribute homeDirectory msSFUHomeDirectory
#nss_map_attribute shadowLastChange pwdLastSet
#nss_map_objectclass posixGroup Group
#nss_map_attribute cn msSFUName
#pam_login_attribute msSFUName
#pam_filter objectclass=User
#pam_password ad

# RFC 2307 (AD) mappings
#nss_map_objectclass posixAccount user
#nss_map_objectclass shadowAccount user
#nss_map_attribute uid sAMAccountName
#nss_map_attribute homeDirectory unixHomeDirectory
#nss_map_attribute shadowLastChange pwdLastSet
#nss_map_objectclass posixGroup group
#nss_map_attribute uniqueMember member
#pam_login_attribute sAMAccountName
#pam_filter objectclass=User
#pam_password ad

# configure --enable-authpassword is no longer supported
# AuthPassword mappings
#nss_map_attribute userPassword authPassword

# AIX SecureWay mappings
#nss_map_objectclass posixAccount aixAccount
#nss_base_passwd ou=aixaccount,?one
#nss_map_attribute uid userName
#nss_map_attribute gidNumber gid
#nss_map_attribute uidNumber uid
#nss_map_attribute userPassword passwordChar
#nss_map_objectclass posixGroup aixAccessGroup
#nss_base_group ou=aixgroup,?one
#nss_map_attribute cn groupName
#nss_map_attribute uniqueMember member
#pam_login_attribute userName
#pam_filter objectclass=aixAccount
#pam_password clear

# Netscape SDK LDAPS
#ssl on

# Netscape SDK SSL options
#sslpath /etc/ssl/certs

# OpenLDAP SSL mechanism
# start_tls mechanism uses the normal LDAP port, LDAPS typically 636
#ssl start_tls
#ssl on

# OpenLDAP SSL options
# Require and verify server certificate (yes/no)
# Default is to use libldap's default behavior, which can be configured in
# /etc/openldap/ldap.conf using the TLS_REQCERT setting.  The default for
# OpenLDAP 2.0 and earlier is "no", for 2.1 and later is "yes".
#tls_checkpeer yes

# CA certificates for server certificate verification
# At least one of these are required if tls_checkpeer is "yes"
#tls_cacertfile /etc/ssl/ca.cert
#tls_cacertdir /etc/ssl/certs

# Seed the PRNG if /dev/urandom is not provided
#tls_randfile /var/run/egd-pool

# SSL cipher suite
# See man ciphers for syntax
#tls_ciphers TLSv1

# Client certificate and key
# Use these, if your server requires client authentication.
#tls_cert
#tls_key

# Disable SASL security layers. This is needed for AD.
#sasl_secprops maxssf=0

# Override the default Kerberos ticket cache location.
#krb5_ccname FILE:/etc/.ldapcache

# SASL mechanism for PAM authentication - use is experimental
# at present and does not support password policy control
#pam_sasl_mech DIGEST-MD5
uri ldap://127.0.0.1/
ssl no
tls_cacertdir /etc/openldap/cacerts
pam_password md5

Back to top

/etc/lftp.conf File

 -rw-r--r-- 1 root root 3544  Feb 10 21:17 2011  Jul 29 14:39 2010  lftp.conf
## some useful aliases
alias dir ls
alias less more
alias zless zmore
alias bzless bzmore
alias reconnect "close; cache flush; cd ."
alias edit "eval -f \"get '$0' -o ~/.lftp/edit.tmp.$$ && shell \\\"cp -p ~/.lftp/edit.tmp.$$ ~/.lftp/edit.tmp.$$.orig && ${EDITOR:-vi} ~/.lftp/edit.tmp.$$ && test ~/.lftp/edit.tmp.$$ -nt ~/.lftp/edit.tmp.$$.orig\\\" && put ~/.lftp/edit.tmp.$$ -o '$0'; shell rm -f ~/.lftp/edit.tmp.$$*\""

## make prompt look better
set prompt "lftp \S\? \u\@\h:\w> "
## some may prefer colors (contributed by Matthew <mwormald@optusnet.com.au>)
#set prompt "\[\e[1;30m\][\[\e[0;34m\]f\[\e[1m\]t\[\e[37m\]p\[\e[30m\]] \[\e[34m\]\u\[\e[0;34m\]\@\[\e[1m\]\h\[\e[1;30m\]:\[\e[1;34m\]\w\[\e[1;30m\]>\[\e[0m\] "
## Uncomment the following two lines to make switch cls and ls, making
## cls the default.
#alias ls command cls
#alias hostls command ls

## default protocol selection
#set default-protocol/ftp.*	ftp
#set default-protocol/www.*	http
#set default-protocol/localhost	file

## this makes lftp faster but doesn't work with some sites/routers
#set ftp:sync-mode off

## synchronous mode for broken servers and/or routers
set sync-mode/ftp.idsoftware.com on
set sync-mode/ftp.microsoft.com on
set sync-mode/sunsolve.sun.com on
## extended regex to match first server message for automatic sync-mode.
set auto-sync-mode "icrosoft FTP Service|MadGoat|MikroTik"

## if default ftp passive mode does not work, try this:
# set ftp:passive-mode off

## Set this to follow http redirections
set xfer:max-redirections 10

## Proxy can help to pass a firewall
## Environment variables ftp_proxy, http_proxy and no_proxy are used to
## initialize the below variables automatically. You can set them here too.
##
## ftp:proxy must communicate with client over ftp protocol, squid won't do.
## This can be e.g. TIS-FWTK or rftpd. User and password are optional.
# set ftp:proxy ftp://[user:pass@]your_ftp_proxy:port
## ...but squid still can be used to access ftp servers, using hftp protocol:
# set ftp:proxy http://your.squid.address:port
## ...if squid allows CONNECT to arbitrary ports, then you can use CONNECT
## instead of hftp:
# set ftp:use-hftp no
##
## no proxy for host
# set ftp:proxy/local_host ""
## or domain
# set ftp:proxy/*.domain.com ...
##
## http:proxy must communicate with client over http protocol, e.g. squid.
## Default port is 3128.
# set http:proxy your_http_proxy[:port]
## hftp:proxy must also be an http proxy. It is used for FTP over HTTP access.
# set hftp:proxy your_http_proxy[:port]
##
## net:no-proxy disables proxy usage for list of domains.
# set net:no-proxy .domain.com,.otherdom.net

## If you don't have direct ftp access, this setting can be useful to select
## hftp instead of ftp automatically.
# set ftp:proxy http://your.http.proxy:port

## This can be used for automatic saving of configuration
# set at-exit "set > ~/.lftp/settings"
# source ~/.lftp/settings

## and this is for remembring last site
## (combine with previous rule if you want)
# set at-exit "bo a last"
# open last

## Terminal strings to set titlebars for terminals that don't
## properly specify tsl and fsl capabilities.
## Use cmd:set-term-status to enable this.
set cmd:term-status/*screen* "\e_\T\e\\"
set cmd:term-status/*xterm* "\e[11;0]\e]2;\T\007\e[11]"
set cmd:term-status/*rxvt* "\e[11;0]\e]2;\T\007\e[11]"
# set cmd:set-term-status on

## If you don't like advertising lftp or servers hate it, set this:
# set ftp:anon-pass "mozilla@"
# set ftp:client ""
# set http:user-agent "Mozilla/4.7 [en] (WinNT; I)"

Back to top

/etc/libaudit.conf File

 -rw-r----- 1 root root 191  Feb 10 21:17 2011  Sep 19 19:55 2010  libaudit.conf

Back to top

/etc/libuser.conf File

 -rw-r--r-- 1 root root 2506  Feb 10 21:18 2011  Jan 10 20:30 2011  libuser.conf
# See libuser.conf(5) for more information.

# Do not modify the default module list if you care about unattended calls
# to programs (i.e., scripts) working!

[import]
# Data from these files is used when libuser.conf does not define a value.
# The mapping is documented in the man page.
login_defs = /etc/login.defs
default_useradd = /etc/default/useradd

[defaults]
# The default (/usr/lib*/libuser) is usually correct
# moduledir = /your/custom/directory

# The following variables are usually imported:
# skeleton = /etc/skel
# mailspooldir = /var/mail

crypt_style = md5
modules = files shadow
create_modules = files shadow
# modules = files shadow ldap krb5
# create_modules = ldap krb5

[userdefaults]
LU_USERNAME = %n
# LU_UIDNUMBER = 500
LU_GIDNUMBER = %u
# LU_USERPASSWORD = !!
# LU_GECOS = %n
# LU_HOMEDIRECTORY = /home/%n
# LU_LOGINSHELL = /bin/bash

# LU_SHADOWNAME = %n
# LU_SHADOWPASSWORD = !!
# LU_SHADOWLASTCHANGE = %d
# LU_SHADOWMIN = 0
# LU_SHADOWMAX = 99999
# LU_SHADOWWARNING = 7
# LU_SHADOWINACTIVE = -1
# LU_SHADOWEXPIRE = -1
# LU_SHADOWFLAG = -1

[groupdefaults]
LU_GROUPNAME = %n
# LU_GIDNUMBER = 500
# LU_GROUPPASSWORD = !!
# LU_MEMBERUID =
# LU_ADMINISTRATORUID =

[files]
# This is useful for the case where some master files are used to
# populate a different NSS mechanism which this workstation uses.
# directory = /etc

[shadow]
# This is useful for the case where some master files are used to
# populate a different NSS mechanism which this workstation uses.
# directory = /etc

[ldap]
# Setting these is always necessary.
# server = ldap
# basedn = dc=example,dc=com

# Setting these is rarely necessary, since it's usually correct.
# userBranch = ou=People
# groupBranch = ou=Group

# Set only if your administrative user uses simple bind operations to
# connect to the server.
# binddn = cn=Manager,dc=example,dc=com

# Set this only if the default user (as determined by SASL) is incorrect
# for SASL bind operations.  Usually, it's correct, so you'll rarely need
# to set these.
# user = Manager
# authuser = Manager

[krb5]
# Set this only if it differs from the default in /etc/krb5.conf.
# realm = EXAMPLE.COM
# Set this only if the default (currentuser/admin) will be incorrect.
# principal = example/admin@EXAMPLE.COM

[sasl]
# Set these only if your sasldb is only used by a particular application, and
# in a particular domain.  The default (all applications, all domains) is
# probably correct for most installations.
# appname = imap
# domain = EXAMPLE.COM

Back to top

/etc/logrotate.conf File

 -rw-r--r-- 1 root root 520  Feb 10 21:17 2011  Oct 26 08:08 2010  logrotate.conf
# see "man logrotate" for details
# rotate log files weekly
weekly

# keep 4 weeks worth of backlogs
rotate 4

# create new (empty) log files after rotating old ones
create

# uncomment this if you want your log files compressed
#compress

# RPM packages drop log rotation information into this directory
include /etc/logrotate.d

# no packages own wtmp -- we'll rotate them here
/var/log/wtmp {
    monthly
    minsize 1M
    create 0664 root utmp
    rotate 1
}

# system-specific logs may be also be configured here.

Back to top

/etc/mcelog.conf File

 -rwxr-xr-x 1 root root 2242  Feb 10 21:11 2011  Nov  9 19:45 2009  mcelog.conf
#
# Example config file for mcelog
# mcelog is the user space backend that decodes and process machine check events
# (cpu hardware errors) reported by the CPU to the kernel
#

# general format
# optionname = value
# white space is not allowed in value currently, except at the end where it is dropped
#

# in general all command line options that are not commands work here
# see man mcelog or mcelog --help for a list
# e.g. to enable the --no-syslog option use
# no-syslog = yes   (or no to disable)
# when the option has a argument
# logfile = /tmp/logfile

# Set CPU type for which mcelog decodes events:
# cpu = type
# valid values: k8, generic, p6old, xeon74xx, xeon75xx, nehalem, xeon71xx
# If this value is set incorrectly the decoded output will be likely incorrect.
# by default when this parameter is not set mcelog uses the CPU it is running on
# on very new kernels the mcelog events reported by the kernel also carry
# the CPU type which is used too when available and not overriden.

# Enable daemon mode:
# daemon = yes
# By default mcelog just processes the currently pending events and exits.
# in daemon mode it will keep running as a daemon in the background and poll
# the kernel for events and then decode them.

# Filter out known broken events by default
filter = yes

# output in undecoded raw format to be easier machine readable
# (default is decoded)
# raw = yes

# Set CPU Mhz to decode uptime from time stamp counter (output
# unreliable, not needed on new kernels which report the event time
# directly. A lot of systems don't have a linear time stamp clock
# and the output is wrong then.
# Normally mcelog tries to figure out if it the TSC is reliable
# and only uses the current frequency then.
# Setting a frequency forces timestamp decoding.
# cpumhz = 1800.00

# log output options
# Log decoded machine checks in syslog (default stdout or syslog for daemon)
# syslog = yes
# Log decoded machine checks in syslog with error level
# syslog-error = yes
# Never log anything to syslog
# no-syslog = yes
# Append log output to logfile instead of stdout. Only when no syslog logging is active
# logfile = filename

# Use SMBIOS information to decode DIMMs (needs root)
# dmi = yes
# dmi = no

Back to top

/etc/mke2fs.conf File

 -rw-r--r-- 1 root root 330  Feb 10 21:17 2011  Oct  5 15:57 2010  mke2fs.conf
[defaults]
	base_features = sparse_super,filetype,resize_inode,dir_index
	blocksize = 4096
	inode_ratio = 8192

[fs_types]
	small = {
		blocksize = 1024
		inode_ratio = 4096
	}
	floppy = {
		blocksize = 1024
	}
	news = {
		inode_ratio = 4096
	}
	largefile = {
		inode_ratio = 1048576
	}
	largefile4 = {
		inode_ratio = 4194304
	}

Back to top

/etc/modprobe.conf File

 -rw-r--r-- 1 root root 230  Feb 25 16:21 2011  Feb 25 16:21 2011  modprobe.conf
alias scsi_hostadapter cciss
alias scsi_hostadapter1 qla2xxx
alias eth5 e1000e
alias eth4 e1000e
alias eth3 e1000e
alias eth2 e1000e
alias eth1 bnx2
alias eth0 bnx2

alias bond0 bonding
options bond0 mode=1 miimon=100 max_bonds=2

Back to top

/etc/mtools.conf File

 -rw-r--r-- 1 root root 1983  Feb 10 21:11 2011  Aug  9 13:07 2006  mtools.conf
# Example mtools.conf files.  Uncomment the lines which correspond to
# your architecture and comment out the "SAMPLE FILE" line below

# Linux floppy drives
drive a: file="/dev/fd0" exclusive mformat_only
drive b: file="/dev/fd1" exclusive mformat_only

# First SCSI hard disk partition
#drive c: file="/dev/sda1"

# First IDE hard disk partition
#drive c: file="/dev/hda1"

# # dosemu floppy image
# drive m: file="/var/lib/dosemu/diskimage"

# dosemu hdimage
drive n: file="/var/lib/dosemu/hdimage" offset=8832

# # HPOJ (ptal-photod)
mtools_skip_check=1
drive p: file=":0" remote

# # Atari ramdisk image
# drive o: file="/tmp/atari_rd" offset=136

# # ZIP disk for Solaris:
# Drive X is ZIP-100 at target 5
# drive X: file="/dev/rdsk/c0t5d0s2" partition=4 scsi=1 nodelay

# # ZIP disk for SunOS:
# # Zip drive is at target 5, which default kernel calls tape st1 !!
# drive Y: file="/dev/rsd5c" partition=4 scsi=1 nodelay

# # autoselect zip drive/floppy on HP-UX 9/10
#    drive a: file="/dev/rdsk/c201d5"      exclusive partition=4
#    drive a: file="/dev/rdsk/c201d5s0"    exclusive partition=4
#    drive a: file="/dev/rfloppy/c201d0s0" exclusive

#          A/UX target 5 on 1st scsi bus   jaz or zip
# drive X: file="/dev/rdsk/c105d0s31"      partition=4


# Some examples for BeOS.
# floppy drive. hardcoded in devices.c, so no real need to define it here
#drive a: file="/dev/floppy_disk" exclusive
# ZIP drive on SCSI ID 6
#drive z: file="/dev/scsi_disk_060" offset=16384 fat_bits=16

# SCO Unix 3.2v4
# # Floppy disk drives
#
# drive a: file="/dev/install" exclusive
# drive b: file="/dev/install1" exclusive
#
# # SCSI hard disk partitions
#
# drive c: file="/dev/dsk/0sC"
# drive d: file="/dev/dsk/0sD"
# drive e: file="/dev/dsk/0sE"
# drive f: file="/dev/dsk/0sF"
# drive g: file="/dev/dsk/0sG"
# drive h: file="/dev/dsk/0sH"

# # uncomment the following line to display all file names in lower
# # case by default
# mtools_lower_case=1

Back to top

/etc/multipath.conf File

 -rw-r--r-- 1 root root 1144  Feb 25 20:48 2011  Feb 25 20:48 2011  multipath.conf
defaults {
        udev_dir                /dev
        polling_interval        10
        selector                "round-robin 0"
        path_grouping_policy    multibus
        getuid_callout          "/sbin/scsi_id -g -u -s /block/%n"
        prio_callout            /bin/true
        rr_min_io               100
        rr_weight               priorities
        failback                immediate
        user_friendly_names     yes
}

blacklist {
        devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
        devnode "^(cciss!c[0-9]*d[0-9]*p[0-9]*|cciss!c[0-9]d[0-9]*)"
}


multipaths {
        multipath {
                wwid                    350002ac004750a4c
                alias                   quorum
        }
        multipath {
                wwid                    350002ac003f10a4c
                alias                   3PARd0
        }
}

devices {
        device {
                vendor                  "3PARdata"
                product                 "VV"
                path_grouping_policy    multibus
                path_checker            tur
                no_path_retry           60
        }
}

Back to top

/etc/nscd.conf File

 -rw-r--r-- 1 root root 1895  Apr 29 06:47 2011  Apr 11 14:23 2011  nscd.conf
#
# /etc/nscd.conf
#
# An example Name Service Cache config file.  This file is needed by nscd.
#
# Legal entries are:
#
#	logfile			<file>
#	debug-level		<level>
#	threads			<initial #threads to use>
#	max-threads		<maximum #threads to use>
#	server-user             <user to run server as instead of root>
#		server-user is ignored if nscd is started with -S parameters
#       stat-user               <user who is allowed to request statistics>
#	reload-count		unlimited|<number>
#	paranoia		<yes|no>
#	restart-interval	<time in seconds>
#
#       enable-cache		<service> <yes|no>
#	positive-time-to-live	<service> <time in seconds>
#	negative-time-to-live   <service> <time in seconds>
#       suggested-size		<service> <prime number>
#	check-files		<service> <yes|no>
#	persistent		<service> <yes|no>
#	shared			<service> <yes|no>
#	max-db-size		<service> <number bytes>
#	auto-propagate		<service> <yes|no>
#
# Currently supported cache names (services): passwd, group, hosts
#


#	logfile			/var/log/nscd.log
#	threads			6
#	max-threads		128
	server-user		nscd
#	stat-user		nocpulse
	debug-level		0
#	reload-count		5
	paranoia		no
#	restart-interval	3600

	enable-cache		passwd		yes
	positive-time-to-live	passwd		600
	negative-time-to-live	passwd		20
	suggested-size		passwd		211
	check-files		passwd		yes
	persistent		passwd		yes
	shared			passwd		yes
	max-db-size		passwd		33554432
	auto-propagate		passwd		yes

	enable-cache		group		yes
	positive-time-to-live	group		3600
	negative-time-to-live	group		60
	suggested-size		group		211
	check-files		group		yes
	persistent		group		yes
	shared			group		yes
	max-db-size		group		33554432
	auto-propagate		group		yes

	enable-cache		hosts		yes
	positive-time-to-live	hosts		3600
	negative-time-to-live	hosts		20
	suggested-size		hosts		211
	check-files		hosts		yes
	persistent		hosts		yes
	shared			hosts		yes
	max-db-size		hosts		33554432

Back to top

/etc/nsswitch.conf File

 -rw-r--r-- 1 root root 1696  Apr 29 06:48 2011  Sep 23 01:17 2004  nsswitch.conf
#
# /etc/nsswitch.conf
#
# An example Name Service Switch config file. This file should be
# sorted with the most-used services at the beginning.
#
# The entry '[NOTFOUND=return]' means that the search for an
# entry should stop if the search in the previous entry turned
# up nothing. Note that if the search failed due to some other reason
# (like no NIS server responding) then the search continues with the
# next entry.
#
# Legal entries are:
#
#	nisplus or nis+		Use NIS+ (NIS version 3)
#	nis or yp		Use NIS (NIS version 2), also called YP
#	dns			Use DNS (Domain Name Service)
#	files			Use the local files
#	db			Use the local database (.db) files
#	compat			Use NIS on compat mode
#	hesiod			Use Hesiod for user lookups
#	[NOTFOUND=return]	Stop searching if not found so far
#

# To use db, put the "db" in front of "files" for entries you want to be
# looked up first in the databases
#
# Example:
#passwd:    db files nisplus nis
#shadow:    db files nisplus nis
#group:     db files nisplus nis

passwd:     files
shadow:     files
group:      files

#hosts:     db files nisplus nis dns
hosts:      files dns

# Example - obey only what nisplus tells us...
#services:   nisplus [NOTFOUND=return] files
#networks:   nisplus [NOTFOUND=return] files
#protocols:  nisplus [NOTFOUND=return] files
#rpc:        nisplus [NOTFOUND=return] files
#ethers:     nisplus [NOTFOUND=return] files
#netmasks:   nisplus [NOTFOUND=return] files

bootparams: nisplus [NOTFOUND=return] files

ethers:     files
netmasks:   files
networks:   files
protocols:  files
rpc:        files
services:   files

netgroup:   nisplus

publickey:  nisplus

automount:  files nisplus
aliases:    files nisplus

Back to top

/etc/ntp.conf File

 -rw-r--r-- 1 root root 2013  Feb 10 22:06 2011  Feb 10 22:06 2011  ntp.conf
# Permit time synchronization with our time source, but do not
# permit the source to query or modify the service on this system.
restrict default kod nomodify notrap nopeer noquery
restrict -6 default kod nomodify notrap nopeer noquery

# Permit all access over the loopback interface.  This could
# be tightened as well, but to do so would effect some of
# the administrative functions.
restrict 127.0.0.1
restrict -6 ::1

# Hosts on local network are less restricted.
#restrict 192.168.1.0 mask 255.255.255.0 nomodify notrap

# Use public servers from the pool.ntp.org project.
# Please consider joining the pool (http://www.pool.ntp.org/join.html).
# server 0.rhel.pool.ntp.org
# server 1.rhel.pool.ntp.org
# server 2.rhel.pool.ntp.org

#broadcast 192.168.1.255 key 42		# broadcast server
#broadcastclient			# broadcast client
#broadcast 224.0.1.1 key 42		# multicast server
#multicastclient 224.0.1.1		# multicast client
#manycastserver 239.255.254.254		# manycast server
#manycastclient 239.255.254.254 key 42	# manycast client

# Undisciplined Local Clock. This is a fake driver intended for backup
# and when no outside source of synchronized time is available.
# server	127.127.1.0	# local clock
# # fudge	127.127.1.0 stratum 10

# Drift file.  Put this in a directory which the daemon can write to.
# No symbolic links allowed, either, since the daemon updates the file
# by creating a temporary in the same directory and then rename()'ing
# it to the file.
driftfile /var/lib/ntp/drift

# Key file containing the keys and key identifiers used when operating
# with symmetric key cryptography.
keys /etc/ntp/keys

# Specify the key identifiers which are trusted.
#trustedkey 4 8 42

# Specify the key identifier to use with the ntpdc utility.
#requestkey 8

# Specify the key identifier to use with the ntpq utility.
#controlkey 8
# server time.datapipe.net
# server ntp.ewr.datapipe.net
# server ntp.sjc.datapipe.net
server time.datapipe.net
server ntp.ewr.datapipe.net
server ntp.sjc.datapipe.net

Back to top

/etc/oddjobd.conf File

 -rw-r--r-- 1 root root 4461  Feb 17 21:03 2011  Jul 19 20:08 2006  oddjobd.conf
<?xml version="1.0"?>

<!-- This configuration file controls the oddjob daemon.  It controls
     which requests the daemon will recognize, and whether or not it
     will attempt to fulfill them on the behalf of particular users.

     Create and edit oddjobd-local.conf rather than changing this file
     directly.

     Each <oddjobconfig> contains a mixture of <service> and <include> nodes.

     Each <service> element corresponds to a well-known D-Bus address (given
     in the "name" attribute) which the oddjobd daemon will answer to.  It
     may contain one or more <object> elements which each describe an object
     path.  Each <object>, in turn, is named by its "name" attribute.

     Each <object> element must also contain zero or more <interface>
     elements, which are named by their "name" attributes and correspond to
     names of interfaces which the object implements.

     Each <interface> element must contain zero or more <method>
     elements, which are named by their "name" attributes.  Each
     <method> node corresponds to a D-Bus method implemented by the
     object as part of the interface.

     Each method must include an access-control list which contains at
     least one rule, or the daemon will ignore any attempts to call the
     method.

     When checking if a client is allowed to use a method, all deny
     rules are processed, then all allow rules.  The first rule which
     matches the user decides whether access is allowed or denied.

     Access rules can specify either a user (using the "user"
     attribute), or a range of UIDs (using the "min_uid" and "max_uid"
     attributes).

     If SELinux support was compiled in, then a rule can also specify
     whether or not it applies if the SELinux policy is being enforced
     ("selinux_enforcing"), or what the caller's SELinux context
     ("selinux_context"), user ("selinux_user"), role ("selinux_role"),
     or type ("selinux_type") must be for that rule to apply.

     A method may, as part of its definition, specify an external
     program which is to be run when the method is invoked, by including
     a <helper> node.  The <helper> node should include an "exec"
     attribute naming the external program which will be launched to
     accomplish the given task.  Depending on the value of its
     "argument_passing_method" attribute, it will receive its arguments
     either over stdin, one argument per line, or on the command line.
     Depending on the value of the "prepend_user_name" attribute, the
     argument list may or may not begin with the calling user's name.
     The helper will be run with superuser privileges.

     Here's what an example oddjobd-local.conf might look like:

     <service name="com.redhat.oddjob">
       <object name="/com/redhat/oddjob">
         <interface name="com.redhat.oddjob">
           <method name="mkhomedirfor">
             <allow user="root"/>
             <allow selinux_enforcing="yes" selinux_role="staff_r"/>
             <allow user="dovecot"/>
           </method>
         </interface>
       </object>

       <object name="/com/redhat/oddjob">
         <interface name="com.redhat.oddjob">
           <method name="mkmyhomedir">
             <helper exec="/usr/bin/pwd" arguments="0" prepend_user_name="no"/>
             <allow min_uid="500"/>
           </method>
         </interface>
       </object>
     </service>
  -->

<oddjobconfig>

  <service name="com.redhat.oddjob">
    <object name="/com/redhat/oddjob">
      <interface name="com.redhat.oddjob">

        <method name="list">
          <allow min_uid="0" max_uid="0"/>
        </method>

        <method name="quit">
          <allow user="root"/>
        </method>

        <method name="reload">
          <allow user="root"/>
        </method>

        <method name="reboot">
          <helper exec="/sbin/reboot" arguments="0"/>
        </method>

        <method name="mkmyhomedir">
          <helper exec="/usr/libexec/oddjob/mkhomedir" arguments="0" prepend_user_name="yes"/>
          <allow user="root"/>
        </method>

        <method name="mkhomedirfor">
          <helper exec="/usr/libexec/oddjob/mkhomedir" arguments="1"/>
          <allow user="root"/>
        </method>

      </interface>

    </object>

  </service>

  <include ignore_missing="yes">/etc/oddjobd.conf.d/*.conf</include>
  <include ignore_missing="yes">/etc/oddjobd-local.conf</include>

</oddjobconfig>

Back to top

/etc/pam_smb.conf File

 -rw-r--r-- 1 root root 12  Feb 10 21:11 2011  Jul 12 20:07 2006  pam_smb.conf
WORKGROUP


Back to top

/etc/prelink.conf File

 -rw-r--r-- 1 root root 973  Feb 10 21:11 2011  Sep 18 15:27 2008  prelink.conf
# This config file contains a list of directories both with binaries
# and libraries prelink should consider by default.
# If a directory name is prefixed with `-l ', the directory hierarchy
# will be walked as long as filesystem boundaries are not crossed.
# If a directory name is prefixed with `-h ', symbolic links in a
# directory hierarchy are followed.
# Directories or files with `-b ' prefix will be blacklisted.
# `-c ' is used to source additional config file snippets.
-c /etc/prelink.conf.d/*.conf
-b *.la
-b *.png
-b *.py
-b *.pl
-b *.pm
-b *.sh
-b *.xml
-b *.xslt
-b *.a
-b *.js
-b /lib/modules
-b /usr/lib/locale
-b /usr/X11R6/lib{,64}/X11/xfig
-b /usr/lib{,64}/libfreebl3.so
-b /usr/lib{,64}/libsoftokn3.so
-l /bin
-l /usr/bin
-l /sbin
-l /usr/sbin
-l /usr/X11R6/bin
-l /usr/kerberos/bin
-l /usr/games
-l /usr/libexec
-l /var/ftp/bin
-l /lib{,64}
-l /usr/lib{,64}
-l /usr/X11R6/lib{,64}
-l /usr/kerberos/lib{,64}
-l /usr/X11R6/LessTif
-l /var/ftp/lib{,64}

Back to top

/etc/reader.conf File

 -rw-r--r-- 1 root root 435  Feb 10 22:03 2011  Feb 10 22:03 2011  reader.conf
# Configuration file for pcsc-lite
#
# Don't modify this file. Instead put a file or modify the files in
# /etc/reader.conf.d/ and run /usr/sbin/update-reader.conf
# afterwards.  Note that when starting pcscd with the init script,
# update-reader.conf will be run automatically.
#
# Note also that this file should include configuration for serial and PCMCIA
# readers only; USB readers should _not_ be configured here.

# End of file

Back to top

/etc/resolv.conf File

 -rw-r--r-- 1 root root 72  Feb 10 21:13 2011  Feb 10 21:13 2011  resolv.conf
search smq.datapipe.net
nameserver 64.27.65.17
nameserver 64.27.120.188

Back to top

/etc/sensors.conf File

 -rw-r--r-- 1 root root 85179  Feb 10 21:13 2011  Jan 26 11:13 2010  sensors.conf
# Sensors configuration file used by 'libsensors'
#------------------------------------------------
#
##########################################################################
#                                                                        #
#    PLEASE READ THIS HELPFUL HINT!!!                                    #
#                                                                        #
#       The 'set' lines (generally for min and max values)               #
#       do not take effect until you run 'sensors -s' as root !!!        #
#       We suggest you put 'sensors -s' in a /etc/rc.d/... file          #
#       to be run at boot time after the modules are inserted !!!        #
#                                                                        #
##########################################################################
#
#
# OVERVIEW
# --------
# This configuration file will be used by all userspace applications
# linked to libsensors. It is NOT used by the lm_sensors drivers directly.
#
# This config file consists of two parts: the heavily commented LM78
# example, and the real parts. Search for '####' if you want to skip
# to the real stuff.
#
# Hash marks introduce comments, which continue until the end of a line.
#
# Identifiers consisting of only digits and letters can be used
# unquoted; other identifiers must be quoted. Escape characters within
# quotes operate like those in C.
#
#
# CHIP LINES
# ----------
# A 'chip' line specifies what the following 'label', 'compute', 'set' and
# 'ignore' lines refer to. In this case, until the
# next 'chip' line, everything refers to all lm78, lm78-j and lm79
# chips. Other examples are *-isa-* for everything on the ISA bus, and
# lm78-j-i2c-*-4e for all lm78-j chips on address 0x4e of any I2C bus.
#
# If more chip statements match a specific chip, they are all considered.
# Later lines overrule earlier lines, so if you set the in0 label for
# lm78-* to "This", and later on the in0 label for lm78-isa-* to "That",
# "That" is used for LM78 chips on the ISA bus, and "This" for LM78
# chips on a non-ISA bus.
#
#	chip "lm78-*" "lm78-j-*" "lm79-*"
#
#
# FEATURE NAMES
# -------------
# Feature names are used in 'label', 'compute', 'set', and 'ignore' lines.
# Example feature names are 'in0', 'temp2', 'in3_min', and 'temp3_over'.
# These features are defined for each chip in lib/chips.c.
#
# Undefined features will be silently ignored in 'label' and 'compute' lines.
# Undefined features in 'set' lines will result in 'Unknown feature name'
# when running 'sensors -s'.
#
# Unfortunately, feature names starting with a number must be in
# double quotes or you get "parse error, expecting 'NAME'".
#
# If you have trouble, verify the features in lib/chips.c!!!
#
#
# LABEL LINES
# -----------
# A label line describes what a certain feature stands for on your
# mainboard. Programs can retrieve these names and display them.
# If no label is specified for a certain feature, the default name
# (ie. 'fan1' for fan1) is used.
#
# If you specify a label for in1, this label is also used for in1_min and
# in1_max, unless they have their own labels declared. There are several
# of these logical groups.
#
# These are as advised in the LM78 and LM79 data sheets, and used on most
# boards we have seen.
#
#  	label in0 "VCore 1"
#  	label in1 "VCore 2"
#  	label in2 "+3.3V"
#  	label in3 "+5V"
#  	label in4 "+12V"
#  	label in5 "-12V"
#  	label in6 "-5V"
#
#
# COMPUTE LINES
# -------------
# A compute line describes how to scale a certain feature. There are
# two expressions in it: the first describes how the /proc value must
# be translated to a user value, the second how a user value must be
# translated to a /proc value. '@' is the value to operate on. You may
# refer to other readable features (like '2 * vid').
#
# The following operators are valid: + - * / ( ) ^ `
# ^ is e**x and ` is ln(x) (valid in library version 2.0.0 /
# lm_sensors 2.8.0 or higher)
#
# Like for the label statement, there are logical groups here. They are
# sometimes a bit different, though. For example, fan1_div is in the
# logical label group of fan1 (it gets the same label if none is declared
# for it), but it is not in the compute group of fan1 (as it uses a
# completely different system of values).
#
#
# VOLTAGE COMPUTATION DETAILS
# ---------------------------
# Most voltage sensors in sensor chips have a range of 0 to 4.096 Volts.
# This is generally sufficient for the 3.3 and CPU (2.5V, for example)
# supply voltages, so the sensor chip reading is the actual voltage.
#
# Other supply voltages must be scaled with an external resistor network.
# The chip driver generally reports the 'raw' value 0 - 4.09 V, and the
# userspace application must convert this raw value to an actual voltage.
# The 'compute' lines provide this facility.
#
# Unfortunately the resistor values vary among motherboard types.
# Therefore you may have to adjust the computations in this file
# to match your motherboard.
#
# For positive voltages (in3, in4), two resistors are used, with the following
# formula (R1,R2: resistor values, Vs: read voltage, Vin: pin voltage)
#	R1 = R2 * (Vs/Vin - 1)
# For negative voltages (in5, in6) two resistors are used, with the following
# formula (Rin,Rf: resistor values, Vs: read voltage, Vin: pin voltage)
#	Rin = (Vs * Rf) / Vin
#
# Note: Some chips use a different formula, see it87 section for example.
#
# Here are the official LM78 and LM79 data sheet values.
# 	      Vs     R1,Rin   R2,Rf    Vin
# 	in3   +5.0      6.8    10     +2.98
# 	in4  +12.0     30      10     +3.00
# 	in5  -12.0    240      60     +3.00
# 	in6   -5.0    100      60     +3.00
#
# These would lead to these declarations:
# 	compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
# 	compute in4 ((30/10)+1)*@  ,  @/((30/10)+1)
# 	compute in5 -(240/60)*@    ,  -@/(240/60)
# 	compute in6 -(100/60)*@    ,  -@/(100/60)
#
# On almost any mainboard we have seen, the Winbond compute values lead to
# much better results, though.
#
# 	      Vs     R1,Rin   R2,Rf    Vin
# 	in4  +12.0     28      10     +3.15
# 	in5  -12.0    210      60.4   +3.45
# 	in6   -5.0     90.9    60.4   +3.33
#
# These leads to these declarations:
#  	compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
#  	compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
#  	compute in5 -(210/60.4)*@  ,  -@/(210/60.4)
#  	compute in6 -(90.9/60.4)*@ ,  -@/(90.9/60.4)
#
# NOTE: On many motherboards, the -5V and -12V sensors are not connected.
# Add ignore lines so these readings will not be displayed. For example:
#	ignore in5
#	ignore in6
#
#
# TEMPERATURE COMPUTATION EXAMPLES
# --------------------------------
# There are two common ways to adjust temperature readings.
# One is to adjust by a constant. The other is to change the
# temperature sensor type.
#
# Add 5 degrees to temperature sensor 1:
#	compute temp1 @+5,@-5
#
# Sensor type adjustments (certain chips only):
# ...Set temp1 to processor's thermal diode:
#	set sensor1 1 (Winbond chips)
#	set sensor1 3 (IT87xx and MTP008 chips)
#
# ...Set temp1 sensor to 3904 transistor:
#	set sensor1 2 (Winbond chips)
#
# ...Set temp1 to thermistor:
#	set sensor1 3435 (Winbond chips)
#	set sensor1 2 (IT87xx and MTP008 chips)
#
# Often, a temperature sensor is disconnected; disable it with an ignore line:
#	ignore temp3
#
#
# SET LINES
# ---------
# Set statements set things like limits. Complete expressions can be
# used. Not everything can sensibly be set: setting 'in0', for example,
# is impossible! These settings are put through the compute translations;
# so if we specify '12.8' for in6, '3.2' will actually be written!
#
# Important note: In the 'sensors' program, these only take effect
# after running 'sensors -s'!!!
#
# Here are some examples:
#
#	set in0_max vid*1.05
#	set in0_min vid*0.95
#	set temp1_over 40
#	set temp1_hyst 37
#
# Think of tempx_over as 'alarm set' and tempx_hyst as 'alarm clear'
# thresholds. In most cases the 'over' value should be higher than
# the 'hyst' value by several degrees.
#
# All the set statements from this file are commented out by default.
# The reason is that the proper limits are highly system-dependent,
# and writing improper limits may have all sorts of weird effects,
# from beeping to CPU throttling to instant reboot. If you want to
# actually set the limits, remove the comment marks.
#
#
# IGNORE LINES
# ------------
# Ignore statements tell certain features are not wanted. User programs can
# still read them if they really want, though; this is just an advisory
# marking. 'in0' would also invalidate 'in0_max' and 'in0_min'.
# 'ignore' does not disable anything in the actual sensor chip; it
# simply advises the user program to not access that data.
#
#	ignore in0
#
#
# STATEMENT ORDER
# ---------------
# Statements can go in any order, EXCEPT that some statements depend
# on others. Dependencies could be either in the library or the driver.
# A 'compute' statement must go before a 'set' statement
# for the same feature or else the 'set' won't be computed correctly.
# This is a library dependency.
# A 'set fan1_div' statement must go before a 'set fan1_min' statement,
# because the driver uses the divisor in calculating the minimum.
# Also, one should set vrm prior to using vid in any formula.
#
#
# BUS LINES
# ---------
# There is one other feature: the 'bus' statement. An example is below.
#
#	bus "i2c-0" "SMBus PIIX4 adapter at e800" "Non-I2C SMBus adapter"
#
# If we refer from now on to 'i2c-0' in 'chip' lines, this will run-time
# be matched to this bus. So even if the PIIX4 is called 'i2c-5' at that
# moment, because five other adapters were detected first, 'i2c-0' in
# the config file would always only match this physical bus. In the above
# config file, this feature is not needed; but the next lines would
# only affect the LM75 chips on the PIIX4 adapter:
#
#	chip "lm75-i2c-0-*"
#
# You should really use the output of /proc/bus/chips to generate bus lines,
# because one mistyped characted will inhibit the match. Wildcards are not
# yet supported; spaces at the end are ignored, though.
#
#
# BEEPS
# -----
# Some chips support alarms with beep warnings. When an alarm is triggered
# you can be warned by a beeping signal through your computer speaker. It
# is possible to enable beeps for all alarms on a chip using the following
# line:
#
# 	set beep_enable 1
#
# or disable them using:
#
# 	set beep_enable 0
#
#
##########################################################################
#### Here begins the real configuration file


chip "lm78-*" "lm78-j-*" "lm79-*" "w83781d-*"

# These are as advised in the LM78 and LM79 data sheets, and used on almost
# any mainboard we have seen.

    label in0 "VCore 1"
    label in1 "VCore 2"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"

# For positive voltages (in3, in4), two resistors are used, with the following
# formula (R1,R2: resistor values, Vs: read voltage, Vin: pin voltage)
#   R1 = R2 * (Vs/Vin - 1)
# For negative voltages (in5, in6) two resistors are used, with the following
# formula (Rin,Rf: resistor values, Vs: read voltage, Vin: pin voltage)
#   Rin = (Vs * Rf) / Vin
#
# Here are the official LM78 and LM79 data sheet values.
#       Vs     R1,Rin   R2,Rf    Vin
# in3   +5.0      6.8    10     +2.98
# in4  +12.0     30      10     +3.00
# in5  -12.0    240      60     +3.00
# in6   -5.0    100      60     +3.00
#
# These would lead to these declarations:
# compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
# compute in4 ((30/10)+1)*@  ,  @/((30/10)+1)
# compute in5 -(240/60)*@    ,  -@/(240/60)
# compute in6 -(100/60)*@    ,  -@/(100/60)
#
# On almost any mainboard we have seen, the Winbond compute values lead to
# much better results, though.
#
#       Vs     R1,Rin   R2,Rf    Vin
# in4  +12.0     28      10     +3.15
# in5  -12.0    210      60.4   +3.45
# in6   -5.0     90.9    60.4   +3.33
#
# These leads to these declarations:

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
    compute in5 -(210/60.4)*@  ,  -@/(210/60.4)
    compute in6 -(90.9/60.4)*@ ,  -@/(90.9/60.4)

# Here, we assume the VID readings are valid, and we use a max. 5% deviation

#    set in0_min vid*0.95
#    set in0_max vid*1.05
#    set in1_min vid*0.95
#    set in1_max vid*1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
#    set in4_min 12 * 0.95
#    set in4_max 12 * 1.05
#    set in5_max -12 * 0.95
#    set in5_min -12 * 1.05
#    set in6_max -5 * 0.95
#    set in6_min -5 * 1.05

# Examples for lm78, lm78j, lm79 temperature limits
#    set temp_over 40
#    set temp_hyst 37

# Examples for w83781d temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47
#    set temp3_over 52
#    set temp3_hyst 47

# Examples of fan low speed limits
#    set fan1_min 3000
#    set fan2_min 3000
#    set fan3_min 3000

# Ignore fans you don't actually have
#    ignore fan1
#    ignore fan2
#    ignore fan3

# In case a lm78 is used together with a lm75, the lm78 temp sensor will
# generally show the M/B temperature while the lm75 temp sensor will show
# the CPU temperature.
#    label temp "M/B Temp"

# Uncomment the following line to enable beeps for all alarms on this chip
#    set beep_enable 1



chip "lm75-*"

# Most boards don't need scaling. Following is for the Asus TX97-E.
#   compute temp @*2.0, @/2.0

# Examples for temperature limits
#    set temp_over 70
#    set temp_hyst 65

# In case a lm75 is used together with a lm78, the lm78 temp sensor will
# generally show the M/B temperature while the lm75 temp sensor will show
# the CPU temperature.
#    label temp "CPU Temp"


chip "sis5595-*"

    label in0 "VCore 1"
    label in1 "VCore 2"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)

#    set in0_min 2.0 * 0.95
#    set in0_max 2.0 * 1.05
#    set in1_min 2.0 * 0.95
#    set in1_max 2.0 * 1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
#    set in4_min 12 * 0.95
#    set in4_max 12 * 1.05

#
# SiS5595 temperature calculation
# The driver currently includes a calculation due to the wide
# variation in thermistor types on SiS5595 motherboards.
# The driver currently has a calculation of t = (.83x + 52.12).
# One user reports the correct formula of t = (.345x - 12).
# So you want to put a compute line in sensors.conf that has
# the inverse of the driver formula, and put your formula on top of it.
# The inverse of the driver formula is x = (1.20t - 62.77)
# So the final formula is newt = (.345(1.20t - 62.77)) - 12).
# Put this in the sensors.conf file as
# compute temp ((.345 * ((1.20 * @) - 62.77)) - 12), ...
# where ... is the inverse function I leave to you.
#
# Look in your 'Vendor.ini' file to see which one is present
# on your motherboard. Look for the line like:
#	[Temp1]
#	     ThermistorType     = NTC-10KC15-1608-1P
# Fix up a 'compute' line to match your thermistor type.
# Warning. You still don't have enough information to do this.
#	     ThermistorType     = NTC-10KC15-1608-1P (10K at 25C; Beta = 3435)
#   compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
#	     ThermistorType     = NTC-103KC15-1608-1P  (??)
#   compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
#	     ThermistorType     = NTC-103AT-2 (10K at 25C; Beta = 3435)
#   compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
#	     ThermistorType     = NTC-103JT   (10K at 25C; Beta = 3435)
#   compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...

# examples for sis5595 temperature limits;
# for sis5595, temp_hyst is really the low limit, not a hysteresis value
#    set temp_over 40
#    set temp_hyst 37


chip "w83782d-*" "w83627hf-*"

# Same as above for w83781d except that in5 and in6 are computed differently.
# Rather than an internal inverting op amp, the 82d/83s use standard positive
# inputs and the negative voltages are level shifted by a 3.6V reference.
# The math is convoluted, so we hope that your motherboard
# uses the recommended resistor values.

    label in0 "VCore 1"
    label in1 "VCore 2"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"
    label in7 "V5SB"
    label in8 "VBat"

# Abit BP6 motherboard has a few differences. VCore1 and VCore2 are the core
# voltages of the two processors. Vtt is memory bus termination resistors
# voltage.
#    label in1 "Vtt"
#    label in8 "VCore2"

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
    compute in5 (5.14 * @) - 14.91  ,  (@ + 14.91) / 5.14
    compute in6 (3.14 * @) -  7.71  ,  (@ +  7.71) / 3.14
    compute in7 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)

# adjust this if your vid is wrong; see doc/vid
#   set vrm 9.0

# set limits to  5% for the critical voltages
# set limits to 10% for the non-critical voltages
# set limits to 20% for the battery voltage

#    set in0_min vid*0.95
#    set in0_max vid*1.05
#    set in1_min vid*0.95
#    set in1_max vid*1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
#    set in4_min 12 * 0.90
#    set in4_max 12 * 1.10
#    set in5_max -12 * 0.90
#    set in5_min -12 * 1.10
#    set in6_max -5 * 0.95
#    set in6_min -5 * 1.05
#    set in7_min 5 * 0.95
#    set in7_max 5 * 1.05
#    set in8_min 3.0 * 0.80
#    set in8_max 3.0 * 1.20

# set up sensor types (thermistor is default)
# 1 = PII/Celeron Diode; 2 = 3904 transistor;
# 3435 = thermistor with Beta = 3435
# If temperature changes very little, try 1 or 2.
#   set sensor1 1
#   set sensor2 2
#   set sensor3 3435

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47
#    set temp3_over 52
#    set temp3_hyst 47


chip "w83783s-*"

# Same as above for w83781d except that in5 and in6 are computed differently.
# Rather than an internal inverting op amp, the 82d/83s use standard positive
# inputs and the negative voltages are level shifted by a 3.6V reference.
# The math is convoluted, so we hope that your motherboard
# uses the recommended resistor values.

    label in0 "VCore 1"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
    compute in5 (5.14 * @) - 14.91  ,  (@ + 14.91) / 5.14
    compute in6 (3.14 * @) -  7.71  ,  (@ +  7.71) / 3.14

# adjust this if your vid is wrong; see doc/vid
#   set vrm 9.0

# set limits to  5% for the critical voltages
# set limits to 10% for the non-critical voltages
# set limits to 20% for the battery voltage

#   set in0_min vid*0.95
#   set in0_max vid*1.05
#   set in2_min 3.3 * 0.95
#   set in2_max 3.3 * 1.05
#   set in3_min 5.0 * 0.95
#   set in3_max 5.0 * 1.05
#   set in4_min 12 * 0.90
#   set in4_max 12 * 1.10
#   set in5_max -12 * 0.90
#   set in5_min -12 * 1.10
#   set in6_max -5 * 0.95
#   set in6_min -5 * 1.05

# set up sensor types (thermistor is default)
# 1 = PII/Celeron Diode; 2 = 3904 transistor;
# 3435 = thermistor with Beta = 3435
# If temperature changes very little, try 1 or 2.
#   set sensor1 1
#   set sensor2 2

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47


chip "w83697hf-*"

# Same as above for w83781d except that in5 and in6 are computed differently.
# Rather than an internal inverting op amp, the 82d/83s use standard positive
# inputs and the negative voltages are level shifted by a 3.6V reference.
# The math is convoluted, so we hope that your motherboard
# uses the recommended resistor values.

# no in1 on this chip.

    label in0 "VCore"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"
    label in7 "V5SB"
    label in8 "VBat"

# Tyan Trinity S2495 KT400 has a few differences. Thanks to Eric Schumann
# for proving this information. Same is true for Epox 8K3A and 8KHA+.
# Thanks to Thomas Schorpp for additional feedback.
#    label in2 "VAgp"
#    label in5 "+3.3V" # aka. Vio
#    label in6 "Vdimm"
#    label in7 "VBat"
#    label in8 "V5SB"
#
# You'll also want to comment out the in5 and in6 compute lines right below,
# and rename compute in7 to compute in8.

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
    compute in5 (5.14 * @) - 14.91  ,  (@ + 14.91) / 5.14
    compute in6 (3.14 * @) -  7.71  ,  (@ +  7.71) / 3.14
    compute in7 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)

# 697HF does not have VID inputs so you MUST set your core
# voltage limits below. Currently set for 1.8V core.
#               vvv

#   set in0_min 1.8 * 0.95
#   set in0_max 1.8 * 1.05

#   set in2_min 3.3 * 0.95
#   set in2_max 3.3 * 1.05
#   set in3_min 5.0 * 0.95
#   set in3_max 5.0 * 1.05
#   set in4_min 12 * 0.90
#   set in4_max 12 * 1.10
#   set in5_max -12 * 0.90
#   set in5_min -12 * 1.10
#   set in6_max -5 * 0.95
#   set in6_min -5 * 1.05
#   set in7_min 5 * 0.95
#   set in7_max 5 * 1.05
#   set in8_min 3.0 * 0.80
#   set in8_max 3.0 * 1.20

# And for Tyan Trinity S2495 KT400 and Epox 8K3A and 8KHA+:
#    set in2_min 1.5 * 0.95
#    set in2_max 1.5 * 1.05
#    set in5_min 3.3 * 0.95
#    set in5_max 3.3 * 1.05
#    set in6_min 2.5 * 0.95 # 2.6 on Epox
#    set in6_max 2.5 * 1.05 # 2.6 on Epox
#    set in7_min 3.0 * 0.90
#    set in7_max 3.0 * 1.10
#    set in8_min 5 * 0.90
#    set in8_max 5 * 1.10

# set up sensor types (thermistor is default)
# 1 = PII/Celeron Diode; 2 = 3904 transistor;
# 3435 = thermistor with Beta = 3435
# If temperature changes very little, try 1 or 2.
#   set sensor1 1
#   set sensor2 2
#   set sensor3 3435

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47


chip "w83627thf-*" "w83637hf-*"

# Rather than an internal inverting op amp, the 627thf uses standard positive
# inputs and the negative voltages are level shifted by a 3.6V reference
# (same as 82d/83s).
# The math is convoluted, so we hope that your motherboard
# uses the recommended resistor values.
# Note that in1 (+12V) is the usual in4, and in4 (-12V) is the usual in5.
# Data sheet is obviously wrong for in4, the usual formula should work.
# No in5 nor in6.
# sensors doesn't need the ignore lines but sensord does...
    ignore in5
    ignore in6

    label in0 "VCore"
    label in1 "+12V"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "-12V"
    label in7 "V5SB"
    label in8 "VBat"

# Mori Hiroyuki reported to need this (P4P800)
#   compute in0 @/2, @*2

    compute in1 ((28/10)+1)*@, @/((28/10)+1)
    compute in3 ((34/51)+1)*@, @/((34/51)+1)
    compute in4 (5.14*@)-14.91, (@+14.91)/5.14
    compute in7 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)

# adjust this if your vid is wrong; see doc/vid
#   set vrm 9.0

# set limits to  5% for the critical voltages
# set limits to 10% for the non-critical voltages
# set limits to 20% for the battery voltage
# if your vid is wrong, you'll need to adjust in0_min and in0_max

#   set in0_min vid * 0.95
#   set in0_max vid * 1.05
#   set in1_min 12 * 0.90
#   set in1_max 12 * 1.10
#   set in2_min 3.3 * 0.95
#   set in2_max 3.3 * 1.05
#   set in3_min 5.0 * 0.95
#   set in3_max 5.0 * 1.05
#   set in4_min -12 * 1.10
#   set in4_max -12 * 0.90
#   set in7_min 5 * 0.95
#   set in7_max 5 * 1.05
#   set in8_min 3.0 * 0.80
#   set in8_max 3.0 * 1.20

# set up sensor types (thermistor is default)
# 1 = PII/Celeron Diode; 2 = 3904 transistor;
# 3435 = thermistor with Beta = 3435
# If temperature changes very little, try 1 or 2.
#   set sensor1 1
#   set sensor2 2
#   set sensor3 3435

    label temp1 "M/B Temp"
    label temp2 "CPU Temp"
#   ignore temp3

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47
#    set temp3_over 52
#    set temp3_hyst 47

#   ignore fan1
    label fan2 "CPU Fan"
#   ignore fan3


# Here are configurations for Winbond W83792AD/D chip.
chip "w83792d-*"

    label in0 "VCoreA"
    label in1 "VCoreB"
    label in2 "VIN0"
    label in3 "VIN1"
    label in4 "VIN2"
    label in5 "VIN3"
    label in6 "5VCC"
    label in7 "5VSB"
    label in8 "VBAT"
    label fan1 "Fan1"
    label fan2 "Fan2"
    label fan3 "Fan3"
    label fan4 "Fan4"
    label fan5 "Fan5"
    label fan6 "Fan6"
    label fan7 "Fan7"
    label temp1 "Temp1"
    label temp2 "Temp2"
    label temp3 "Temp3"

#    set in0_min 1.4
#    set in0_max 1.6
#    set in1_min 1.4
#    set in1_max 1.6
#    set in2_min 3.2
#    set in2_max 3.4
#    set in3_min 3.1
#    set in3_max 3.3
#    set in4_min 1.4
#    set in4_max 1.5
#    set in5_min 2.6
#    set in5_max 2.65
#    set in6_min 5 * 0.95
#    set in6_max 5 * 1.05
#    set in7_min 5 * 0.95
#    set in7_max 5 * 1.05
#    set in8_min 3 * 0.95
#    set in8_max 3 * 1.05

# fan1 adjustments examples

#   set fan1_div 4
#   set fan1_min 1500

# temp2 limits examples

#    set temp2_over 42
#    set temp2_hyst 37

# ignore examples

#    ignore fan7
#    ignore temp3


# Here are configurations for Winbond W83793 chip.
chip "w83793-*"

    label in0 "VCoreA"
    label in1 "VCoreB"
    label in2 "Vtt"
    label in5 "+3.3V"
    label in6 "+12V"
    label in7 "+5V"
    label in8 "5VSB"
    label in9 "VBAT"

    compute in6 12*@ ,  @/12

    label temp1 "CPU1 Temp"
    label temp2 "CPU2 Temp"

# fan1 adjustments examples

#   set fan1_min 1500

# temp2 limits examples

#   set temp2_max       45
#   set temp2_max_hyst  40

# ignore examples

#    ignore fan7
#    ignore temp3


chip "as99127f-*"

# Asus won't release a datasheet so this is guesswork.
# Thanks to Guntram Blohm, Jack, Ed Harrison, Artur Gawryszczak,
# Victor G. Marimon and others for their feedback.

# Dual power plane
    label in0 "VCore 1"
    label in1 "VCore 2"
# Single power plane (A7V133, A7M266, CUV4X)
#   label in0 "VCore"
#   ignore in1

    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
# These last two may not make sense on all motherboards.
    label in5 "-12V"
    label in6 "-5V"

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    compute in4 ((28/10)+1)*@  ,  @/((28/10)+1)
# AS99127F rev.1 (same as w83781d)
    compute in5 -(240/60.4)*@ ,  -@/(240/60.4)
    compute in6 -(90.9/60.4)*@ ,  -@/(90.9/60.4)
# AS99127F rev.2 (same as w83782d)
#   compute in5 (5.14 * @) - 14.91 , (@ + 14.91) / 5.14
#   compute in6 (3.14 * @) -  7.71 , (@ +  7.71) / 3.14

# Depending on your motherboard, you may have to use any of two formulae
# for temp2. Quoting Artur Gawryszczak (edited to reflect subsequent fixes
# to the driver):
# "I guess, that the formula "(@*15/43)+25, (@-25)*43/15" is correct
# for those Asus motherboards, which get CPU temperature from internal
# thermal diode (Pentium Coppermine, and above), while no formula is needed
# for Athlon/Duron boards, which use a thermistor in the socket."
# An alternative formula was then found and reported by Victor G. Marimon.

# Asus A7V133, Asus A7M266
#   No compute line is needed
# Asus CUV4X, Asus A7V8X
#   compute temp2 (@*15/43)+25, (@-25)*43/15
# Asus CUSL2, Asus CUV266-DLS, Asus TUSL2-C
#   compute temp2 (@*30/43)+25, (@-25)*43/30

# See comments above if temp3 looks bad. What works for temp2 is likely
# to work for temp3 for dual-CPU boards, such as the CUV4X-D.

# Most Asus boards have temperatures settled like that:
    label temp1 "M/B Temp"
    label temp2 "CPU Temp"
# However, some boards have them swapped (A7N8X Deluxe rev.2,
# A7N8X-E Deluxe rev.2, CUV4X):
#   label temp1 "CPU Temp"
#   label temp2 "M/B Temp"

# Most boards have no temp3 by default, except for dual-CPU boards.
#   label temp3 "CPU 2 Temp"
#   ignore temp3

# adjust this if your vid is wrong; see doc/vid
#   set vrm 9.0

# set limits to  5% for the critical voltages
# set limits to 10% for the non-critical voltages
# set limits to 20% for the battery voltage

#    set in0_min vid*0.95
#    set in0_max vid*1.05
#    set in1_min vid*0.95
#    set in1_max vid*1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
#    set in4_min 12 * 0.90
#    set in4_max 12 * 1.10
#    set in5_max -12 * 0.90
#    set in5_min -12 * 1.10
#    set in6_max -5 * 0.95
#    set in6_min -5 * 1.05

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47
#    set temp3_over 52
#    set temp3_hyst 47


chip "gl518sm-*"

# IMPORTANT: in0, in1, and in2 values (+5, +3, and +12) CANNOT be read
#            unless you use the slow 'iterate' method. Limits will still
#            work even when iterate=0. See doc/chips/gl518sm.
#            Note that the 'iterate' method was trimmed while porting the
#            driver to Linux 2.6 as we considered it too ugly for the thin
#            benefit.
#
# Factors and labels taken from GL518SM datasheet, they seem to give
# reasonable values with EISCA connected Fan78

  label vdd "+5V"
  label vin1 "+3.3V"
  label vin2 "+12V"
  label vin3 "Vcore"

# vin2 depends on external resistors (4,7k and 15k assumed here)
# vin1 and vin3 require no scaling

  compute vin2 (197/47)*@  ,  @/(197/47)

#  set vdd_min 4.8
#  set vdd_max 5.2
#  set vin1_min 3.20
#  set vin1_max 3.40
#  set vin2_min 11.0
#  set vin2_max 13.0
#  set vin3_min 2.10
#  set vin3_max 2.30
#  set fan1_off 0
#  set fan2_min 0

# Do NOT uncomment the following line with the Linux 2.6 kernel driver,
# as it'll raise an error.
# set iterate 2


chip "gl520sm-*"

# Factors and labels taken from GL520SM datasheet

# The GL520SM has two application modes. In mode 1 it has two thermistor
# inputs, in mode 2 it has only one and an extra (negative) voltage input.
# The mode is supposed to be set properly by your BIOS so you should not
# need to change it. You can force it below if really needed though.
# Note that this means that you have either temp2 or vin4 but never both
# at the same time.

# set two_temps 1

  label vdd "+5V"
  label vin1 "+3.3V"
  label vin2 "+12V"
  label vin3 "Vcore"
  label vin4 "-12V"

# vin1 and vin3 require no scaling
# vin2 depends on external resistors (4,7k and 15k assumed)

# vin4 = ((R1+R2)/R2)*@ - (R1/R2)*vdd
#
#       -12 --| R1 |---t---| R2 |-- +5
#                      |
#                    vin4
#

  compute vin2 (197/47)*@  ,  @/(197/47)
  compute vin4 (5*@)-(4*vdd) , (@+4*vdd)/5

#  set vdd_min 4.8
#  set vdd_max 5.2
#  set vin1_min 3.20
#  set vin1_max 3.40
#  set vin2_min 11.0
#  set vin2_max 13.0
#  set vin3_min 2.10
#  set vin3_max 2.30


chip "lm80-*"

# The values below should be correct if you own a qdi BX (brilliant1)
# mainboard. If not, please contact us, so we can figure out better readings.
# Many thanks go to Peter T. Breuer <ptb@it.uc3m.es> for helping us figure
# out how to handle the LM80.

# For positive voltages (in0..in4), two resistors are used, with the following
# formula (R1,R2: resistor values, Vs: read voltage, Vin: pin voltage)
#   R1 = R2 * (Vs/Vin - 1)
# For negative voltages (in5, in6) two resistors are used, with the following
# formula (R3,R4: resistor values, Vs: read voltage, Vin: pin voltage,
# V5: +5V)
#   R3 = R4 * (Vs - Vin) / (Vin - V5)

# Here are the official LM80 data sheet values.
#       Vs      R1,R3   R2,R4    Vin
#       +2.5V    23.7    75     +1.9
#       +3.3V    22.1    30     +1.9
#       +5.0     24      14.7   +1.9
#      +12.0    160      30.1   +1.9
#      -12.0    160      35.7   +1.9
#       -5.0     36      16.2   +1.9

# Now curiously enough, VCore is connected with (unknown) resistors, which
# translate a +2.8V to +1.9V. So we use that in the computations below.

    label in0 "+5V"
    label in1 "VTT"
    label in2 "+3.3V"
    label in3 "+Vcore"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"

    compute in0 (24/14.7 + 1) * @ ,       @ / (24/14.7 + 1)
    compute in2 (22.1/30 + 1) * @ ,       @ / (22.1/30 + 1)
    compute in3 (2.8/1.9) * @,            @ * 1.9/2.8
    compute in4 (160/30.1 + 1) * @,       @ / (160/30.1 + 1)
    compute in5 (160/35.7)*(@ - in0) + @, (@ + in0 * 160/35.7)/ (1 + 160/35.7)
    compute in6 (36/16.2)*(@ - in0) + @,  (@ + in0 * 36/16.2) / (1 + 36/16.2)

#    set in0_min 5 * 0.95
#    set in0_max 5 * 1.05
# What is your VTT? It is probably not this value...
#    set in1_min 2*0.95
#    set in1_max 2*1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
# What is your VCore? It is probably not this value...
#    set in3_min 1.9 * 0.95
#    set in3_max 1.9 * 1.05
#    set in4_min 12 * 0.95
#    set in4_max 12 * 1.05
#    set in5_min -12 * 1.05
#    set in5_max -12 * 0.95
#    set in6_min -5 * 1.05
#    set in6_max -5 * 0.95

# examples for lm80 temperature limits
# WARNING - nonstandard names and functions for the lm80!!!
# All 4 of these limits apply to the single temperature sensor.
# "hot" is like the standard alarm for most chips.
# "os" is the threshold for the overtemperature shutdown output.
# "os" may or may not do anything on your motherboard but it should
#  be set higher than the "hot" thresholds.
# Note that the /proc file 'temp" also has five entries instead of
# the usual three.
#    set temp_hot_hyst 45
#    set temp_hot_max  52
#    set temp_os_hyst  57
#    set temp_os_max   62


chip "maxilife-cg-*" "maxilife-co-*" "maxilife-as-*"

   label fan1  "HDD Fan"
   label fan2  "PCI Fan"
   label fan3  "CPU Fan"
   ignore fan4

   label temp2 "PCI Temp"
   label temp4 "HDD Temp"
   label temp5 "CPU Temp"
   ignore temp6

   label vid1  "V+12"
   ignore vid5

# vid1 need to be scaled by 6.337 other voltages
# require no scaling

   compute vid1 6.337*@ , @/6.337


chip "maxilife-cg-*"

   ignore temp1
   label temp3  "BX Temp"

   label vid2   "Vcpu1"
   label vid3   "Vcpu2"
   ignore vid4


chip "maxilife-co-*"

   label temp1  "CPU 1 Temp"
   label temp3  "CPU 2 Temp"

   label vid2   "Vcpu1"
   label vid3   "Vcpu2"
   label vid4   "VcacheL2"


chip "maxilife-as-*"

   ignore temp1
   ignore temp3

   label vid2   "Vcpu"
   ignore vid3
   ignore vid4


chip "maxilife-nba-*"

   label fan1  "CPU Fan"
   label fan2  "PCI Fan"
   label fan3  "HDD Fan"
   label fan4  "Heat Sink Fan"

   label temp1  "CPU 1 Temp"
   label temp2  "CPU 2 Temp"
   label temp3  "PCI/Ambient Temp"
   label temp4  "HDD Temp"
   label temp5  "Motherboard Temp"
   label temp6  "CPU Reference Temp"

   label vid1  "V+12"
   label vid2  "Vcpu1"
   label vid3  "Vcpu2"
   label vid4  "VcacheL2"
   label vid5  "V-12"


chip "via686a-*"

# VIA is very specific about the voltage sensor inputs, and our labels
# reflect what they say.  Unfortunately, they are not at all specific about
# how to convert any of the register values to real units.  Fortunately,
# Jonathan Yew <j.teh@iname.com> and Alex van Kaam <darkside@chello.nl>
# came through with some data for temp conversion and formulae for voltage
# conversion. However, the conversions should be regarded as our best guess-
# YMMV.

# On the Tyan S1598, the 2.5V sensor reads 0 and is not displayed in the BIOS.
# Linas Vepstas <linas@linas.org> reports that this sensor shows nothing of
# interest on the Abit KA7 (Athlon), and is also not displayed in the BIOS.
# Likewise, Johannes Drechsel-Burkhard <jdb@chello.at> reports that this
# sensor is unavailable in the BIOS of his MSI K7T Pro (Thunderbird).  So,
# if you have one of these boards you may want to uncomment the 'ignore 2.5V'
# line below.

    label "2.0V" "CPU core"
    label "2.5V" "+2.5V"
    #ignore "2.5V"
    label "3.3V" "I/O"
    label "5.0V" "+5V"
    label "12V" "+12V"

    label fan1  "CPU Fan"
    label fan2  "P/S Fan"

# VIA suggests that temp3 is an internal temp sensor for the 686a.  However,
# on the Tyan S1598 as well as the Abit KA7 (Athalon), the absolute values
# of the readings from that sensor are not valid.  The readings do seem to
# correlate with temp changes, but the conversion factor may be quite
# different from temp1 & temp2 (as noted above, VIA has not provided
# conversion info).  So, you may wish to 'ignore temp3'.

# Johannes Drechsel-Burkhard <jdb@chello.at> notes that on his MSI K7T Pro,
# temp1 is the CPU temp and temp2 is the SYS temp. Hugo van der Merwe notes
# the same for his Gigabyte GA-7DXC, Olivier Martin for his Gigabyte
# GA-7ZM and Patrick Thomson for his Chaintech CT-5ATA.
# Thomas Anglmaier notes: on Epox EP-7kxa temp2 is CPU and temp1 is SYS.

    label temp1 "SYS Temp"
    label temp2 "CPU Temp"
    label temp3 "SBr Temp"
    #ignore temp3

# Set your CPU core limits here if the BIOS did not.

    #set in0_min 1.70 * 0.95
    #set in0_max 1.70 * 1.05

# Other voltage values are standard so we can enforce the limits.

#    set in1_min 2.5 * 0.95
#    set in1_max 2.5 * 1.05
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5 * 0.9
#    set in3_max 5 * 1.1
#    set in4_min 12 * 0.9
#    set in4_max 12 * 1.1

# Set your temp limits here.  Remember, 'tempX_over' is the temp at which an
# alarm is triggered, and 'tempX_hyst' is the temp at which an alarm turns off.
# Setting tempX_hyst to a few degrees below the corresponding tempX_over
# prevents an oscillation between alarm on and off states.  This kind of
# oscillation is known as hyteresis, thus the name.  (You typically get the
# most serious and troublesome hysteresis when a sensor triggers something to
# reduce the temp, thus creating a negative feedback loop.  Even without that,
# we would still get some oscillation when the temp hovers around the limit
# due to noise.)

#    set temp1_hyst 40
#    set temp1_over 45
#    set temp2_hyst 55
#    set temp2_over 60
#    set temp3_hyst 60
#    set temp3_over 65

# You could set your fan limits too, but the defaults should be fine.

    #set fan1_min 5000
    #set fan2_min 5000


chip "mtp008-*"

# The values below should be correct if you own a Tyan S1834D motherboard.
# If not, please contact us, so we can figure out better readings.
# FOR TYAN S2510 SEE END OF THIS SECTION.

# For positive voltages outside the 0..4.09V range (in2..in4), two resistors
# are used, with the following formula (R1,R2: resistor values, Vs: read
# voltage, Vin: pin voltage)
#   Vin = Vs * (R2 / (R1 + R2))
# For negative voltages (in5) two resistors are used, with the following
# formula (R3,R4: resistor values, Vs: read voltage, Vin: pin voltage)
#   Vin = ((4.096 - Vs) * (R3 / (R3 + R4))) + Vs

# Here are the official MTP008 data sheet values:
#       Vs      R1,R3   R2,R4    Vin
#      +12.0    28000   10000   +3.16
#      -12.0   232000   56000   +0.96
#       -5.0   120000   56000   +1.20

    label in0 "VCore1"
    label in1 "+3.3V"
    label in2 "+12V"
    label in3 "Vcore2"
    ignore in4
    label in5 "-12V"
    label in6 "Vtt"

    label fan1 "CPU1 Fan"
    label fan2 "CPU2 Fan"
    label fan3 "fan3"

    label temp1 "CPU1 Temp"
    label temp2 "CPU2 Temp"
    ignore temp3

    compute in2 @ * 38 / 10,		@ * 10 / 38
    compute in5 (@ * 36 - 118.61) / 7,	(118.61 + 7 * @) / 36

# examples for temperature limits
#    set temp1_over 40
#    set temp1_hyst 37
#    set temp2_over 52
#    set temp2_hyst 47
#    set temp3_over 52
#    set temp3_hyst 47

# End of standard mtp008 configuration

# TYAN S2510 INFORMATION
# This motherboard has two mtp008's which are hooked up differently,
# so they must be configured separately.
# For this motherboard, COMMENT OUT the above mtp008 section and
# UNCOMMENT the following two sections.
#
#chip "mtp008-i2c-*-2c"
#    label in0 "VCore1"
#    set in0_min 1.60
#    set in0_max 1.80
#    label in1 "+3.3V"
#    label in2 "+12V"
#    label in3 "Vcore2"
#    set in3_min 1.60
#    set in3_max 1.80
#    ignore in4
#    label in5 "-12V"
#    label in6 "Vtt"
#    label fan1 "CPU1 Fan"
#    label fan2 "CPU2 Fan"
#    label fan3 "fan3"
#    label temp1 "CPU1 Temp"
#    label temp2 "CPU2 Temp"
#    ignore temp3
#    compute in2 @ * 38 / 10,		@ * 10 / 38
#    compute in5 (@ * 36 - 118.61) / 7,	(118.61 + 7 * @) / 36
#
#chip "mtp008-i2c-*-2e"
#    ignore in0
#    label in1 "+3.3V"
#    ignore in2
#    label in3 "+5V"
#    set in3_min 4.50
#    set in3_max 5.50
#    ignore in4
#    label in5 "+3.3V"
#    ignore in6
#    label fan1 "fan4"
#    label fan2 "fan5"
#    label fan3 "fan6"
#    ignore temp1
#    label temp2 "MB Temp"
#    set temp2_over 52
#    set temp2_hyst 47
#    ignore temp3

chip "adm1025-*" "ne1619-*"

# The ADM1025 has integrated scaling resistors, rather
# than external resistors common to most sensor devices.
# These apply to the 6 voltage inputs in0-in5 (+2.5V, VCore,
# +3.3V, +5V, +12V, VCC). As the scaling is fixed inside
# the chip for these inputs, it is fairly certain that the
# motherboard connections match these labels, and that the
# driver computations are correct. Therefore they do not need to
# be overridden here.

    label in0 "+2.5V"
    label in1 "VCore"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "VCC"

# Adjust this if your vid is wrong; see doc/vid
#   set vrm 9.0

# Tolerate a 5% deviance for CPU power-supply
#    set in1_min vid * 0.95
#    set in1_max vid * 1.05
# Tolerate a 10% deviance for other voltages
#    set in0_min 2.5 * 0.90
#    set in0_max 2.5 * 1.10
#    set in2_min 3.3 * 0.90
#    set in2_max 3.3 * 1.10
#    set in3_min 5.0 * 0.90
#    set in3_max 5.0 * 1.10
#    set in4_min 12 * 0.90
#    set in4_max 12 * 1.10
#    set in5_min 3.3 * 0.90
#    set in5_max 3.3 * 1.10

# Depending on how your chipset is hardwired, you may or may not have
# +12V readings (will show as 0.0V if you don't have it).
#   ignore in4

# VCC is the power-supply voltage of the ADM1025 chipset, generally
# redundant with +3.3V so you may want to hide it.
#   ignore in5

# Temperatures
    label temp1 "CPU Temp"
    label temp2 "M/B Temp"
#    set temp1_low 10
#    set temp1_high 60
#    set temp2_low 10
#    set temp2_high 45


chip "lm87-*"
#
# The LM87 has integrated scaling resistors, rather
# than external resistors common to most sensor devices.
# These apply to the first 6 voltage inputs in0-in5
# (+2.5, Vccp1, +3.3, +5, 12, +Vccp2). As the scaling is fixed inside
# the chip for these inputs, it is fairly certain that the
# motherboard connections match these labels, and that the
# driver computations are correct. Therefore they do not need to
# be overridden here.
#
# Note: AIN1 (-12?), AIN2 (-5?) and temp3 require changing
# #defines in the driver and recompiling!!!
# This does not apply to the Linux 2.6 driver.
#
# This chip has non-standard entries in lib/chips.c so
# the feature names are quite different from other chips.
# For this chip, libsensors anticipates the correct labeling.
# This is great if it's correct but makes it a little more
# difficult if you want to change it.
#
# This may not have been a good idea, so it may be changed in the future.
# Here is an entry with everything commented out so you can
# uncomment the appropriate line if you want to change it.
#
# Warning - feature names starting with a number must be enclosed
# with double quotes.

   label "2.5V"  "+2.5V"
   label Vccp1   "VCore"
   label "3.3V"  "+3.3V"
   label "5V"    "+5V"
   label "12V"   "+12V"
#   label Vccp2   "VCore2"

   label fan1 "CPU Fan"
#   label fan2 "Case Fan"
   label temp1 "M/B Temp"
   label CPU_Temp "CPU Temp"
#   label temp3 "AUX Temp"

#   set Vccp1_min    vid * 0.95
#   set Vccp1_max    vid * 1.05
#   set "3.3V_min"   3.3 * 0.92
#   set "3.3V_max"   3.3 * 1.08
#   set "5V_min"       5 * 0.92
#   set "5V_max"       5 * 1.08
#   set "12V_min"     12 * 0.90
#   set "12V_max"     12 * 1.10

# These ones are mutually exclusive with temp3. If you have temp3,
# comment out these lines as they will trigger errors on "sensors -s".
#   set "2.5V_min"   2.5 * 0.92
#   set "2.5V_max"   2.5 * 1.08
#   set Vccp2_min    vid * 0.95
#   set Vccp2_max    vid * 1.05

# Increase fan clock dividers if your fans read 0 RPM while you know
# they are connected and running.
#   set fan1_div 4
#   set fan2_div 4

#   set fan1_min 3000
#   set fan2_min 3000

#   set temp1_min   5
#   set temp1_max  65
#   set temp2_min   5
#   set temp2_max  70

# Uncomment if you actually have temp3 (which means you don't have 2.5V
# nor Vccp2, as they are mutually exclusive).
#   set temp3_min   5
#   set temp3_max  70

# LM87 AIN1 and AIN2 Section
# As described above, the driver must be recompiled to use either or
# both of these. -12 and -5 may be reversed on your board, this is
# just a guess, the datasheet gives no guidance.
# Note that the Linux 2.6 driver needs no recompilation, it'll read the
# configuration from the chip.
#   label AIN1 "-12V"
#   label AIN2 "-5V"
#   set AIN1_min -12 * 0.95
#   set AIN2_min -5 * 0.95
#   set AIN1_max -12 * 1.05
#   set AIN2_max -5 * 1.05
#   compute AIN1 (7.50 * @) - 21.45  ,  (@ + 21.45) / 7.50
#   compute AIN2 (4.05 * @) - 10.07  ,  (@ + 10.07) / 4.05

chip "adm9240-*" "ds1780-*" "lm81-*"
#
# These chips have non-standard entries in lib/chips.c so
# the feature names are quite different from other chips.
# For these chips, libsensors anticipates the correct labeling.
# This is great if it's correct but makes it a little more
# difficult if you want to change it.
#
# This may not have been a good idea, so it may be changed in the future.
# Here is an entry with everything commented out so you can
# uncomment the appropriate line if you want to change it.
#
# Warning - feature names starting with a number must be enclosed
# with double quotes.
#
#   label "2.5V" "xxx"
#   label Vccp1 "xxx"
#   label "3.3V" "xxx"
#   label "5V" "xxx"
#   label "12V" "xxx"
#   label Vccp2 "xxx"
#   label fan1 "xxx"
#   label fan2 "xxx"
#   label temp "xxx"
#
#   set Vccp1_min xxx
#   set "2.5V_min" xxx
#   set "3.3V_min" xxx
#   set "5V_min" xxx
#   set "12V_min" xxx
#   set Vccp2_min xxx
#
#   set Vccp1_max xxx
#   set "2.5V_max" xxx
#   set "3.3V_max" xxx
#   set "5V_max" xxx
#   set "12V_max" xxx
#   set Vccp2_max xxx
#
#   set fan1_div xxx	Note: do not uncomment with kernel 2.6 driver
#   set fan2_div xxx	Note: do not uncomment with kernel 2.6 driver
#   set fan1_min xxx
#   set fan2_min xxx
#   set temp1_hyst xxx
#   set temp1_over xxx

#   compute "2.5V" xxx
#   compute Vccp1 xxx
#   compute "3.3V" xxx
#   compute "5V" xxx
#   compute "12V" xxx
#   compute Vccp2 xxx
#   compute temp xxx

chip "adm1024-*"
#
# These settings work for me, adjust for your system
#
    label fan1 "CPU1 fan"
    label fan2 "CPU2 fan"
    label temp "SYS Temp"
    label temp1 "CPU2 Temp"
    label temp2 "CPU1 Temp"
    ignore "2.5V" # This register is also used for temp2
    ignore "Vccp1"
    ignore "Vccp2"


chip "it87-*" "it8712-*"

# The values below have been tested on Asus CUSI, CUM motherboards.

# Voltage monitors as advised in the It8705 data sheet

    label in0 "VCore 1"
    label in1 "VCore 2"
    label in2 "+3.3V"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "-12V"
    label in6 "-5V"
    label in7 "Stdby"
    label in8 "VBat"

    # vid is not monitored by IT8705F
    # comment out if you have IT8712
    ignore  vid

# Incubus Saturnus reports that the IT87 chip on Asus A7V8X-X seems
# to report the VCORE voltage approximately 0.05V higher than the board's
# BIOS does. Although it doesn't make much sense physically, uncommenting
# the next line should bring the readings in line with the BIOS' ones in
# this case.
# compute in0 -0.05+@ , @+0.05

# If 3.3V reads around 1.65V, uncomment the following line:
#    compute in2   2*@ , @/2

    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
# A number of Gigabyte boards (GA-8IPE1000Pro, GA-8KNXP, GA-7N400-L) use
# a different resistor combination for +5V:
#    compute in3 ((10/10)+1)*@ ,  @/((10/10)+1)

    compute in4 ((30/10) +1)*@  , @/((30/10) +1)
# For this family of chips the negative voltage equation is different from
# the lm78.  The chip uses two external resistor for scaling but one is
# tied to a positive reference voltage.  See ITE8705/12 datasheet (SIS950
# data sheet is wrong)
# Vs = (1 + Rin/Rf) * Vin - (Rin/Rf) * Vref.
# Vref = 4.096 volts, Vin is voltage measured, Vs is actual voltage.

# The next two are negative voltages (-12 and -5).
# The following formulas must be used. Unfortunately the datasheet
# does not give recommendations for Rin, Rf, but we can back into
# them based on a nominal +2V input to the chip, together with a 4.096V Vref.
# Formula:
#    actual V = (Vmeasured * (1 + Rin/Rf)) - (Vref * (Rin/Rf))
#    For -12V input use Rin/Rf = 6.68
#    For -5V input use Rin/Rf = 3.33
# Then you can convert the forumula to a standard form like:
    compute in5 (7.67 * @) - 27.36  ,  (@ + 27.36) / 7.67
    compute in6 (4.33 * @) - 13.64  ,  (@ + 13.64) / 4.33
#
# this much simpler version is reported to work for a
# Elite Group K7S5A board
#
#   compute in5 -(36/10)*@, -@/(36/10)
#   compute in6 -(56/10)*@, -@/(56/10)
#
    compute in7 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)

#    set in0_min 1.5 * 0.95
#    set in0_max 1.5 * 1.05
#    set in1_min 2.4
#    set in1_max 2.6
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
#    set in4_min 12 * 0.95
#    set in4_max 12 * 1.05
#    set in5_max -12 * 0.95
#    set in5_min -12 * 1.05
#    set in6_max -5 * 0.95
#    set in6_min -5 * 1.05
#    set in7_min 5 * 0.95
#    set in7_max 5 * 1.05
    #the chip does not support in8 min/max

# Temperature
#
# Important - if your temperature readings are completely whacky
# you probably need to change the sensor type.
# Adujst and uncomment the appropriate lines below.
# The old method (modprobe it87 temp_type=0xXX) is no longer supported.
#
# 2 = thermistor; 3 = thermal diode; 0 = unused
#   set sensor1 3
#   set sensor2 3
#   set sensor3 3
# If a given sensor isn't used, you will probably want to ignore it
# (see ignore statement right below).

    label temp1       "M/B Temp"
#    set   temp1_over  40
#    set   temp1_low   15
    label temp2       "CPU Temp"
#    set   temp2_over  45
#    set   temp2_low   15
#   ignore temp3
    label temp3       "Temp3"
#    set   temp3_over  45
#    set   temp3_low   15

# The A7V8X-X has temperatures inverted, and needs a conversion for
# CPU temp. Thanks to Preben Randhol for the formula.
#   label temp1       "CPU Temp"
#   label temp2       "M/B Temp"
#   compute temp1     (-15.096+1.4893*@), (@+15.096)/1.4893

# The A7V600 also has temperatures inverted, and needs a different
# conversion for CPU temp. Thanks to Dariusz Jaszkowski for the formula.
#   label temp1       "CPU Temp"
#   label temp2       "M/B Temp"
#   compute temp1     (@+128)/3, (3*@-128)

# Fans
#   set fan1_min 0
#   set fan2_min 3000
#   ignore fan3
#   set fan3_min 3000

# The following is for the Inside Technologies 786LCD which uses either a
# IT8705F or a SIS950 for monitoring with the SIS630.
#
# delete or comment out above it87 section and uncomment the following.
#chip "it87-*"
#    label in0 "VCore 1"
#    label in1 "VCore 2"
#    label in2 "+3.3V"
#    label in3 "+5V"
#    label in4 "+12V"
#    label in5 "3.3 Stdby"
#    label in6 "-12V"
#    label in7 "Stdby"
#    label in8 "VBat"
    # in0 will depend on your processor VID value, set to voltage specified in
    # bios setup screen
#    set in0_min 1.7 * 0.95
#    set in0_max 1.7 * 1.05
#    set in1_min 2.4
#    set in1_max 2.6
#    set in2_min 3.3 * 0.95
#    set in2_max 3.3 * 1.05
#    set in3_min 5.0 * 0.95
#    set in3_max 5.0 * 1.05
    # +- 12V are very poor tolerance on this board. Verified with voltmeter
#    set in4_min 12 * 0.90
#    set in4_max 12 * 1.10
#    set in5_min 3.3 * 0.95
#    set in5_max 3.3 * 1.05
#    set in6_max -12 * 0.90
#    set in6_min -12 * 1.10
#    set in7_min 5 * 0.95
#    set in7_max 5 * 1.05
    # vid not monitored by IT8705F
#    ignore  vid

#    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
#    compute in4 ((30/10) +1)*@  , @/((30/10) +1)
#    compute in6 (1+232/56)*@ - 4.096*232/56, (@ + 4.096*232/56)/(1+232/56)
#    compute in7 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
    # Temperature
#    label temp1       "CPU Temp"
#    ignore temp2
#    ignore temp3
    # Fans
#    set fan1_min 3000
#    ignore fan2
#    ignore fan3


chip "it8716-*"

# Voltages

    label  in0  "VCore"
    label  in1  "VDDR"
    label  in2  "+3.3V"    # VCC3
    label  in3  "+5V"      # VCC
    label  in4  "+12V"
#   label  in5  "-12V"
#   label  in6  "-5V"
    label  in7  "5VSB"     # VCCH
    label  in8  "VBat"

    compute in3  ((6.8/10)+1)*@ , @/((6.8/10)+1)
    compute in4  ((30/10)+1)*@  , @/((30/10)+1)
#   compute in5  (1+232/56)*@ - 4.096*232/56 , (@ + 4.096*232/56)/(1+232/56)
#   compute in6  (1+120/56)*@ - 4.096*120/56 , (@ + 4.096*120/56)/(1+120/56)
    compute in7  ((6.8/10)+1)*@ , @/((6.8/10)+1)

# If vid (nominal CPU voltage) isn't correct, hardcode the correct value
# instead.
#    set in0_min  vid * 0.95
#    set in0_max  vid * 1.05
#    set in1_min  1.8 * 0.95
#    set in1_max  1.8 * 1.05
#    set in2_min  3.3 * 0.95
#    set in2_max  3.3 * 1.05
#    set in3_min    5 * 0.95
#    set in3_max    5 * 1.05
#    set in4_min   12 * 0.95
#    set in4_max   12 * 1.05
#    set in5_max  -12 * 0.95
#    set in5_min  -12 * 1.05
#    set in6_max   -5 * 0.95
#    set in6_min   -5 * 1.05
#    set in7_min    5 * 0.95
#    set in7_max    5 * 1.05
# The chip does not support in8 min/max

# Temperatures

# If you are lucky, the BIOS has set the proper sensor types for you.
# If your temperature readings are completely whacky you probably
# need to change the sensor types. Adujst and uncomment the
# appropriate lines below.
#
# 2 = thermistor; 3 = thermal diode; 0 = unused
#   set sensor1  3
#   set sensor2  3
#   set sensor3  3

# If a given sensor isn't used, you will probably want to ignore it
# as well (see ignore statement right below).
# The CPU sensor can be any of temp1, temp2 or temp3 - it's motherboard
# dependent. Same for the motherboard temperature.

#   label  temp1  "CPU Temp"
#   label  temp2  "M/B Temp"
#   ignore temp3

#   set temp1_over  60
#   set temp1_low   10
#   set temp2_over  50
#   set temp2_low   10

# Fans

# The CPU fan can be any of fan1, fan2 or fan3 - it's motherboard
# dependent. Same for the case fan.

#   label  fan1 "CPU Fan"
#   label  fan2 "Case Fan"
#   ignore fan3

#   set fan1_min 2000
#   set fan2_min 2000


chip "fscpos-*"
# Fujitsu-Siemens Poseidon chip

# Temperature

    label temp1       "Temp1/CPU"
    label temp2       "Temp2/MB"
    label temp3       "Temp3/AUX"

# Fans

    label fan1        "Fan1"
    label fan2        "Fan2"
    label fan3        "Fan3"

# Voltage

    label volt12      "+12V"
    label volt5       "+5V"
    label voltbatt    "Battery"


chip "fscscy-*"
# Fujitsu-Siemens Scylla chip

# Temperature

    label temp1       "Temp1/CPU0"
    label temp2       "Temp2/CPU1"
    label temp3       "Temp3/MB"
    label temp4       "Temp4/AUX"

# Fans

    label  fan1       "Fan1/CPU0"
    label  fan2       "Fan2/CPU0"
    label  fan3       "Fan3"
    label  fan4       "Fan4"
    label  fan5       "Fan5"
    label  fan6       "Fan6"

# Voltage

    label volt12      "+12V"
    label volt5       "+5V"
    label voltbatt    "+3.3V"


chip "fscher-*"
# Fujitsu-Siemens Hermes chip

# Temperature
    label temp1       "Temp1/CPU"
    label temp2       "Temp2/MB"
    label temp3       "Temp3/AUX"

# Fans
    label fan1        "Fan1/PS"
    label fan2        "Fan2/CPU"
    label fan3        "Fan3/AUX"

# Voltage
    label in0         "+12V"
    label in1         "+5V"
    label in2         "Battery"

# Note: comment the compute lines below when using the newer unified fschmd
# driver, as that driver does the scaling in the driver

# Compute Voltages using mainboard dependant MRO-values
# (see doc/chips/fscher)
#                           M    R             O               O                  M    R
    compute in0       (@ * (49 * 33) / 255) + (0 / 100), (@ - (0 / 100)) * 255 / (49 * 33)
    compute in1       (@ * (20 * 33) / 255) + (0 / 100), (@ - (0 / 100)) * 255 / (20 * 33)
    compute in2       (@ * (10 * 33) / 255) + (0 / 100), (@ - (0 / 100)) * 255 / (10 * 33)

# Read documentation before enabling pwm settings (see doc/chips/fscher)
# WARNING: IMPROPER VALUES MAY DAMAGE YOUR SYSTEM DUE TO OVERHEATING!

# Note these set statements will not work with the newer unified fschmd driver
# The functionality is still available using standard sysfs attributes for
# pwm control: pwm#_auto_point1_pwm (which are not accessible through sensors)

# Allow fans to turn off
#    set pwm1          0
#    set pwm2          0
#    set pwm3          0

# Min cooling
#    set pwm1          2
#    set pwm2          1
#    set pwm3          1

# Max cooling
#    set pwm1          255
#    set pwm2          255
#    set pwm3          255


chip "pcf8591-*"
#
#    values for the Philips PCF8591 chip
#
# Analog inputs

   ignore ain_conf
# Since Linux 2.6, input configuration is set as module parameter,
# so the line below is for older kernels only.
#  set    ain_conf    0

# You may discard ch2 and ch3 if you don't use them (depends on the input
# configuration)
#  ignore ch2
#  ignore ch3

   label  ch0         "Chan. 0"
   label  ch1         "Chan. 1"
   label  ch2         "Chan. 2"
   label  ch3         "Chan. 3"

# The driver assumes Vref = 2.56V and Agnd = 0V. If it doesn't match
# your hardware, you have to use compute lines. The example below is
# correct for Vref = 5.0V and Agnd = 0V.
#  compute ch0 (@ * 500 / 256), (@ * 256 / 500)
#  compute ch1 (@ * 500 / 256), (@ * 256 / 500)
#  compute ch2 (@ * 500 / 256), (@ * 256 / 500)
#  compute ch3 (@ * 500 / 256), (@ * 256 / 500)

# Analog output

   ignore aout_enable
#   set    aout_enable 1
   label  aout        "Output"
#   set    aout        0

chip "adm1021-*" "adm1023-*" "max1617-*" "max1617a-*" "thmc10-*" "lm84-*" "gl523sm-*" "mc1066-*"

   label temp 		"Board Temp"
   label remote_temp	"CPU Temp"
#   set temp_low		40
#   set temp_over		70
#   set remote_temp_low		40
#   set remote_temp_over	70

chip "lm83-*"

   label temp1 "M/B Temp"
   label temp2 "D1 Temp"
   label temp3 "CPU Temp"
   label temp4 "D3 Temp"

# ignore D1 and/or D3 readings if not used
#   ignore temp2
#   ignore temp4

# change high limits to fit your needs
#   set temp1_high 55
#   set temp2_high 60
#   set temp3_high 65
#   set temp4_high 60

# change critical limit to fit your needs
# only one limit for all four temperatures
# should be higher than each of the high limits above
#   set tcrit 85


chip "max1619-*"

   label temp1 "M/B Temp"
   label temp2 "CPU Temp"

# change high and low limits to fit your needs
#   set temp2_min   10
#   set temp2_max   100

# change critical limit and hysteresis to fit your needs
#   set temp2_crit  50
#   set temp2_hyst  40


chip "lm90-*" "adm1032-*" "lm86-*" "max6657-*" "adt7461-*" "max6680-*"

   label temp1 "M/B Temp"
   label temp2 "CPU Temp"
   label tcrit1 "M/B Crit"
   label tcrit2 "CPU Crit"

# change high and low limits to fit your needs
#   set temp1_low  10
#   set temp1_high 55
#   set temp2_low  10
#   set temp2_high 66

# change critical limits to fit your needs
# should be higher than the corresponding high limit above
#   set tcrit1 75
#   set tcrit2 85

# change the hysteresis values (to critical limits) to fit your needs
# note #1: hyst2 will be automatically set with the same delta
# note #2: the internal register, which stores a single, relative value
# for both channels, cannot hold values greater than 31, so the delta
# between critical temperatures and respective absolute hysteresis can
# never exceed this value
#   set hyst1 70

chip "lm99-*"

   label temp1 "G/C Temp"
   label temp2 "GPU Temp"
   label tcrit1 "G/C Crit"
   label tcrit2 "GPU Crit"

# note #1: only the LM99 needs this; for a LM89, comment the compute line
# out
# note #2: there is no way for us to differentiate between a LM89 and a
# LM99; you have to know what you have; LM99 are frequently found on
# graphics cards, most notably nVidia ones
   compute temp2 @+16, @-16

# change high and low limits to fit your needs
#   set temp1_low  10
#   set temp1_high 90
#   set temp2_low  10
#   set temp2_high 100

# change critical limits to fit your needs
# should be higher than the corresponding high limit above
#   set tcrit1 100
#   set tcrit2 110

# change the hysteresis values (to critical limits) to fit your needs
# note #1: hyst2 will be automatically set with the same delta
# note #2: the internal register, which stores a single, relative value
# for both channels, cannot hold values greater than 31, so the delta
# between critical temperatures and respective absolute hysteresis can
# never exceed this value
#   set hyst1 105


chip "lm63-*"

   label temp1       "M/B Temp"
   label temp2       "CPU Temp"
   label temp2_crit  "CPU Crit"
   label fan1        "CPU Fan"

# Change limits to fit your needs. Note that temp2_crit is read-only.
#   set temp1_high       50
#   set temp2_low        10
#   set temp2_high       70
#   set temp2_crit_hyst  75
#   set fan1_min         2000


chip "vt1211-*"

#							1 for temp, 0 for volt.
#	Sensor		Voltage Mode	Temp Mode	config bit
#	--------	------------	---------	--------------
#	Reading 1			temp1
#	Reading 3			temp2
#	UCH1/Reading2	in0		temp3		0x04 (4)
#	UCH2		in1		temp4		0x08 (8)
#	UCH3		in2		temp5		0x10 (16)
#	UCH4		in3		temp6		0x20 (32)
#	UCH5		in4		temp7		0x40 (64)
#	3.3V		in5

# Set uch1-2 to temp mode, uch3-5 to voltage mode. This works only
# for the 2.4 driver. For the 2.6 driver use the uch_config module parameter.
# If the value doesn't match the hardware wiring, you'll get weird readings!
#    set config 12

# The 2.6 driver will automatically ignore the inputs which are not
# configured, but the 2.4 driver will not so you'll need to add ignore
# statements depending on the config value above.
#   ignore in0
#   ignore in1
#   ignore temp3
#   ignore temp4
    ignore temp5
    ignore temp6
    ignore temp7

    label in0 "+3.3V"
    label in1 "+2.5V"
    label in2 "VCore"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "+3.3V"

    label temp1 "CPU Temp"
    label temp2 "Int Temp"

    label fan1 "Case Fan"
    label fan2 "CPU Fan"

# All voltage calculations have the form
#    compute inX  @ * (1 + R1 / R2), @ / (1 + R1 / R2)
#
# The following are the resistor values as recommended by VIA
#	Voltage		R1	R2
#	-------		----	----
#	VCore	 	-	-	(no scaling)
#	 3.3		6.8k	10k
#	 2.5		2k	10k
#	 5.0		14k	10k
#	12.0		47k	10k
#
# The VT1211 internal 3.3V (in5) is scaled by the driver and doesn't
# need to be adjusted here. VCore doesn't need scaling at all.

    compute in0  @ * (1 + 6.8 / 10),  @ / (1 + 6.8 / 10)
    compute in1  @ * (1 +   2 / 10),  @ / (1 +   2 / 10)
    compute in3  @ * (1 +  14 / 10),  @ / (1 +  14 / 10)
    compute in4  @ * (1 +  47 / 10),  @ / (1 +  47 / 10)

# Adjust this if your vid is wrong (for 2.4 only); see doc/vid
#   set vrm 9.1

#   set in0_min 3.3 * 0.95
#   set in0_max 3.3 * 1.05
#   set in1_min 2.5 * 0.95
#   set in1_max 2.5 * 1.05
# If your vid is wrong, hardcode the CPU voltage (e.g. 1.4)
#   set in2_min vid * 0.97
#   set in2_max vid * 1.03
#   set in3_min 5.0 * 0.95
#   set in3_max 5.0 * 1.05
#   set in4_min 12.0 * 0.90
#   set in4_max 12.0 * 1.10
    set in5_min 3.3 * 0.95
    set in5_max 3.3 * 1.05

# The temperature calculations are of the form
#    compute tempX  (@ - Offset) / Gain, (@ * Gain) + Offset
#
# The following are the gain and offset values as recommended by VIA
#	Diode Type	Gain	Offset
#	----------	----	------
# 	Intel CPU	0.9528	88.638
#			0.9686	65.000	*)
#	VIA C3 Ezra	0.9528	83.869
#	VIA C3 Ezra-T	0.9528	73.869
#
# *) These are the values from the previous sensors.conf. I don't know
# where they came from or how they got derived.
#
# The VT1211 internal temperature (temp2) is scaled by the driver
# and doesn't need to be adjusted here.

    compute temp1  (@ - 73.869) / 0.9528,  (@ * 0.9528) + 73.869

# The thermistor calculations are of the form
#    compute tempX  1 / (1 / 298.15 - (` Vmax / @ - 1)) / B) - 273.15, \
#                   Vmax / (1 + (^ (B / 298.15 - B / (273.15 + @))))
#
# B is the thermistor beta value, Vmax is the reference voltage, '^' is the
# exp() operator and '`' is the ln() operator.
# Given B = 3435 and Vmax = 2.2V and assuming that the thermistor forms a
# resistor divider with a resistor equal to the thermistor's nominal value at
# 25 degrees C, the following compute lines can be used:

    compute temp3  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))
    compute temp4  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))
    compute temp5  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))
    compute temp6  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))
    compute temp7  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))

#    set temp1_hyst 80
#    set temp1_over 85
#    set temp2_hyst 60
#    set temp2_over 65
#    set temp3_hyst 60
#    set temp3_over 65
#    set temp4_hyst 40
#    set temp4_over 45

#    set fan1_min 3000
#    set fan2_min 3000

chip "vt8231-*"
#
#							1 for temp, 0 for volt.
#	Sensor		Voltage Mode	Temp Mode	config bit
#	--------	------------	---------	--------------
#	Reading 1			temp1
#	UCH1		in0		temp2		0x04 (4)
#	UCH2		in1		temp3		0x08 (8)
#	UCH3		in2		temp4		0x10 (16)
#	UCH4		in3		temp5		0x20 (32)
#	UCH5		in4		temp6		0x40 (64)
#	3.3V		in5
#
# Hardware default is UCH1 in temp mode, UCH2-5 in voltage mode
# Note that the Linux 2.6 driver will not let you change the channel
# configuration. In theory, the BIOS should have done it properly.
#   set config 4

#    ignore in0
#    ignore temp3
#    ignore temp4
#    ignore temp5
#    ignore temp6

    label in1 "+2.5V"
    label in2 "VCore"
    label in3 "+5V"
    label in4 "+12V"
    label in5 "+3.3V"

    label temp1 "CPU Temp"
    label temp2 "M/B Temp"

# Here are the resistor values as recommended by VIA:
#   Voltage			R1	R2
#   VCore			no scaling
#    2.5			2k	10k
#    3.5 (3.3V ext.)		6.8k	10k
#    5.0			14k	10k
#   12.0			47k	10k

#   compute in0  @ * (1 + 6.8 / 10),  @ / (1 + 6.8 / 10)
    compute in1  @ * (1 +   2 / 10),  @ / (1 +   2 / 10)
    compute in3  @ * (1 +  14 / 10),  @ / (1 +  14 / 10)
    compute in4  @ * (1 +  47 / 10),  @ / (1 +  47 / 10)
# in5 is scaled internally so scaling is done by the driver.

#   set in0_min 2.5 * 0.95
#   set in0_max 2.5 * 1.05
#   set in1_min 2.5 * 0.95
#   set in1_max 2.5 * 1.05
# Replace "2.0" with your nominal CPU voltage for in2.
#   set in2_min 2.0 * 0.95
#   set in2_max 2.0 * 1.05
#   set in3_min 5.0 * 0.95
#   set in3_max 5.0 * 1.05
#   set in4_min 12.0 * 0.95
#   set in4_max 12.0 * 1.05
#   set in5_min 3.3 * 0.95
#   set in5_max 3.3 * 1.05

# For Intel CPU:
    compute temp1  (@ - 65) / 0.9686,  (@ * 0.9686) + 65

# For VIA EPIA CPU (provided by Roger Lucas):
#   compute temp1  (@ - 45) / 0.7809,  (@ * 0.7809) + 45

# Thermistor calculations
# 3435 is the thermistor beta, 2.2 is the reference voltage.
# '^' is the e**x operator; '`' is the ln(x) operator
# (valid in library version 1.4.0 / lm_sensors 2.7.1 or higher)
# This assumes that the thermistor forms a resistor divider with a resistor
# equal to its nominal value at 25 degrees C.

    compute temp2  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))
    compute temp3  1 / (1 / 298.15 - (` (2.2 / @ - 1)) / 3435) - 273.15, \
                   2.2 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))

#    set temp1_hyst 60
#    set temp1_over 65
#    set temp2_hyst 40
#    set temp2_over 45

#    set fan1_min 3000
#    set fan2_min 3000

chip "bmc-*"
#
# You should not need compute lines here, the driver will
# do all the conversions.
# For label lines, copy from syslog/dmesg when the bmcsensors
# module is inserted.
#
# for example:
# label temp1 "Ambient Temp"


chip "smsc47m1-*"

# SMSC LPC47M10x, LPC47M13x, LPC47M14x and LPC47B27x chips

# We don't set the fan mins by default anymore because they may not exist
# when using the Linux 2.6 driver (since we respect the original chip
# configuration).
#    set fan1_min 3000
#    set fan2_min 3000

chip "smsc47m192-*"

# Temperature and voltage input from SMSC LPC47M192 and LPC47M997 chips
# This example works on a Gigabyte K8U motherboard
# Voltages are scaled internally, no computations needed

    label in0 "+2.5V"
#    set in0_min  2.5 * 0.95
#    set in0_max  2.5 * 1.05

    label in1 "VCore"
#    set in1_min  vid * 0.95
#    set in1_max  vid * 1.05

    label in2 "+3.3V"
#    set in2_min  3.3 * 0.95
#    set in2_max  3.3 * 1.05

    label in3 "+5V"
#    set in3_min  5.0 * 0.95
#    set in3_max  5.0 * 1.05

    label in4 "+12V"
#    set in4_min  12.0 * 0.95
#    set in4_max  12.0 * 1.05

    label in5 "VCC"
#    set in5_min  3.3 * 0.95
#    set in5_max  3.3 * 1.05

    label in6 "+1.5V"
#    set in6_min  1.5 * 0.95
#    set in6_max  1.5 * 1.05
#   ignore in6

    label in7 "+1.8V"
#    set in7_min  1.8 * 0.95
#    set in7_max  1.8 * 1.05
#   Haven't yet heard from any board that has 1.8V connected, so
#   this might be more appropriate:
#   ignore in7

    label temp1 "Chip Temp"
#    set temp1_min   0
#    set temp1_max   60

    label temp2 "CPU Temp"
#    set temp2_min   0
#    set temp2_max   60

    label temp3 "Sys Temp"
#    set temp3_min   0
#    set temp3_max   60

#
# This example was tested vs. Asus P4S333
#
chip "asb100-*"
# adjust this if your vid is wrong; see doc/vid
    #set vrm 9.0

    label in0 "VCore 1"
    #set in0_min vid * 0.95
    #set in0_max vid * 1.05

    label in1 "VCore 2"
    ignore in1
    #set in1_min vid * 0.95
    #set in1_max vid * 1.05

    label in2 "+3.3V"
    #set in2_min 3.3 * 0.95
    #set in2_max 3.3 * 1.05

    label in3 "+5V"
    compute in3 1.68 * @ ,  @ / 1.68
    #set in3_min 5.0 * 0.95
    #set in3_max 5.0 * 1.05

    label in4 "+12V"
    compute in4 3.8 * @ , @ / 3.8
    #set in4_min 12  * 0.90
    #set in4_max 12  * 1.10

    label in5 "-12V (reserved)"
    #ignore in5
    compute in5 -@ * 3.97 ,  -@ / 3.97
    #set in5_max -12 * 0.90
    #set in5_min -12 * 1.10

    label in6 "-5V (reserved)"
    #ignore in6
    compute in6 -@ * 1.666 , -@ / 1.666
    #set in6_max -5  * 0.95
    #set in6_min -5  * 1.05

    label temp1 "M/B Temp"
    #set temp1_over 45
    #set temp1_hyst 40

    label temp2 "CPU Temp (Intel)"
    #ignore temp2
    #set temp2_over 60
    #set temp2_hyst 50

    # PWRTMP connector on P4S333, for external sensor
    label temp3 "Power Temp"
    #ignore temp3
    #set temp3_over 45
    #set temp3_hyst 40


    # Used for Athlon diode, ignore for P4S333
    label temp4 "CPU Temp (AMD)"
    #set temp4_over 60
    #set temp4_hyst 50
    #ignore temp4

    label fan1 "CPU Fan"
    #set fan1_div 4
    #set fan1_min 2000

    label fan2 "Chassis Fan"
    #set fan2_div 2
    #set fan2_min 4000

    label fan3 "Power Fan"
    #set fan3_div 2
    #set fan3_min 4000

#
# Sample configuration for the Intel S845WD1-E
# courtesy of Marcus Schopen
#
chip "lm85c-*" "adm1027-*" "adt7463-*" "lm85-*" "lm85b-*"

# Voltage inputs
# Depending on the hardware setup, the ADT7463 may not have in4.
   label in0   "V1.5"      # AGP on Intel S845WD1-E
   label in1   "VCore"
   label in2   "V3.3"
   label in3   "V5"
   label in4   "V12"

# Temperature inputs
   label temp1  "CPU Temp"
   label temp2  "Board Temp"
   label temp3  "Remote Temp"

# Fan inputs
   label fan1   "CPU_Fan"
#   label fan2   "Fan2"
#   label fan3   "Fan3"
#   label fan4   "Fan4"

# PWM Outputs
   label pwm1   "CPU_PWM"
   label pwm2   "Fan2_PWM"
   label pwm3   "Fan3_PWM"

# Voltage scaling is done on-chip.  No 'compute' directive
# should be necessary.  If in0 has external scaling set
# it here.

#   compute in0  @ * 2.5,   @ / 2.5

# Adjust fans speeds for actual pulses per rev
#   compute fan1  @ * 2,  @ / 2    # 1 pulse per rev
#   set fan1_ppr  1                # ADM1027 or ADT7463
#   compute fan2  @ / 2,  @ * 2    # 4 pulse per rev
#   set fan2_ppr  4                # ADM1027 or ADT7463

# Ignore fans you (or your motherboard) don't have
#   ignore fan2
#   ignore fan3
#   ignore fan4

# Set VRM version
# adjust this if your vid is wrong; see doc/vid
#   set vrm  9.1   # Pentium 4

# Set voltage limits
#   set in0_min  1.5 * 0.95
#   set in0_max  1.5 * 1.05
#   set in1_min  vid * 0.95
#   set in1_max  vid * 1.05
#   set in2_min  3.3 * 0.95
#   set in2_max  3.3 * 1.05
#   set in3_min  5.0 * 0.95
#   set in3_max  5.0 * 1.05
#   set in4_min   12 * 0.95
#   set in4_max   12 * 1.05

# Set Fan limits
#   set fan1_min 4000

# Set Temp Limits
#   set temp1_min 10
#   set temp1_max 50
#   set temp2_min 10
#   set temp2_max 35
#   set temp3_min 10
#   set temp3_max 35

chip "pc87366-*"

# Voltage inputs

# Set VRM version (default 9.0)
#   set vrm     9.0

   label in7   "Vsb"
   label in8   "Vdd"
   label in9   "Vbat"
   label in10  "AVdd"

   compute in7   @*2, @/2
   compute in8   @*2, @/2
   compute in10  @*2, @/2

# These are the operating conditions as recommended by National
# Semiconductor
   set in7_min   3.0
   set in7_max   3.6
   set in8_min   3.0
   set in8_max   3.6
#   set in9_min   2.4
#   set in9_max   3.6
   set in10_min  3.0
   set in10_max  3.6

# Temperature inputs

   label temp1       "CPU0 Temp"
   label temp1_crit  "CPU0 Crit"
   label temp2       "CPU1 Temp"
   label temp2_crit  "CPU1 Crit"
   label temp3       "S-IO Temp"
   label temp3_crit  "S-IO Crit"

#   set temp1_min    0
#   set temp1_max   70
#   set temp1_crit  85
#   set temp2_min    0
#   set temp2_max   70
#   set temp2_crit  85
#   set temp3_min    0
#   set temp3_max   70
#   set temp3_crit  85

# Thermistors
# On some systems, thermistors are used instead of thermal diodes.
# Note that these are the same pins used differently, so you really
# can't have them all on a given system.
#   ignore temp1
#   ignore temp2
   ignore temp4
   ignore temp5
   ignore temp6

# 3435 is the thermistor beta.
# This assumes that the thermistor forms a resistor divider with a resistor
# equal to its nominal value at 25 degres Celsius. If not, change the values.
# We also assume that you have a working in10 (which is forcibly enabled by
# default). If not, use 3.3 instead, but you lose accuracy.

   compute temp4  3435 / (` (1 / (1 - @ / in10) - 1) + 3435 / 298.15) - 273.15, \
                  in10 * (1 - 1 / (1 + (^ (3435 / (273.15 + @) - 3435 / 298.15))))
   compute temp5  3435 / (` (1 / (1 - @ / in10) - 1) + 3435 / 298.15) - 273.15, \
                  in10 * (1 - 1 / (1 + (^ (3435 / (273.15 + @) - 3435 / 298.15))))
   compute temp6  3435 / (` (1 / (1 - @ / in10) - 1) + 3435 / 298.15) - 273.15, \
                  in10 * (1 - 1 / (1 + (^ (3435 / (273.15 + @) - 3435 / 298.15))))

#   set temp4_min    0
#   set temp4_max   70
#   set temp4_crit  85
#   set temp5_min    0
#   set temp5_max   70
#   set temp5_crit  85
#   set temp6_min    0
#   set temp6_max   70
#   set temp6_crit  85

# Fan inputs

# Ignore fans you don't have
#   ignore fan2
#   ignore fan3

#   set fan1_min 2000
#   set fan2_min 2000
#   set fan3_min 2000


chip "adm1030-*"

   label temp1 "SYS Temp"
   label temp2 "CPU Temp"
   label temp1_crit "SYS Crit"
   label temp2_crit "CPU Crit"

#   set temp1_max  60
#   set temp2_max  70
#   set temp1_crit 85
#   set temp2_crit 85

   label fan1 "CPU Fan"

#   set fan1_min 2000


chip "adm1031-*"

   label temp1 "SYS Temp"
   label temp2 "CPU Temp"
   label temp3 "AUX Temp"
   label temp1_crit "SYS Crit"
   label temp2_crit "CPU Crit"
   label temp3_crit "AUX Crit"

#   set temp1_max  60
#   set temp2_max  70
#   set temp3_max  70
#   set temp1_crit 85
#   set temp2_crit 85
#   set temp3_crit 85

   label fan1 "CPU Fan"
   label fan2 "Case Fan"

#   set fan1_min 2000
#   set fan2_min 2000


chip "w83l785ts-*"

   label temp1 "CPU Diode"

chip "lm92-*"

   label temp "CPU Temp"

# Change limits as you see fit
#   set temp_low 14
#   set temp_high 60
#   set temp_crit 72
# Hysteresis is computed from critical limit for Linux 2.6,
# and from high limit for Linux 2.4. That might change in the future.
# Whatever, the same relative hysteresis is used for all of low, high
# and critical limits.
#   set temp_hyst 70 # Linux 2.6
#   set temp_hyst 58 # Linux 2.4


# Winbond W83627EHF configuration originally contributed by Leon Moonen
# This is for an Asus P5P800, voltages for A8V-E SE.
chip "w83627ehf-*" "w83627dhg-*"

    label in0 "VCore"
    label in2 "AVCC"
    label in3 "3VCC"
    label in7 "VSB"
    label in8 "VBAT"

# The W83627DHG has no in9, uncomment the following line
#    ignore in9

# +12V is in1 and +5V is in6 as recommended by datasheet
    compute in1 @*(1+(56/10)),  @/(1+(56/10))
    compute in6 @*(1+(22/10)),  @/(1+(22/10))
#    set in1_min   12.0*0.9
#    set in1_max   12.0*1.1
#    set in6_min   5.0*0.95
#    set in6_max   5.0*1.05

# Set the 3.3V
#    set in2_min   3.3*0.95
#    set in2_max   3.3*1.05
#    set in3_min   3.3*0.95
#    set in3_max   3.3*1.05
#    set in7_min   3.3*0.95
#    set in7_max   3.3*1.05
#    set in8_min   3.3*0.95
#    set in8_max   3.3*1.05

# Fans
   label fan1      "Case Fan"
   label fan2      "CPU Fan"
   label fan3      "Aux Fan"
#  ignore fan3
#  ignore fan4
#  set fan1_min    1200
#  set fan2_min    1700

# Temperatures
   label temp1     "Sys Temp"
   label temp2     "CPU Temp"
   label temp3     "AUX Temp"

#  ignore temp3
#  set temp1_over  45
#  set temp1_hyst  40
#  set temp2_over  45
#  set temp2_hyst  40


# Fintek F71805F/FG configuration
# This is the recommended wiring and resistor values from the F71805F/FG
# datasheet. Your motherboard manufacturer may or may not have followed
# these.
chip "f71805f-*"
# Voltages
   label in0 "+3.3V"
   label in1 "Vtt1.2V"
   label in2 "Vram"
   label in3 "Vchip"
   label in4 "+5V"
   label in5 "+12V"
   label in6 "Vcc1.5V"
   label in7 "Vcore"
   label in8 "5VSB"

   # in0 is scaled internally
   compute in2  @*(1+100/100), @/(1+100/100)
   compute in3  @*(1+100/47),  @/(1+100/47)
   compute in4  @*(1+200/47),  @/(1+200/47)
   compute in5  @*(1+200/20),  @/(1+200/20)
   compute in8  @*(1+200/47),  @/(1+200/47)

   # in0 is the chip's own VCC.
   set in0_min  3.0
   set in0_max  3.6

   #set in1_min  1.2 * 0.95
   #set in1_max  1.2 * 1.05
   #set in2_min  2.5 * 0.95
   #set in2_max  2.6 * 1.05
   #set in3_min  3.3 * 0.95
   #set in3_max  3.3 * 1.05
   #set in4_min  5.0 * 0.95
   #set in4_max  5.0 * 1.05
   #set in5_min 12.0 * 0.95
   #set in5_max 12.0 * 1.05
   #set in6_min  1.5 * 0.95
   #set in6_max  1.5 * 1.05
   # in7 nominal value depends on the CPU model
   #set in7_min  1.4 * 0.95
   #set in7_max  1.4 * 1.05
   #set in8_min  5.0 * 0.95
   #set in8_max  5.0 * 1.05

# Fans
   label fan1 "CPU Fan"
   label fan2 "Sys Fan"
   label fan3 "Aux Fan"

   #set fan1_min 2100
   #set fan2_min 1400
   #set fan3_min 1400

# Temperatures
   label temp1 "CPU Temp"
   label temp2 "Sys Temp"
   label temp3 "Aux Temp"

   #set temp1_max   60
   #set temp1_hyst  58
   #set temp2_max   50
   #set temp2_hyst  48
   #set temp3_max   50
   #set temp3_hyst  48


# Abit Uguru sensor part configuration.
# The Abit Uguru is relativly straight forward to configure.
# label statements:
# The voltage (in) temp and fan sensors are usualy in the same order as listed
# in the BIOS, but not always!
# compute statements:
# The temp and fan sensors don't need any compute statements. Most voltage
# inputs are directly connected to the IC and thus don't need an compute line
# because the 0-3494 mV voltage given by the kernel driver is correct. The sen-
# sors for higher voltages however are connect through a divider and measure
# ranges of: 0-4361mV, 0-6248mV or 0-14510mV. Thus the measured voltages must
# be multiplied by resp. 1.248, 1.788 or 4.153. 3.3 volt sources use the 1.248
# mutiplier, 5 volt the 1.788 and 12 volt the 4.153.
# set statements:
# The Abit BIOS sets reasonable treshholds and allows changing them, thus
# set statements may be ommited. The abituguru kernel driver does support
# them if you want to add them.
#
# The configuration below is for the Kv8Pro and AV8 this is the default as this
# driver is developed and tested on a Kv8Pro.
# Configurations for many other Abit boards can be found at:
# http://www.lm-sensors.org/trac/wiki/Configurations/Abit
# If your motherboard isn't listed there and you create a configuration for it
# please add it there.

chip "abituguru-*"

   label in0 "CPU Core Voltage"
   label in1 "DDR Voltage"
   label in2 "DDR VTT Voltage"
   label in3 "NB Voltage"
   label in4 "SB Voltage"
   label in5 "HyperTransport Voltage"
   label in6 "AGP VDDQ Voltage"
   label in7 "ATX +5V"
   compute in7 @*1.788 , @/1.788
   label in8 "ATX +3.3V"
   compute in8 @*1.248 , @/1.248
   label in9 "Standby Voltage (+5V)"
   compute in9 @*1.788 , @/1.788
   label in10 "3VDual Voltage"
   compute in10 @*1.248 , @/1.248

   label temp1 "CPU Temperature"
   label temp2 "SYS Temperature"
   label temp3 "PWM Temperature"
   ignore temp4
   ignore temp5
   ignore temp6
   ignore temp7

   label fan1 "CPU FAN Speed"
   label fan2 "NB FAN Speed"
   label fan3 "SYS FAN Speed"
   label fan4 "AUX1 FAN Speed"
   label fan5 "AUX2 FAN Speed"
   ignore fan6

chip "k8temp-*"

   label temp1 "Core0 Temp"
   label temp2 "Core0 Temp"
   label temp3 "Core1 Temp"
   label temp4 "Core1 Temp"


#
# Sample configuration for the SMSC DME1737 and ASUS A8000
#
chip "dme1737-*"

# Voltage inputs
   label in0   "V5stby"
   label in1   "Vccp"
   label in2   "V3.3"
   label in3   "V5"
   label in4   "V12"
   label in5   "V3.3stby"
   label in6   "Vbat"

# Temperature inputs
   label temp1   "RD1 Temp"
   label temp2   "Int Temp"
   label temp3   "CPU Temp"

# Fan inputs
   label fan1   "CPU_Fan"
   label fan2   "Fan2"
   label fan3   "Fan3"
   label fan4   "Fan4"
   label fan5   "Fan5"
   label fan6   "Fan6"

# PWM Outputs
   label pwm1   "CPU_PWM"
   label pwm2   "Fan2_PWM"
   label pwm3   "Fan3_PWM"
   label pwm5   "Fan5_PWM"
   label pwm6   "Fan6_PWM"

# Set voltage limits
#   set in0_min   5.0 * 0.95
#   set in0_max   5.0 * 1.05
#   set in1_min   1.4 * 0.95
#   set in1_max   1.4 * 1.05
#   set in2_min   3.3 * 0.95
#   set in2_max   3.3 * 1.05
#   set in3_min   5.0 * 0.95
#   set in3_max   5.0 * 1.05
#   set in4_min  12.0 * 0.95
#   set in4_max  12.0 * 1.05
#   set in5_min   3.3 * 0.95
#   set in5_max   3.3 * 1.05
#   set in6_min   3.0 * 0.95
#   set in6_max   3.0 * 1.05

# Set Temp Limits
#   set temp1_min 10
#   set temp1_max 75
#   set temp2_min 10
#   set temp2_max 75
#   set temp3_min 10
#   set temp3_max 75

# Set Fan limits
#   set fan1_min 1000
#   set fan2_min 1000
#   set fan3_min 1000
#   set fan4_min 1000
#   set fan5_min 1000
#   set fan6_min 1000


#
# sample configuration for the Fintek f71882fg and f71883fg
#
# The configuration below is for the Epox EP-9U1697 GLI board, which has a
# Fintek f71883fg relabeled as Epox ep1308, this is the default config as this
# driver is developed and tested on an Epox EP-9U1697 GLI board.
#
# Premade configurations for other boards can be found at:
# http://www.lm-sensors.org/trac/wiki/Configurations/
# If your motherboard isn't listed there and you create a configuration for it
# please add it there.
#
chip "f71882fg-*"

# Temperature
    label temp1       "CPU"
    label temp2       "System"
    ignore temp3

# Fans
    label fan1        "CPU"
    label fan2        "System"
    label fan3        "Power"
    label fan4        "Aux"

# Voltage
    label in0         "3.3V"
    label in1         "Vcore"
    label in2         "Vdimm"
    label in3         "Vchip"
    label in4         "+5V"
    label in5         "12V"
    label in6         "5VSB"
    label in7         "3VSB"
    label in8         "Battery"

# never change the in0, in7 and in8 compute, these are hardwired in the chip!
    compute in0       (@ * 2), (@ / 2)
    compute in2       (@ * 2), (@ / 2)
    compute in3       (@ * 2), (@ / 2)
    compute in4       (@ * 5.25), (@ / 5.25)
    compute in5       (@ * 12.83), (@ / 12.83)
    compute in6       (@ * 5.25), (@ / 5.25)
    compute in7       (@ * 2), (@ / 2)
    compute in8       (@ * 2), (@ / 2)


chip "adm1022-*" "thmc50-*"

   label temp "M/B Temp"
   # Single CPU setup
   label remote_temp "CPU Temp"

   # Dual CPU setup (ADM1022 only)
   #label remote_temp "CPU0 Temp"
   #label remote_temp2 "CPU1 Temp"

Back to top

/etc/sestatus.conf File

 -rw-r--r-- 1 root root 216  Feb 10 21:12 2011  Jan  7 14:29 2010  sestatus.conf
[files]
/etc/passwd
/etc/shadow
/bin/bash
/bin/login
/bin/sh
/sbin/agetty
/sbin/init
/sbin/mingetty
/usr/sbin/sshd
/lib/libc.so.6
/lib/ld-linux.so.2
/lib/ld.so.1

[process]
/sbin/mingetty
/sbin/agetty
/usr/sbin/sshd

Back to top

/etc/smartd.conf File

 -rw-r--r-- 1 root root 6463  Feb 10 21:11 2011  Aug  7 11:16 2008  smartd.conf
# Sample configuration file for smartd.  See man smartd.conf.

# Home page is: http://smartmontools.sourceforge.net

# $Id: smartd.conf,v 1.45 2006/11/12 23:39:04 dpgilbert Exp $

# smartd will re-read the configuration file if it receives a HUP
# signal

# The file gives a list of devices to monitor using smartd, with one
# device per line. Text after a hash (#) is ignored, and you may use
# spaces and tabs for white space. You may use '\' to continue lines.

# You can usually identify which hard disks are on your system by
# looking in /proc/ide and in /proc/scsi.

# The word DEVICESCAN will cause any remaining lines in this
# configuration file to be ignored: it tells smartd to scan for all
# ATA and SCSI devices.  DEVICESCAN may be followed by any of the
# Directives listed below, which will be applied to all devices that
# are found.  Most users should comment out DEVICESCAN and explicitly
# list the devices that they wish to monitor.
DEVICESCAN -H -m root

# Alternative setting to ignore temperature and power-on hours reports
# in syslog.
#DEVICESCAN -I 194 -I 231 -I 9

# Alternative setting to report more useful raw temperature in syslog.
#DEVICESCAN -R 194 -R 231 -I 9

# Alternative setting to report raw temperature changes >= 5 Celsius
# and min/max temperatures.
#DEVICESCAN -I 194 -I 231 -I 9 -W 5

# First (primary) ATA/IDE hard disk.  Monitor all attributes, enable
# automatic online data collection, automatic Attribute autosave, and
# start a short self-test every day between 2-3am, and a long self test
# Saturdays between 3-4am.
#/dev/hda -a -o on -S on -s (S/../.././02|L/../../6/03)

# Monitor SMART status, ATA Error Log, Self-test log, and track
# changes in all attributes except for attribute 194
#/dev/hdb -H -l error -l selftest -t -I 194

# Monitor all attributes except normalized Temperature (usually 194),
# but track Temperature changes >= 4 Celsius, report Temperatures
# >= 45 Celsius and changes in Raw value of Reallocated_Sector_Ct (5).
# Send mail on SMART failures or when Temperature is >= 55 Celsius.
#/dev/hdc -a -I 194 -W 4,45,55 -R 5 -m admin@example.com

# An ATA disk may appear as a SCSI device to the OS. If a SCSI to
# ATA Translation (SAT) layer is between the OS and the device then
# this can be flagged with the '-d sat' option. This situation may
# become common with SATA disks in SAS and FC environments.
# /dev/sda -a -d sat

# A very silent check.  Only report SMART health status if it fails
# But send an email in this case
#/dev/hdc -H -C 0 -U 0 -m admin@example.com

# First two SCSI disks.  This will monitor everything that smartd can
# monitor.  Start extended self-tests Wednesdays between 6-7pm and
# Sundays between 1-2 am
#/dev/sda -d scsi -s L/../../3/18
#/dev/sdb -d scsi -s L/../../7/01

# Monitor 4 ATA disks connected to a 3ware 6/7/8000 controller which uses
# the 3w-xxxx driver. Start long self-tests Sundays between 1-2, 2-3, 3-4,
# and 4-5 am.
# NOTE: starting with the Linux 2.6 kernel series, the /dev/sdX interface
# is DEPRECATED.  Use the /dev/tweN character device interface instead.
# For example /dev/twe0, /dev/twe1, and so on.
#/dev/sdc -d 3ware,0 -a -s L/../../7/01
#/dev/sdc -d 3ware,1 -a -s L/../../7/02
#/dev/sdc -d 3ware,2 -a -s L/../../7/03
#/dev/sdc -d 3ware,3 -a -s L/../../7/04

# Monitor 2 ATA disks connected to a 3ware 9000 controller which uses
# the 3w-9xxx driver (Linux, FreeBSD). Start long self-tests Tuesdays
# between 1-2 and 3-4 am.
#/dev/twa0 -d 3ware,0 -a -s L/../../2/01
#/dev/twa0 -d 3ware,1 -a -s L/../../2/03

# Same as above for Windows. Option '-d 3ware,N' is not necessary,
# disk (port) number is specified in device name.
# NOTE: On Windows, DEVICESCAN works also for 3ware controllers.
#/dev/hdc,0 -a -s L/../../2/01
#/dev/hdc,1 -a -s L/../../2/03

# Monitor 3 ATA disks directly connected to a HighPoint RocketRAID. Start long
# self-tests Sundays between 1-2, 2-3, and 3-4 am.
#/dev/sdd -d hpt,1/1 -a -s L/../../7/01
#/dev/sdd -d hpt,1/2 -a -s L/../../7/02
#/dev/sdd -d hpt,1/3 -a -s L/../../7/03

# Monitor 2 ATA disks connected to the same PMPort which connected to the
# HighPoint RocketRAID. Start long self-tests Tuesdays between 1-2 and 3-4 am
#/dev/sdd -d hpt,1/4/1 -a -s L/../../2/01
#/dev/sdd -d hpt,1/4/2 -a -s L/../../2/03

# HERE IS A LIST OF DIRECTIVES FOR THIS CONFIGURATION FILE.
# PLEASE SEE THE smartd.conf MAN PAGE FOR DETAILS
#
#   -d TYPE Set the device type: ata, scsi, marvell, removable, 3ware,N, hpt,L/M/N
#   -T TYPE set the tolerance to one of: normal, permissive
#   -o VAL  Enable/disable automatic offline tests (on/off)
#   -S VAL  Enable/disable attribute autosave (on/off)
#   -n MODE No check. MODE is one of: never, sleep, standby, idle
#   -H      Monitor SMART Health Status, report if failed
#   -l TYPE Monitor SMART log.  Type is one of: error, selftest
#   -f      Monitor for failure of any 'Usage' Attributes
#   -m ADD  Send warning email to ADD for -H, -l error, -l selftest, and -f
#   -M TYPE Modify email warning behavior (see man page)
#   -s REGE Start self-test when type/date matches regular expression (see man page)
#   -p      Report changes in 'Prefailure' Normalized Attributes
#   -u      Report changes in 'Usage' Normalized Attributes
#   -t      Equivalent to -p and -u Directives
#   -r ID   Also report Raw values of Attribute ID with -p, -u or -t
#   -R ID   Track changes in Attribute ID Raw value with -p, -u or -t
#   -i ID   Ignore Attribute ID for -f Directive
#   -I ID   Ignore Attribute ID for -p, -u or -t Directive
#   -C ID   Report if Current Pending Sector count non-zero
#   -U ID   Report if Offline Uncorrectable count non-zero
#   -W D,I,C Monitor Temperature D)ifference, I)nformal limit, C)ritical limit
#   -v N,ST Modifies labeling of Attribute N (see man page)
#   -a      Default: equivalent to -H -f -t -l error -l selftest -C 197 -U 198
#   -F TYPE Use firmware bug workaround. Type is one of: none, samsung
#   -P TYPE Drive-specific presets: use, ignore, show, showall
#    #      Comment: text after a hash sign is ignored
#    \      Line continuation character
# Attribute ID is a decimal integer 1 <= ID <= 255
# except for -C and -U, where ID = 0 turns them off.
# All but -d, -m and -M Directives are only implemented for ATA devices
#
# If the test string DEVICESCAN is the first uncommented text
# then smartd will scan for devices /dev/hd[a-l] and /dev/sd[a-z]
# DEVICESCAN may be followed by any desired Directives.

Back to top

/etc/smi.conf File

 -rw-r--r-- 1 root root 1272  May  3 02:09 2011  Jan  4 11:50 2008  smi.conf
#
# smi.conf - Global/User SMI configuration file.
#
# See smi_config(3) for detailed information on configuration files.
#

# Extend (note the semicolon) the libsmi default module search path.
#path :/usr/local/share/mibs/sun
#path :/usr/local/share/mibs/cisco

# Add a private directory.
#path :/home/strauss/lib/mibs

# EXPERIMENTAL: Add a caching method (works only on UNIX systems).
# NOTE: the cache directory must exist and permissions must be
# handled appropriately. A simple but insecure way is to apply
# a tmp flag to the directory (chmod 1777 /usr/local/share/mibs/cache).
#cache /usr/local/share/mibs/cache /usr/local/bin/smicache -d /usr/local/share/mibs/cache -p http://www.ibr.cs.tu-bs.de/projects/libsmi/smicache/

# Don't show any errors by default.
level 0

# Preload some basic SMIv2 modules.
load SNMPv2-SMI
load SNMPv2-TC
load SNMPv2-CONF

# Make smilint shout loud to report all errors and warnings.
smilint: level 9

# But please don't claim about any names longer than 32 chars.
# (note: this is the prefix of errors `namelength-32-module,
#  -type, -object, -enumeration, and -bit)
smilint: hide namelength-32

# Preloading some more modules for special applications.
tcpdump: load DISMAN-SCRIPT-MIB
tcpdump: load IF-MIB
smiquery: load IF-MIB

Back to top

/etc/sysctl.conf File

 -rw------- 1 root root 1832  Jun 13 15:29 2011  May 25 19:52 2011  sysctl.conf

Back to top

/etc/syslog.conf File

 -rw------- 1 root root 826  Apr 29 20:17 2011  Apr 29 20:17 2011  syslog.conf

Back to top

/etc/updatedb.conf File

 -rw-r--r-- 1 root root 136  Feb 10 21:11 2011  Mar 17 15:27 2009  updatedb.conf
PRUNEFS = "auto afs gfs gfs2 iso9660 sfs udf"
PRUNEPATHS = "/afs /media /net /sfs /tmp /udev /var/spool/cups /var/spool/squid /var/tmp"

Back to top

/etc/warnquota.conf File

 -rw-r--r-- 1 root root 2657  Feb 10 21:18 2011  Nov 24 13:52 2010  warnquota.conf
# this is an example warnquota.conf
#
; ; and # type comments are allowed
# and even blank lines

# values can be quoted:
MAIL_CMD 	= "/usr/sbin/sendmail -t"
FROM 		=
# but they don't have to be:
SUBJECT 	= NOTE: You are exceeding your allocated disk space limits
CC_TO 		= "root@localhost"
# If you set this variable CC will be used only when user has less than
# specified grace time left (examples of possible times: 5 seconds, 1 minute,
# 12 hours, 5 days)
# CC_BEFORE = 2 days
SUPPORT 	= "root@myhost.com"
PHONE 		= "(123) 456-1111 or (222) 333-4444"
# Text in the beginning of the mail (if not specified, default text is used)
# This way text can be split to more lines
# Line breaks are done by '|' character
MESSAGE         = Your disk usage has exceeded the agreed limits\
 on this server|Please delete any unnecessary files on following filesystems:|
# Text in the end of the mail (if not specified, default text using SUPPORT and PHONE
# is created)
SIGNATURE	= root@localhost
# Following text is used for mails about group exceeding quotas
# It should contain string %s exactly once - it will be substituted for a group name
GROUP_MESSAGE	= Hello, a group '%s' you're member of use too much space.|\
I chose you to do the cleanup.|Delete group files on following filesystems:|
# Text in the end of the mail to the group (if not specified, default text using SUPPORT
# and PHONE is created).
GROUP_SIGNATURE	= See you!|			Your admin|
#
#If you are running warnquota on a mail server, and don't want bounces
#because clients cannot receive mail setting this to "any" will cause
#warnquota to not send them mail for all devices.  If you set this to the
#device name (for example /dev/hdb1) then they will not be sent mail if they
#are overquota on that device only, and will be sent mail for all other
#devices.
#MAILDEV        =
#
# If you are using LDAP mail lookups.
# host, port, tls, binddn, and bindpw are straight forward.
# LDAP_BASEDN is your search base dn
# LDAP_SEARCH_ATTRIBUTE is the attr for the value you are looking for
# LDAP_MAIL_ATTRIBUTE is the attribute you want used for the mail address
# LDAP_DEFAULT_MAIL_DOMAIN is the default domain
#    if the attribute isn't found
# if binddn and bindpw are blank or left out, an anonymous bind is used
#
# LDAP_MAIL = false # or false if you don't want to use it
# LDAP_HOST = ldap
# LDAP_PORT = 389
# LDAP_BINDDN = uid=ReadOnlyUser,o=YourOrg
# LDAP_BINDPW = YourReadOnlyUserPassword
# LDAP_BASEDN = YourSearchBase
# LDAP_SEARCH_ATTRIBUTE = uid
# LDAP_MAIL_ATTRIBUTE = mailLocalAddress
# LDAP_DEFAULT_MAIL_DOMAIN = YourDefaultMailDomain.com
#
# end of example warnquota.conf file
#

Back to top

/etc/yp.conf File

 -rw-r--r-- 1 root root 585  Feb 10 21:11 2011  Apr 15 09:03 2009  yp.conf
# /etc/yp.conf - ypbind configuration file
# Valid entries are
#
# domain NISDOMAIN server HOSTNAME
#	Use server HOSTNAME for the domain NISDOMAIN.
#
# domain NISDOMAIN broadcast
#	Use  broadcast  on  the local net for domain NISDOMAIN
#
# domain NISDOMAIN slp
#	Query local SLP server for ypserver supporting NISDOMAIN
#
# ypserver HOSTNAME
#	Use server HOSTNAME for the  local  domain.  The
#	IP-address of server must be listed in /etc/hosts.
#
# broadcast
#	If no server for the default domain is specified or
#	none of them is rechable, try a broadcast call to
#	find a server.
#

Back to top

/etc/yum.conf File

 -rw-r--r-- 1 root root 364  Jun 14 15:56 2011  Jun 14 15:56 2011  yum.conf
[main]
cachedir=/var/cache/yum
keepcache=0
debuglevel=2
logfile=/var/log/yum.log
distroverpkg=redhat-release
tolerant=1
exactarch=1
obsoletes=1
gpgcheck=1
plugins=1
tsflags=repackage

# Note: yum-RHN-plugin doesn't honor this.
metadata_expire=1h

# Default.
# installonly_limit = 3

# PUT YOUR REPOS HERE OR IN separate files named file.repo
# in /etc/yum.repos.d

Back to top

/etc/security/limits.conf File

 -rw-r--r-- 1 root root 1891  Jun  6 16:17 2011  Jun  6 16:17 2011  limits.conf
# /etc/security/limits.conf
#
#Each line describes a limit for a user in the form:
#
#<domain>        <type>  <item>  <value>
#
#Where:
#<domain> can be:
#        - an user name
#        - a group name, with @group syntax
#        - the wildcard *, for default entry
#        - the wildcard %, can be also used with %group syntax,
#                 for maxlogin limit
#
#<type> can have the two values:
#        - "soft" for enforcing the soft limits
#        - "hard" for enforcing hard limits
#
#<item> can be one of the following:
#        - core - limits the core file size (KB)
#        - data - max data size (KB)
#        - fsize - maximum filesize (KB)
#        - memlock - max locked-in-memory address space (KB)
#        - nofile - max number of open files
#        - rss - max resident set size (KB)
#        - stack - max stack size (KB)
#        - cpu - max CPU time (MIN)
#        - nproc - max number of processes
#        - as - address space limit
#        - maxlogins - max number of logins for this user
#        - maxsyslogins - max number of logins on the system
#        - priority - the priority to run user process with
#        - locks - max number of file locks the user can hold
#        - sigpending - max number of pending signals
#        - msgqueue - max memory used by POSIX message queues (bytes)
#        - nice - max nice priority allowed to raise to
#        - rtprio - max realtime priority
#
#<domain>      <type>  <item>         <value>
#

*                soft    core            0
*                hard    core            0
#*               hard    rss             10000
#@student        hard    nproc           20
#@faculty        soft    nproc           20
#@faculty        hard    nproc           50
#ftp             hard    nproc           0
#@student        -       maxlogins       4

oas             hard    nofile          8192

# End of file

Back to top

/etc/sysconfig/rawdevices File

 -rw-r--r-- 1 root root 153  Feb 10 21:18 2011  Oct 13 13:36 2010  rawdevices
# raw device bindings
# format:  <rawdev> <major> <minor>
#          <rawdev> <blockdev>
# example: /dev/raw/raw1 /dev/sda1
#          /dev/raw/raw2 8 5

Back to top

/etc/sysconfig/selinux File

 lrwxrwxrwx 1 root root 17  Feb 10 21:12 2011  Feb 10 21:12 2011  selinux -> ../selinux/config
# This file controls the state of SELinux on the system.
# SELINUX= can take one of these three values:
#	enforcing - SELinux security policy is enforced.
#	permissive - SELinux prints warnings instead of enforcing.
#	disabled - SELinux is fully disabled.
SELINUX=disabled
# SELINUXTYPE= type of policy in use. Possible values are:
#	targeted - Only targeted network daemons are protected.
#	strict - Full SELinux protection.
SELINUXTYPE=targeted

# SETLOCALDEFS= Check local definition changes
SETLOCALDEFS=0

Back to top